• 제목/요약/키워드: Atomic absorption analysis

검색결과 274건 처리시간 0.029초

Indirect Determination of Nitrite by Flame Atomic Absorption Spectrometry Using a Lead(IV) Dioxide Oxidant Microcolumn

  • Noroozifar, Meissam;Khorasani Motlagh, Mozhgan;Taheri, Aboozar;Homayoonfard, Marjan
    • Bulletin of the Korean Chemical Society
    • /
    • 제27권6호
    • /
    • pp.875-880
    • /
    • 2006
  • A new, simple and fast flow injection analysis (FIA) method has been developed for the indirect determination of nitrite. The proposed indirect automatic method is based on the oxidation of nitrite to nitrate using a lead(IV) dioxide oxidant microcolumn where the flow of the sample through the microcolumn reduces the $PbO_2$ solid phase reagent to Pb(II), which is measured by flame atomic absorption spectrometry. The absorbance of Pb(II) are proportional to the concentration of nitrite in the samples. The calibration curve was linear up to 30 mg $L ^{-1}$, with a detection limit of 0.11 mg $L ^{-1}$ for a 400 mL injected sample volume and a sampling rate of about 80 $h ^{-1}$. The results exhibit no interference from the presence of large amounts of ions. The developed procedure was found to be suitable for the determination of nitrite in foodstuffs and wastewaters. A relative standard deviation better than 0.9% was obtained in a repeatability study. The reliability of the method was established by parallel determination against the standard method.

흑연료 원자흡수 분광법에 의한 혈중의 납, 카드뮴 정량을 위한 외부정도관리 시료제조 및 분석 (Preparation and analysis of lyophilized whole blood as external quality control materials for Pb and Cd determination by graphite furnace atomic absorption spectrometry)

  • 이공주;임흥빈
    • 분석과학
    • /
    • 제8권3호
    • /
    • pp.273-279
    • /
    • 1995
  • 납과 카드뮴을 포함하는 여러 가지 농도의 동결건조된 혈액이 외부정도관리 시료로서 제조되었다. 이 시료들은 흑연료 원자흡수분광법(GFAAS)을 이용하여 성능이 파악되었다. 매트릭스 개선제로서 0.1% ammonium dihydrogen phosphate와 0.1% Triton X-100을 사용하여 섭씨 600 내지 650도의 회화온도에서 혈액에 있는 납과 카드뮴의 정량 분석을 위한 GFAAS의 최적 분석조건이 얻어졌다. 제조된 혈액의 균질도와 안정도는 최적화된 분석조건에서 연구되었다.

  • PDF

사고시 논으로 유출된 핵종 이동 모델 및 실험결과와의 비교 (Model for Transport of Accidently Released Radionuclides onto Rice-Fields and its Comparison with Experimental Data)

  • 금동권;이한수;최희주;강희석;임광묵;최용호;이창우
    • Journal of Radiation Protection and Research
    • /
    • 제29권2호
    • /
    • pp.117-127
    • /
    • 2004
  • 핵종 누출 사고시 논으로의 핵종 이동 평가를 위한 동적격실모델을 개발하였다. 개발된 모델에는 벼 재배에 필수적인 관개수를 고려하여 표면수 격실과 줄기기부흡수 개념을 도입하였고, 이식 전 쟁기질과 관개담수에 의한 토양 혼합을 고려하였으며, 벼 성장에 따른 뿌리흡수상수, 줄기기부흡수상수의 변화를 생체량의 함수로 모델링하였다. 모델의 타당성 조사를 위해 고리, 영광 및 울진 원자력 발전소 주변 지역에서 채취한 논 토양으로 벼를 재배하면서 벼 생육단계별로 수행된 $^{137}Cs$ 모의 침적 실험 해석에 모델을 적용하였다. 모델은 대체적으로 한 승수 내에서 실험 결과와 잘 일치하였다.

