• Title/Summary/Keyword: Autoignition Temperature (AIT)

Search Result 73, Processing Time 0.029 seconds

The Measurement and Investigation of Fire and Explosion Properties for Acetone (아세톤의 화재 및 폭발 특성치 측정 및 고찰)

  • Ha, Dong-Myeong
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.4
    • /
    • pp.30-35
    • /
    • 2010
  • For the safe handling of acetone, the flash point, the explosion limit at $25^{\circ}C$ and the temperature dependence of the explosion limits were investigated. And the AIT for acetone were experimented. By using the literatures data, the lower and upper explosion limits of acetone recommended 2.5 vol% and 13.0 vol%, respectively. In this study, the lower flash points of acetone recommended $-20^{\circ}C$. This study was determined relationship between the AITs and the ignition delay times by using ASTM E659-78 apparatus for acetone, and the experimental AIT of acetone was $565^{\circ}C$. The new equations for predicting the temperature dependence of the explosion limits of acetone is proposed. The values calculated by the proposed equations were a good agreement with the literature data.

The Measurement and Prediction of Combustible Properties of Dimethylacetamide (DMAc) (디메틸아세트아미드(DMAc)의 연소특성치의 측정 및 예측)

  • Ha, Dong-Myeong
    • Korean Chemical Engineering Research
    • /
    • v.53 no.5
    • /
    • pp.553-556
    • /
    • 2015
  • The usage of the correct combustion characteristic of the treated substance for the safety of the process is critical. For the safe handling of dimethylacetamide (DMAc) being used in various ways in the chemical industry, the flash point and the autoignition temperature (AIT) of DMAc was experimented. And, the lower explosion limit of DMAc was calculated by using the lower flash point obtained in the experiment. The flash points of DMAc by using the Setaflash and Pensky-Martens closed-cup testers measured $61^{\circ}C$ and $65^{\circ}C$, respectively. The flash points of DMAc by using the Tag and Cleveland automatic open cup testers are measured $68^{\circ}C$ and $71^{\circ}C$. The AIT of DMAc by ASTM 659E tester was measured as $347^{\circ}C$. The lower explosion limit by the measured flash point $61^{\circ}C$ was calculated as 1.52 vol%. It was possible to predict lower explosion limit by using the experimental flash point or flash point in the literature.

Measurement and Prediction of the Combustible Properties of Propionic Anhydride (Propionic Anhydride의 연소특성치의 측정 및 예측)

  • Ha, Dong-Myeong
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.3
    • /
    • pp.66-72
    • /
    • 2016
  • For the safe handling of Propionic Anhydride being used in various ways in the chemical industry, the flash point and the autoignition temperature(AIT) of Propionic Anhydride was experimented. And, the lower explosion limit of propionic anhydride was calculated by using the lower flash point obtained in the experiment. The flash points of propionic anhydride by using the Setaflash and Pensky-Martens closed-cup testers measured $60^{\circ}C$ and $61^{\circ}C$, respectively. The flash points of propionic anhydride by using the Tag and Cleveland open cup testers are measured $67^{\circ}C$ and $73^{\circ}C$. The AIT of propionic anhydride by ASTM 659E tester was measured as $280^{\circ}C$. The lower explosion limit by the measured flash point $60^{\circ}C$ was calculated as 1.37 Vol.%. It was possible to predict lower explosion limit by using the experimental flash point or flash point in the literature.

