• Title/Summary/Keyword: Atmospheric sampling

Search Result 417, Processing Time 0.026 seconds

A Study on color characteristic of PM10 sample filter in ambient air sampling (대기중 PM10 포집여지의 색도특성에 관한 연구)

  • 정상진;장재철;심순섭
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2002.11a
    • /
    • pp.284-285
    • /
    • 2002
  • 입자상 오염물에 대한 대기 환경기준이 인체에 미치는 영향과 관련하여 총부유분진에서 PM10(10 미크론 이하의 입자) 및 PM2.5(2.5 미크론 이하 입자)의 미세입자 농도 범위로 변화되고 있다. 따라서 이들 미세입자 농도를 측정할 수 있는 정밀 측정법의 개발이 요구되고 있고 이들 측정기의 수요도 늘어갈 전망이다. (중략)

  • PDF

Effects of Cone Dimension on the Cyclone Performance

  • R.B. Xiang;Park, S.H.;Lee, K.W.
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2000.04a
    • /
    • pp.221-223
    • /
    • 2000
  • Cyclones are among the oldest types of industrial particulate control equipment and air sampling device. Until now, a great number of experimental studies have been performed on cyclones. In these studies, almost all of the eight cyclone dimensions were varied and Changes in cyclone performance produced by these variations were studied. However, very little information is available on the effects of the cone bottom diameter. (omitted)

  • PDF

Characteristics of Organic Carbon Species in Atmospheric Aerosol Particles at a Gwangju Area During Summer and Winter (여름 및 겨울철 광주지역 대기 에어로졸 입자의 유기탄소 특성)

  • Park, Seung-Shik;Hur, Jai-Young;Cho, Sung-Y.;Kim, Seung-J.;Kim, Young-Joon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.6
    • /
    • pp.675-688
    • /
    • 2007
  • To characterize organic and elemental carbon (OC and EC), and water-soluble organic carbon (WSOC) contents, daily $PM_{2.5}$ measurements were performed in August 2006 (summer) and Jan $11{\sim}Feb$ 12 2007 (winter) at an urban site of Gwangju. Daily size-segregated aerosol samples were also collected for WSOC analysis. No clear seasonal variations in EC and WSOC concentrations were observed, while seasonal differences in OC concentration, and OC/EC and WSOC/EC ratios were shown. The WSOC/OC ratio showed higher value in summer (0.56) than in winter (0.40), reflecting the greater enhancement of secondary WSOC formation at the site in summer. Secondary WSOC concentrations estimated using EC tracer method were in the range $0.0{\sim}2.1\;{\mu}g/m^3$ (average $0.42\;{\mu}g/m^3$) and $0.0{\sim}1.1\;{\mu}g/m^3\;(0.24\;{\mu}g/m^3)$, respectively, accounting for $0{\sim}51.6%$ (average 16.8%) and $0{\sim}52.5%$ (average 13.1 %) of the measured WSOC concentrations in summer and winter. Sometimes higher WSOC/OC ratio in winter than that in summer could be attributed to two reasons. One is that the stable atmospheric condition often appears in winter, and the prolonged residence time would strengthen atmospheric oxidation of volatile organic compounds. The other is that decrease of ambient temperature in winter would enhance the condensation of volatile secondary WSOC on pre-existing aerosols. In summertime, atmospheric aerosols and WSOC concentrations showed bimodal size distributions, peaking at the size ranges $0.32{\sim}0.56\;{\mu}m$ (condensation mode) and $3.2{\sim}5.6\;{\mu}m$ (coarse mode), respectively. During the wintertime, atmospheric aerosols showed a bimodal character, while WSOC concentrations showed a unimodal pattern. Size distributions of atmospheric aerosols and WSOC with a peak in the size range $0.32{\sim}0.56\;{\mu}m$ were observed for most of the measurement periods. On January 17, however, atmospheric aerosols and WOSC exhibited size distributions with modal peaks in the size range $1.0{\sim}1.8\;{\mu}m$, suggesting that the aerosol particles collected on that day could be expected to be more aged, i.e, longer residence time, than the aerosols at other sampling periods.

