• Title/Summary/Keyword: Auto-Calibration

Search Result 118, Processing Time 0.035 seconds

Evaluation of Regression Models in LOADEST to Estimate Suspended Solid Load in Hangang Waterbody (한강수계에서의 부유사 예측을 위한 LOADEST 모형의 회귀식의 평가)

  • Park, Youn Shik;Lee, Ji Min;Jung, Younghun;Shin, Min Hwan;Park, Ji Hyung;Hwang, Hasun;Ryu, Jichul;Park, Jangho;Kim, Ki-Sung
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.57 no.2
    • /
    • pp.37-45
    • /
    • 2015
  • Typically, water quality sampling takes place intermittently since sample collection and following analysis requires substantial cost and efforts. Therefore regression models (or rating curves) are often used to interpolate water quality data. LOADEST has nine regression models to estimate water quality data, and one regression model needs to be selected automatically or manually. The nine regression models in LOADEST and auto-selection by LOADEST were evaluated in the study. Suspended solids data were collected from forty-nine stations from the Water Information System of the Ministry of Environment. Suspended solid data from each station was divided into two groups for calibration and validation. Nash-Stucliffe efficiency (NSE) and coefficient of determination ($R_2$) were used to evaluate estimated suspended solid loads. The regression models numbered 1 and 3 in LOADEST provided higher NSE and $R_2$, compared to the other regression models. The regression modes numbered 2, 5, 6, 8, and 9 in LOADEST provided low NSE. In addition, the regression model selected by LOADEST did not necessarily provide better suspended solid estimations than the other regression models did.

Development of Quality Control Method for a Novel Herbal Medicine, HPL-1 using UHPLC (UHPLC를 이용한 새로운 한약제제 HPL-1의 품질관리법 개발)

  • Kim, Se-Gun;Lamichhane, Ramakanta;Lee, Kyung-Hee;Jung, Hyun-Ju
    • The Korea Journal of Herbology
    • /
    • v.30 no.3
    • /
    • pp.19-24
    • /
    • 2015
  • Objectives : HPL-1, a novel herbal medicine which is composed of five herbs such as Kalopanacis Cortex, Chaenomelis Fructus, Raphani Semen, Atractylodis Rhizoma and Pulvis Aconiti Tuberis Purificatum, was developed for treatment of osteoarthritis. This study is aimed to develop analytical method for consistent quality control of HPL-1 and validate chromatographic method. Methods : Chromatographic analysis was performed using ultra-high performance liquid chromatography - diode array detector (UHPLC-DAD) equipped with RP-amide column, column oven, and auto sampler. Marker compounds [protocatechuic acid, chlorogenic acid, liriodendrin, 3,5-dicaffeoylquinic acid, ${\beta}$-D-(3-O-sinapoyl)-fructofuranosyl-$\alpha$-D-(6-O-sinapoyl)glucopyranoside and benzoylmesaconine] were separated by step gradient elution of acetonitrile and 0.1% phosphoric acid/water. The method validation was evaluated by quantitative validation parameters of linearity, accuracy, precision, limit of detection (LOD) and limit of quantification (LOQ) according to KFDA guideline.Results : An optimized method for six marker compounds in HPL-1 was established by UHPLC-DAD. The correlation coefficient (R2) with each calibration curve was greater than 0.99. The LOD and LOQ were within the range of 0.008-0.090 and $0.023-0.274{\mu}g/mL$, respectively. The relative standard deviation (RSD) of intra- and inter-day variability were less than 4.0%. The result of recovery test was range from 93.3-106.3% with RSD < 4.0%.Conclusions : These results suggest that the quantitative UHPLC method is precise, accurate, effective for quality evaluation of HPL-1. The method may also contribute to improve quality of crude drug preparations used for treatment of various diseases.

First Light Results of IGRINS Instrument Control Software

  • Lee, Hye-In;Pak, Soojong;Sim, Chae Kyung;Le, Huynh Anh N.;Jeong, Ueejeong;Chun, Moo-Young;Park, Chan;Yuk, In-Soo;Kim, Kangmin;Pavel, Michael;Jaffe, Daniel T.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.1
    • /
    • pp.54.2-54.2
    • /
    • 2014
  • IGRINS (Immersion GRating Infrared Spectrograph) is a high spectral resolution near-infrared spectrograph that has been developed in a collaboration between the Korea Astronomy & Space Science Institute and the University of Texas at Austin. By using a silicon immersion echelle grating, the size of the fore optics is reduced by a factor of three times and we can make a more compact instrument. One exposure covers the whole of the H- and K-band spectrum with R=40,000. While the operation of and data reduction for this instrument is relatively simple compared to other grating spectrographs, we still need to operate three infrared arrays, cryostat sensors, calibration lamp units, and the telescope during astronomical observations. The IGRINS Instrument Control Software consists of a Housekeeping Package (HKP), Slit Camera Package (SCP), Data Taking Package (DTP), and Quick Look Package (QLP). The SCP will do auto guiding using a center finding algorithm. The DTP will take the echellogram images of the H and K bands, and the QLP will confirm fast processing of data. We will have a commissioning observations in 2014 March. In this poster, we present the performance of the software during the test observations.

