• Title/Summary/Keyword: AtPIN3

Search Result 464, Processing Time 0.025 seconds

ACL reconstruction with autologous hamstring tendon - Short term clinical result using new femoral suspensory fixation device 'Cross Pin' and graft tensioner for maintaining a constant tension- (자가 슬괵건을 이용한 전방 십자 인대 재건술 - 새로운 대퇴부 현수고정법인 Cross Pin과 일정한 긴장력 유지를 위한 Graft Tensioner 사용의 단기 추시 결과 -)

  • Seo, Seung-Suk;Kim, Chang-Wan;Kim, Jin-Seok;Choi, Sang-Yeong
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.10 no.1
    • /
    • pp.27-34
    • /
    • 2011
  • Purpose: To evaluate the short term clinical result of ACL reconstruction with autologous hamstring tendon using Cross pin and Graft Tensioner and to seek way to resolve the experienced technical problems. Materials and Methods: From January 2008 to March 2009, 35 patients who had been treated arthroscopic ACL reconstruction were enrolled. The femoral side of ACL graft was fixed with Cross pin. The tibial side of graft was fixed with Intrafix and post-tie. The graft was tensioned with Graft Tensioner at 80N. We analyzed the clinical, radiographic results and complications. Results: IKDC subjective score and Lysholm score improved to 89.1 and 91.4 points. Also, Pivot shift test and One-leg hop test showed good results postoperatively. Side to side difference using KT-1000 arthrometer and Telos stress radiography improved compared with normal limb to $2.8{\pm}1.6$ mm and $2.6{\pm}1.3$ mm, respectively. The femoral tunnel enlarged to $2.3{\pm}1.1$ mm. Soft tissue irritation and femoral tunnel-graft harness length mismatch, femoral tunnel-cross pin tunnel mismatch were happened as peri-operative complications. Conclusion: Using of Cross pin and Graft Tensioner for ACL reconstruction with hamstring tendon is one of the good method for obtaining stability in short-term clinical result. But to reduce femoral tunnel-cross pin mismatch, it needs to shorten femoral bone tunnel and to create cross pin tunnel as vertical as possible. And to reduce femoral tunnel-graft harness mismatch, it needs to advance position rod further 3 mm when to create femoral tunnel.

  • PDF

Effects of Preoxidation on High Temperature Wear of Piercing Plug Tool Steel Sliding Against SA210C Steel Used for Production of Seamless Tube (심리스 튜브 제조용 피어싱 플러그 공구강과 SA210C강의 고온 미끄럼 마모에 미치는 예비산화의 영향)

  • Choi, Byung-Young;Gu, Yoon-Sik
    • Journal of the Korean institute of surface engineering
    • /
    • v.46 no.6
    • /
    • pp.264-270
    • /
    • 2013
  • Effects of preoxidation on high temperature wear of piercing plug tool steel sliding against SA210C steel used for production of seamless tube have been studied using a pin-on-disc CETR tribometer, under applied normal load of 20 N at $900^{\circ}C$ in air. It was found in the preoxidized pin specimens of piercing plug tool steel that the coefficient of friction decreased to about 0.4 at an initial stage followed by showing nearly constant value of about 0.4 during high temperature wear testing. On the other hand, it was also found in the pin specimens without preoxidation that the coefficient of friction increased and fluctuated, ranging from about 0.3 to 0.6 during the tests until the running period of about 800 sec. The compact and continuous Fe-oxide layer was formed on the contact surface of the preoxidized pin specimens after high temperature wear testing followed by penetrating along the grain boundaries of coarse ferrite in the decarburized region beneath the oxide layer due to the lower hardness of the region.

