• Title/Summary/Keyword: Atmospheric Stability

Search Result 267, Processing Time 0.027 seconds

The Effects of Injector and Swirler on the Flame Stability in a Model Combustor (모델연소기에서의 화염 안정화에 대한 분사기와 선회기의 영향)

  • Park, Seung-Hun;Lee, Dong-Hun;Bae, Choong-Sik
    • Journal of the Korean Society of Combustion
    • /
    • v.3 no.2
    • /
    • pp.13-27
    • /
    • 1998
  • The optimization of frontal device including fuel nozzle and swirler is required to secure the mixing of fuel and air and the combustion stability leading the reduction of pollutant emissions and the increase of combustion efficiency in gas turbine combustor. The effects of injection nozzle and swirler on the flow field, spray characteristics and consequently the combustion stability, were experimentally investigated by measuring the velocity field, droplet sizes of fuel spray, lean combustion limit and the temperature field in the main combustion region. Flow fields and spray characteristics were measured with APV(Adaptive Phase Doppler Velocimetry) under atmospheric condition using kerosine fuel. Temperatures were measured by Pt-Pt13%Rh, R-type thermocouple which was 0.2mm thick. Spray and flame was visualized by ICCD(Intensified Charge Coupled Device) camera. It was found that the dual swirler resulted in the biggest recirculation zone with the highest reverse flow velocity at the central region, which lead the most stable combustion. The various combustion characteristics were observed as a function of the geometries of injector and swirler, that gave a tip for the better design of gas turbine combustor.

  • PDF

An Experimental Analysis of the Structural Stability Analysis of a Container Crane according to the change of the Boom Shape (붐 형상 변화에 따른 컨테이너 크레인 구조 안정성의 실험적 해석)

  • Lee S.W.;Han D.S.;Shim J.J.;Han G.J.;Kim T.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.371-372
    • /
    • 2006
  • This study was carried out to analyze the effect of wind load on the structural stability of a container crane according to the change of the boom shape using wind tunnel test and provide a container crane designer with data which can be used in a wind resistance design of a container crane assuming that a wind load 75m/s wind velocity is applied in a container crane. Data acquisition conditions for this experiment were established in accordance with the similarity. The scale of a container crane dimension, wind velocity and time were chosen as 1/200, 1/13.3 and 1/15. And this experiment was implemented in an Eiffel type atmospheric boundary layer wind tunnel with $11.52m^2$ cross-section area. Each directional drag and overturning moment coefficients of a container crane according to the change of the boom shape were investigated.

  • PDF

The Effects of Injector and Swirler on the Flame Stability in a Model Combustor (모델연소기에서의 분사기와 선회기의 영향)

  • Park, Seung-Hun;Lee, Dong-Hun;Bae, Chung-Sik
    • 한국연소학회:학술대회논문집
    • /
    • 1998.10a
    • /
    • pp.9-21
    • /
    • 1998
  • The optimization of frontal device including fuel nozzle and swirler is required to secure the mixing of fuel and air, and the combustion stability in the gas turbine combustor design for the reduction of pollutant emissions and the increase of combustion efficiency. The effects of injection nozzle and swirler on the flow field, spray characteristics and consequently the combustion stability, were experimentally investigated by measuring the velocity field, droplet sizes of fuel spray, lean combustion limit and the temperature field in the main combustion region. The effect of fuel injection nozzle was tested by adopting three different nozzles; a dual orifice fuel nozzle, a hollow cone nozzle and a solid cone nozzle. These tests were combined with the three different swirler geometries; a dual-stage swirler with 40$^{\circ}$ /-4 5$^{\circ}$ vanes and two single-stage swirlers with 40$^{\circ}$ vane angle having 12 and 16vanes, respectively. Flow fields and spray characteristics were measured with APV(Adaptive Phase Doppler Velocimetry) under atmospheric condition using kerosine fuel. Temperatures were measured by Pt-PtI3%Rh, R-type thermocouple which was 0.2mm thick. It was found that the dual swirler resulted in the biggest recirculation zone with the highest reverse flow velocity at the central region, which lead the most stable combustion. The various combustion characteristics were observed as a function of the combination between the injector and swirler, that gave a tip for the better design of gas turbine combustor.