The Prediction and Measurement of Combustible Properties for Bromobenzene (브로모벤젠의 연소특성치의 측정 및 예측)

  • Ha, Dong-Myeong
    • Fire Science and Engineering
    • /
    • v.29 no.4
    • /
    • pp.21-25
    • /
    • 2015
  • The usage of the correct combustion characteristics of the treated substance for the safety of the process is critical. For the safe handling of bromobenzene being used in various ways in the chemical industry, the flash point and the autoignition temperature (AIT) of bromobenzene was experimented. And, the lower explosion limit of bromobenzene was calculated by using the lower flash point obtained in the experiment. The flash points of bromobenzene by using the Setaflash and Pensky-Martens closed-cup testers measured $44^{\circ}C$ and $50^{\circ}C$, respectively. The flash points of bromobenzene by using the Tag and Cleveland automatic open cup testers are measured $56^{\circ}C$ and $64^{\circ}C$. The AIT of bromobenzene by ASTM 659E tester was measured as $573^{\circ}C$. The lower explosion limit by the measured flash point $44^{\circ}C$ was calculated as 1.63 Vol%. It was possible to predict lower explosion limit by using the experimental flash point or flash point in the literature.

Measurement and Prediction of the Combustible Properties of Cumene (큐멘(Cumene)의 연소특성치의 측정 및 예측)

  • Ha, Dong-Myeong
    • Korean Chemical Engineering Research
    • /
    • v.54 no.4
    • /
    • pp.465-469
    • /
    • 2016
  • The usage of the correct combustion characteristic of the treated substance for the safety of the process is critical. For the safe handling of cumene being used in various ways in the chemical industry, the flash point and the autoignition temperature (AIT) of cumene was experimented. And, the lower explosion limit of cumene was calculated by using the lower flash point obtained in the experiment. The flash points of cumene by using the Setaflash and Pensky-Martens closed-cup testers measured $31^{\circ}C$ and $33^{\circ}C$, respectively. The flash points of cumene by using the Tag and Cleveland open cup testers are measured $43^{\circ}C$ and $45^{\circ}C$. The AIT of cumene by ASTM 659E tester was measured as $419^{\circ}C$. The lower explosion limit by the measured flash point $31^{\circ}C$ was calculated as 0.87 vol%. It was possible to predict lower explosion limit by using the experimental flash point or flash point in the literature.

The Measurement and Prediction of the Fire and Explosion Properties of Isoamyl alcohol (이소아밀알코올의 화재 및 폭발 특성치의 측정 및 예측)

  • Ha, Dongmyeong
    • Journal of Energy Engineering
    • /
    • v.25 no.3
    • /
    • pp.34-40
    • /
    • 2016
  • For the safe handling of isoamyl alcohol being used in various ways in the chemical industry, the flash point and the autoignition temperature(AIT) of isoamyl alcohol was experimented. And, the lower explosion limit of isoamyl alcohol was calculated by using the lower flash point obtained in the experiment. The flash points of isoamyl alcohol by using the Setaflash and Pensky-Martens closed-cup testers measured $31^{\circ}C$ and $33^{\circ}C$, respectively. The flash points of isoamyl alcohol by using the Tag and Cleveland open cup testers are measured $43^{\circ}C$and $45^{\circ}C$. The AIT of isoamyl alcohol by ASTM 659E tester was measured as $419^{\circ}C$. The lower explosion limit by the measured flash point $31^{\circ}C$ was calculated as 0.87 vol%. It was possible to predict lower explosion limit by using the experimental flash point or flash point in the literature.

The Measurement of the Fire and Explosion Properties for 2-Methyl-1-butanol (2-Methyl-1-butanol의 화재 및 폭발 특성치의 측정)

  • Ha, Dong-Myeong
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.4
    • /
    • pp.8-14
    • /
    • 2015
  • For the safe handling of 2-methyl-1-butanol being used in various ways in the chemical industry, the flash point and the autoignition temperature(AIT) of 2-methyl-1-butanol was experimented. And, the lower explosion limit of 2-methyl-1-butanol was calculated by using the lower flash point obtained in the experiment. The flash points of 2-methyl-1-butanol by using the Setaflash and Pensky-Martens closed-cup testers measured $40^{\circ}C$ and $44^{\circ}C$, respectively. The flash points of 2-methyl-1-butanol by using the Tag and Cleveland open cup testers are measured $49^{\circ}C$ and $47^{\circ}C$. The AIT of 2-methyl-1-butanol by ASTM 659E tester was measured as $335^{\circ}C$. The lower explosion limit by the measured flash point $40^{\circ}C$ was calculated as 1.30 Vol.%. It was possible to predict lower explosion limit by using the experimental flash point or flash point in the literature.