Trace elements analysis in some medicinal plants using graphite furnace-atomic absorption spectroscopy

  • Anal, Jasha Momo H.;Chase, Petevino
    • Environmental Engineering Research
    • /
    • 제21권3호
    • /
    • pp.247-255
    • /
    • 2016
  • Ten trace elements (Mg, Ca, V, Cr, Mn, Fe, Cu, Zn, Mo, and Cd) were determined in seven traditionally used wild medicinal plants of the Nagas in the North-East India viz Cynoglossum furcatum Wallich, Elsholtzia blanda Bentham, Lycopodium cernuum Linnaeus, Potentilla fulgens Wallich ex Hooker, Swertia macrosperma C.B. Clarke, Thalictrum foliolosum DC and Valeriana jatamansi Jones. Plant samples were dried, weighed, digested and analyzed for their mineral distribution level ranging from trace to major elements by graphite furnace-atomic absorption spectroscopy. All the medicinal herbs studied were found to contain the ten elements analyzed. The elemental concentration is given in mg/kg. Mg and Ca are present in high concentrations in both the roots and leaves of the plant samples. Among trace transition metals Fe had the highest concentration, followed by Mn, Cr, Cu, V, Zn, and Mo. Analysis showed that the toxic Cd element was at a lower concentration and is within the permissible limit of FAO/WHO, California standards and United States Pharmacopeia Limit for Nutritional Supplements.

Effect of radiation model on simulation of water vapor - hydrogen premixed flame using flamelet combustion model in OpenFOAM

  • Kim, Sangmin;Kim, Jongtae
    • Nuclear Engineering and Technology
    • /
    • 제54권4호
    • /
    • pp.1321-1335
    • /
    • 2022
  • This study was conducted to investigate the effect of absorption coefficient models on the P1 radiation model for a premixed hydrogen flame containing the water vapor. A CFD combustion simulation analysis was performed using XiFoam, one of the open-source CFD solvers in OpenFOAM. The solver using the flamelet combustion model has been modified to implement radiative heat transfer. The absorption coefficient models used in this study the grey-mean model and constant model, and for comparison, case without radiation was added. This CFD simulation study consisted of benchmarking the THAI HD-15 and HD-22 experiments. The difference between the two tests is the inclusion of water vapor in the condition before ignition. In the case of the HD-22 experiment containing water vapor in the initial condition, the simulation results show that the grey-mean absorption coefficient model has a strong influence on the temperature decrease of the flame and on the change in pressure inside the vessel.

토양 시료 중 Atomic Absorption Spectrometry (AAS) 및 Inductively Coupled Plasma-Atomic Emission Spectrometry (ICP-AES)를 이용한 총 크롬 분석방법 비교 (Comparison of analytical methods for quantifying total chromium in soil using Atomic Absorption Spectrometer (AAS) and Inductively Coupled Plasma-Atomic Emission Spectrometry (ICP-AES))

  • 이홍길;김지인;변윤주;김현구;윤정기
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제22권6호
    • /
    • pp.22-28
    • /
    • 2017
  • The accuracy of analytical results in response to the use of different additives ($NH_4Cl$, KCl, $LaCl_3$) and oxidant gases was evaluated and compared by using Atomic Absorption Spectrometry (AAS). Identification of spectroscopic interferences and possible improvements in Inductively Coupled Plasma-Atomic Emission Spectrometry (ICP-AES) analysis were also discussed. The average accuracies of total chromium using Certified Reference Materials (CRMs) were found to be 72.1~94.2% in air/acetylene flame condition by AAS, and they were improved to 100.5~110.5% when the oxidants was changed to nitrous oxide rather than adding the additives. The field samples showed similar trends to CRMs, but chromium concentrations were highly variable depending on analytical conditions. The average accuracies using CRMs were estimated to be 89.3~166.1% by ICP-AES, and improved to below 121.7% after eliminating iron interference. Field samples with low chromium and high iron concentration were measured to be > 30% lower in total chromium concentrations by ICP-AES than AAS in nitrous oxide/acetylene flame. Total chromium concentrations in soil could be analyzed with better accuracy under nitrous oxide/acetylene flame by AAS because it was more effective to increase the temperature of the flame than to eliminate the chemical interference for maximizing atomization of chromium. When using ICP-AES, interference substances, total chromium levels, and analytical conditions should be also considered.

