• Title/Summary/Keyword: Audiometer

Search Result 35, Processing Time 0.035 seconds

Auditory responses in neonates; a preliminary report (신생아에서 관찰할 수 있는 청성반응)

  • 황순재;노관택
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1977.06a
    • /
    • pp.4.1-4
    • /
    • 1977
  • A variety of diagnostic means for evaluating the hearing ability of neonates and infants have been studied so far, and some physical responses of neonates and infants to loud sound is still of much value. The author studied some normal responses of 100 neonates (male 54, female 46) in our neonatal room from Jan, 1977 to April, 1977. We took 90dB pure tone at 3, 000Hz by Beltone Audiometer model l0D (ANSI 1969) for a stimulus. The results are as follows: 1. The range of the examinees' age is between 2 and 3.5 hours (average 2.4 hours), and auropalpebral response is in 39% (eyelid blinking 10%, eyelid widening 29%), Moro reflex in 35%, sucking response in 14%, cessation of movement in 6%, head turning response in 2%, and no response in 4%. 2. The duration of response is between 2 and 5 Seconds (average 3.3 seconds).

  • PDF

Development of a Békésy Audiometry System based on PC (PC 기반의 Békésy 청력검사 시스템 개발)

  • Kang, Deok-Hun;Song, Bok-Deuk;Shin, Bum-Joo;Kim, Jin-Dong;Wang, Soo-Geun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.16 no.7
    • /
    • pp.77-84
    • /
    • 2011
  • The B$\'{e}$k$\'{e}$syaudiometry makes possible to determine not only hearing threshold but also assumption of recruit phenomenon. Additionally, it is helpful to investigate cause of hearing loss. In this paper, we describe a development of PC based B$\'{e}$k$\'{e}$syaudiometer which complies with ANSI standards and provides cost competitiveness. It dynamically produces sound having required frequency and sound pressure level and supports audiogram interface showing test result at realtime. To provide ANSI defined maximum sound level, an amplifier has been developed. We have been verified our system whether it conforms to ANSI standards.

The Correlation Between Speech Reception Threshold and Pure Tone Audiometry (어음청취역치와 순음청력검사의 상관관계에 관한 연구)

  • 이철희;선우대활;민양기;백만기
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1981.05a
    • /
    • pp.38.2-39
    • /
    • 1981
  • Speech reception threshold is a base for word discrimination testing, but it also serves as a check for the reliability of pure tone audiogram. In order to investigate the correlation between SRT and PTA these tests were carried out in patients with conductive hearing loss and normal hearing, using Grason-Stadler 1702 Audiometer. The results were as follows; 1) The difference between the scores of SRT and PTA's was 2.4 dB with a range of -3.3 dB∼+8.3 dB in conductive hearing loss, and was 1.9 dB with a range of -6.7 dB∼+5 dB in normal hearing group. 2) The difference between the scores of SRT and each speech frequency of PTA was 6 dB at 500 Hz, 3 dB at 1,000 Hz and 8.8 dB at 2,000 Hz in conductive hearing loss, and 3 dB at 500Hz, 2 dB at 1,000Hz, and 5dB at 2,000Hz in normal hearing group.

  • PDF

Auditory Recognition of Digit-in-Noise under Unaided and Aided Conditions in Moderate and Severe Sensorineural Hearing Loss

  • Aghasoleimani, Mina;Jalilvand, Hamid;Mahdavi, Mohammad Ebrahim;Ahmadi, Roghayeh
    • Korean Journal of Audiology
    • /
    • v.25 no.2
    • /
    • pp.72-79
    • /
    • 2021
  • Background and Objectives: The speech-in-noise test is typically performed using an audiometer. The results of the digit-in-noise recognition (DIN) test may be influenced by the flat frequency response of free-field audiometry and frequency of the hearing aid fit based on fitting rationale. This study aims to investigate the DIN test in unaided and aided conditions. Subjects and Methods: Thirty four adults with moderate and severe sensorineural hearing loss (SNHL) participated in the study. The signal-to-noise ratio (SNR) for 50% of the DIN test was obtained in the following two conditions: 1) the unaided condition, performed using an audiometer in a free field; and 2) aided condition, performed using a hearing aid with an unvented individual earmold that was fitted based on NAL-NL2. Results: There was a statistically significant elevation in the mean SNR for the severe SNHL group in both test conditions when compared with that of the moderate SNHL group. In both groups, the SNR for the aided condition was significantly lower than that of the unaided condition. Conclusions: Speech recognition in hearing-impaired patients can be realized by fitting hearing aids based on evidence-based fitting rationale rather than by measuring it using free-field audiometry measurement that is utilized in a routine clinic setup.

