• 제목/요약/키워드: Automated external defibrillators(AED)

검색결과 12건 처리시간 0.025초

자동심장충격기 설치현황 및 관리실태와 사용능력조사 - 충청남도 내 500세대 이상 아파트를 중심으로 (A survey on installation, management, and usability of automated external defibrillators - Focused on apartments with over 500 households in Chungnam)

  • 정준호
    • 한국응급구조학회지
    • /
    • 제21권3호
    • /
    • pp.73-84
    • /
    • 2017
  • Purpose: The purpose of this study was to investigate the installation, management, and usability of automated external defibrillators (AED) installed in the apartments with over 500 households in Chungnam. Methods: The survey included 52 apartments with over 500 households having AED in Chungnam from July 1 to August 20, 2017. The information of AED was taken from the Chungnam Provincial Office. Results: The access and use of AED was closely affected by AED installation location, locking devices, lack of publicity, and AED use education for the residents. Conclusion: Efficient education on the use and management of AED for residents of the apartments is necessary.

일반대학생에 의한 자동제세동기 사용 능력 연구 (A Study on college students ability to use automated external defibrillator(AED))

  • 양현모;권찬양
    • 한국응급구조학회지
    • /
    • 제21권2호
    • /
    • pp.63-69
    • /
    • 2017
  • Purpose: The purpose of the study was to compare the ability of college students to use automated external defibrillators (AED) and to provide a basic data for helping laypersons easily apply the AED. Methods: The subjects were randomly assigned to instruction groups. One group was instructed by pictures (group P), one by videos (group M), and one by telephone dispatchers (group D), Without employing cardiopulmonary resuscitation, a single rescuer was asked to apply defibrillation to a mannequin for practice in accordance with the instructions assigned to each group. Results: Regarding the proper pad attachment of the AED, group P followed the instruction $0.31{\pm}0.47times$, group M, $0.81{\pm}0.40times$, and group D $0.69{\pm}0.47times$. Regarding the instruction of taking the hand off a patient for analyzing cardiac rhythm and the instruction of taking the hand off a patient before defibrillation, group P did not follow the instruction; group M followed the instructions $0.50{\pm}0.51times$; and group D followed all instructions at all times. Conclusion: If a dispatcher gives real-time instructions for using an AED to laypersons wtih no experience at the time of AED use, the quality of laypersons' AED use will greatly improve.

보건계열과 비보건계열 대학생의 자동심장충격기에 대한 인지도 (Awareness of automated external defibrillator among students majoring in health-related versus non-health-related fields)

  • 정해영;김숙희;김철태
    • 한국응급구조학회지
    • /
    • 제21권2호
    • /
    • pp.39-50
    • /
    • 2017
  • Purpose: This study measured awareness of automated external defibrillators (AED) among students majoring in health-related versus non-health-related fields. Methods: A total of 577 students filled out a questionnaire on awareness of AEDs between June 12 and June 28, 2017. Using SPSS 23.0, data were analyzed using descriptive statistics, chi-square tests, and t-tests. Results: In response to a question about awareness of AED, 25.0% of students majoring in a health-related and 38.6% of those majoring in a non-health-related field answered on "I have seen or heard" and "I have no idea". In response to a question on perception on AED use, 82.4% of students majoring in a health-related field and 88.1% of those in a non-health-related field reported that they thought perception of AED use was not universal. In terms of experience with education on the use of AED, 30.2% of health-related majors and 49.7% of non-health-related majors had not received any training on the use of AED. The average overall score regarding knowledge about AED was 8.69 for health-related majors, compared to 7.79 for non-health-related majors. Conclusion: In order to improve awareness regarding AED use, education on importance and necessity of AED should be emphasized and implemented consistently by the mass media.

