• 제목/요약/키워드: Attenuation relationship

검색결과 120건 처리시간 0.021초

Evaluation of neutron attenuation properties using helium-4 scintillation detector for dry cask inspection

  • Jihun Moon;Jisu Kim;Heejun Chung;Sung-Woo Kwak;Kyung Taek Lim
    • Nuclear Engineering and Technology
    • /
    • 제55권9호
    • /
    • pp.3506-3513
    • /
    • 2023
  • In this paper, we demonstrate the neutron attenuation of dry cask shielding materials using the S670e helium-4 detector manufactured by Arktis Radiation Ltd. In particular, two materials expected to be applied to the TN-32 dry cask manufactured by ORANO Korea and KORAD-21 by the Korea Radioactive Waste Agency (KORAD) were utilized. The measured neutron attenuation was compared with our Monte Carlo N-Particle Transport simulation results, and the difference is given as the root mean square (RMS). For the fast neutron case, a rapid decline in neutron counts was observed as a function of increasing material thickness, exhibiting an exponential relationship. The discrepancy between the experimentally acquired data and simulation results for the fast neutron was maintained within a 2.3% RMS. In contrast, the observed thermal neutron count demonstrated an initial rise, attained a maximum value, and exhibited an exponential decline as a function of increasing thickness. In particular, the discrepancy between the measured and simulated peak locations for thermal neutrons displayed an RMS deviation of approximately 17.3-22.4%. Finally, the results suggest that a minimum thickness of 5 cm for Li-6 is necessary to achieve a sufficiently significant cross-section, effectively capturing incoming thermal neutrons within the dry cask.

초음파를 이용한 재질열화의 비파괴적 평가 (Nondestructive Evaluation for Material Degradation of 2.25Cr-1Mo steel by Ultrasonic Wave)

  • 김정석;박은수;박인근;김현묵
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2000년도 추계학술대회논문집 - 한국공작기계학회
    • /
    • pp.369-374
    • /
    • 2000
  • This study has been achieved on the characteristics of ultrasonic wave in 2.25Cr-1Mo steel to evaluate the feasibility of ultrasonic nondestructive technique on the assessment of aging degradation. The measured values were used find a relationship between the ultrasonic propagation properties and degradation such as coarsening of carbides and precipitates. The ultrasonic attenuation coefficient was mainly affected by the grain size of prior austenitic phase as well as degradation. In this results, degradation and grain size in 2.25Cr-1Mo steel was able to cope with the changes in ultrasonic wave properties by applying the nondestructive evaluation method

  • PDF

공기중 코로나방전의 초음파신호 특성 (Ultrasonic Signal Characteristics of Corona Discharges in Air)

  • 이상우;김인식;이광식;이동인;이동헌;배상준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1702-1704
    • /
    • 1998
  • In order to establish the usefulness of ultrasonic techniques for detecting corona discharges in high-voltage power apparatus, it is first necessary to determine the relationship between electrical and ultrasonic signals of corona discharges in air. In this paper, various characteristics of ultrasonic signal detection for point-to-plane corona discharges using a 200[kHz] ultrasonic sensor are examined. In regard to the attenuation and directivity of ultrasonic signals, the signals were inversely proportional to the distance between corona sources and ultrasonic receiving sensors, and half attenuation angles were approximately 7.0 degree. Ultrasonic signals of positive polarities were first obserbed at corona inception voltages. and the signals were increased with increasing the applied voltages.

  • PDF

이종마찰용접 강봉재의 기계적특성과 비파괴 평가 (The Mechanical Properties and the Nondestructive Evaluation of Dissimilar Friction Welded Steel Bars)

  • 정원택;공유식;김선진
    • 동력기계공학회지
    • /
    • 제10권1호
    • /
    • pp.77-82
    • /
    • 2006
  • In this study, dissimilar friction welding were produced using 15mm diameter solid bar in chrome molybedenum steel(SCM440) to carbon steel(S45C) to investigate their mechanical properties and the relationship between the weld parameters and the nondestructive coefficients, such as AE counts and ultrasonic attenuation coefficient. The main friction welding parameters were selected to endure good quality welds on the basis of visual examination, tensile tests, Vickers hardness surveys of the bond of area and heat affected zone. The specimens were tested as-welded and post weld heat treated(PWHT). The tensile strength of the friction welded steel bars was increased up to 100% of the S45C base metal under the condition of all heating time. The ductility of PWHT specimens is higher than as-welded.