Measurement and Prediction of Combustion Properties of n-Phenol (페놀의 연소특성치의 측정 및 예측)

  • Ha, Dong-Myeong
    • Korean Journal of Hazardous Materials
    • /
    • v.6 no.2
    • /
    • pp.23-29
    • /
    • 2018
  • The fire and explosion properties necessary for waste, safe storage, transport, process design and operation of handling flammable substances are lower explosion limits(LEL), upper explosion limits(UEL), flash point, AIT( minimum autoignition temperature or spontaneous ignition temperature), fire point etc., An accurate knowledge of the combustion properties is important in developing appropriate prevention and control measures fire and explosion protection in chemical plants. In order to know the accuracy of data in MSDSs(material safety data sheets), the flash point of phenol was measured by Setaflash, Pensky-Martens, Tag, and Cleveland testers. And the AIT of phenol was measured by ASTM 659E apparatus. The explosion limits of phenol was investigated in the reference data. The flash point of phenol by using Setaflash and Pensky-Martens closed-cup testers were experimented at $75^{\circ}C$ and $81^{\circ}C$, respectively. The flash points of phenol by Tag and Cleveland open cup testers were experimented at $82^{\circ}C$ and $89^{\circ}C$, respectively. The AIT of phenol was experimented at $589^{\circ}C$. The LEL and UEL calculated by using Setaflash lower and upper flash point value were calculated as 1.36vol% and 8.67vol%, respectively. By using the relationship between the spontaneous ignition temperature and the ignition delay time proposed, it is possible to predict the ignition delay time at different temperatures in the handling process of phenol.

Risk Assessment by Means of Measurement of Combustible Characteristics for n-Nonanol (노말노난올의 연소특성치 측정에 의한 위험성 평가)

  • Ha, Dong-Myeong
    • Fire Science and Engineering
    • /
    • v.26 no.2
    • /
    • pp.84-89
    • /
    • 2012
  • For the safe handling of n-nonanol, this study was investigated the explosion limits of n-nonanol in the reference data. The flash points and AITs (autoignition temperatures) by ignition delay time were experimented. As a results, the lower and upper explosion limits of n-nonanol recommended 0.8 Vol.% and 6.1 Vol.%, respectively. The lower flash points of n-nonanol by using closed-cup tester were experimented $94{\sim}97^{\circ}C$. The lower flash points of n-nonanol by using open cup tester were experimented $103{\sim}104^{\circ}C$. This study measured relationship between the AITs and the ignition delay times by using ASTM E659-78 apparatus for n-nonanol. The experimental AIT of n-nonanol was $270^{\circ}C$.

Combustion Property of Biodiesel Fuel (바이오디젤 연료의 연소 특성)

  • Song, Young-Ho;Shin, Baeg-Woo;Ha, Dong-Myeong;Chung, Kook-Sam
    • Fire Science and Engineering
    • /
    • v.23 no.4
    • /
    • pp.19-24
    • /
    • 2009
  • As the environmental pollution by the drastic increase of vehicles becomes one of the social major concerns, the method of reducing the harmful exhaust emission is being the subject of interest. Utilization of waste edible oil as a raw material for biodiesel production is helpful not only for the stable supply of raw materials but also costing down the biodiesel price. This study was conducted to examine the combustion and thermal characteristics with mixing ratio of biodiesel fuel. Flash points, fire points and autoignition temperature (AIT) were measured by using Tag closed cup, Cleveland open cup flash point tester and AIT apparatus. As the result, flash points, fire points and AIT increased with percentage of more contained biodiesel.