• Title/Summary/Keyword: AtPIN3

Search Result 464, Processing Time 0.022 seconds

An experimental study of the behaviour of double sided welded plate connections in precast concrete frames

  • Gorgun, Halil
    • Steel and Composite Structures
    • /
    • v.29 no.1
    • /
    • pp.1-22
    • /
    • 2018
  • Multi-storey precast concrete skeletal structures are assembled from individual prefabricated components which are erected on-site using various types of connections. In the current design of these structures, beam-to-column connections are assumed to be pin jointed. Welded plate beam to-column connections have been used in the precast concrete industry for many years. They have many advantages over other jointing methods in component production, quality control, transportation and assembly. However, there is at present limited information concerning their detailed structural behaviour under bending and shear loadings. The experimental work has involved the determination of moment-rotation relationships for semi-rigid precast concrete connections in full scale connection tests. The study reported in this paper was undertaken to clarify the behaviour of such connections under symmetrical vertical loadings. A series of full-scale tests was performed on sample column for which the column geometry and weld arrangements conformed with successful commercial practice. Proprietary hollow core slabs were tied to the beams by tensile reinforcing bars, which also provide the in-plane continuity across the connections. The strength of the connections in the double sided tests was at least 0.84 times the predicted moment of resistance of the composite beam and slab. The secant stiffness of the connections ranged from 0.7 to 3.9 times the flexural stiffness of the attached beam. When the connections were tested without the floor slabs and tie steel, the reduced strength and stiffness were approximately a third and half respectively. This remarkable contribution of the floor strength and stiffness to the flexural capacity of the joint is currently neglected in the design process for precast concrete frames. In general, the double sided connections were found to be more suited to a semi-rigid design approach than the single sided ones. The behaviour of double sided welded plate connection test results are presented in this paper. The behaviour of single sided welded plate connection test results is the subject of another paper.

Experimental study on deformation of concrete for shotcrete use in high geothermal tunnel environments

  • Cui, Shengai;Liu, Pin;Wang, Xuewei;Cao, Yibin;Ye, Yuezhong
    • Computers and Concrete
    • /
    • v.19 no.5
    • /
    • pp.443-449
    • /
    • 2017
  • Taking high geothermal tunnels as background, the deformation of concrete for shotcrete use was studied by simulating hot-humid and hot-dry environments in a laboratory. The research is made up by two parts, one is the influence of two kinds of high geothermal environments on the deformation of shotcrete, and the other is the shrinkage inhibited effect of fiber materials (steel fibers, polypropylene fibers, and the mixture of both) on the concrete in hot-dry environments. The research results show that: (1) in hot and humid environments, wet expansion and thermal expansion happened on concrete, but the deformation is smooth throughout the whole curing age. (2) In hot and dry environments, the concrete suffers from shrinkage. The deformation obeys linear relationship with the natural logarithm of curing age in the first 28 days, and it becomes stable after the $28^{th}$ day. (3) The shrinkage of concrete in a hot and dry environment can be inhibited by adding fiber materials especially steel fibers, and it also obeys linear relationship with the natural logarithm of curing age before it becomes stable. However, compared with no-fiber condition, it takes 14 days, half of 28 days, to make the shrinkage become stable, and the shrinkage ratio of concrete at 180-day age decreases by 63.2% as well. (4) According to submicroscopic and microscopic analysis, there is great bond strength at the interface between steel fiber and concrete. The fiber meshes are formed in concrete by disorderly distributed fibers, which not only can effectively restrain the shrinkage, but also prevent the micro and macro cracks from extending.