  • PDF

Adaptive Reconstruction Of AVHRR NVI Sequential Imagery off Korean Peninsula

  • Lee, Sang-Hoon;Kim, Kyung-Sook
    • 대한원격탐사학회지
    • /
    • 제10권2호
    • /
    • pp.63-82
    • /
    • 1994
  • Multitemporal analysis with remotely sensed data is complicated by numerous intervening factors, including atmospheric attenuation and occurrence of clouds that obscure the relationship between ground and satellite observed spectral measurements. A reconstruction system was developed to increase the discrimination capability for imagery that has been modified by residual dffects resulting from imperfect sensing of the target and by atmospheric attenuation of the signal. Utilizing temporal information based on an adaptive timporal filter, it recovers missing measurements resulting from cloud cover and sensor noise and enhances the imagery. The temporal filter effectively tracks a systematic trend in remote sensing data by using a polynomial model. The reconstruction system were applied to the AVHRR data collected over Korean Peninsula. The results show that missing measurements are typically recovered successfully and the temporal trend in vegetation change is exposed clearly in the reconstructed series.

내리막 달리기의 충격 쇼크와 신체 관절의 운동학적 특징 (Impact shock and kinematic characteristics of the lower extremity's joint during downhill running)

  • 류지선
    • 한국운동역학회지
    • /
    • 제15권4호
    • /
    • pp.117-129
    • /
    • 2005
  • The purpose of this study was to characterize the impact shock wave and its attenuation, and the kinematic response of the lower extremity's joints to the impact shock during downhill running in which the lower extremity's extensor acts dominantly. For this study, fifteen subjects(mean age:$27.08{\pm}4.39$; mass:$76.30{\pm}6.60$; height:$177.25{\pm}4.11$) were required to run on the 0% grade treadmill and downhill grades of 7%, and 15% in random at speed of their preference. When the participant run, acceleration at the tibia and the sacrum and kinematic data of the lower extremity were collected for 20s so as to provide at least 5 strides for analysis at each grade. Peak impact accelerations were used to calculate shock attenuation between the tibia and sacrum in time domain at each grade. Fast Fourier transformation(FFT) and power spectral density(PSD) techniques were used to analyze impact shock factors and its attenuation in the frequency domain. Joint coordinate system technique was used to compute angular displacement of the ankle and knee joint in three dimension. The conclusions were drawn as fellows: 1. Peak impact accelerations of the tibia and sacrum in downhill run were greater than that of 0% grade run, but no significant between conditions. Peak shock of PSD resembled also in pattern of peak impact acceleration. The wave of impact shock attenuation between the tibia and sacrum decreased with increasing grade, but didn't find a significant difference between grade conditions. 2. Adduction/abduction, flexion/extention, and internal/external rotation of the ankle and knee joints at support phase between grade conditions didn't make much difference. 3. At grade of 7% and 15%, there were relationship between the knee of the flexion/extension movement and peak impact acceleration during heel strike and found also it in the ankle of plantar/dorsiflexion at grade of 15%.

Effect of Gd-based MR contrast agents on CT attenuation of PET/CT for quantitative PET-MRI study

  • Ko, In OK;Park, Ji Ae;Lee, Won Ho;Lim, Sang Moo;Kim, Kyeong Min
    • 대한방사성의약품학회지
    • /
    • 제1권2호
    • /
    • pp.130-136
    • /
    • 2015
  • We evaluate the influence of MR contrast agent on positron emission tomography (PET) image using phantom, animal and human studies. Phantom consisted of 15 solutions with the mixture of various concentrations of Gd-based MR contrast agent and fixed activity of [$^{18}F$]FDG. Animal study was performed using rabbit and two kinds of MR contrast agents. After injecting contrast agent, CT or MRI scanning was performed at 1, 2, 5, 10, and 20 minutes. PET image was obtained using clinical PET/CT scan, and attenuation correction was performed using the all CT images. The values of HU, PET activity and MRI intensity were obtained from ROIs in each phantom and organ regions. In clinical study, patients (n=20) with breast cancer underwent sequential acquisitions of early [$^{18}F$]FDG PET/CT, MRI and delayed PET/CT. In phantom study, as the concentration increased, the CT attenuation and PET activity also increased. However, there was no relationship between the PET activity and the concentration in the clinical dose range of contrast agent. In animal study, change of PET activity was not significant at all time point of CT scan both MR contrast agents. There was no significant change of HU between early and delayed CT, except for kidney. Early and delayed SUV in tumor and liver showed significant increase and decrease, respectively (P<0.05). Under the condition of most clinical study (< 0.2 mM), MR contrast agent did not influence on PET image quantitation.

