• 제목/요약/키워드: Atmospheric temperature and humidity

검색결과 282건 처리시간 0.028초

미세입자(PM2.5)의 질산염 (NO3-) 휘발 특성 분석 -서울시 4개 측정지역을 중심으로- (Characteristics of Nitrate (NO3-) Volatilization from Fine Particles (PM2.5) at 4 Measurement Sites in Seoul)

  • 김유정;정성운;강충민;마영일;김수향;우정헌;선우영
    • 한국대기환경학회지
    • /
    • 제24권5호
    • /
    • pp.613-621
    • /
    • 2008
  • The purpose of this study is to understand the impact that temperature and relative humidity have on the volatilization loss of particulate nitrate $(NO_3^-)$ from Teflon filters during measurements of ambient fine particles $(PM_{2.5})$. Fine particles $(d_p<2.5{\mu}m)$ were measured using an annular denuder system (ADS) at four representive areas in Seoul. The measurements were made during 28 different days at 24-hr sampling intervals from February 14 to October 15, 1997. In this study, nitrate losses. calculated by the ratio of nitrate on the nylon filter to their sum in both Teflon and nylon titters, varied seasonally in the following order: summer (45.5%) > spring (23.8%) > fall (20.6%) > winter (19.7%). The results showed strong correlations with temperature, but we did not observe any significant effects of relative humidity. However, we observed that both temperature and relative humidity influenced the ambient gas/particle nitrate ratio in a different case study using a denuder.

한반도 동해안 지방의 기후 특성 (Characteristics of Climate in the Eastern Coastal Regions of Korean Peninsula)

  • 김영섭;한영호;신수경;홍성근
    • 한국수산과학회지
    • /
    • 제27권3호
    • /
    • pp.314-325
    • /
    • 1994
  • Characteristics of climate in the eastern coastal regions of Korean Peninsula were studied using the meteorological and coastal sea surface temperature (SST) data which were compiled from 1961 to 1990. In the winter half year (from October to March), air temperature (AT) and precipitation of the eastern coastal regions were considerably higher than those of the western and inland regions, but relative humidity was $8{\sim}15\%$ lower. AT of coastal regions was closely related to the variation of coastal SST. These characteristics were more noticeable in the eastern coastal areas and in lower latitude regions. Quantitatively, the $1.0^{\circ}C$ variation of coastal SST may have resulted in the $1.0^{\circ}C{\sim}1.5^{\circ}C$ variation for AT in coastal regions. In the same way as temperature, vapor pressure in coastal regions was also influenced by coastal SST. Relative humidity change corresponding to the $1.0^{\circ}C$ variation of coastal SST was $3.7\%{\sim}6.5\%$. Net heat exchange amounts were positive (sea surface gaining energy) in all coastal regions. Sea surface gained net heat from March to September, and lost it from October to February. Variation of AT in coastal regions was also related to the sensible and latent heat exchanges. Sensible and latent heat amount corresponding to the $1.0^{\circ}C$ variation of AT were $10Wm^{-2}$ at Kangnung, and $8Wm^{-2}$ at Pohang and $13Wm^{-2}$ at Pusan.

  • PDF

드론을 이용한 대기환경정보 수집장치 개발 및 응용 연구 (Development of atmospheric environment information collection system using drone)

  • 김남호
    • 스마트미디어저널
    • /
    • 제7권4호
    • /
    • pp.44-51
    • /
    • 2018
  • 본 연구는 이동 및 휴대가 용이함과 더불어 지표로 부터 0~1km 높이의 특정한 위치에서의 환경정보를 수집하기 위하여 드론을 이용하였으며, 드론에 장착할 수 있는 대기환경 정보 수집기를 만들어 대기 중의 환경정보를 모니터링 하는 방안을 제안한다. 기상적인 요소로 온도와 습도를 측정하고, 환경적인 요소로 미세먼지와 $CO_2$를 관측하여 정상적인 값을 받을 수 있도록 하였다. 측정을 통하여 특정 기업, 공단, 지역의 대기가스 배출현황을 모니터링 함으로써 오염요인을 줄이는 정책수립에 도움을 줄 수 있도록 하였다. 그 동안 배기가스 검출은 굴뚝에 설치된 구멍에 검시자가 직접 접근하여 측정하다보니 안전상 많은 위험에 노출되었으나 제안하는 드론을 이용하게 되면 안정성 확보와 더불어 광범위한 정보수집이 가능하여 보다 정확한 정보수집과 다양한 산업적 활용이 가능함을 확인하였다.