Dietary Phytoncide Supplementation Improved Growth Performance and Meat Quality of Finishing Pigs

  • Li, Han Lin;Zhao, Pin Yao;Lei, Yan;Hossain, Md Manik;Kang, Jungsun;Kim, In Ho
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.29 no.9
    • /
    • pp.1314-1321
    • /
    • 2016
  • We conducted this 10-wk experiment to evaluate the effects of dietary phytoncide, Korean pine extract as phytogenic feed additive (PFA), on growth performance, blood characteristics, and meat quality in finishing pigs. A total of 160 pigs ([Landrace${\times}$Yorkshire]${\times}$Duroc, body weight (BW) = $58.2{\pm}1.0kg$) were randomly allocated into 1 of 4 treatments according to their BW and sex, 10 replicate pens per treatment with 4 pigs per pen were used (2 barrows and 2 gilts). Dietary treatments were: CON, control diet; PT2, CON+0.02% PFA; PT4, CON+0.04% PFA; PT6, CON+0.06% PFA. Overall, average daily gain (ADG) was higher in PT4 (p<0.05) than in PT6, average daily feed intake (ADFI) was lower in PT6 than in CON (p<0.05). Besides ADFI decreased linearly (p<0.05) with the increased level of phytoncide and gain:feed ratio in PT4 treatment was higher (p<0.05) than CON treatment. During 5 to 10 weeks and overall, quadratic (p<0.05) effect was observed in ADG among the treatments. At the end of this experiment, pigs fed with PT4 diet had a greater (p<0.05) red blood cell concentration compared to the pigs fed CON diet. Water holding capacity increased linearly (p<0.05) with the increased level of phytoncide supplementation. Moreover, firmness, redness, yellowness, and drip loss at day 3 decreased linearly (p<0.05) with the increase in the level of phytoncide supplementation. In conclusion, inclusion of phytoncide could enhance growth performance without any adverse effects on meat quality in finishing pigs.

Effects of film liners, ethylene scrubber, alcohol releaser and chlorine dioxide on the berry quality during simulated marketing in 'Campbell Early' grapes

  • Kim, Sung-Joo;Choi, Cheol;Ahn, Young-Jik;Lim, Byung-Sun;Chun, Jong-Pil
    • Korean Journal of Agricultural Science
    • /
    • v.47 no.3
    • /
    • pp.415-424
    • /
    • 2020
  • This study investigated the effects of an ethylene scrubber (ES) with a micro-perforated polypropylene (MP-PP, 30 ㎛) or a high density polyethylene (MP-HDPE, 30 ㎛) film liner for the export carton packaging box in 'Campbell Early' grapes. Rachis browning was highest in the untreated group, followed by MP-PP and MP-HDPE for 14 days of simulated marketing at 20℃. The combination treatment of ES with the film liners showed a partial inhibition of the rachis browning regardless of the film liners. The effects of an alcohol releaser (AR) sachet or chlorine dioxide (CD) diffuser co-packaging were also investigated in the 'Campbell Early' grapes packed with the MP-HDPE (40 × 99 pin hole·m-2) film liner. The CD 1 g treatment showed a very limited weight loss of 1.1%, which was significantly lower than the 4.7% of the untreated control after 14 days of simulation marketing at 20℃. The berry shatter was 0.7% for the MP-HDPE + CD 1 g treatment and 1.8% for the MP-HDPE + CD 5 g treatment on the 10th day of the simulated marketing, which was significantly lower than the 8.9% of the control. The stem browning was significant suppressed until the 10th day of the simulated marketing. In particular, the CD 1 g treatment in combination with the MP-HDPE showed a low rachis and pedicel browning index of 2.0, which is 50% and 40% lower than that of the untreated control and the MP-HDPE single treatment, respectively. In addition, the CD 1 g treatment group showed a higher decay reduction effect than the CD 5 g treatment group, which caused high concentration damage.