Application of HHIE-S(Hearing Handicap Inventory for the Elderly-Screening version) to screening test of noise-induced hearing loss (소음성 난청 선별검사에 HHIE-S(Hearing Handicap Inventory for the Elderly-Screening version)의 적용)

  • Lee, Mi-Young;Suh, Suk-Kwon;Lee, Choong-Won
    • Journal of Preventive Medicine and Public Health
    • /
    • v.29 no.3 s.54
    • /
    • pp.539-553
    • /
    • 1996
  • The study was conducted from May to September in 1994 to investigate applicability of the Hearing Handicap Inventory for the Elderly-Screening version(HHIE-S) in parallel with the pure-tone audiometer to the initial screening test of noise-induced hearing loss(NIHL) in some noise-exposed workers. Subjects were selected by systemic sampling that took every 10th person from 6, 700 workers taking the annual occupational health examination by the department of Health Maintenance of Dongsan Hospital Keimyung University in Taegu. The authors administered the pure-tone audiometric test and self-reported questionnaire of HHIE-S including items of sociodemographic and job-related variables concurrently. The final subjects analysed were 1,019(488 males and 531 females) excluding fourteen persons who had many missing values in their questionnaires. The reliability coefficients of HHIE-S scale by Cronbach's alpha were 0.84. In the univariate analysis of hearing handicap measured by the HHIE-S, work duration, military service and the hearing threshold loss at 1KHz and 4KHz by the initial audiometer were significant in males while age, work duration and hearing threshold loss at 1KHz and 4KHz were significant in females. In the stepwise linear regression analysis, hearing threshold loss at 1KHz and 4KHz, was the only selected variable explaining the hearing handicap in males and hearing threshold loss at 1KHz and 4KHz, age, and work duration were selected in females. In ROC curves for HHIE-S scores against NIHL as gold standard which was defined by the follow-up audiogram as more than 30dB of the average of 0.5/1/2KHz and 50dB at 4KHz, the optimal cutoff for the parallel HHIE-S appeared to be 8. The results suggest that HHIE-S appeared to have some reliability and validity in this data and might be used in screening NIHL in parallel with pure-tone audiometer in noise-exposed workers.

  • PDF

The Relationship between Temporomandibular Disorders(TMD) and Ear symptoms (측두하악장애와 귀 증상과의 관계)

  • Park, Hyung-Wook;Song, Ji-Hee;Kim, Seong-Taek
    • The Journal of the Korean dental association
    • /
    • v.48 no.7
    • /
    • pp.522-530
    • /
    • 2010
  • Temporomandibular disorders(TMD) have been defined as a collective term embracing a number of clinical problems that involve the temporomandibular joint, the masticatory muscles, and associated structures. Since Dr. James Costen has mentioned about the relationship between TMD and posterior bite collapse, there have been many controversies about the etiology and comorbidities of TMD. The purpose of this study was to investigate the relationship between TMD and hearing acuity in 158 volunteers with or without TMD symptoms. The subjects were examined clinically about TMJ sound, missing teeth, tinnitus, TMJ pain and masticatory muscle pain and the hearing acuity were measured by Audiometer(ITO AE-1000, Japan). The result of this study indicated that there was no significant differences between TMD symptoms and hearing acuity relatively.

The Relationship between Temporomandibular Disorders(TMD) and Hearing Acuity (측두하악장애와 청력과의 관계)

  • Kang, Jin Kyu;Kim, Seong Taek
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.3
    • /
    • pp.187-195
    • /
    • 2007
  • Temporomandibular disorders have been defined as a collective term embracing a number of clinical problems that involve the temporomandibular joint, the masticatory muscles, and associated structures. Since Dr. James Costen has mentioned about the relationship between TMD and posterior bite collapse, there have been many controversies about the etiology and comorbidities of TMD. The purpose of this study was to investigate the relationship between TMD and hearing acuity in 158 volunteers with or without TMD symptoms. The subjects were examined clinically about TMJ sound, missing teeth, tinnitus, TMJ pain and masticatory muscle pain and the hearing acuity were measured by Audiometer(ITO AE-1000, Japan). The result of this study indicated that there was no significant differences between TMD symptoms and hearing acuity relatively.

