• Title/Summary/Keyword: Auto Exposure

Search Result 91, Processing Time 0.031 seconds

Study for Automatic Exposure Control Technique (AEC) in SPECT/CT for Reducing Exposure Dose and Influencing Image Quality (SPECT/CT에서 자동노출제어(AEC)를 이용함으로써 얻어지는 영상의 질 평가와 피폭선량 감소에 관한 고찰)

  • Yoon, Seok-Hwan;Lee, Sung-Hwan;Cho, Seong-Wook;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.33-38
    • /
    • 2014
  • Purpose Auto exposure control (AEC) in SPECT/CT automatically controls the exposure dose (mA) according to patient's shape and size. The aim of this study was to evaluate the effect of AEC in SPECT/CT on exposure dose reduction and image quality. Materials and Methods The model of SPECT/CT used in this study was Discovery 670 (GE, USA), Smart mA for AEC; and $^{99m}Tc$ as a radioisotope. To compare SPECT and CT images by CT exposure dose variation, we used a standard technique set at 80, 100, 120, 140 kVp, 10, 30, 50, 100, 150, 200, 250 mA, and AEC at 80, 100, 120, 140 kVp, 10-250 mA. To evaluate resolution and contrast of SPECT images, triple line phantom and flangeless Esser PET phantom were used. For CT images, noise and uniformity were checked by anthropomrphic chest phantom. For dose evaluation to find DLP value, anthropomorphic chest phantom was used and the CT protocol of torso was applied by standard technique (120 kVp, 100 mA) and AEC (120 kVp, 10-250 mA). Results When standard and AEC were applied, the resolutions at SPECT images with attenuation correction (AC) were the same as FWHM by center 3.65 mm, left 3.48 mm, right 3.61 mm. Contrasts of standard and AEC showed no significant difference: standard 53.5, 29.8, 22.5, 15.8, 6.0, AEC 53.5, 29.6, 22.4, 15.7, 6.1 In CT images, noise values at standard and AEC were 15.4 and 18.5 respectively. The application of AEC increases noise but the value of coefficient variation were 33.8, 24.9 respectively, obtaining uniform noise image. The values of DLP at standard and AEC were 426.78 and 352.09 each, which shows that the application of AEC decreases exposure dose more than standard by approximately 18%. Conclusion The results of our study show that there was no difference of AC in SPECT images based on the CT exposure dose variation at SPECT/CT images. It was found that the increased CT exposure dose leads to the improvement of CT image quality but also increases the exposure dose. Thus, the use of AEC in SPECT/CT contributes to obtaining equal AC SPECT images, and uniform noise in CT images while reducing exposure dose.

  • PDF

JTCS Software Design and Tracking Performance of NYSC 1m Telescope

  • Kang, Wonseok;Kwon, Sun-gill;Lee, Sang-Gak;Kwak, Teyun;Koo, Donghyun
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.2
    • /
    • pp.59.3-59.3
    • /
    • 2015
  • National Youth Space Center will complete installation of the NYSC 1m Telescope in this year. Before completion of the telescope, we present the software design of JTCS, and the preliminary result of tracking performance by JTCS and mount of the telescope. JTCS currently uses commercial software of the Sky X, for the real-time coordinates of various objects, such as asteroids, comets, and even satellites. In order to guarantee flexibility in CCD detectors, the MaxIm DL software was adopted and JTCS provides auto-guiding and scheduled image-taking with MaxIm DL. We are now stabilizing the telescope mount and JTCS with long-exposure tests, and gathering the preliminary data of tracking performance.

  • PDF

An Improved AE System for Mobile Digital Still Camera (모바일 디지털카메라 모듈에 대한 개선된 AE 알고리즘 구현)

  • Cho, Sun-Ho;Kim, Dong-Han;Park, Chong-Kug
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.5
    • /
    • pp.426-431
    • /
    • 2008
  • In this paper, an improved AE system for digital still camera is proposed. AE system is auto exposure system to maintain optimized brightness of output image. But there is limitation for mobile devices to get high quality image with the conventional AE algorithm, because of organizational restriction of system. The conventional research has been studied only electronic shutter and AGC on the AE algorithm. In this paper, we suggest new AE algorithm included target setting, frame delay, Gamma Correction as well as electronic shutter and AGC to get high quality image. The proposed algorithm show improved result at control speed and ability of luminance expression.

Analysis of In-Cylinder Steady Flow for Gasoline Engine Using Particle Tracking Velocimetry (입자추적법을 이용한 가솔린 기관의 실린더 내 정상유동 해석)

  • 정구섭;전충환;장영준
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.4
    • /
    • pp.34-43
    • /
    • 2001
  • Analysis and control of intake charge motion such as swirl and tumble are very important to improve the performance of gasoline engines. In this paper, single frame double exposure PTV(particle tracking velocimetry) is used to investigate intake flow characteristic in a steady flow test rig of gasoline engine with 2-valve and pent-roof combustion chamber. To validate this PTV method, we confirmed reliability of this PTV method using chopper, and coaxial burner experiments. The velocity Held of intake flow is measured with the intake valve lift variation. It is shown that maximum flow velocity is increased and tumble flow become stronger than inverse tumble flow as valve lift increase.

