• 제목/요약/키워드: Attenuation parameters

검색결과 320건 처리시간 0.024초

Comparative Study of Linear and Nonlinear Ultrasonic Techniques for Evaluation Thermal Damage of Tube-Like Structures

  • Li, Weibin;Cho, Younho;Li, Xianqiang
    • 비파괴검사학회지
    • /
    • 제33권1호
    • /
    • pp.1-6
    • /
    • 2013
  • Ultrasonic guided wave techniques have been widely used for long range nondestructive detection in tube-like structures. The present paper investigates the ultrasonic linear and nonlinear parameters for evaluating the thermal damage in aluminum pipe. Specimens were subjected to thermal loading. Flexible polyvinylidene fluoride (PVDF) comb transducers were used to generate and receive the ultrasonic waves. The second harmonic wave generation technique was used to check the material nonlinearity change after different heat loadings. The conventional linear ultrasonic approach based on attenuation was also used to evaluate the thermal damages in specimens. The results show that the proposed experimental setup is viable to assess the thermal damage in an aluminum pipe. The ultrasonic nonlinear parameter is a promising candidate for the prediction of micro-damages in a tube-like structure.

Compact Low-Pass Filter with Sharp Skirt Characteristics and Broad Stopband

  • Li, Rui;Kim, Dong-Il;Choi, Chang-Mook
    • 한국항해항만학회지
    • /
    • 제30권7호
    • /
    • pp.607-610
    • /
    • 2006
  • A new compact microstrip low-pass filter and its equivalent-circuit model are developed. The philosophy of the structure behind this novel microstrip low-pass filter is simple as it is composed of a pair of symmetrical parallel coupled-line and an open-stub. With this configuration, a finite attenuation pole near the stopband cutoff frequency is available and adjustable by simply tuning the circuit parameters. Furthermore, the rejection bandwidth of this type of low-pass filter can be extended. In order to validate the feasibility of the proposed design method, a low-pass filter based on a microstrip structure is designed, fabricated, and measured. Experimental results agree very well with the simulation and analytical results.

$2{\mu}m$CMOS 5차 Elliptic OTA-C 필터 설계 (Design of 5th-Order Elliptic Filter in $2{\mu}m$ CMOS)

  • Shin, Gun-Soon
    • 대한전기학회논문지
    • /
    • 제43권4호
    • /
    • pp.672-678
    • /
    • 1994
  • A design of 5th-order Elliptic OTA-C filter for operation at 4.2MHz is presented. the filter structure is composed entirely of five OTAs(Operational transoonductance Amplifiers), one buffer and seven capacitors. To prevent decreasing of frequency charaoteristios due to the parasitic effeots of OTA and buffer, the design considering of parasitic capacitance and finite resistane of OTA and fuffer is pertormed. As the result of the simulation using SPICE with $2{\mu}m$ CMOS parameters, The performances were found to be essentially within the specifications` less than 0.25dB passband attenuation, 30dB stopband attenuation and 4.2MHz cut-off frequency were satisfactorily obtained. The number of elements is also considerably reduced than other design methods.

A Novel Design of Compact Low-Pass Filter and Its Equivalent Circuit Model

  • Li, Rui;Kim, Dong-Il;Choi, Chang-Mook;Song, Young-Man
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2006년도 Asia Navigation Conference
    • /
    • pp.79-84
    • /
    • 2006
  • A novel design of compact low-pass filter based on microstrip structure and its equivalent-circuit model are developed. The philosophy of the structure behind this novel microstrip low-pass filter is simple as it is composed of a pair of symmetrical parallel coupled-line and an open-stub. With this configuration, a finite attenuation pole near the stopband cutoff frequency is available and adjustable by simply tuning the circuit parameters. Furthermore, the rejection bandwidth of this type of low-pass filter can be extended. In order to validate the feasibility of the proposed design method, a low-pass filter based on a microstrip structure is designed, fabricated, and measured. Experimental results agree very well with the simulation and analytical results.