IoT based Pure Tone Audiometer with Software Platform Compatibility (IoT 기반의 소프트웨어 플랫폼 호환성을 갖는 순음청력 검사기)

  • Kang, Sung Ho;Lee, Jyung Hyun;Kim, Myoung Nam;Seong, Ki Woong;Cho, Jin-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.21 no.2
    • /
    • pp.261-270
    • /
    • 2018
  • Hearing-impaired people are increasing rapidly due to the global aging trend. Early detection of hearing loss requires an easy-to-use audiometry device for the public. Existing audiometry systems were developed as PC-based, PDA-based, or smartphone apps. These devices were often dependent on specific software platforms and hardware platforms. In this paper, we tried to improve software platform compatibility by using cross platform, and tried to implement IoT-based pure tone audiometry device which does not require sound pressure level correction due to hardware differences. Pure tone audiometry is available in a variety of ways depending on the type of hearing loss and age. Using the IoT-based audiometry device implemented in this paper, it will be possible for an app developer who lacks hardware knowledge to easily develop an app with various scenarios for hearing screening. The results of this study will contribute to overcoming the software and hardware dependency in the development of IoT-based healthcare device.

Nursing Students' Hearing Levels and Blood Pressure Measurement Accuracy (간호대학생의 청력수준과 혈압측정의 정확도)

  • Kim, Heeyoung;Chung, Young Hae;Kim, Yun Hee
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.23 no.3
    • /
    • pp.275-282
    • /
    • 2016
  • Purpose: This study was done to examine the relationship between nursing students' hearing levels and accuracy of blood pressure (BP) measurements. Methods: Participants were 107 students who had finished their fundamental nursing practice and clinical practicum and who used earphones. Data were collected from October 13 to November 30, 2014 and from April 30 to May 19, 2015. Students' hearing thresholds were examined using an audiometer. Students were assigned to take two BP measurements on BP measurement training simulators, but only the second measurement was used for analysis. Results: All nursing students' hearing levels were within normal range, and there was no significant difference found among the settings for diastolic blood pressure. However, there were significant differences between low systolic blood pressure (SBP) (below 120mmHg) and high SBP (over 140mmHg) (z=9.02, p=.011). Measurement error in SBP showed a positive correlation with hearing threshold in the right ear at frequencies of 1000Hz and 500Hz. Conclusion: Findings indicate that BP measurement error is correlated with hearing threshold at some frequencies. To reduce measurement error, nursing students should be provided with health education about hearing and to improve training for students, further studies need to examine other factors influencing BP measurement error.

Study on Relations among Use of Earphones, Stress, and Hearing Threshold in University Students (대학생의 이어폰 사용, 스트레스 및 청력의 관계)

  • Kwak, Hye-Weon;Kim, Na-Hyun
    • Journal of Korean Public Health Nursing
    • /
    • v.26 no.1
    • /
    • pp.126-136
    • /
    • 2012
  • Purpose: The purpose of this study was to investigate the relationship among use of earphones, stress level, and hearing threshold in university students. Methods: Study subjects included 210 university students (76 men, 134 women). Data were collected by questionnaire and audiometer from December 17 to 20, 2011. The SPSS win 19.0 program was used for data analysis by descriptive statistics, t-test, one-way ANOVA, and Pearson's correlation coefficient. Results: 1) 4KHz, 6KHz hearing threshold of subjects who used earphones was higher than average hearing threshold of same age group. 2) Not significant differences in hearing threshold were observed according to frequency of use, and stress level. 3) Significant differences in 4KHz hearing threshold were observed according to earphone volume. 4) A significant positive correlation was observed between frequency of use and stress level (r=0.15, p<.05), earphone volume, and 4KHz hearing threshold (left) (r=0.15, p<.05); however, a negative correlation was observed between stress level and 4KHz hearing threshold (right) (r=-0.14, p<.05). Conclusion: A significant positive correlation was observed between frequency of use and stress level and earphone volume and 4KHz hearing threshold (left). Development of a program for hearing conservation is needed.