가상현실을 이용한 자동 제세동기(AED) 훈련 시뮬레이션 개발 (Development of Automated External defibrillator training simulation using Virtual Reality)

  • 임정수;이영광;송은지
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2017년도 춘계학술대회
    • /
    • pp.350-352
    • /
    • 2017
  • 최근 가상현실(VR)이 IT기술의 화두로 떠오르고 있다. 가상현실 기술은 처음엔 게임, 영화, 스포츠, 테마파크와 같이 엔터테인먼트 목적으로 개발되는 경우가 많았으나 점차 교육, e-커머스, 헬스케어 등 다수의 산업으로 확대되어 관련 시장의 확산에 따른 파급효과는 매우 클 것으로 예상된다. 따라서 VR을 접목한 안전교육 콘텐츠도 급부상 하고 있다. 하지만 아직까지도 우리나라의 안전 교육에 대한 프로그램 활성도는 미미한 수준이다. 제세동기를 이용한 급성 심정지 환자 구출은 가장 대표적인 안전 교육중 하나이지만 2014년 기준 국내에서 자동 제세동기를 사용하여 환자의 생명을 구한 공식적인 사례는 단 한건으로 자동 제세동기의 사용 실적이 매우 저조함을 알 수 있다. 자동제세동기 사용성과 접근성 확장을 위한 사용법 및 중요성 숙지 교육이 필요한 현황이지만 이러한 안전 교육을 단순한 이론 교육에서 끝마칠 뿐 체험 교육 마련이 쉬운 일이 아니다. 본 논문에서는 언제든지 자유롭게 효과적으로 훈련을 받을 수 있는 가상현실을 이용한 자동 제세동기 훈련 시뮬레이션을 제안한다.

  • PDF

자동제세동기(AED) 가상훈련 시스템 개발에 관한 연구 (A Study on the Development of Virtual Training System for Automated External Defibrillator)

  • 송은지
    • 한국정보통신학회논문지
    • /
    • 제21권7호
    • /
    • pp.1379-1385
    • /
    • 2017
  • 가상훈련은 특정한 훈련을 목적으로 훈련에 필요한 환경이나 상황을 가상으로 구현하여 실제 상황처럼 진행하는 교육 훈련으로써 최근에는 가상현실 기술의 급격한 발전으로 인해 현실세계에서 직접 경험하지 못하는 상황을 실감적으로 체험하는 것에 대한 요구가 더욱 증대하고 있다. 특히, 안전 불감증으로 인해 수많은 재난 사고로 인명 피해가 끊이지 않는 우리나라에서는 안전교육이 매우 필요하므로 가상현실을 이용한 재난대응 훈련 시뮬레이션이 어느 때보다 시급하다. 본 논문에서는 가상현실 기술을 이용하여 심장충격기인 자동제세동기(AED) 훈련 시스템을 제안하고 구현한다. 자동제세동기는 급성심장정지 환자를 구출하기 위해 가장 필요한 의료 기기임에도 불구하고 사용법을 숙지하고 있는 사람이 많지 않아 국내에서 자동제세동기를 사용하여 환자의 생명을 구한 사례는 매우 미미하다. 제안하는 AED 가상훈련 시스템은 실제와 같은 상황에서 몰입감이 있고 체험적인 훈련이 가능하며 저렴한 비용으로 훈련이 가능하여 매우 유용하다.

Does the placement of automated external defibrillators affect first responders' willingness to perform cardiopulmonary resuscitation in high-rise residential buildings?

  • ;류현욱
    • 대한응급의학회지
    • /
    • 제29권6호
    • /
    • pp.557-567
    • /
    • 2018
  • Objective: The increasing number of people living in high-rise apartments may result in a delayed response from emergency medical technicians called out for an out-of-hospital cardiac arrest, making the role of apartment managers as the first responders extremely important. This study investigated whether automated external defibrillator (AED) placement influences the willingness of apartment managers to perform cardiopulmonary resuscitation (CPR) and use an AED. Methods: A cross-sectional target population-based survey was conducted in Daegu, July 2016. Questionnaires were sent to apartment managers working in apartments with more than 500 households. The general characteristics of the respondents, status of CPR education, and knowledge about and willingness to perform CPR and use an AED were investigated. Results: Of the 1,445 respondents, 758 (52.5%) worked in apartments with AEDs, of which 77.8% and 70.8% were willing to perform CPR and use an AED, respectively, compared with 68.1% and 60.0% of respondents who worked in apartments without AEDs. After adjusting for potential confounders, AED placement was associated with the willingness to perform CPR (odds ratio [OR], 1.33; 95% confidence interval [CI], 1.04-1.71) and use an AED (OR, 1.39; 95% CI, 1.10-1.75). Prior CPR training and accurate knowledge of CPR skills were also associated with the willingness to perform CPR and use an AED. Conclusion: Placing AEDs in high-rise apartment buildings and providing refresher CPR education for maintaining CPR skills will be necessary to support apartment managers in their role as first responders.