  • PDF

세탁기 모터다이의 방사음 저감을 위한 설계해석 (The Design Analysis for the Reduction of Radiated Sound from the Motor-die in Washing Machine)

  • 서대원;홍정혁;오재응
    • 소음진동
    • /
    • 제9권2호
    • /
    • pp.371-376
    • /
    • 1999
  • The purpose of this study is to identify the dynamic characteristics of a motor-die in washing machine and provide quantitative design information needed for reduction of radiated sound from the motor-die. To perform the design analysis, dynamic characteristics are identified by motor-die modeling and the availability of model is verified by experimental modal analysis. Numerical approach using MSC/NASTRAN and SYSNOISE predicted sound attenuation effects according to the change of design parameters, such as thickness, concentrated mass and rib. The numerical results due to the rib attachment showed the significant noise attenuation effects over 15 dB in the frequency range of 450∼700 Hz.

  • PDF

세탁기 모터다이의 방사음 저감을 위한 설계해석 (The Design Analysis for the Reduction of Radiated Sound from the Motor-die in Washing Machine)

  • 오재응
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.23-32
    • /
    • 2000
  • The purpose of this study is to identify the dynamic characteristics of a motor-die in washing machine and provide quantitative design information needed for the reduction of radiated sound from the motor-die. To perform the design analysis, dynamic characteristics are identified by motor-die modeling and the availability of model is verified by experimental modal analysis. Numerical approach using MSC/NASTRAN and SYSNOISE predicted sound attenuation effects according to the change of design parameters, such as thickness, concentrated mass and rib. The numerical results due to the rib attachment showed the significant noise attenuation effects over 15dB in the frequency range of 450-700Hz.

  • PDF

골다공증 진단을 위한 초음파 변수의 골밀도에 대한 의존성 (Dependences of Ultrasonic Parameters for Osteoporosis Diagnosis on Bone Mineral Density)

  • 황교승;김윤미;박종찬;최민주;이강일
    • 비파괴검사학회지
    • /
    • 제32권5호
    • /
    • pp.502-508
    • /
    • 2012
  • 현재 골다공증 진단을 위하여 임상에서 이용되고 있는 정량적 초음파 기술은 종골(발뒤꿈치뼈)에서 음속(speed of sound; SOS) 및 광대역 초음파 감쇠(normalized broadband ultrasound attenuation; nBUA)와 같은 초음파 변수를 측정한다. 본 연구에서는 소 대퇴골로부터 제작된 20개의 해면질골 샘플을 이용하여 골절 위험도가 높은 대퇴골에서 SOS 및 nBUA의 골밀도에 대한 의존성을 살펴보았다. 대퇴골 해면질골 샘플의 SOS 및 nBUA는 1.0 MHz의 중심주파수를 갖는 한 쌍의 초음파 트랜스듀서와 함께 투과법을 이용하여 측정 하였다. 20개의 해면질골 샘플에서 측정된 SOS 및 nBUA는 골밀도와 각각 r = 0.83 및 0.72라는 높은 Pearson 상관계수 (r)를 갖는 것으로 나타났다. 또한 SOS 및 nBUA를 독립변수로 하고, 골밀도를 종속변수로 하는 다중선형회귀분석으로부터 다중선형회귀모델의 상관계수는 r = 0.85로서 SOS 또는 nBUA 중 하나만을 독립변수로 하는 단순선형회귀모델의 상관계수보다 높게 나타났다. 이와 같이 초음파 변수와 골밀도 사이의 높은 선형적인 상관관계는 대퇴골에서 측정된 초음파 변수가 대퇴골의 골밀도를 예측하기에 충분한 지표라는 것을 의미한다.