Numerical Study on the Effect of Guide Vane Position and Angle on Heat Transfer and Flow Characteristics of a Pin-fin Channel with a Guide Vane (가이드 베인을 부착한 핀-휜 유동에서 가이드 베인 위치와 입사각에 따른 전열 및 유동 특성에 관한 수치적 연구)

  • Lee, Deukho;Oh, Yeongtaek;Bae, Jihwan;Lee, Changhyeong;Kim, Kuisoon
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.23 no.3
    • /
    • pp.35-43
    • /
    • 2019
  • In this study, a guide vane with varying positions and incidence angles was adopted to a pin-fin channel to analyze the change in thermal performance and pressure loss characteristics. A numerical analysis was conducted to investigate the effect of incidence angles and positions on heat transfer and flow characteristics at Re =1400. The results of it were compared those of a pin-fin channel without a guide vane. In case 1 when the incidence angle is $0^{\circ}$, the heat transfer performance is maximized and improved by approximately 5% when compared to the pin-fin channel without the guide vane. In case 2 when the incidence angle is $10^{\circ}$, the pressure loss is minimized and decreased by approximately 1.9% when compared to the pin-fin channel without the guide vane.

Design of Small-Size High-Power SPDT PIN Diode Switch with Defected Ground Structure for Wireless Broadband Internet Application (결함접지구조(Defected Ground Structure)를 갖는 휴대 인터넷용 소형 고전력 SPDT PIN 다이오드 스위치 설계)

  • Kim Dong-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.10 s.101
    • /
    • pp.1003-1009
    • /
    • 2005
  • In this paper, small-size high-power single pole double throw(SPDT) switch with defected pound structure(DGS) is presented for wireless broadband internet application. To reduce the circuit size using slow-wave characteristic, the DGS is applied to ${\lambda}/4$ transmission line of the switch and the measured results are compared with them of conventional switch. To secure high degree of isolation, the switch with the DGS is composed of shunt-connected PIN diodes and shows insertion loss of 0.8 dB and isolation more than 50 dB at 2.3 GHz. The size of the switch is reduced about $50\%$ only with the DGS patterns while it has very similar performance to the conventional shunt-type switch.

Effect of Temperature on the Performance Characteristics of a Pin-Cylinder Discharge Type Ozonizer

  • Md. Fayzur Rahman;Chun, Byung-Joon;Lee, Kwang-Sik;Lee, Dong-In
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.12C no.4
    • /
    • pp.201-207
    • /
    • 2002
  • A Pin-Cylinder discharge type ozonizer was designed and manufactured. The increase or decrease of temperature greatly influences on the characteristics of ozone generation of a discharge type ozonizer. The characteristics of ozone concentration ( $O_{3con}$), ozone generation ($_{3g}$) and ozone yield .ate ($_{3Y}$) of the ozonizer were investigated by varying the gas flow rate (Q), the discharge power ($_{Wd}$ ) and the temperature (T). At T = 20($^{\circ}C$), the values of ( $O_{3con}$) were found as 7800,5300,3000 and 2300(ppm) at Q=1,2,4 and 6(1/min) respectively. The corresponding values of ( $O_{3g}$) were found as 917, l247,1411 and 1623(mg/h) and those of ( $O_{3Y}$) were 93,126,143 and 164(g/kWh) respectively. When the temperature is decreased to -50($^{\circ}C$), the values of ( $O_{3con}$) became 12000,8000,5200 and 3600(ppm) at Q=1,2,4 and 6(1/min) respectively. The corresponding values of 0,9 were obtained as 1411,1882,2446 and 2600(mg/h) and those of ($O_{3Y}$) were 143,190,247 and 2631g/kWh] respectively. Hence as the temperature was decreased from 20 to -50[。C], the efficiencies of ozone generation were increased by 54,51,73 and 60[%] at Q=1,2,4 and 6(1/min) respectively.ctively.

Usefulness of Treatment with 6.5 mm Cancellous Screw and Steinmann Pin Fixation for Calcaneal Joint Depression Fracture (종골의 관절 함몰 골절에서 6.5 mm 해면골 나사와 Steinmann 핀을 이용한 치료의 유용성)

