• Title/Summary/Keyword: Automatic Alarm System

Search Result 115, Processing Time 0.022 seconds

Development of Landslide Detection Algorithm Using Fully Polarimetric ALOS-2 SAR Data (Fully-Polarimetric ALOS-2 자료를 이용한 산사태 탐지 알고리즘 개발)

  • Kim, Minhwa;Cho, KeunHoo;Park, Sang-Eun;Cho, Jae-Hyoung;Moon, Hyoi;Han, Seung-hoon
    • Economic and Environmental Geology
    • /
    • v.52 no.4
    • /
    • pp.313-322
    • /
    • 2019
  • SAR (Synthetic Aperture Radar) remote sensing data is a very useful tool for near-real-time identification of landslide affected areas that can occur over a large area due to heavy rains or typhoons. This study aims to develop an effective algorithm for automatically delineating landslide areas from the polarimetric SAR data acquired after the landslide event. To detect landslides from SAR observations, reduction of the speckle effects in the estimation of polarimetric SAR parameters and the orthorectification of geometric distortions on sloping terrain are essential processing steps. Based on the experimental analysis, it was found that the IDAN filter can provide a better estimation of the polarimetric parameters. In addition, it was appropriate to apply orthorectification process after estimating polarimetric parameters in the slant range domain. Furthermore, it was found that the polarimetric entropy is the most appropriate parameters among various polarimetric parameters. Based on those analyses, we proposed an automatic landslide detection algorithm using the histogram thresholding of the polarimetric parameters with the aid of terrain slope information. The landslide detection algorithm was applied to the ALOS-2 PALSAR-2 data which observed landslide areas in Japan triggered by Typhoon in September 2011. Experimental results showed that the landslide areas were successfully identified by using the proposed algorithm with a detection rate of about 82% and a false alarm rate of about 3%.

A study on the efficiency advancement for evacuation of the crews by ship structural improvement (선박 구조 개선을 통한 승무원의 피난 효율 향상을 위한 연구)

  • Kim, Wonouk;Lee, Myoungho;Kim, Jongsu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.3
    • /
    • pp.342-348
    • /
    • 2014
  • Onshore great fires can normally be extinguished by firefighters using special firefighting equipment and its suitable method. However, offshore fires on the ships are to be extinguished by the crew without any supports from the onshore. Also, crews working on board are exposed to high risk of emergency evacuation due to the complicated structure arrangement of the ships and different accident types such as fire and ship collisions. As most of damage and loss of life in fire are associated with suffocation, shortening of evacuation time is an important factor to improve a survival rate. In this study, visibility in the accommodation area is analyzed by using the temperature and smoke flow which are obtained by the Fire Dynamic Simulator(FDS) as a Three-Dimensional Fire Analysis program to understand the survival rate of the crew upon the fire. The fire doors for most of ships are designed to close automatically when the fire alarm is activated. These automatic closing of the fire doors is a very effective system to delay the spread of flame and smoke flow for the unmanned spaces of the fire protected area. However, if the crew cannot escape within the estimated time, the crew inside the fire protected area will be damaged a lot. In this paper, the comparative analysis between the evacuations by using the fire door from the fire protected area and the suggested fire shielding structure in this study is carried out by the smoke flow rate and the temperature rise rate.

Bio-Signal Detection Monitoring System Using ZigBee and Wireless Network (거리측정 센서 스캐닝과 퍼지 제어를 이용한 생체신호 모니터링 전동 휠체어 자율주행 시스템)

  • Kim, Kuk-Se;Yang, Sang-Gi;Rasheed, M.Tahir;Ahn, Seong-Soo;Lee, Joon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.10a
    • /
    • pp.331-339
    • /
    • 2008
  • Nowadays with advancement in technology and aging society, the number of disabled citizens is increasing. The disabled citizens always need a caretaker for daily life routines especially for mobility. In future, the need is considered to increase more. To reduce the burden from the disabled, various devices for healthcare are introduced using computer technology. The power wheelchair is an important and convenient mobility device. The demand of power wheelchair is increasing for assistance in mobility. In this paper we proposed a robotic wheelchair for mobility aid to reduce the burden from the disabled. The main issue in an autonomous wheelchair is the automatic detection and avoidance of obstacles and going to the pre-designated place. The proposed algorithm detects the obstacles and avoids them to drive the wheelchair to the desired place safely. By this way, the disabled will not always have to worry about paying deep attention to the surroundings and his path. User has a handheld bio-sensor monitoring system for get user's bio-signal. If user detects unusual signal, alarm send to protector.

  • PDF

Study on the Operation Characteristics of Heat Detectors through Fire and Wind Tunnel Experiment (풍동실험과 화재실험을 통한 열감지기의 동작특성에 관한 연구)

  • Ryu, Hocheol;Kim, Doohyun
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.2
    • /
    • pp.203-209
    • /
    • 2015
  • The heat detector detects heat in the fire and is an important core element of the automatic fire alarm system used generally for every fire prevention objects. The heat detector is distinguished in spot type and spread type and in spot type, there are differential and thermistor types. These heat detectors give a great influence on the loss of people and property according to the sensitivity of response such as operation time and operation temperature in actual fire and in overseas people apply it for the development of products that can be operated in the early stage of fire including certification, quality management, and comparison standard by introducing response time index through the theory of heat balance that considers the heat loss and ventilation tests. In Korea, the response time index is introduced and used in the head of sprinkler products, but it is not applied to the heat detector at present. It is necessary to introduce the response time index that shows the sensitivity of response of the heat detector the installation standard for the heat detector that the response time index is applied should be different according to the fire weight, danger degree of fire, and shape of buildings. Through this study, it tries to help reduce lives and property of people through the swift warning by installing detectors suitable for the building structure.

Analysis of Building Characteristics and Temporal Changes of Fire Alarms (건물 특성과 시간적 변화가 소방시설관리시스템의 화재알람에 미치는 영향 분석 연구)

  • Lim, Gwanmuk;Ko, Seoltae;Kim, Yoosin;Park, Keon Chul
    • Journal of Internet Computing and Services
    • /
    • v.22 no.4
    • /
    • pp.83-98
    • /
    • 2021
  • The purpose of this study to find the factors influencing the fire alarms using IoT firefighting facility management system data of Seoul Fire & Disaster Headquarters, and to present academic implications for establishing an effective prevention system of fire situation. As the number of high and complex buildings increases and former bulidings are advanced, the fire detection facilities that can quickly respond to emergency situations are also increasing. However, if the accuracy of the fire situation is incorrectly detected and the accuracy is lowered, the inconvenience of the residents increases and the reliability decreases. Therefore, it is necessary to improve accuracy of the system through efficient inspection and the internal environment investigation of buildings. The purpose of this study is to find out that false detection may occur due to building characteristics such as usage or time, and to aim of emphasizing the need for efficient system inspection and controlling the internal environment. As a result, it is found that the size(total area) of the building had the greatest effect on the fire alarms, and the fire alarms increased as private buildings, R-type receivers, and a large number of failure or shutoff days. In addition, factors that influencing fire alarms were different depending on the main usage of the building. In terms of time, it was found to follow people's daily patterns during weekdays(9 am to 6 pm), and each peaked around 10 am and 2 pm. This study was claimed that it is necessary to investigate the building environment that caused the fire alarms, along with the system internal inspection. Also, it propose additional recording of building environment data in real-time for follow-up research and system enhancement.