  • PDF

EVALUATION OF DATA QUALITY OF PERMANENT GPS STATIONS IN SOUTH KOREA

  • Park, Kwan-Dong;Kim, Ki-Nam;Lim, Hyung-Chul;Park, Pil-Ho
    • Journal of Astronomy and Space Sciences
    • /
    • v.19 no.4
    • /
    • pp.367-376
    • /
    • 2002
  • As of September 2002, there are more than 60 operational permanent Global Positioning System (GPS) stations in South Korea. Their data are being used for a variety of purposes: geodynamics, geodesy, real-time navigation, atmospheric science, and geography. Especially, many of the sites are reference stations for DGPS (Differential GPS). However, there has been no comprehensive and qualitative analysis published to evaluate the data quality. In this study, we present preliminary results of our assessment of the permanent GPS sites in South Korea. We have analyzed the multi-path characteristics of each station using a quality-checking software package called TEQC. Another multipath analysis tool based on post-fit phase residuals was used to check the repeating patterns and the amount of the multipath at each site. The long-term stability of each station was analyzed using the root-mean-square (RMS) error of the estimated site positions for one year, which enabled us to evaluate the mount stability. In addition, the number of cycle slips at each site was derived by TEQC. Based on these series of tests, we compared the stability and data quality of permanent GPS stations in South Korea.

The Structural Stability Analysis of an Articulation Type Container Crane Using Wind Tunnel Test (풍동실험을 이용한 관절형 컨테이너 크레인의 구조 안정성 해석)

  • Lee S.W.;Shim J.J.;Han G.J.;Kim T.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.838-841
    • /
    • 2005
  • This study was carried out to analyze the effect of wind load on the structural stability of a 50ton articulation type container crane using wind tunnel test and provide a container crane designer with data which can be used in a wind resistance design of an articulation type container crane assuming that a wind load 75m/s wind velocity is applied in an articulation type container crane. Data acquisition conditions for this experiment were established in accordance with the similarity. The scale of an articulation type container crane dimension, wind velocity and time were chosen as 1/200, 1/13.3 and 1/15. And this experiment was implemented in an Eiffel type atmospheric boundary layer wind tunnel with $11.52m^2$ cross-section area. Each directional drag and overturning moment coefficients were investigated and uplift forces at each supporting point due to the wind load were analyzed.

  • PDF

Development of Primary Standard Gas Mixtures of Fourteen Volatile Organic Compounds in Hazardous Air Pollutants for Accurate Ambient Measurements in Korea (at 1 μmol/mol Levels) (유해대기오염물질 중 14종의 휘발성유기화합물 1차 표준가스개발 (1 μmol/mol 수준))

  • Kang, Ji Hwan;Kim, Young Doo;Kim, Mi Eon;Lee, Jinhong;Lee, Sangil
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.2
    • /
    • pp.331-341
    • /
    • 2018
  • Hazardous air pollutants(HAPs) in the atmosphere are regulated as major air pollutants in Korea by the Air Pollution Control Act. In order to manage and control HAPs, accurate standards, which are traceable to the International System of Units(SI), are required. In this study, primary standard gas mixtures(PSMs) of volatile organic compounds(VOCs) which are specified as HAPs were developed at $1{\mu}mol/mol$ levels. The selected fourteen VOCs include Benzene, Toluene, Ethylbenzene, m-Xylene, Styrene, o-Xylene, Chloroform, 1,1,2-Trichloroethane, Trichloroethylene, Tetrachloroethylene, 1,1-Dichloroethane, Carbon tetrachloride, 1,3-Butadiene, and Dichloromethane. The HAPs PSMs were gravimetrically prepared in aluminum cylinders and their consistency was verified within the relative expanded uncertainty of 0.71% (k=2). Potential adsorption loss onto the internal surface of cylinders was estimated by cylinder-to-cylinder division method. No adsorption loss was observed within the uncerainty of 0.53%. The long-term stability of the HAPs PSMs was evaluated comparing with freshly prepared HAPs PSMs. The HAPs PSMs were stable for one year within the uncertainty of 0.38%. The final uncertainty of the PSMs was determined by combining the preparation uncertainty, verification uncertainty, and stability uncertainty. Finally, traceable and stable HAPs PSMs at $1{\mu}mol/mol$ levels were developed with the uncertainty of less than 0.76% in high-pressure aluminum cylinders.