  • Lee, Gi-Soo;Kang, Chan;Hwang, Deuk-Soo;Noh, Chang-Kyun;Lee, Gi-Young
    • Journal of Korean Foot and Ankle Society
    • /
    • v.19 no.1
    • /
    • pp.11-17
    • /
    • 2015
  • Purpose: To report the radiographic and clinical results of 6.5 mm cancellous full threaded buttress screw or Steinmann pin fixation to maintain a reduction of calcaneal posterior facet depression fracture. Materials and Methods: From June 2009 to June 2012, 50 consecutive cases with calcaneal joint depression fracture that underwent open reduction and screw or pin fixation were enrolled in this study. A 6.5 mm cancellous full threaded screw was inserted from the posteroinferior aspect of the calcaneal tuberosity to the posterior facet (group A) or Steinman pin was inserted from the posterosuperior aspect of the calcaneal tuberosity to the calcaneocuboidal joint (group B). Both preoperative and postoperative Bohler and Gissane angles were measured radiographically, and American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot scale on the final follow-up were assessed. Results: The mean age of patients was 44.1 years, and the mean follow-up period was 27.2 months. According to the Sanders classification, 28 cases were type II and 22 cases were type III. In Sanders type II, Bohler and Gissane angles improved significantly from $10.1^{\circ}$ and $126.2^{\circ}$ preoperatively to $27.2^{\circ}$ and $117.1^{\circ}$, respectively, in the immediate postoperative radiograph, and at the final follow-up, $26.6^{\circ}$ and $118.6^{\circ}$, respectively. In Sanders type III, Bohler and Gissane angles improved significantly from $5.0^{\circ}$ and $129.8^{\circ}$ to $29.9^{\circ}$ and $119.3^{\circ}$, respectively, in the immediate postoperative radiograph, and $26.9^{\circ}$ and $120.2^{\circ}$ at the final follow-up. All cases achieved bony union, and the average period until complete union was 13.3 weeks. AOFAS ankle-hindfoot scale was 82.6 in Sanders type II and 77.3 in Sanders type III at the final follow-up. Conclusion: A 6.5 mm cancellous full threaded buttress screw or Steinman pin fixation is a noninvasive treatment method with a merit of being able to maintain the bearing capacity of the posterior facet comparable to plate fixation.

Efficacy of Temporal Fixation Using Threaded Trans-Calcaneal Pin in Patients with Ankle Fracture-Dislocation or Tibia Pilon Fractures (발목 골절 및 탈구 혹은 경골 천정 골절 환자들의 수술에 있어 경종골핀을 이용한 발목 외고정 장치를 적용했을 때의 임상적 효용성)

  • Park, Dae-Hyun;Gwak, Heui-Chul;Kim, Jung-Han;Lee, Chang-Rak;Kwon, Yong-Uk;Choo, Hye-Jung;Park, Chul-Soon
    • Journal of Korean Foot and Ankle Society
    • /
    • v.24 no.2
    • /
    • pp.81-86
    • /
    • 2020
  • Purpose: Ankle fractures with dislocations and pilon fractures at the distal tibia are usually associated with soft tissue damage caused by high-energy damage. Recently, a two-stage operation to perform internal fixation after the application of external fixation devices for stabilizing soft tissues has been accepted as the treatment of choice. This paper reports the clinical result of these injuries treated with threaded trans-calcaneal pin external fixation devices. Materials and Methods: Thirty-three patients diagnosed with ankle fractures with dislocations or tibial pilon fractures without open wounds. They underwent surgical treatment with threaded trans-calcaneal pin external fixation from January 2008 to February were enrolled in this study. This study evaluated the visual analogue scale (VAS), foot function index (FFI), and Olerud & Molander score as well as whether complications occurred. Results: The average VAS showed a meaningful decrease (p<0.001) from 7.4 before surgery to 2.6 after application of the external fixation device, and 1.4 at 12 months after surgery. The FFI also decreased significantly from 84.3 preoperatively to 20.3 at 12 months postoperatively (p<0.001). The Olerud & Molander score averaged 71.4 points, showing good clinical results. Complete bone union was observed in all patients. One patient each underwent debridement due to wound necrosis and infection in the pin insertion site. At the final follow-up, seven patients had posttraumatic ankle joint arthritis, according to a radiological examination. Conclusion: Manual reduction and external fixation using a threaded trans-calcaneal pin is a suitable surgical technique that is easy to perform and shows good clinical outcomes in stabilizing soft tissue damage in fractures and dislocations of ankle fracture or tibia pilon fractures in foot and ankle injury.