  • PDF

Quantitative Evaluation of Image Quality using Automatic Exposure Control & Sensitivity in the Digital Chest Image (디지털 흉부영상에서 자동노출제어 및 감도변화를 이용한 영상품질의 정량적인 평가)

  • Lee, Jin-Soo;Ko, Seong-Jin;Kang, Se-Sik;Kim, Jung-Hoon;Kim, Dong-Hyun;Kim, Changsoo
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.8
    • /
    • pp.275-283
    • /
    • 2013
  • The patient radiation dose is different depending on selection of Ion chamber when taking Chest PA which using AEC. In this paper, we studied acquiring the best diagnostic images according to selection of Ion chamber on AEC mode as well as minimizing patient radiation dose. Experimental methods were selection of Ion chamber and change of sensitivity under the same conditions as Chest PA projection. At AEC mode, two upper ion chambers sensors and one lower ion chamber sensor were divided into 7 cases according to selection of on/off. after measuring five times respectively, we obtained average value and calculated exposure dose. Image assessment was done with measured Modulation Transfer Function, Peak Signal to Noise Ratio, Root Mean Square, Signal to Noise Ratio, Contrast to Noise Ratio, Mean to Standard deviation Ratio respectively. In exposure assessment results, selection of two upper chambers was the lowest. In resolution assessment results, image of two upper chambers had the second high spatial frequency at sensitivity at 625(High) was 1.343 lp/mm. RMS value of image selecting two upper chambers was low secondly. SNR, CNR, MSR were the high value secondly. As the sensitivity was increased, radiation dose was decreased but better image could be obtained on image quality. In order to obtain the best medical images while minimizing the dose, usage of two upper ion chambers is considered to be clinically useful at sensitivity 625(High).

Implementation of color CCD Camera using DSP(GCB4101) (디지털 신호처리 칩(GCD4101)을 사용한 컬러 CCD 카메라 구현)

  • Kwon, O-Sang;Lee, Eung-Hyuk;Min, Hong-Ki;Chung, Jung-Seok;Hong, Seung-Hong
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.1
    • /
    • pp.69-79
    • /
    • 1999
  • The research and implementation was preformed on high-resolution CCTV camera with CCD exclusive DSP conventional analog signal processor CCTV camera has its limit on auto exposure(AE), auto white balance(AWB), back light compensation(BLC) processing, severe distortion and noise of image, manual control parameter setting, etc. In our study, to resolve the problems in conventional CCTV camera, we made it possible to control AE, AWB, BLC automatically by the use of the DSP, which are used exclusively in the CCD camera produced domestically, and the microcontroller. And we utilized the function of screen display of microcontroller for the user-friendly interface to control CCD camera. And the electronic variable resister(EVR) was used to avoid setting parameters manually in the level of manufacturing process. As the result, It became possible to control parameters of the camera by program. And the cost-down effect was accomplished by improving the reliability of parameter values and reducing the efforts in setting parameters.

  • PDF

Effect of Amine-Based Antioxidants as Stabilizers for Biodiesel (바이오디젤용 산화방지제인 아민안정제들의 효과)

  • Park, Soo-Youl;Kim, Hun-Soo;Kim, Seung-Hoi
    • Tribology and Lubricants
    • /
    • v.31 no.6
    • /
    • pp.258-263
    • /
    • 2015
  • Biodiesel is an environmentally-friendly fuel with low smoke emission because it contains about 10% oxygen. Biodiesel fuel prepared by transesterification of vegetable oil or animal fats is susceptible to auto-oxidation. The rate of auto-oxidation depends on the number of methylene double bonds contained within the fatty acid methyl or ethyl ester groups. Biodiesel may be easily oxidized under several conditions, i.e., upon exposure to sunlight, temperature, oxygen environment. Maintenance of the fuel quality of biodiesel requires the development of technologies to increase the resistance of biodiesel to oxidation. Treatment with antioxidants is a promising approach for extending the shelf-life or storage time of biodiesel. The chemical properties of various amine-based antioxidants were evaluated after synthesis of the antioxidants by condensation of phenylenediamine with alkylamines at room temperature. In general, the oxidative stability can be assessed based on various experimental parameters. Such parameters may include temperature, pressure, and the flow rate of air through the samples. The Rancimat method (EN14112) was selected because it is a rapid technique that requires very little sample and provides good precision for oxidative degradation analysis. Specifically, the EN 14112 technique provides enhanced efficiency for oxidative stability evaluation when a larger ester head group is utilized. Therefore, this technique was employed for evaluation of the oxidation stability of biodiesel by the Rancimat method (EN14112).