KLAPS를 이용한 한반도 어는비 사례 연구 (Case Studies on Freezing Rain over the Korean Peninsula Using KLAPS)

  • 권희내;변희룡;박창균
    • 대기
    • /
    • 제25권3호
    • /
    • pp.389-405
    • /
    • 2015
  • In this study, the occurrence circumstances of 3 cases (12 Jan 2006, 11 Jan 2008, 22 Feb 2009) when the freezing rain was observed at more than two observatories in a day with more than three times each observatory, were investigated. Following the advanced study about the same cases, we have tried to find more delicate differences in using the Korea Local Analysis and Prediction System (KLAPS; 5 km reanalysis data) that has the smallest grid scale at current situation. As results, three common characteristics are found: (1) Just before the occurrence of the freezing rain, the wind direction was consistently continuous and the wind speed was constant or gradually increased for at least 3 hr more. (2) Surface air temperature (Relative humidity) was respectively $3.08^{\circ}C$ (28.76%), $0.47^{\circ}C$ (50.07%) and $-3.60^{\circ}C$ (71.07%) 3 hr ago to break out the freezing rain. It means the freezing rain occurs in a wide range of atmospheric environments. However, the closer it got to the occurrence time of the freezing rain, the closer the surface air temperature was to $0^{\circ}C$, and the bigger the humidity of the surface air was. (3) The liquid precipitation formed in the upper atmosphere, met a cold advection bellower than 950 hPa level and suspected to be changed to the super-cooled condition.

Influence of Diverse Atmospheric Conditions on Optical Properties of a Pulse Laser in a Time-of-Flight Laser Range Finder

  • Shim, Young Bo;Kwon, Oh-Jang;Choi, Hyun-Yong;Han, Young-Geun
    • Journal of the Optical Society of Korea
    • /
    • 제19권1호
    • /
    • pp.1-6
    • /
    • 2015
  • We investigate the propagation characteristics of a pulse laser in a time-of-flight laser range finder (TOF-LRF) system with variations in atmospheric conditions, such as temperature, pressure, relative humidity, and the concentration of $CO_2$. The measurement error of distance related with the group velocity change in the TOF-LRF system is analyzed by considering the refractive index of the standard atmosphere with variations in atmospheric conditions. The dependence of the pulse width broadening induced by chromatic dispersion of the standard atmosphere on the operating wavelength and the initial pulse width of the light sources is discussed. The transmission of air with variations in the relative humidity or the concentration of $CO_2$ is analyzed by using different values of absorption coefficients depending on the operation wavelength of the light source in the TOF-LRF system.

지표면의 특성을 고려한 대기경계층내의 열수지 parameter 추정 -열수지 parameter를 이용한 중규모 순환의 수치예측- (Estimation of the Heat Budget Parameter in the Atmospheric Boundary Layer considering the Characteristics of Soil Surface)

  • 이화운;정유근
    • 한국환경과학회지
    • /
    • 제5권6호
    • /
    • pp.727-738
    • /
    • 1996
  • An one dimensional atmosphere-canopy-soil interaction model is developed to estimate of the heat budget parameter in the atmospheric boundary layer. The canopy model is composed of the three balance equations of energy, temperature, moisture at ground surface and canopy layer with three independent variables of Tf(foliage temperature), Tg(ground temperature), and qg(ground specific humidity). The model was verilied by comparative study with OSUID(Oregon State University One Dimensional Model) proved in HAPEX-MOBILHY experiment. Also we applied this model in two dimensional land-sea breeze circulation. According to the results of this study, surface characteristics considering canopy acted importantly upon the simulation of meso-scale circulation. The factors which used in the numerical experiment are as follows ; the change for a sort of soil(sand and peat), the change for shielding factor, and the change for a kind of vegetation.

