• 제목/요약/키워드: Attenuation coefficient

검색결과 437건 처리시간 0.023초

Homomorphic Deconvolution 법에 의한 초음파 감쇄정수 추정 (Estimation of Ultrasound Attenuation Coefficient by Homomorphic Deconvolution Method)

  • 홍승홍;허웅
    • 대한의용생체공학회:의공학회지
    • /
    • 제5권1호
    • /
    • pp.39-46
    • /
    • 1984
  • In order to improve the performance of ultrasonic diagnostic equipment, it is important to development the signal processing considering the ultrasonic properties of biological medium and propagation mechanism in tissue. Attenuation coefficient is not only important factor to analyze propagation properties, but also it is significant to estimate it in view of tissue characterization, so we show one of the method to estimate attenuation coefficient of biological tissue and the results of estimation.

  • PDF

접착부재의 초음파 감쇠계수에 의한 계면균열 길이의 측정 (Measurement of Interfacial Crack Length by Ultrasonic Attenuation Coefficients on Adhesively Bonded Components)

  • 정남용;박성일
    • 한국자동차공학회논문집
    • /
    • 제12권1호
    • /
    • pp.130-137
    • /
    • 2004
  • The ultrasonic attenuation coefficients were measured by interfacial crack length in the adhesive components of double-cantilever beam(DCB). The energy release rate, G, was obtained by the experimental measurement of compliance. The numerical analysis by the boundary element method(BEM) and Ripling's equation was investigated. The experimental results represent that the relation between interfacial crack length for the ultrasonic attenuation coefficient and energy release rate is increased proportionally. A measurement method of the interfacial crack length by the ultrasonic attenuation coefficient was proposed and discussed.

Seasonal Variation of Attenuation Coefficient Spectra Extracted from Yamato Bank Optical Moored Buoy Data

  • Senga, Yasuhiro;Horiuchi, Tomohiro
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 1998년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.89-94
    • /
    • 1998
  • Seasonal variation of attenuation coefficient spectra in Japan sea was extracted from underwater radiance/irradiance spectra observed by a moored buoy system developed by National Space Development Agency of Japan (NASDA). The buoy was deployed 9 months from August 31, 1996 to June 1, 1997. Throughout this period, it was collecting downward irradiance and upward radiance spectra under water at the depth of 1.5m and 6.5m everyday. The dairy averaged diffused attenuation coefficient spectra and underwater reflectance spectra were calculated. The results were compared with the absorption spectra of filtered samples obtained by validation cruises, which carried out 5 times during the moored period. Also, the natural fluorescence of chlorophyll a were extracted from the upward radiance spectra observed at 1.5m depth. The seasonal variation of the calculated attenuation coefficient spectra and the natural fluorescence were examined. The result shows a weak blooming of phytoplankton on November and a large blooming on April.

  • PDF

초음파 특성을 이용한 경년열화 평가 (Aging Degradation Assessment of Materials by Ultrasonic Characterization)

  • 박은수;박익근;김덕희;안형근
    • 비파괴검사학회지
    • /
    • 제22권2호
    • /
    • pp.149-154
    • /
    • 2002
  • 실제 사용 온도 보다 높은 $630^{\circ}C$에서 열처리 시간을 변수로 하여 최대 1000 시간 동안 등온 열처리를 통해 2.25Cr-1Mo 강의 경년열화재를 제작하고 열화에 따른 미세조직과 기계적 특성 변화에 대한 초음파 비파괴평가 법으로 표면 특성평가에 우수한 표면 SH파를 적용하였다. 열화에 따른 초음파의 감쇠와 전파시간 및 웨이블렛을 이용한 음속과 감쇠계수의 주파수 의존성평가를 수행한 결과 열화가 진행됨에 따라서 탄화물은 점차 조대화되고 경도는 감소하였다. 감쇠계수는 열화시간이 증가함에 따라서 증가하였고 전파시간 역시 열화의 초기단계에 급격히 증가했다. 초음파의 감쇠와 경도와는 좋은 상관관계를 나타내어 감쇠계수는 경년열화 평가에 중요한 파라미터임을 알 수 있었다.