  • PDF

Development of Highly Sensitive Analytical Method for Evaluation of Evening Primrose Oil's Enhancing Effect in Prostaglandin E1(OP 1206) Biosynthesis

  • Lee, Sung-Hoon
    • Journal of People, Plants, and Environment
    • /
    • v.21 no.6
    • /
    • pp.485-492
    • /
    • 2018
  • This study aimed to develop and validate highly sensitive determination method of a prostaglandin ($PGE_1$, OP 1206) in human plasma by LC-MS/MS using column switching. Plasma stored at $-30^{\circ}C$ and treated with methanol effectively inhibited interferences synthesized post-sampling. Samples were added with internal standard and were separated by reversed-phase HPLC with a cycle time of 30min. The method was selective for OP 1206 and the regression models, based on internal standard, were linear across the concentration range 0.5-50 pg/mL with the limit of quantification of 0.5 pg/mL (limit of quantitation, LOQ) for OP 1206. The calibration curve of OP 1206 standards spiked in five individual plasma samples was linear ($r^2=0.9999$). Accuracy and precision at the concentrations of 0.5, 1.5, 5.0 and 40 pg/mL, and at the lower LOQ of 0.5 pg/mL were excellent at 20%. OP120 < 6 was stable in plasma samples for at least 24 hours at room temperature, 24 hours frozen at $-70^{\circ}C$, 24 hours in an auto sampler at $6^{\circ}C$, and for two freeze/unfreezing cycles. The validated determination method successfully quantified the concentrations of OP 1206 in plasma samples from simulated administrating a single $5{\mu}g$ OP 1206 formulation. Thus, this novel LC-MS/MS technique for drug separation, detection and quantitation is expected to become the standard highly-sensitive detection method in bioanalysis and to be applied to many low dose pharmaceutical products.

The Study of automated inspection technology using a three-dimensional reconstruction of stereo X-ray image based dual-sensor Environment (Dual-Sensor 기반 스테레오 X-선 영상의 3차원 형상복원기술을 이용한 검색 자동화를 위한 연구)

  • Hwang, Young-Gwan;Lee, Nam-Ho;Kim, Jong-Ryul
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.05a
    • /
    • pp.695-698
    • /
    • 2014
  • As most the scanning systems developed until now provide radiation scan plane images of the inspected objects, there has been a limitation in judging exactly the shape of the objects inside a logistics container exactly with only 2-D radiation image information. Two 2-dimensional radiation images which have different disparity values are acquired from a newly designed stereo image acquisition system which has one additional line sensor to the conventional system. Using a matching algorithm the 3D reconstruction process which find the correspondence between the images is progressed. In this paper, we proposed a new volume based 3D reconstruction algorithm and experimental results show the proposed new volume based reconstruction technique can provide more efficient visualization for cargo inspection. The proposed technique can be used for the development of the high speed and more efficient non-destructive auto inspection system.

  • PDF

Development of optimization method for water quality prediction accuracy (수질예측 정확도를 위한 최적화 기법 개발)