Improved Plasmonic Filter, Ultra-Compact Demultiplexer, and Splitter

  • Rahimzadegan, Aso;Granpayeh, Nosrat;Hosseini, Seyyed Poorya
    • Journal of the Optical Society of Korea
    • /
    • 제18권3호
    • /
    • pp.261-273
    • /
    • 2014
  • In this paper, metal insulator metal (MIM) plasmonic slot cavity narrow band-pass filters (NBPFs) are studied. The metal and dielectric of the structures are silver (Ag) and air, respectively. To improve the quality factor and attenuation range, two novel NBPFs based on tapered structures and double cavity systems are proposed and numerically analyzed by using the two-dimensional (2-D) finite difference time domain (FDTD) method. The impact of different parameters on the transmission spectrum is scrutinized. We have shown that increasing the cavities' lengths increases the resonance wavelength in a linear relationship, and also increases the quality factor, and simultaneously the attenuation of the wave transmitted through the cavities. Furthermore, increasing the slope of tapers of the input and output waveguides decreases attenuation of the wave transmitted through the waveguide, but simultaneously decreases the quality factor, hence there should be a trade-off between loss and quality factor. However, the idea of adding tapers to the waveguides' discontinuities of the simple structure helps us to improve the device total performance, such as quality factor for the single cavity and attenuation range for the double cavity. According to the proposed NBPFs, two, three, and four-port power splitters functioning at 1320 nm and novel ultra-compact two-wavelength and triple-wavelength demultiplexers in the range of 1300-1550 nm are proposed and the impacts of different parameters on their performances are numerically investigated. The idea of using tapered waveguides at the structure discontinuities facilitates the design of ultra-compact demultiplexers and splitters.

Biot 파동전파 이론을 이용한 지반의 투수계수 산정 (Estimation of Hydraulic Conductivity of Soils Based on Biot's Theory of Wave Propagation)

  • 송정락;김진원
    • 한국지반공학회논문집
    • /
    • 제36권12호
    • /
    • pp.7-16
    • /
    • 2020
  • 본 연구는 음향학적 기법을 이용하여 지반의 투수계수를 산정하는 새로운 방법을 제시하였다. 연구를 위하여 Biot의 특성 진동수(Characteristic Frequency) 와 지반의 투수계수의 연관성이 포화된 지반에서만 나타나는 것을 확인할 수 있도록 음파의 감쇠 및 전파속도 특성을 포화된 시료와 건조된 시료에 대하여 측정/비교 하였다. 본 연구에서의 시험결과는 특성 진동수는 포화된 지반에서만 나타나며, 음파의 감쇠 특성으로 부터 얻은 특성 진동수와 전파속도 특성으로 부터 얻은 특성 진동수가 서로 매우 유사한 범위를 나타내었다. 한편 음파의 전파속도로 부터 얻은 결과가 감쇠 특성으로부터 얻은 결과보다 판독성이 좀 더 좋은 것으로 나타났다. 또한 본 시험결과를 동일한 시료에 대한 정수위 투수시험결과와 비교했을때 서로가 합리적으로 상응하는 결과를 나타내었으며, 본 연구에서 사용된 음향학적 기법이 사질토 또는 실트질 사질토의 투수계수를 구할 수 있는 비파괴 시험으로 사용될 수 있는 가능성을 보여 주었다.

비소로 오염된 달천광산 토양의 자연저감 능력에 대한 pH-Eh영향 (Effects of pH-Eh on Natural Attenuation of Soil Contaminated by Arsenic in the Dalchen Mine Area, Ulsan, Korea)

  • 박맹언;성규열;이민희;이평구;김민철
    • 자원환경지질
    • /
    • 제38권5호
    • /
    • pp.513-523
    • /
    • 2005
  • 울산 달천광산의 지하수 및 토양 중에 함유되어 있는 비소의 오염현황을 파악하고, pH와 산화-환원 전위 값의 변화에 따른 자연저감 능력을 평가하였다. 달천광산 지역 비소 오염의 주 근원광물인 유비철석의 광미 내 함량은 최대 $2\%$이며, 비독사석, 니콜라이트, 램멜스버가이트, 거스도르파이트, 코발트석과 황철석 등의 비소함유광물 역시 비소오염의 근원이 되고 있으며, 비소함량은 광물에 따라 다양한 차이를 보인다 광미장 내 유비철석과 황철석의 표면이 부분적으로 철산화물과 철비산염으로 산화된 것을 관찰할 수 있어, 풍화반응이 상당히 진행되었음을 알 수 있다. 지하수 내 비소의 함량과 pH는 뚜렷한 상관관계를 보이지 않지만, 포화대 및 비포화대의 지하수의 비소 농도는 Eh가 감소함에 따라 농도가 감소하는 정(+)의 상관관계를 보인다. RMB(Red Mud Bauxite)는 비소제거 효율이 우수하여 달천광산 지역의 비소로 오염된 지하수 및 토양을 복원 시 자연저감 촉진제로 이용될 수 있을 것이다.