일반인의 AED 사용에 관한 한·일 비교 연구 (South Korean and Japanese intention to use automated external defibrillators in out-of-hospital cardiac arrest situations)

  • 임승환
    • 한국응급구조학회지
    • /
    • 제18권1호
    • /
    • pp.17-27
    • /
    • 2014
  • 연구 목적 : 한국에서 일반인의 의한 AED의 사용 사례를 극히 드물다. 병원 전 심정지 상황에서 특히 제세동이 필요한 환자의 소생률을 높이기 위해서는 일반인에 의한 AED 사용이 요구된다. 본 연구의 목적은 AED사용에 영향을 미치는 요인을 분석하는 것이며, 한일 비교를 통해 사회적 특성이 있는지를 확인하는 것이다. 연구 방법 : 2013년 2월 25일부터 3월 4일까지 설문 조사를 실시했다. 한국에서 517명, 일본에서 520명의 데이터를 회수했다. 설문지를 통해 파악한 사회인구학적 요인과 AED에 관한 지식 요인이 AED사용의도에 영향을 미치는지를 알기 위해 로지스틱 회귀분석을 실시했다. 연구 결과 : 한국의 517 명의 응답자 중 220명, 42.6%만이, 그리고 일본의 520명의 응답자 중 387 명, 74.4%가 AED를 사용해 환자를 도우려는 의사를 가지고 있었다. 한국과 일본 모두 성별은 유의한 요인이었다(한국 odd ratio[OR] = 0.419, 일본 OR = 0.582). 양국 모두에서 여성은 남성에 비해 AED를 사용해 환자를 도우려고 하지 않았다. AED에 관한 지식은 양국 모두에서 가장 큰 영향을 끼치는 요인이었다. 국가 간의 차가 있었던 요인은 우선 연령이었다. 연령 요인이 한국에서는 유의하지 않았지만 일본에서는 젊을수록 AED 사용의사가 높았다(OR = 0.968). 또한 일본에서는 심장병력이 유의한 요인(OR=2.099)이었다. 결 론: 본 연구는 AED사용의도에 가장 큰 영향을 끼치는 요인이 AED에 관한 지식임을 밝혔다. 따라서, 병원 전 심정지 상황에서 제세동을 장려하기 위해서는 AED 설치와 함께 사회적 요인을 반영한 교육 프로그램이 필요하다.

Factors influencing success and safety of AED retrieval in out of hospital cardiac arrests in Singapore

  • NG, Jonathan Shen You;HO, Reuben Jia Shun;YU, Jae Yong;NG, Yih Yng
    • 한국응급구조학회지
    • /
    • 제26권2호
    • /
    • pp.97-111
    • /
    • 2022
  • 연구 목적: 병원 밖 심정지(OHCA)에서 자동제세동기(AED)의 사용은 환자의 생존율을 향상시킨다. 싱가포르는 절도를 막고자 공공 AED를 '브레이크 글래스' 기전의 잠금 박스로 보호하고 있는데 지역사회 대응자들은 AED를 회수하기 위해 유리를 깨면서 부상을 당하곤 했다. 최초로 시도한 본 연구는 성공적인 AED 회수에 영향을 미치는 요인들을 밝히고 만연한 부상을 문서화하고자 하였다. 연구 방법: 설문지를 작성, 배포하였다. 참가자는 지난 12개월 동안 OHCA에 대처한 자들이다. 비교 검정은 피셔-프리만-할턴 정확 검정 또는 피어슨 카이제곱 검정을 사용하여 5% 유의 수준에서 시행되었고, 로짓링크함수를 사용하여 다중로지스틱회귀분석을 시행하였다. 연구 결과: 88명의 참가자가 적격했다. 성공적인 AED의 회수는 직업, 연령, 성별 및 시간 영향을 받지 않았다. myResponder 앱의 활성화로 OHCA에 대응했던 참가자들은 성공적으로 AED를 회수할 가능성이 높았다. (AOR 11.111, 95% CI: 2.141-58.824) 결 론: 모바일 myResponder 앱을 활용할 경우 AED회수 성공률이 훨씬 높았다. AED의 성공적 회수는 시간 뿐만 아니라 이용자의 성별, 연령, 직업과 무관했다. 싱가포르에서 지역사회 대응자들은 부상 위험에도 불구하고 심정지에 대응할 적극적 자세가 되어 있다.

