• 제목/요약/키워드: Atrial flutter

검색결과 24건 처리시간 0.028초

The Difference of Left Atrial Volume Index : Can It Predict the Occurrence of Atrial Fibrillation after Radiofrequency Ablation of Atrial Flutter?

  • Kim, Ung;Kim, Young-Jo;Kang, Sang-Wook;Song, In-Wook;Jo, Jung-Hwan;Lee, Sang-Hee;Hong, Geu-Ru;Park, Jong-Seon;Shin, Dong-Gu
    • Journal of Yeungnam Medical Science
    • /
    • 제24권2호
    • /
    • pp.197-205
    • /
    • 2007
  • Background : The occurrence of atrial fibrillation after ablation of atrial flutter is clinically important. We investigated variables predicting this evolution in ablated patients without a previous atrial fibrillation history. Materials and Methods : Thirty-six patients (Male=28) who were diagnosed as atrial flutter without previous atrial fibrillation history were enrolled in this study. Group 1 (n=11) was defined as those who developed atrial fibrillation after atrial flutter ablation during 1 year follow-up. Group 2 (n=25) was defined as those who has not occurred atrial fibrillation during same follow-up term. Echocardiogram was performed to all patients. We measured left atrial size, left ventricle end diastolic and systolic dimension, ejection fraction and left atrial volume index before and after ablation of atrial flutter. The differences of each variables were compared and analyzed between two groups. Results : The preablation left ventricular ejection fraction (preLVEF) and postablation left ventricular ejection fraction (postLVEF) are $54{\pm}14%$, $56{\pm}13%$ in group 1 and $47{\pm}16%$, $52{\pm}13%$ in group 2. The differences between each two groups are statistically insignificant ($2.2{\pm}1.5$ in group 1 vs $5.4{\pm}9.8$ in group 2, p=0.53). The preablation left atrial size (preLA) and postablation left atrial size (postLA) are $40{\pm}4mm$, $41{\pm}4mm$ in group1 and $44{\pm}8mm$, $41{\pm}4mm$ in group 2. The atrial sizes of both groups were increased but, the differences of left atrial size between two groups before and after flutter ablation were statistically insignificant ($0.6{\pm}0.9mm$ in group 1 vs $-3.8{\pm}7.4mm$ in group 2, p=0.149). The left atrial volume index before flutter ablation was significantly reduced in group 1 than group 2 ($32{\pm}10mm^3/m^2$, $35{\pm}10mm^3/m^2$ in group 1 and $32{\pm}10mm^3/m^2$, $29{\pm}8mm^3/m^2$ in group 2, p<0.05). Conclusion : The difference between left atrial volume index before and after atrial flutter ablation is the robust predictor of occurrence of atrial fibrillation after atrial flutter ablation without previous atrial fibrillation.

  • PDF

태아 심초음파 검사로 진단 된 뒤 출생 후 Propafenone으로 치유된 신생아 심방조동 1례 (A Case of Neonatal Atrial Flutter Treated by Propafenone after Fetal Echocardiographic Diagnosis)

  • 이경화;하창우;김철호;송민섭;성문수
    • Clinical and Experimental Pediatrics
    • /
    • 제45권7호
    • /
    • pp.928-932
    • /
    • 2002
  • 저자들은 재태 연령 $38^{+6}$주에 태아 심초음파 검사에 의해 태아 심방 조동이 발견되어 산모에게 digoxin을 투여하였으나 효과가 없어 제왕 절개술을 통해 분만한 후, digoxin, 전기적 심율동 전환에 의해서도 치료되지 않아 propafenone을 복용하여 정상 동율동으로 회복된 1례를 경험하였기에 문헌 고찰과 함께 보고하는 바이다.

소풍보심도담탕(疎風補心導痰湯) 합(合) 생맥산(生脈散) 투여 후 임상증상 및 심전도 상 심방조동이 호전된 환자 1례 (A Case Report of Improvement of Clinical Symptoms and Atrial Flutter on the Electrocardiogram (EKG) Treated with Xiaofengbusindaotantang (疎風補心導痰湯) and Shengmaisan (生脈散))

  • 김동현;임인환;유경환;나병조;이범준
    • 대한한방내과학회지
    • /
    • 제27권3호
    • /
    • pp.784-790
    • /
    • 2006
  • Most of the atrial flutter occurs in patients who have an organic disease of the heart. The symptoms of atrial flutter include anxiety with palpitation. sleep disorder and fatigue. For a long time, oriental medicine has clinically treated these symptoms, and the diagnosis has been usually based on the doctor's judgment on the subjective clinical symptoms. However, if oriental medicine includes new diagnostic aids like electrocardiogram or other various methods or combinations of techniques, the accuracy and objectivity of diagnosis and clinical data can be improved. In this case, a 65 year-old male patient who had anxiety with palpitation and abnormal P wave (atrial flutter) on the EKG was treated with Xiaofengbusindaotantang (疎風補心導痰湯) and Shengmaisan (生脈散). Significant improvement in the clinical symptoms and EKG results was observed. This result suggests that oriental medical treatment can be used for treatment of organic heart disease like an atrial flutter. In addition, subsequent studies should be followed to ensure the appropriateness of new diagnostic aids, such as EKG, and other various modalities.