A Polarization-Switchable Microstrip Patch Antenna Using Corner Slots on Ground Plane and PIN Diodes (모서리 접지면 슬롯과 PIN 다이오드를 이용한 편파 변환 마이크로스트립 안테나)

  • Park, Chul-Woo;Lee, Tae-Hak;Choi, Jun-Ho;Yoon, Won-Sang;Pyo, Seong-Min;Kim, Young-Sik
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.7
    • /
    • pp.769-777
    • /
    • 2010
  • In this paper, a switchable circularly polarized microstrip patch antenna using PIN diodes and corner slots on ground plane is proposed at 2.4 GHz. The proposed antenna has a square microstrip patch and ground plane that consists of two pair of slots and PIN diodes. The electrical lengths of the slots are adjusted by using the switching characteristic of the PIN diode, so the polarization of the proposed antenna can be switchable between linear, left-handed(LH) and right-handed(RH). By separating the ground plane for the DC bias, the size reduction effect is also obtained. When the proposed antenna is operated as linear polarization, the return loss and impedance bandwidth are 15 dB, 59 MHz, and when operated as LH and RH polarization, the minimum axial ratio and 3-dB axial ratio bandwidth are 1.17 dB, 1.67 dB, 28 MHz, and 32 MHz, respectively.

New Packaging and Characteristics of PIN PD for CWDM Transmission (저밀도 파장분할 다중화용 PIN PD 제작 및 특성)

  • Kang, Jae-Kwang;Chang, Jin-Heyon
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.12 no.4 s.37
    • /
    • pp.323-330
    • /
    • 2005
  • We fabricate PIN PD (Positive Intrinsic Negative Photo-Diode) for CWDM optical repeater and optical transmission system, and analyze theoretically the characteristics to verify the capability of device fabricated. Furthermore, we integrate CWDM filter into PD package to enhance the cost and the performance when compared to the conventional system, in which CWDM filter and PD package are linked by optical fusion splicing. The integrated CWDM PD is fabricated by three steps as follows: CWDM filter design, PD packaging, and product assembly and test. The results of measurement for PD fabricated reveal 0.5 dB bandwidth of 17 nm, isolation over 60 dB at transmission port and over 20 dB at reflection port. Also, the IMD3 for wireless communication is over 63 dBc, and the responsivity of PD presents over 0.9 A/W for 20 samples of the total 23 PD. The total insertion loss reduces about 0.4${\~}$0.7 dB due to the integrated assembly of CWDM and PD.

  • PDF

Organ Specific Expression of the nos-NPT II Gene in Transgenic Hybrid Poplar (형질 전환된 포플러에 대한 nos-NPT II 유전자의 기관별 발현 특성)

  • Chun, Young Woo;Klopfenstein, Ned B.
    • Journal of Korean Society of Forest Science
    • /
    • v.84 no.1
    • /
    • pp.77-86
    • /
    • 1995
  • To effectively modify tree function with genetic engineering, transgenes must be expressed at the proper level in the appropriate tissues at suitable developmental stages. Toward understanding the spatial and temporal expression of transgenes in woody plants, transgene expression was evaluated in three greenhouse-grown, transgenic lines of Populus alba ${\times}$ P. grandidentata hybrid clone 'Hansen'. All transgenic poplar lines possess constructs containing the bacterial nopaline synthase(nos) promoter linked to a neomycin phosphotransferase II(NPT II) selectable marker gene. In addition, each transgenic poplar line contains one of the following gene constructs : 1) a wound-inducible potato proteinase inhibitor II (pin2) promoter linked to a chloramphenicol acetyltransferase(CAT) reporter gene. 2) a nos promoter linked to a PIN2 structural gene : or 3) a Cauliflower Mosaic Virus 35s promoter linked to a PIN2 structural gene. Polymerase chain reaction(PCR) was used to verify the presence of foreign genes in the poplar genome. Enzyme-linked immunosorbent assays(ELISAs) were used to evaluate organ specific expression of the nos-NPT II construct. NPT II expression was detected in leaves, petioles, stems, and roots of transgenic poplar, thereby indicating that the nos promoter is potentially effective for general constitutive expression of transgenes. NPT expression varied among transgenic poplar lines and among organs for one transgenic line, Tr15. With Tr15, NPT II levels were highest in older leaves and petioles. These results indicate that screening of several transgenic lines may be required to identify lines with optimal transgene expression.

  • PDF