Principles and Applications of Multi-Level H2O/CO2 Profile Measurement System (다중 수증기/이산화탄소 프로파일 관측 시스템의 원리와 활용)

  • Yoo, Jae-Ill;Lee, Dong-Ho;Hong, Jin-Kyu;Kim, Joon
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.11 no.1
    • /
    • pp.27-38
    • /
    • 2009
  • The multi-level profile system is designed to measure the vertical profile of $H_2O$ and $CO_2$ concentrations in the surface layer to estimate the storage effects within the plant canopy. It is suitable for long-term experiments and can be used also in advection studies for estimating the spatial variability and vertical gradients in concentration. It enables the user to calculate vertical fluxes of water vapor, $CO_2$ and other trace gases using the surface layer similarity theory and to infer their sources or sinks. The profile system described in this report includes the following components: sampling system, calibration and flow control system, closed path infrared gas analyzer(IRGA), vacuum pump and a datalogger. The sampling system draws air from 8 inlets into the IRGA in a sequence, so that for 80 seconds air from all levels is measured. The calibration system, controlled by the datalogger, compensates for any deviations in the calibration of the IRGA by using gas sources with known concentrations. The datalogger switches the corresponding valves, measures the linearized voltages from the IRGA, calculates the concentrations for each monitoring level, performs statistical analysis and stores the final data. All critical components are mounted in an environmental enclosure and can operate with little maintenance over long periods of time. This report, as a practical manual, is designed to provide helpful information for those who are interested in using profile system to measure evapotranspiration and net ecosystem exchanges in complex terrain.

Tracer Experiment for the Investigation of Urban Scale Dispersion of Air Pollutants - An Improved Method for the Release and Determination of Perfluorocarbon Tracers in the Urban Atmosphere (추적자 확산 실험에 의한 서울 도심 확산 현상 연구 - 도시규모 대기확산 실험을 위한 PFCs 추적자 방출 및 분석 시스템의 개발 및 적용 연구)

  • Yoo, Eun-Jin;Lee, Chong-Bum;Ro, Chul-Un;Kim, Hye-Kyeong;Lee, Gang-Woong
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.5
    • /
    • pp.547-556
    • /
    • 2007
  • The release, sampling and analytical methods have been developed and tested for perfluorocarbons (PFCs) atmospheric tracers in order to gain insight into the atmospheric transport and dispersion over the urban conditions of Seoul, Korea. Although PFCs tracer experiments provide unique opportunities to test local and urban scale of transport and dispersion, no previous experiment with PFCs has been conducted in Korea. PMCH and PDCH were chosen as targeted tracers in our study due to their extreme low ambient concentrations and great sensitivities among various PFCs. For PFCs release system, a set of micro-metering pump, electronic balance, vaporizing furnace and high speed blower was constructed for precise and accurate release of tracers. The precision of released rate by this system was estimated to be 1%. Samplings of PFCs were carried out by fabricated portable air samplers with micro pumps and rotameters into glass tubes packed with 150 mg of Carboxen-569. The uncertainty of these sampling system was maintained below 14%. PMCH and PDCH were quantified in GC/ECD with preconditioned injection system to eliminate the interference compounds using traps and subsequent catalytic conversion system prior to column separation. Three intensive field test were undertaken during the springtime of 2002 to 2004 in eastern part of Seoul. Daily background samples were collected to characterize the background levels of PMCH and PDCH prior to their release. The observed background concentrations of PMCH ranged from 3.5 to 10.1 fL/L and varied randomly in location and time in this study. Its mean and standard variation of background concentration ($6.8{\pm}1.9\;fL/L$) are higher than those ($3.2{\sim}5.8\;fL/L$) of other historic tracer studies. Identified uncertainty for background PMCH was $1.7{\sim}2.0\;fL/L$ using this analytical system. Combined relative uncertainty in determining the tracer's concentrations was estimated as 17%. However, its background concentrations and uncertainty in concentration determination were found to be low and stable enough for tracer study.

Diurnal and Nocturnal Behaviour of Airborne Cryptomeria japonica Pollen Grains and the Allergenic Species in Urban Atmosphere of Saitama, Japan