  • PDF

불테리어종 개에서 발생한 미약한 심실반응이 있는 심방조동 (Atrial Flutter with Poor Ventricular Response in a Bull Terrier Dog)

  • 이준석;한숙희;현창백
    • 한국임상수의학회지
    • /
    • 제27권4호
    • /
    • pp.435-439
    • /
    • 2010
  • 6살된 암컷 불테리어종 개 (체중 17 kg)가 운동 불내성과 실신증상으로 내원하였다. 진단검사를 통해 특발성 심근확장증에 의한 심방조동과 완전 방실차단 증례로 진단되었다. 환자는 심근증에 대한 일반적인 치료와 dofetilide를 포함한 항부정맥 치료를 통해 11개월간 관리되었다. 하지만 환자는 갑작스런 심장마비로 폐사하였다.

승모판막 수술 환자에서 발생한 부정맥의 치료 (Therapy for Postoperative Cardiac Arrhythmia in Patient with Mitral Valve Surgery)

  • 조건현
    • Journal of Chest Surgery
    • /
    • 제25권6호
    • /
    • pp.672-677
    • /
    • 1992
  • This is a clinical review of the results from electric cardioversion and pharmacological therapy used in our hospital for reverting cardiac arrythmia in patients with mitral valve surgery between Jan. 1990 and Jun. 1991. Of 62 evaluated patients, 16 patients had regular sinus rhythm and the other 46 had arrhythmias [42; atrial fibrillation 1; atrial flutter 1; premature ventricular contraction] preoperatively. In 2 of patients with sinus rhythm, atrial fibrillation newly developed after surgery and was converted into sinus rhythm soon by intravenous administration of digoxin. Remaining 14 patient resumed sinus rhythm spontaneously. In patients with preoperative arrythmia, 3 patients reverted into sinus rhythm from atrial fibrillation by electric cardioversion at operative field, 1 patient by lidocain and mexiletine, 4 patients by combined use of digoxin and verapamil, 4 patients by 2 times of oral quinidine and 9 patient by long term use of oral amiodarone. Throughout this consecutive trials of anti-arrhythmic drugs and electric cardioversion, Conversion into normal sinus rhythm occurred in 48% of patients with arrhythmia developed after mitral valve surgery.

  • PDF

마이크로 컴퓨터를 이용한 다중 채널 심장 전기도 시스템 개발 (Development of Multi-Channel Cardiac Mapping System Using Microcomputer)

  • 장병철;김원기;김남현;정성헌
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1991년도 춘계학술대회
    • /
    • pp.94-97
    • /
    • 1991
  • It is well known that multipoint and computerized intraoperative mapping systems improve the results of surgery for Wolff-Parkinson-White syndrome and show tremendous potential for opening an entirely new era of surgical intervention for the more common and lethal types of supraventricular tachyarrhythmias such as atrial flutter and atrial fibrillation. In addition, the ability to map and ablate the sometimes fleeting automatic atrial tachycardia is greatly enhanced by computerized mapping systems. In this study, we have developed 16 channel computerized data analysis system using microcomputer for basic research of electrophysiology and electrical propagation. This system is expected to enable us to study pathophysiology of cardiac arrhythmia and to improve the results of diagnosis and surgical treatment for cardiac arrhythmia.

  • PDF

Surgical and Electrical Anatomy of the Inter-Nodal and Intra-Atrial Conduction System in the Heart

  • Seo, Jeong-Wook;Kim, Jung-Sun;Cha, Myung-Jin;Yoon, Ja Kyoung;Kim, Min-Ju;Tsao, Hsuan-Ming;Lee, Chang-Ha;Oh, Seil
    • Journal of Chest Surgery
    • /
    • 제55권5호
    • /
    • pp.364-377
    • /
    • 2022
  • An anatomical understanding of the atrial myocardium is crucial for surgeons and interventionists who treat atrial arrhythmias. We reviewed the anatomy of the inter-nodal and intra-atrial conduction systems. The anterior inter-nodal route (#1) arises from the sinus node and runs through the ventral wall of the atrial chambers. The major branch of route #1 approaches the atrioventricular node from the anterior aspect. Other branches of route #1 are Bachmann's bundle and a vestibular branch around the tricuspid valve. The middle inter-nodal route (#2) begins with a broad span of fibers at the sinus venarum and extends to the superior limbus of the oval fossa. The major branch of route #2 joins with the branch of route #1 at the anterior part of the atrioventricular node. The posterior inter-nodal route (#3) is at the terminal crest and gives rise to many branches at the pectinate muscles of the right atrium and then approaches the posterior atrioventricular node after joining with the vestibular branch of route #1. The branches of the left part of Bachmann's bundle and the branches of the second inter-nodal route form a thin myocardial network at the posterior wall of the left atrium. These anatomical structures could be categorized into major routes and side branches. There are 9 or more anatomical circles in the atrial chambers that could be structural sites for macro re-entry. The implications of normal and abnormal structures of the myocardium for the pathogenesis and treatment of atrial arrhythmias are discussed.