A Study of Shielding Properties of X-ray and Gamma in Barium Compounds

  • Seenappa, L.;Manjunatha, H.C.;Chandrika, B.M.;Chikka, Hanumantharayappa
    • Journal of Radiation Protection and Research
    • /
    • 제42권1호
    • /
    • pp.26-32
    • /
    • 2017
  • Background: Ionizing radiation is known to be harmful to human health. The shielding of ionizing radiation depends on the attenuation which can be achieved by three main rules, i.e. time, distance and absorbing material. Materials and Methods: The mass attenuation coefficient, linear attenuation coefficient, Half Value Layer (HVL) and Tenth Value Layer (TVL) of X-rays (32 keV, 74 keV) and gamma rays (662 keV) are measured in Barium compounds. Results and Discussion: The measured values agree well with the theory. The effective atomic numbers ($Z_{eff}$) and electron density (Ne) of Barium compounds have been computed in the wide energy region 1 keV to 100 GeV using an accurate database of photon-interaction cross sections and the WinXCom program. Conclusion: The mass attenuation coefficient and linear attenuation coefficient for $BaCO_3$ is higher than the $BaCl_2$, $Ba(No_3)_2$ and BaSO4. HVL, TVL and mean free path are lower for $BaCO_3$ than the $BaCl_2$, $Ba(No_3)_2$ and $BaSO_4$. Among the studied barium compounds, $BaCO_3$ is best material for x-ray and gamma shielding.

STUDY ON THE EFFECT OF THE SELF-ATTENUATION COEFFICIENT ON γ-RAY DETECTOR EFFICIENCY CALCULATED AT LOW AND HIGH ENERGY REGIONS

  • El-Khatib, Ahmed M.;Thabet, Abouzeid A.;Elzaher, Mohamed A.;Badawi, Mohamed S.;Salem, Bohaysa A.
    • Nuclear Engineering and Technology
    • /
    • 제46권2호
    • /
    • pp.217-224
    • /
    • 2014
  • The present work used the efficiency transfer method used to calculate the full energy peak efficiency (FEPE) curves of the (2"*2" & 3"*3") NaI (Tl) detectors based on the effective solid angle subtended between the source and the detector. The study covered the effect of the self attenuation coefficient of the source matrix (with a radius greater than the detector's radius) on the detector efficiency. $^{152}$ An Eu aqueous radioactive source covering the energy range from 121.78 keV up to 1408.01 keV was used. In this study an empirical formula was deduced to calculate the difference between the measured and the calculated efficiencies [without self attenuation] at low and high energy regions. A proper balance between the measured and calculated efficiencies [with self attenuation] was achieved with discrepancies less than 3%, while reaching 39% for calculating values [without self attenuation] due to working with large sources, or for low photon energies.

광감쇄를 이용한 마모입자의 농도 측정 (Wear Debris Concentration Measurement by Laser Beam Attenuation)

  • 강기호;손정영;전형욱;윤의성;안효석
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1990년도 제12회 학술강연회초록집
    • /
    • pp.58-62
    • /
    • 1990
  • The size and concentration of wear debris in lubricating oil often reveal the operating condition of the rotating machinery. To evaluate the possible application of light attenuation measurement for the estimation of wear debris concentration in the lubricating oil, the light transmittance through the lubricating oil cell contaminated with various concentrations of diatomite particles was measured, the attenuation coefficient was estimated from the transmittance measurement and the coefficients were compared with those obtained from the scattering theory. The comparision showed good agreements between them. It is also noted that the experimentally determined attenuation coefficient showed almost linear relation with particle weight concentrations for the concentrations within the range of 2000 ppm. For the case of 0 ppm weight concentration of diatomite particles in the lubricating oil cell, the thickness of the cell required to give $100 \mu W$ light attenuation is 7.75 mm. This result indicates that the light attenuation method will be one of the possible candidates of machine failure diagnostic sensors for the estimation of wear debris concentration in the lubricating oil.