  • PDF

Estimation of the optimal heated inlet air temperature for the beta-ray absorption method: analysis of the PM10 concentration difference by different methods in coastal areas

  • Shin, So Eun;Jung, Chang Hoon;Kim, Yong Pyo
    • Advances in environmental research
    • /
    • 제1권1호
    • /
    • pp.69-82
    • /
    • 2012
  • Based on the measurement data of the particulate matter with an aerodynamic diameter of less than or equal to a nominal 10 ${\mu}m$ (PM10) by the ${\beta}$-ray absorption method (BAM) equipped with an inlet heater and the gravimetric method (GMM) at two coastal sites in Korea, the optimal inlet heater temperature was estimated. By using a gas/particle equilibrium model, Simulating Composition of Atmospheric Particles at Equilibrium 2 (SCAPE2), water content in aerosols was estimated with varying temperature to find the optimal temperature increase to make the PM10 concentration by BAM comparable to that by GMM. It was estimated that the heated air temperature inside the BAM should be increased up to $35{\sim}45^{\circ}C$ at both sites. At this temperature range, evaporation of volatile aerosol components was minor. Similar ($30{\sim}50^{\circ}C$) temperature range was also obtained from the calculation based on the absolute humidity which changed with ambient absolute humidity and chemical composition of hygroscopic species.

Tethered-Balloon Package System 개발 및 대기 에어로졸의 연직 분포 측정 (Development of Tethered-Balloon Package System for Vertical Distribution Measurement of Atmospheric Aerosols)

  • 은희람;이홍규;이양우;안강호
    • 한국입자에어로졸학회지
    • /
    • 제9권4호
    • /
    • pp.253-260
    • /
    • 2013
  • For a vertical atmospheric aerosol distribution measurement, a very compact and light particle sampling package is developed. This package includes a compact optical particle counter (Hy-OPC), a light and small condensation particle counter (Hy-CPC), sensors (GPS, wind velocity, temperature, humidity), and a communication and system control board. This package is attached to He balloon and the altitude is controlled by a winch. Using this system the vertical particle size distribution was measured. The test results showed that the ground base atmospheric particle measurement result may be a lot different from that high above the ground.

2003년 여름철 서울의 도시열섬 (Urban Heat Islands in Seoul during the Summertime of 2003)

  • Kim Yeon-Hui;Eom Hyang-Hui;O Seong-Nam;Kim Sang-Baek
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 2003년도 추계학술대회 논문집
    • /
    • pp.503-503
    • /
    • 2003
  • Urban heat islands related with Cheongyecheon restoration in Seoul metropolitan area for the summertime of 2003. To investigate the spatial and temporal structure of the urban heat island in Seoul, temperature data measured at 32 automatic weather stations (AWSs) in the Seoul metropolitan area and 12 additional stations operated by the portable device for the measurement of temperature and relative humidity in the Cheonggyecheon area. (omitted)

  • PDF

UM 자료를 이용한 노면온도예측모델(UM-Road)의 개발 (Development of Road Surface Temperature Prediction Model using the Unified Model output (UM-Road))

  • 박문수;주승진;손영태
    • 대기
    • /
    • 제24권4호
    • /
    • pp.471-479
    • /
    • 2014
  • A road surface temperature prediction model (UM-Road) using input data of the Unified Model (UM) output and road physical properties is developed and verified with the use of the observed data at road weather information system. The UM outputs of air temperature, relative humidity, wind speed, downward shortwave radiation, net longwave radiation, precipitation and the road properties such as slope angles, albedo, thermal conductivity, heat capacity at maximum 7 depth are used. The net radiation is computed by a surface radiation energy balance, the ground heat flux at surface is estimated by a surface energy balance based on the Monin-Obukhov similarity, the ground heat transfer process is applied to predict the road surface temperature. If the observed road surface temperature exists, the simulated road surface temperature is corrected by mean bias during the last 24 hours. The developed UM-Road is verified using the observed data at road side for the period from 21 to 31 March 2013. It is found that the UM-Road simulates the diurnal trend and peak values of road surface temperature very well and the 50% (90%) of temperature difference lies within ${\pm}1.5^{\circ}C$ (${\pm}2.5^{\circ}C$) except for precipitation case.