  • Lee, Seung Jae;Kim, Hyeon Sik;Sohn, Byeong Yong;Han, Ji Hyun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.41-41
    • /
    • 2018
  • 하천과 저수지의 수질을 예측하고 관리하는데 수리 수질예측모형이 널리 활용되고 있다. 수질예측모형은 유역이나 수체 내의 오염물질 이동경로나 농도를 수치해석 방법으로 계산하여 사용자가 필요로 하는 지점과 시점에서의 수질자료 생산하는데 활용되고 있다. 수질예측모형은 검 보정을 통해 정확도를 확보하며, 정확도의 확보를 위해서는 높은 수준의 전문성을 필요로 한다. 특히 시행착오법으로 모형을 보정하는 경우 많은 시간과 노력을 필요로 하게 되며, 보정계수를 과대 혹은 과소로 모형에 적용하는 오류를 범하기 쉽고 모델러의 주관이 관여되기 쉽다. 그래서 본 연구에서는 CE-QUAL-W2모형의 조류항목에 대한 모형 보정을 위하여 Chl-a와 남조류세포수에서 주로 활용되고 있는 보정계수에 대한 민감도 분석 결과를 토대로 매개변수별 모의결과 변화율을 산정하였으며, 시기적 경향성을 재현하기 위해 Ensemble-Bagging 기법과 머신 러닝 기법을 적용하여 모형 구동횟수를 최소화 할 수 있는 방법으로 구성하였다. Chl-a를 보정하기 위한 매개변수는 9개를 선정하였으며, 규조류, 남조류, 녹조류에 총 27개 매개 변수를 민감도 분석으로 도출 한 후 예상 변화율 대비 이벤트별 모의치와 실측치 간 %difference가 유사하도록 매개변수를 조정하였다. 또한 각 이벤트 조합의 매개변수 빈도수와 매개변수별 예상변화율, 시기적 조류특성을 고려하여 가중치를 도출하였으며, 1회 보정에 맞춰 Chl-a 모델 실행결과를 %difference로 평가한 후 "good"등급을 만족할 때까지 반복 적용하였다. 남조류세포수의 경우 Chl-a에 맞춰 매개변수 최적화 이후 남조류세포수 농도를 세포수로 환산하기 위한 CACEL에 대해 머신러닝 기법을 적용하였으며, CACEL 추정변화율 회귀식에 따라 평가 한 후 %difference "good"등급 이상을 만족할 때까지 반복 수행하는 방법을 적용하였다. 본 연구에서는 수질예측모형의 정확도를 확보하기 위하여 최적화 기법을 적용하였으며, 이를 통해 모형을 보정하는 과정에서 요구되는 시간과 노력을 줄일 수 있도록 하였으며, Ensemble기법과 머신러닝 기법을 적용하여 모형보정계수 적용에 객관성을 확보할 수 있도록 하였다.

  • PDF

Development of an Image Processing Algorithm for Paprika Recognition and Coordinate Information Acquisition using Stereo Vision (스테레오 영상을 이용한 파프리카 인식 및 좌표 정보 획득 영상처리 알고리즘 개발)

  • Hwa, Ji-Ho;Song, Eui-Han;Lee, Min-Young;Lee, Bong-Ki;Lee, Dae-Weon
    • Journal of Bio-Environment Control
    • /
    • v.24 no.3
    • /
    • pp.210-216
    • /
    • 2015
  • Purpose of this study was a development of an image processing algorithm to recognize paprika and acquire it's 3D coordinates from stereo images to precisely control an end-effector of a paprika auto harvester. First, H and S threshold was set using HSI histogram analyze for extracting ROI(region of interest) from raw paprika cultivation images. Next, fundamental matrix of a stereo camera system was calculated to process matching between extracted ROI of corresponding images. Epipolar lines were acquired using F matrix, and $11{\times}11$ mask was used to compare pixels on the line. Distance between extracted corresponding points were calibrated using 3D coordinates of a calibration board. Non linear regression analyze was used to prove relation between each pixel disparity of corresponding points and depth(Z). Finally, the program could calculate horizontal(X), vertical(Y) directional coordinates using stereo camera's geometry. Horizontal directional coordinate's average error was 5.3mm, vertical was 18.8mm, depth was 5.4mm. Most of the error was occurred at 400~450mm of depth and distorted regions of image.

Development of Frequency Weighing Sensor and Single Crystal Growth (새로운 무게센서 재발과 단결정성장(1))

  • Jang Y.N.;Sung N.H.;Chae S.C.;Bae I.K.;Kim I.J.
    • Korean Journal of Crystallography
    • /
    • v.8 no.1
    • /
    • pp.38-47
    • /
    • 1997
  • A new weighing sensor for the automatic diameter control system of the crystal growth is developed in this study. This weighing sensor measures the frequency of the vibrating element which is lineally changing with respect to weight. The signal and the power of this system are transmitted without any physical contact, so that this sensor offers high accuracy and resolution. This system consists of a string, a sinusoidal wave generator, an automatic amplification adjusting circuit, signal transformers and a PCB. 4 kinds of programs are developed for checking DAC, weight calibration and controlling growth process. The measurements of the standard deviation and the resolution show $\pm0.10g$(measured at every second) and $5{\times}10^{-5}$, respectively, This weighing sensor is effective under high pres-sure of 200 atm, high temperature and vacuum condition. The weighing system can control the temperature in the accuracy of $\pm0.025^{\circ}C$ with the 'signal divider'. The optical quality single crystals of $(YGd)_3Sc_2Ga_3O_{12},\;Er-Y_3Sc_2Al_3O_{12},\;and\;Bi_{12}GeO_{20}$ have been grown by Czo-chralski method using this auto-diameter control system.

  • PDF