  • Wang, Qingyue;Nakamura, Shinichi;Lu, Senlin;Nakajima, Daisuke;Suzuki, Miho;Sekiguchi, Kazuhiko;Miwa, Makoto
    • Asian Journal of Atmospheric Environment
    • /
    • v.7 no.2
    • /
    • pp.65-71
    • /
    • 2013
  • Japanese cedar (Cryptomeria japonica) pollinosis is the most popular pollinosis in Japan. It has been reported that Cryptomeria japonica pollen allergenic species are suspended as fine particles in the urban atmosphere. These allergenic fine particles are responsible for inducing asthma by breaking into the lower respiratory tract. It has also been found that pollinosis symptoms on the sufferers appear mainly at night-time by the results from epidemiological studies. However, the exact reason for these phenomena is not yet clarified. In this study, the diurnal and nocturnal behaviours of Cryptomeria japonica pollen grains and their allergenic species in the urban area of Saitama city of Kanto Plain were investigated. Airborne pollen grains and allergenic Cry j 1 concentrations in total suspended particulate matter (TSP) were investigated at two sampling sites, a heavy traffic road (roadside site) and at the balcony of the $10^{th}$ floor of the Building of Research and Project of Saitama University (general urban site). The latter sampling site where located about 300 m away from the roadside site was used as a general urban site unaffected by automobile traffic. The airborne pollen counts were measured with a real-time pollen monitor. Cry j 1 particles were collected with two high volume air samplers, and these concentrations were measured by surface plasmon resonance method with a Biacore J system. The diurnal variation of the airborne pollen counts was similar to the trends of temperature and wind speed during the day-time; whereas its tendency with wind speed trend was not observed during the night-time. Airborne pollen counts were lower with northern wind than with southern wind because the pollen comes from the mountainous areas, and the mountains in the south are closer, about half the distance to the northern mountains. It is suggested that the peaks of airborne pollen counts during night-time in the sampling site occurred by transport of pollen grains released during day-time in the mountainous forest areas, located c.a. 100 km away from the sampling site. On the roadside site the allergenic Cry j 1 concentrations were higher than at the general urban site, nevertheless pollen grains counts were lower. These results suggested that worsening of pollinosis symptoms during night-time in urban area was caused by transport of pollen grains during day-time in the mountainous forest areas. Moreover, pollen allergenic species become different morphology from pollen grain at roadside site, and the subsequent pollen grains re-suspension by automobile traffic.

Critical Evaluation of and Suggestions for the VOCs Measurement Method Established as the Korean Indoor Air Quality Standard Method (실내공기질 공정시험법 중 VOCs 측정방법의 문제점 고찰 및 개선방안에 관한 연구)

  • Ye, Jin;Jung, Dong-Hee;Baek, Sung-Ok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.6
    • /
    • pp.586-599
    • /
    • 2014
  • During the last two decades, indoor air quality and volatile organic compounds (VOCs) have been of concern in Korean society due to their nature of potential health impacts. In order to investigate the pollution levels of VOCss in indoor environments, establishment of a solid test method for monitoring the airborne VOCss is essential. In Korea, a method based on adsorbent sampling and GC analysis coupled with thermal desorption was proclaimed as the Korea Standard Method for Indoor Air Quality Test. This study was carried out to examine some inherent problems of the VOCs measurement method. The VOCs method does not describe in detail preparing the standard samples. The standard samples may be prepared by impregnation of either liquid standard solutions or a mixture of standard gases. In this study, we investigated the optimal temperature condition for transferring the liquid standards onto a standard adsorbent tube. As a result, keeping the impregnation temperature at $250^{\circ}C$ will be recommended in regard of the boiling points of multiple target analytes and the thermal stability of the adsorbent. We also demonstrated some problems associated with handling of a syringe used for transferring the standard solutions onto the adsorbent tubes, and a best way to get rid of the syringe problems was suggested. Finally, a number of field works were conducted to evaluate the performance of adsorbent sampling methods. Comparison of different adsorbent tubes, i.e. tube packed with single sorbent (Tenax) and double sorbents (Tenax with Carbotrap), revealed that 30 to 40% differences between the two groups, implying that sampling efficiency is depending on the volatility and the strength of adsorbents. However, duplicate precisions for VOCs sampling with a same type of adsorbent and at same flow rates appeared to be satisfactory to be all within 20%, which is a quality control guideline. Distributed volume precisions were also found to be within a guideline value, 25%, although the precision was in general inferior to the duplicate precision. The Korea indoor VOCs test method should be more refined and improved in many aspects, particularly procedure and instrumentation for preparing the standard samples and specification of quality control assessment.

