• Title/Summary/Keyword: Attached Dust Mass Per Unit Area

Search Result 1, Processing Time 0.016 seconds

Preliminary Study on Dust Removal by Electrode-Plate Coated with Activated Carbon (활성탄전극의 분진제거에 대한 기초연구)

  • Kim, Kwang Soo;Park, Hyun Chul;Jun, Tae Hwan;Lee, Ju Haeng;Kim, Il Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.10
    • /
    • pp.749-755
    • /
    • 2013
  • The purposes of this research are to know the optimal gab and electric pressure (voltage) of electrode-plates coated with activated carbon and also to study their arrangement through dust removal efficiency. From the experimental results of attached dust mass at different electrode-plate gab, the frequency of attachment and detachment of dust was more increased as electrode-plate gab was closer. In attached dust mass per unit area of electrode-plate, the farther electrode gab, the more increased. But in total attached dust mass, the closer electrode gab, the more removed. From the experimental results, the optimal electrode arrangement in dust removal chamber was considered that the forward parts of chamber need to be increased the number of electrode-plate, the backward parts to be increased them. The dust attachment have no relation with electric pressure while showing high removal efficiency under condition of 5 kV of voltage and 2 cm of electrode-plates gab.