Initial Experience with Total Thoracoscopic Ablation

  • Lee, Hee Moon;Chung, Su Ryeun;Jeong, Dong Seop
    • Journal of Chest Surgery
    • /
    • 제47권1호
    • /
    • pp.1-5
    • /
    • 2014
  • Background: Recently, a hybrid surgical-electrophysiological (EP) approach for confirming ablation lines in patients with atrial fibrillation (AF) was suggested. The aim of this approach was to overcome the limitations of current surgery- and catheter-based techniques to yield better outcomes. Methods: Ten consecutive patients with AF underwent total thoracoscopic ablation (TTA) following transvenous catheter EP ablation (residual gap and cavotricuspid isthmus [CTI] ablation). Holter monitoring was performed 6 months postoperatively. Results: Ten patients (90% with persistent AF) underwent successful hybrid procedures, and there was no in-hospital mortality. An EP study was performed in 8 patients and showed that successful antral ablation in all pulmonary veins was achieved in 7 of them. The median follow-up duration was 7.63 months (range, 6.7 to 11.6 months). Nine patients underwent Holter monitoring 6 months postoperatively, and the results indicated an underlying sinus rhythm without AF, atrial flutter, or atrial tachycardia lasting more than 30 seconds in all of the patients. There was no recurrence of AF during follow-up. Conclusion: A hybrid approach that consists of TTA followed by transvenous catheter EP ablation (residual gap and CTI ablation) yielded excellent outcomes in our patient population. A hybrid approach should be considered in patients with a high risk of AF recurrence.

64채널 심장전기도 시스템 구현에 관한 연구 (64 channels computerized cardiac mapping system)

  • 장병철;김남현
    • 대한의용생체공학회:의공학회지
    • /
    • 제16권1호
    • /
    • pp.107-113
    • /
    • 1995
  • It is well known that multipoint and computerized intraoperative mapping systems improve the results of surgery for Wolff-Parkinson-White syndrome and show tremendous potential for opening an entirely new era of surgical intervention for the more common and lethal types of supraventricular tachyarrhythmias such as atrial flutter and atrial fibrillation. In addition, the ability to map and ablate the sometimes fleeting automatic atrial tachycardia is greatly enhanced by computerized mapping systems. In this study, we have developed 64 channel computerized data analysis system using microcomputer (Macintosh ${II}_{x}$) for basic research of electrophysiology and electrical propagation. The bipolar electrogram information is acquired from 64 cardiac sites simultaneously at a sampling rate of 1 ksampls/sec with continuous and total data storage of up to 30 seconds. When the reference electrogram is selected and reference point is picked up, delay time from the reference point is displayed on two dimensional diagram of the heart. System design permits easy expansion to almost 256 simultaneous sites. this system is expected to enable us to study pathophysiology of cardiac arrhythmia and to improve the result of diagnosis and surgical treatment for cardiac arrhythmia.

  • PDF

스퀴드 심자도 장치를 이용한 심방성 부정맥의 측정 (Detection of Rapid Atrial Arrhythmias in SQUID Magnetocardiography)

  • 김기웅;권혁찬;김기담;이용호;김진목;김인선;임현균;박용기;김두상;임승평
    • Progress in Superconductivity
    • /
    • 제7권1호
    • /
    • pp.28-35
    • /
    • 2005
  • We propose a method to measure atrial arrhythmias (AA) such as atrial fibrillation (Afb) and atrial flutter (Afl) with a SQUID magnetocardiograph (MCG) system. To detect AA is one of challenging topics in MCG. As the AA generally have irregular rhythm and atrio-ventricular conduction, the MCG signal cannot be improved by QRS averaging; therefore a SQUID MCG system having a high SNR is required to measure informative atrial excitation with a single scan. In the case of Afb, diminished f waves are much smaller than normal P waves because the sources are usually located on the posterior wall of the heart. In this study, we utilize an MCG system measuring tangential field components, which is known to be more sensitive to a deeper current source. The average noise spectral density of the whole system in a magnetic shielded room was $10\;fT/{\surd}Hz(a)\;1\;Hz\;and\;5\;fT/{\surd}Hz\;(a)\;100\;Hz$. We measured the MCG signals of patients with chronic Afb and Afl. Before the AA measurement, the comparison between the measurements in supine and prone positions for P waves has been conducted and the experiment gave a result that the supine position is more suitable to measure the atrial excitation. Therefore, the AA was measured in subject's supine position. Clinical potential of AA measurement in MCG is to find an aspect of a reentry circuit and to localize the abnormal stimulation noninvasively. To give useful information about the abnormal excitation, we have developed a method, separative synthetic aperture magnetometry (sSAM). The basic idea of sSAM is to visualize current source distribution corresponding to the atrial excitation, which are separated from the ventricular excitation and the Gaussian sensor noises. By using sSAM, we localized the source of an Afl successfully.

  • PDF