Preparation of a axis oriented $YBa_2Cu_3O_{7-\delta}$ thin films by RF magnetron sputtering (RF 마그네트론 스퍼터링법에 의한 a-축 배향 $YBa_2Cu_3O_{7-\delta}$박막의 제조)

  • Lee, J.J.;Kim, Y.H.;Shin, J.;Lee, K.H.;Choi, S.S.;Hahn, T.S.
    • Korean Journal of Materials Research
    • /
    • v.4 no.4
    • /
    • pp.459-465
    • /
    • 1994
  • A-axis oriened YBCO thin flims were grown on $LaAIO_{3}$ single crystal substrate by off-axis rf magnetron sputtering method. We used two kinds of process to get a-axis oriented fi1ms;one-step process and two-step process. In one-step process, films are grown in single step in which substrate temperature( $T_s$) is in the range of $590^{\circ}C$ to $680^{\circ}C$. On the other hand, in two step process a-axis oriented thin film templates i f about 30nm thickness is deposited at low temperature first, and subsequently films are grown at elevated temperature to the final thickness of about 100nm. In the case of one step process($T_s$ ~)$600^{\circ}C$), prefered a-axis orientation is dominant and Cu-rich phases segregate at the surface. Segregations decrease and ($00 \ell$) peaks increase upon increasing $T_s$. The films prepared by two step method appeared to have strong(h00) peaks as the deposition rate increased. Microstructure shows pin holes resulted from mixed phases of a-axis and c-axis oriented films. In both cases of one step and two step process, as TS decreases, prepared films show stronger a-axis orientation. However electrical properties of the films are depressed with lower $T_c$ and wider $\Delta T$ as $T_s$ decreases.

  • PDF

Gastrointestinal Foreign Bodies in Children -Experiences of 60 Cases in Kangwon, Korea- (소아 위장관 이물 -강원지역 소아 60례-)

  • Lee, Young-Sub;Kang, Kae-Wool;Choi, Won-Kyu
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.4 no.2
    • /
    • pp.148-154
    • /
    • 2001
  • Purpose: Ingested foreign bodies present a common clinical problem. It is well known that most of them pass uninterrupted through the gastrointestinal tract. We evaluated the role of endoscopy and Foley catheter for removal of foreign bodies in the gastrointestinal tract. Methods: We investigated retrospectively 60 cases with foreign bodies in the gastrointestinal tract. They had been treated at Wonju Christian Hospital, Yonsei University of Korea, from January, 1996 through December, 1999. Results: The age of the patients ranged from 7 months to 13 years. Patients under 5 years were 57 cases (97%) and there was no significant difference in sex (M : F=1.07 : 1). 45 cases of the patients had no symptom. The most common foreign bodies were coins (43 cases). The most common location was esophagus (31 cases). The number of foreign body removal using flexible endoscopy and Foley catheter was 22 (36.7%) and 18 (30.0%) cases, respectively. In 18 cases (30.0%), foreign bodies passed spontaneously. Only 1 case (1.7%), curtain pin impaction at ileocecal region, required surgery. Conclusion: Early foreign body removal from esophagus and stomach is recommended to lessen the morbidity and complication. Fluoroscopic foley catheter technique and flexible endoscopy for removal of esophageal foreign bodies in children is safe and effective.

  • PDF

Design of Electromagnetic Moving-coil type Voice Coil Motor for Scanning mirror of Barcode reader (바코드 리더용 스캐닝 미러를 위한 무빙 코일 타입 VCM 설계)

  • Shin, Bu Hyun;Lee, Jeong Woo;Shim, Hyun Ho;Park, Sang Goo;Lee, Seung-Yop
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.1
    • /
    • pp.17-22
    • /
    • 2016
  • A voice coil actuator with moving coil type for scanning mirror system of barcode reader has been developed. The actuator has a simple structure including a magnet, a coil and a pin. The performance of the actuator is analyzed by a linearized theoretical model. And the dynamic performance of the proposed actuator is predicted through motor constant and restoring constant obtained by finite element simulations. The theoretical model was verified by the prototype which has 64 Hz resonance frequency and 60 deg reflecting angle. We also discovered that that 3 V input can make the actuator rotate over 61.8 deg reflecting angle at 50 Hz resonance frequency. The proposed actuator can simplify its driving configuration because of its implementation of open-loop control.