  • PDF

광감쇄를 이용한 마모입자의 농도 측정 (Wear Debris Coacentration Measurement by Laser Beam Attenuation)

  • 강기호;손정영;전형욱;윤의성;안효석
    • Tribology and Lubricants
    • /
    • 제6권2호
    • /
    • pp.94-98
    • /
    • 1990
  • The size and concentration of wear debris in lubricating oil often reveal the operating condition of the rotating machinery. To evaluate the possible application of light attenuation measurement for the estimation of wear debris concentration in the lubricating oil, the light transmittance through the lubricating oil cell contaminated with various concentrations of diatomire particles was measured, the attenuation coefficient was estimated from the transmittance measurement and the coefficients were compared with those obtained from the scattering theory. The comparision showed good agreements between them. It is also noted that the experimentally determined attenuation coefficient showed almost linear relation with particle weight coucentrations for the concentrations within the range of 2000 ppm. For the case of 0 ppm weight concentration of diatomire particles in the lubricating oil cell, the thickness of the cell required to give $100 \muW$ light attenuation is 7.75 mm. This result indicates that the light attenuation method will be one of the possible candidates of machine failure diagnostic sensors for the estimation of wear debris concentration in the lubricating oil.

AAPM CT 성능 팬텀의 CT영상에서 물 유효선감쇠계수의 백분율에 의한 노이즈 측정 (Noise Measurement by Percentage of Effective Linear Attenuation Coefficient of Water in CT Image of AAPM CT Performance Phantom)

  • 김종언;이상훈
    • 한국방사선학회논문지
    • /
    • 제16권6호
    • /
    • pp.771-778
    • /
    • 2022
  • 이 연구의 목적은 임상에서 AAPM CT 성능 팬텀을 이용한 CT영상 노이즈 정도관리에 사용할 수 있는 물 유효선감쇠계수의 백분율에 의한 노이즈 측정의 방법을 제시하는 데 있다. 120 kVp CT X-선 빔으로 AAPM CT 성능 팬텀을 스캔하여 얻어진 CT영상에서, CT수 직선성 삽입부분의 각 핀과 물에 대하여 평균 CT수를 측정하였다. 유효에너지는 각 핀과 물에 대하여 측정된 평균 CT수와 광자에너지별 선감쇠계수의 선형회귀분석의 상관계수들로부터 가장 큰 상관계수를 갖는 광자에너지로 결정하였다. 그리고 물과 아크릴에 대하여 측정된 평균 CT수와 유효선감쇠계수로부터 대조도 척도는 0.000188 cm-1 · HU-1으로 산출되었다. 산출된 대조도 척도, 물 유효선감쇠계수, 그리고 AAPM CT 성능 팬텀에서 고정핀 부분의 물에서 측정된 표준편차를 사용하여, 물 유효선감쇠계수의 백분율에 의한 노이즈 측정값은 100 ~ 300 mAs의 범위에서 0.31 ~ 0.52%를 얻었다.

Acoustic Properties of Rubber Compound for Anechoic Coating

  • Bae, Jong Woo;Kim, Won Ho;Ahn, Byung Hyun
    • Elastomers and Composites
    • /
    • 제53권4호
    • /
    • pp.195-201
    • /
    • 2018
  • Three kinds of rubber compounds were prepared, and their underwater acoustical properties were investigated for anechoic coating. Dynamic mechanical properties of the rubber compounds were measured using a dynamic mechanical analyzer and extended to 100 kHz using time-temperature superposition. The sound speed, reflection coefficient, and attenuation constant were calculated. Silicone rubber showed the lowest reflection coefficient, and nitrile rubber showed the highest attenuation constant. The acoustic properties of nitrile rubber compounds with various compositions were investigated. The sound speed, reflection coefficient, and transmission coefficient of the nitrile rubber in the frequency range of 200-1000 kHz were measured in a water-filled tank.