Distribution of Airborne Hexavalent Chromium Concentrations in Large Industrial Complexes in Korea

  • Kang, Byung-Wook;Lee, Hak-Sung;Kim, Jong-Ho;Hong, Ji-Hyung;Kim, Rok-Ho;Seo, Young-Kyo;Han, Jin-Seok;Baek, Kyung-Min;Kim, Min-Ji;Baek, Sung-Ok
    • Asian Journal of Atmospheric Environment
    • /
    • v.10 no.4
    • /
    • pp.208-216
    • /
    • 2016
  • This paper reports the results of a field evaluation which used sampling and analytical methods to determine the levels of airborne hexavalent chromium Cr(VI) in major industrial complexes in Korea over a seven year period (2007-2013). Cr(VI) concentrations were determined using cellulose filter sampling and ion chromatography analysis. In order to validate the analytical performance of these methods, studies were also carried out to investigate data quality control (QC) parameters, such as the method detection limit (MDL), repeatability, and recovery efficiencies. The average concentrations of Cr(VI) for the nine industrial complexes in Korea were in the range of 0.09 to $1.40ng/m^3$, which is similar to of the concentrations in other industrial areas around the world. The impacts of Cr(VI) emissions from industrial areas on Cr(VI) concentrations in neighboring-residential areas were considerably low, and the dispersion of Cr(VI) from industrial areas to residential areas was estimated to be 'not-significant'. Cr(VI) levels were not affected by seasonal variation, which suggests that chromium was emitted continuously from the industrial sources throughout the year. The concentration of Cr(VI) measured accounted for 0.7 to 9.4 percent of the total chromium level, which is a low percentage compared to those in other urban areas around the world. This is the first report in an international journal of a field study conducted in Korea to determine the concentration of Cr(VI) in the ambient air of industrial and residential areas.

Occurrence of Phthalates in Indoor Dust from Children's Facilities and Apartments in Seoul

  • Kim, Ho-Hyun;Lim, Young-Wook;Yang, Ji-Yeon;Shin, Dong-Chun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.25 no.5
    • /
    • pp.382-391
    • /
    • 2009
  • The aim of the study was to assess the levels in typical central borough of phthalate exposure by monitoring children's facilities (19 kindergartens and 21 elementary schools) and households (17 old apartments and 22 new apartments) via sampling indoor floor dust. A vacuum cleaner specifically prepared for sampling dust was attached to a filter of a vacuum cleaner dust collecting container. During the sample preparation process, containers made of glass were used and analysis was performed using GC-MSD. The mean concentration of DEHP was $412{\mu}g/g$, DnBP was $24{\mu}g/g$, and BBzP was $10{\mu}g/g$ dust. The indoor characteristics including floor, wall materials, years after construction, water leakage history for the past three years, and ventilation were also examined to categorize phthalate esters from the dust samples. From the flooring and wallpaper materials of kindergartens and elementary schools, DEHP in the dust sample appeared at a statistically significant level (p<0.05) when PVC materials were present. DEHP in the indoor dust also increased significantly (p<0.01) during the construction period. The daily intake of DEHP measured from indoor dust was 0.08~$19.7{\mu}g/kg/day$ for children and 0.02~$1.1{\mu}g/kg/day$ for adults (women). The results clearly revealed that phthalate exposure is greater in children than in adults (women) due to the indoor dust.

Temporal Variations in Optical Properties and Direct Radiative Forcing of Different Aerosol Chemical Components in Seoul using Hourly Aerosol Sampling (서울지역 시간별 에어로솔 자료를 이용한 화학성분별 광학특성 및 직접 복사강제력의 시간 변화 분석)

  • Song, Sang-Keun;Shon, Zang-Ho
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.1
    • /
    • pp.1-17
    • /
    • 2014
  • Temporal variations of optical properties of urban aerosol in Seoul were estimated by the Optical Properties of Aerosols and Clouds (OPAC) model, based on hourly aerosol sampling data in Seoul during the year of 2010. These optical properties were then used to calculate direct radiative forcing during the study period. The optical properties and direct radiative forcing of aerosol were calculated separately for four chemical components such as water-soluble, insoluble, black carbon (BC), and sea-salt aerosols. Overall, the coefficients of absorption, scattering, and extinction, as well as aerosol optical depth (AOD) for water-soluble component predominated over three other aerosol components, except for the absorption coefficient of BC. In the urban environment (Seoul), the contribution of AOD (0.10~0.12) for the sum of OC and BC to total AODs ranged from 23% (spring) to 31% (winter). The diurnal variation of AOD for each component was high in the morning and low in the late afternoon during the most of seasons, but the high AODs at 14:00 and 15:00 LST in summer and fall, respectively. The direct negative radiative forcing of most chemical components (especially, $NO_3{^-}$ of water-soluble) was highest in January and lowest in September. Conversely, the positive radiative forcing of BC was highest in November and lowest in August due to the distribution pattern of BC concentration.