Assessment of Ozone Risk for Wheat in the Central Region of the Korean Peninsula (한반도 중부지역의 밀에 대한 오존 위해도 평가)

  • Hong, Nak-Gi;Lee, ChongBum;Kim, Jea-Chul;Cheon, Tae Hun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.31 no.1
    • /
    • pp.41-53
    • /
    • 2015
  • This study was performed to assess the level of ozone risk for wheat in the central region of the Korean Peninsula by using two ozone indices, the ozone-concentration based index (AOT40) and the ozone-flux based index ($AF_{st}Y$), and to analyze the relationship between the two indices. In the present study for $AF_{st}Y$ calculation, the Monin-Obukhov length was estimated using the Pasquill stability class which was determined from routine meteorological data such as wind speed, solar radiation and cloudiness. The AOT40 and $AF_{st}6$ indices were calculated for wheat at 3 sites in the central region of the Korean Peninsula during a period of 3 months from April 1 to June 30, 2006. It should be noted that the estimation of ozone index $AF_{st}6$ in this study was performed under several assumptions. The results for both indices, AOT40 and $AF_{st}6$, showed that agricultural crops could be seriously damaged by ozone in the local region of the Korean Peninsula.

Hadley Circulation Strength Change in Response to Global Warming: Statistics of Good Models

  • Son, Jun-Hyeok;Seo, Kyong-Hwan
    • Atmosphere
    • /
    • v.26 no.4
    • /
    • pp.665-672
    • /
    • 2016
  • In this study, we examine future changes in the Hadley cell (HC) strength using CMIP5 climate change simulations. The current study is an extension of a previous study by Seo et al. that used all 30 available models. Here, we select 18-23 well-performing models based on their significant internal sensitivity of the interannual HC strength variation to the latitudinal temperature gradient variation. The model projections along with simple scaling analysis show that the inter-model variability in the HC strength change is a result of the inter-model spread in the meridional temperature gradient across the subtropics for both DJF and JJA, not by the tropopause height or gross static stability change. The HC strength is expected to weaken significantly during DJF, while little change is expected in the JJA HC strength. Compared to the calculations with all model members, selected model statistics increase the linear correlation between the changes in HC strength and meridional temperature gradient by 13~23%, confirming the robust sensitivity of the HC strength to the meridional temperature gradient. Two scaling equations for the selected models predict changes in HC strength better than all-member predictions. In particular, the prediction improvement in DJF is as high as 30%. The simple scaling relations successfully predict both the ensemble-mean changes and model-to-model variations in the HC strength for both seasons.

Performance Analysis for Various Flight Conditions with Air Disturbance (대기외란을 적용한 램제트 엔진의 비행 조건별 성능 연구)

  • Seo, Bong-Gyun;Choi, Jae-Hyung;Sung, Hong-Gye;Park, Jung-Woo;Park, Ik-Soo;Yoon, Hyun-Gull
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.588-593
    • /
    • 2011
  • In this study, the performance analysis method for ramjet engine system with atmospheric air disturbance was proposed. Flight path was determined to satisfy dynamic pressure constant at each flight altitude. The atmospheric air disturbance incoming into a engine intake was simulated by the model Tank proposed. The performance parameters was investigated at each flight condition with air disturbance. Engine operation stability was evaluated as analysis of the normal shock position.

  • PDF

A CFD Study of Near-field Odor Dispersion around a Cubic Building from Rooftop Emissions

  • Jeong, Sang Jin
    • Asian Journal of Atmospheric Environment
    • /
    • v.11 no.3
    • /
    • pp.153-164
    • /
    • 2017
  • Odor dispersion around a cubic building from rooftop odor emissions was investigated using computational fluid dynamics (CFD). The Shear Stress Transport (here after SST) $k-{\omega}$ model in FLUENT CFD code was used to simulate the flow and odor dispersion around a cubic building. The CFD simulations were performed for three different configurations of cubic buildings comprised of one building, two buildings or three buildings. Five test emission rates were assumed as 1000 OU/s, 2000 OU/s, 3000 OU/s, 4000 OU/s and 5000 OU/s, respectively. Experimental data from wind tunnels obtained by previous studies are used to validate the numerical result of an isolated cubic building. The simulated flow and concentration results of neutral stability condition were compared with the wind tunnel experiments. The profile of streamline velocity and concentration simulation results show a reasonable level of agreement with wind tunnel data. In case of a two-building configuration, the result of emission rate 1000 OU/s illustrates the same plume behavior as a one-building configuration. However, the plume tends to the cover rooftop surface and windward facet of a downstream building as the emission rate increases. In case of a three-building configuration, low emission rates (<4000 OU/s) form a similar plume zone to that of a two-building configuration. However, the addition of a third building, with an emission rate of 5000 OU/s, creates a much greater odorous plume zone on the surface of second building in comparison with a two-building configuration.