Evaluation of the Usefulness of Ancillary Devices for Patients with Acute Lumbar Pain During Magnetic Resonance Imaging (자기공명영상검사 시 급성 요추 통증 환자를 위한 보조기구의 유용성 평가)

  • Park, Hee-Wang;Lee, Moo-Sik;Kim, Yong-Kwon;Bae, Seok-Hwan
    • Journal of radiological science and technology
    • /
    • v.41 no.3
    • /
    • pp.193-199
    • /
    • 2018
  • The purpose of this study was to evaluate the convenience and image quality of patients with acute lumbar pain patients at a general hospital in Daejeon using ancillary devices for postural changes and correction. The results of the study are summarized as follows. First, the Turbo S pin Echo technique(TS E) using ancillary equipment has the highest image evaluation rating with an average score of 4.440, which is highly valuable on a diagnosis. Second, the average score for patient the questionnaire 'When using ancillary equipment, I feel that my body is calibrated to side without bias.' was shown as 4.440, which is very useful for the correction of the patient's body when using ancillary equipment. Finally, Breath Hold technique(BH) is very effective in shortening test time of acute lumbar pain patients, because it can reduce test time 86.4% faster than Turbo Spin Echo technique(TSE). The results of the study showed that the use of ancillary equipment to perform the test through the side lying postures helped to reduce the pain and control the patient's breathing, and the diagnostic value of the image was high.

Analysis for Cause of Corrosion and Gas Leakage on LP-Gas Cylinder (LP가스 용기의 부식 및 가스누출 원인 분석)

  • Choi S. C.;Jo Y. D.;Kweon J. R.;Kim J. Y.
    • Journal of the Korean Institute of Gas
    • /
    • v.5 no.1
    • /
    • pp.52-59
    • /
    • 2001
  • Factors to cause accidents were investigated through a systematic analysis of leakage accidents in welded LP-gas cylinder between 199 and 1999. As a result It was showed that most of leakage accident occurred at the pin-hole due to the localized corrosion on welded zone in cylinder. Accordingly, in this paper, we suggested that the problems of heat treatment condition in two-piece welded cylinder and substitute proposal for preventing the tearing of T zone in three-piece welded cylinder. Furthermore, corrosion rate on the weldment and base metal of welded LP-gas cylinder was evaluated using the electrochemical tests in acid rain and $3.5\%NaCl$ solution, Also, the poor adhesion and defects of film which was produced by electrostatic powder spray painting, while the LP-gas cylinder was manufactured, were analyzed using SEM(Scanning Electron Microscopy). And we proposed a optimum coating thickness of the cylinder.

  • PDF

Friction Characteristics of W100×L25 Micro Ellipse Type Pattern (W100×L25 마이크로 타원형 딤플패턴의 마찰특성)

  • Choi, Won-Sik;Kwon, Soon-Hong;Chung, Sung-Won;Kwon, Soon-Goo;Park, Jong-Min;Kim, Jong-Sun;Park, Dae-Young;Chae, Young-Hoon
    • Tribology and Lubricants
    • /
    • v.28 no.3
    • /
    • pp.136-141
    • /
    • 2012
  • In this paper, we investigated the friction characteristics of $W100^{\circ}{\o}L25m$ ellipse type surface pattern, on bearing steel. These characteristics are researched by utilizing a pin-on-disk wear test machine, under various velocities and other conditions. The reduction of friction is a necessary requirement for the improved efficiency of industrial parts. As the speed increases, there is a decrease in the effect of the dimple of friction characteristic in low velocity, with substantially little change to density. Conversely, as the load increases, the test direction of ellipse type dimple pattern, resulting in a difference in the texture of these two components. At a dimple density of 7.5% the friction characteristic is easily demonstrated, with a consistent change in both speed and load.