초음파를 이용한 연골(軟骨)의 강도 평가 (Evaluation of Trabecular Bone Strength Using Ultrasound)

  • 한승무;김문생
    • 비파괴검사학회지
    • /
    • 제18권5호
    • /
    • pp.373-380
    • /
    • 1998
  • 본 연구에서는 초음파 속도와 광역 감쇠를 이용하여 연골의 강도를 평가하였다. 먼저 60개의 시편을 인체의 연골로부터 얻어서 초음파 속도와 광역 감쇠를 각 시편에 대하여 측정하였다. 시편들은 동일한 두개의 그룹으로 나누어, $0.0004\;s^{-1}$$0.08\;s^{-1}$의 변형률에서 압축 하중을 작용시킨 후 각 시편에 대한 최대 압축 강도값을 결정하였다. 그 결과, $0.08\;s^{-1}$에서 측정된 시편들은 $0.0004\;s^{-1}$로 측정된 시편들 보다 63%나 더 높은 평균 강도값을 나타내었다. 초음파 속도와 광역 감쇠는 고변형률 및 저변형률 모두에서 골 강도와 밀접한 연관성을 나타내었다. 또한, 골 강도는 모든 변형률에서 초음파 속도와 광역 감쇠의 선형 조합과도 밀접한 관련성을 보였다 초음파 파라미터의 사용은 여러 가지 골절에 대한 연골의 저항능력을 평가하기 위한 임상진단법으로 훌륭한 수단이 될 수 있을 것이다.

  • PDF

NEP-AKARI: EVOLUTION WITH REDSHIFT OF DUST ATTENUATION IN 8 ㎛ SELECTED GALAXIES

  • Buat, V.;Oi, N.;Burgarella, D.;Malek, K.;Matsuhara, H.;Murata, K.;Serjeant, S.;Takeuchi, T.T.;Malkan, M.;Pearson, C.;Wada, T.
    • 천문학논총
    • /
    • 제32권1호
    • /
    • pp.257-261
    • /
    • 2017
  • We built a $8{\mu}m$ selected sample of galaxies in the NEP-AKARI field by defining 4 redshift bins with the four AKARI bands at 11, 15, 18 and 24 microns (0.15 < z < 0.49, 0.75 < z < 1.34, 1.34 < z < 1.7 and 1.7 < z < 2.05). Our sample contains 4079 sources, 599 are securely detected with Herschel/PACS. Also adding ultraviolet (UV) data from GALEX, we fit the spectral energy distributions using the physically motivated code CIGALE to extract the star formation rate, stellar mass, dust attenuation and the AGN contribution to the total infrared luminosity ($L_{IR}$). We discuss the impact of the adopted attenuation curve and that of the wavelength coverage to estimate these physical parameters. We focus on galaxies with a luminosity close the characteristic $L^*_{IR}$ in the different redshift bins to study the evolution with redshift of the dust attenuation in these galaxies.

높은 감쇠 정확도를 가지는 초광대역 MMIC 디지털 감쇠기 설계 (Design of Ultra Wide Band MMIC Digital Attenuator with High Attenuation Accuracy)

  • 주인권;염인복
    • 한국전자파학회논문지
    • /
    • 제17권2호
    • /
    • pp.101-109
    • /
    • 2006
  • 본 논문은 광대역, DC to 40 GHz 5-bit MMIC 디지털 감쇠기의 설계 및 측정 결과를 나타내었다. 초광대역 감쇠기는 종래의 Switched-T 감쇠기에 전송 선로를 추가하고 전송 선로의 파라미터를 최적화하여 구현되었다. 고주파에서의 정확한 성능 예측을 위해 Momentum 시뮬레이션을 설계에서 수행하였고, 몬테 카를로 해석법을 적용하여 MMIC 공정 변동에 대한 성능의 안정성을 검증하였다. 감쇠기는 $0.15\;{\mu}m$ GaAs pHEMT 공정을 이용하여 제작하였다. 이 감쇠기는 1 dB의 해상도와 총 23 dB의 감쇠 동작 범위를 가진다. 전체 감쇠 범위와 40 GHz의 대역폭에서 높은 감쇠 정확도를 얻었으며, 20 GHz에서 6 dB 이하의 참조 상태 삽입 손실을 가진다. 전체 감쇠 상태와 주파수 범위에서 감쇠기의 입력단과 출력단 반사 손실은 14 dB 이상이다. 감쇠기의 IIP3는 33 dBm으로 측정되었다.