INAA.ICP.AAS를 이용한 대기먼지 $(PM_{10})$의 다원소분석 (Multielement Analysis in Airborne Particulate Matter $(PM_{10})$ by INAA, ICP and AAS)

  • 정용삼;문종화;정영주;박광원;이길용;윤윤열;심상권;조경행;한명섭
    • 한국대기환경학회지
    • /
    • 제15권4호
    • /
    • pp.495-503
    • /
    • 1999
  • Airborne particulate matter $(PM_{10})$ collected using high volume air sampler and silica fiber filter were analyzed by Instrumental Neutron Activation Analysis(INAA), Inductively Coupled Plasma Atomic Emission Spectrometry(ICP-AES) and Atomic Absorption Spectrometry(AAS), and the results were compared with each other. 30~40 trace elements in environmental standard reference materials(NIST SRM 1648 and NIES CRM No.8) were analyzed for the analytical quality control. The relative error for two-third of elements detected was less than 10%, and the standard deviation was less than 15%. During the sampling period for 24 hours, the mass concentration of total suspended particulate was 36.1$\mu\textrm{g}$/㎥ and the value is lower than the critical level in Korea. In the results of NAA, the elements of Al, As, Ba, Fe, La, Mg, Na, Sb, Zn were well agreed with those of other methods. In statistical estimation between different methods, the deviation of Al, Ba, Cr, Fe was less than 10% and quite reliable.

  • PDF

Matrix Modification for Graphite Furnace Atomic Absorption Spectrophotometric Determination of Volatile Elements(III) Trace Bismuth

  • Kim, Young-Sang;Choi, Jong-Moon;Kim, Young-Man
    • 분석과학
    • /
    • 제8권4호
    • /
    • pp.435-442
    • /
    • 1995
  • A matrix modification was studied for the determination of trace bismuth in water samples by graphite furnace atomic absorption spectrophotometry. The type and quantity of modifiers as well as the use of auxiliary modifiers were investigated to realize the efficient modification. Palladium was chosen as a single modifier. By the addition of palladium($5{\mu}g/mL$) to 100 ng/mL bismuth solution, the temperatures could be raised from $500^{\circ}C$ to $1,300^{\circ}C$ for the charring and from $2,000^{\circ}C$ to $2,200^{\circ}C$ for the atomization as well as the sensitivity and reproducibility were improved. The absorbance of bismuth was maximum and not changed in the range of Pd $3-25{\mu}g/mL$. And several materials were examined as an auxiliary modifier. The mixed solution of $1{\mu}g/mL$ palladium and $200{\mu}g/mL$ nickel have raised the temperatures as with $5{\mu}g/mL$ palladium only. The maximum absorbance of bismuth was shown in the nickel concentration range of $100-300{\mu}g/mL$ in $1{\mu}g/mL$ palladium modified system. With such optimum conditions, the trace amount of bismuth in several water samples could be determined by a calibration curve method, and good recoveries were also obtained.

  • PDF

Characterization of uranium species in molten salt : An application of synchrotron-based XAFS spectroscopy

  • Cho, Young-Hwan;Choi, In-Kyu;Kim, Won-Ho
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 2002년도 추계학술발표회요약집
    • /
    • pp.319.2-319
    • /
    • 2002
  • Synchrotron-based X-ray absorption spectroscopy has been applied to determine the changes in bulk oxidation state of uranium oxides in molten salt. From an analysis of XANES data, one can determine the cahnges in bulk oxidation-state of U compounds in salts(LiCl/KCl). XAFS spectroscpy is a powerful tool for probing the changes in valence state and structure of uranium compounds in colten salt as well as in noncrystalline form and doped in other matrices.

  • PDF