Anti-Biofilm Activity of Grapefruit Seed Extract against Staphylococcus aureus and Escherichia coli

  • Song, Ye Ji;Yu, Hwan Hee;Kim, Yeon Jin;Lee, Na-Kyoung;Paik, Hyun-Dong
    • Journal of Microbiology and Biotechnology
    • /
    • v.29 no.8
    • /
    • pp.1177-1183
    • /
    • 2019
  • Grapefruit seed extract (GSE) is a safe and effective preservative that is used widely in the food industry. However, there are few studies addressing the anti-biofilm effect of GSE. In this study, the anti-biofilm effect of GSE was investigated against biofilm-forming strains of Staphylococcus aureus and Escherichia coli. The GSE minimum inhibitory concentration (MIC) for S. aureus and E. coli were $25{\mu}g/ml$ and $250{\mu}g/ml$, respectively. To investigate biofilm inhibition and degradation effect, crystal violet assay and stainless steel were used. Biofilm formation rates of four strains (S. aureus 7, S. aureus 8, E. coli ATCC 25922, and E. coli O157:H4 FRIK 125) were 55.8%, 70.2%, 55.4%, and 20.6% at $1/2{\times}MIC$ of GSE, respectively. The degradation effect of GSE on biofilms attached to stainless steel coupons was observed (${\geq}1$ log CFU/coupon) after exposure to concentrations above the MIC for all strains and $1/2{\times}MIC$ for S. aureus 7. In addition, the specific mechanisms of this anti-biofilm effect were investigated by evaluating hydrophobicity, auto-aggregation, exopolysaccharide (EPS) production rate, and motility. Significant changes in EPS production rate and motility were observed in both S. aureus and E. coli in the presence of GSE, while changes in hydrophobicity were observed only in E. coli. No relationship was seen between auto-aggregation and biofilm formation. Therefore, our results suggest that GSE might be used as an anti-biofilm agent that is effective against S. aureus and E. coli.

A Comparative Study of Patient Dose and Image Quality according to the Presence or Absence of Grid During Chest PA Radiography using an Auto Exposure Control System (자동 노출 조절장치를 사용한 흉부 후·전 방향 방사선 검사 시 격자 유·무에 따른 환자 선량과 영상품질 비교 연구)

  • So-min Lee;Han-yong Kim;Dong-hwan Kim;Young-Cheol Joo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.573-579
    • /
    • 2023
  • This study compares dose difference between the presence or absence of grid in Chest PA radiography using auto exposure control and compares image quality among presence, absence or virtual grid, and proposes a new clinically useful grid combination for chest radiography. The human body phantom was placed Chest PA position and the dosimeter was placed at T6. The same irradiation conditions and field size were applied. 30 images were obtained in the state in which grid was applied and in the state in which grid was not applied, and an additional 30 images in which the virtual grid was applied to the image without the grid were obtained. Radiation dose was presented to entrance surface dose. The image quality was analyzed by comparing the signal-to-noise and contrast-to-noise ratio. ESD decreased by 48% when the grid was not used, compared to when the grid was used. SNR and CNR increased by 32% and 30% compared to grid use when grid was not used, respectively. In the case of using the virtual grid, it increased by 18% and 16% respectively, compared to the case of using the grid. As a result of this study, it is believed that when using a virtual grid instead of a grid, the quality of the image can be maintained while reducing the patient dose.

A Study of The Correlation of The Area Dose with Residual CT Contrast Media and MRI Contrast Media during The Use of General Imaging Automatic Exposure Control System (일반촬영 자동노출제어장치 사용 시 잔존 CT 조영제와 MRI 조영제에 따른 면적선량의 상관성 연구)

  • Hong, Chan-Woo;Park, Jin-Hun;Lee, Jung-Min;Seo, Young-Deuk
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.8
    • /
    • pp.619-627
    • /
    • 2016
  • The purpose of this study is to investigate the effect of CT contrast agent and MRI contrast agent on the area dose in the body when using automatic exposure control system in general radiography. After making rectangular holes in the center of the abdominal thickness paraffin phantom, CT contrast agent and MRI contrast agent were respectively diluted with physiological saline solution for contrast medium dilution ratio of 10:0, 9:1, 8:2, 7:3, 6:4, 5:5, 4:6, 3:7, 2:8, 1:9, 0:10%. Each experiment was set to 78 kVp, 320 mA, which is the proper condition for KUB photography, and thereafter a total of 30 inspections were made for each dilution ratio using an automatic exposure control device, and the area dose corresponding to the dilution ratio of each contrast agent, Average comparison and correlation analysis were performed on the exposure index. As a result, the CT contrast agent and the MRI contrast agent appeared different in area dose according to the dilution ratio(p<0.05), and as the dilution ratio increased, the area dose increased for CT contrast agent and MRI contrast agent(P<0.05). In each test, the exposure index showed the manufacturer's recommendation of 200-800 EI value, and the exposure index and area dose increased as the area dose increased(p<0.05). In conclusion, CT contrast agent and MRI contrast agent confirmed to increase the area dose by general imaging test using all automatic exposure control device. Therefore, it is considered that it is necessary to perform it after the contrast medium has been excreted sufficiently when using usual imaging test after using the contrast agent in CT and MRI examination.