자동심장충격기 설치현황 및 관리 실태 조사 (A survey on installation and management of automated external defibrillators)

  • 서혜진;윤수지;김효식
    • 한국산학기술학회논문지
    • /
    • 제19권7호
    • /
    • pp.245-251
    • /
    • 2018
  • 본 조사 연구는 일개 도내의 자동심장충격기 의무설치 기관의 자동심장충격기 설치현황 및 관리 점검 실태를 파악하기 위한 조사연구이다. 2017년 11월 20일부터 2017년 12월 20일까지 진행되었으며 총 169대의 자동심장충격기를 대상으로 조사하였다. 수집된 자료의 분석은 SPSS/WIN 20.0 프로그램을 이용하여 빈도분석과 백분율로 파악하였다. AED는 168대(99.41%)가 기관 실내에 설치되어 있는 것으로 조사되었으며, 24시간 항시 자동심장충격기가 운영되고 있는 경우는 47대(27.80%), 기관 운영시간 외에 자동심장충격기를 사용할 수 있는 경우는 44대(26.00%)으로 파악되었다. 책임관리자가 구조 및 응급처치 교육을 받은 경우가 87명(51.43%)이었으며, 자동심장충격기의 관리현황은 배터리 충전상태의 문제가 있는 경우는 2대(1.20%), 환자 부착용 AED패드의 유효기간이 지난 경우로 7대(4.10%)로 조사되었다. 향후 자동심장충격기 관리책임자를 위한 관리체계를 마련하고, 체계적 유지관리에 대한 정기적인 교육 프로그램을 개발하여 적용해야 한다. 또한 자동심장충격기 설치 관리에 대한 법률 강화 및 제도적 정비를 통한 지속적인 관리실태의 필요성에 대한 인식을 제고할 필요가 있다.

자동제세동기의 접근성 향상을 위한 배치 적정성 연구 (A Study of Optimal Location and Allocation to Improve Accessibility of Automated External Defibrillator)

  • 권필;이영민;유기윤;이원희
    • 한국측량학회지
    • /
    • 제34권3호
    • /
    • pp.263-271
    • /
    • 2016
  • 최근 인구 고령화와 심혈관계 질환의 발병률 증가로 인해 매년 급성 심정지 환자가 늘고 있다. 환자의 생존율을 높이기 위해서는 신속한 심폐소생술이 필수적이며, 이에 따라 국가에서는 심폐소생술 처치 시 활용 가능한 자동제세동기(Automated External Defibrillator, AED)의 보급을 확대하고 있다. 그러나 지방자치단체에서 설치한 AED는 주로 건물 내부에 비치되어 있어 건물 외부에서 발생한 급성 심정지 환자에 효율적인 대응을 할 수 없다. 실험지역의 급성 심정지 환자의 분포를 확인한 결과, 약 11%의 심정지 사건이 도로 및 주택가를 포함한 오픈 스페이스에서 발생하였음을 확인하였다. 이에 본 연구는 급성 심정지 환자의 소생률을 높이기 위해 41개의 AED를 GIS 입지분석 방법을 사용하여 추가적으로 배치하였다. 실험 결과의 타당성을 확보하기 위해 같은 수의 AED를 무작위로 배치한 것이 포함하는 노인층 유동인구 밀도와 본 실험을 통해 배치된 것과 비교하였다. 그 결과, 지형적 그리고 사회적인 특성으로 인해 발생한 소수의 이상치를 제외하고는, 본 실험 결과로 도출된 AED가 포함하는 노인층 유동인구 밀도가 약 5% 가량 더 높았음을 확인할 수 있었다.