• Title/Summary/Keyword: At-Speed test

Search Result 2,585, Processing Time 0.029 seconds

A Study on the Formation and the Tribological Role of Mass Transfers Layers at Rubbing Silver-coated Surface (은 박막이 코팅된 표면에서 물질전이층의 형성 및 그 트라이볼로지적 역할에 관한 연구)

  • Yang, Seung-Ho;Kong, Ho-Sung;Yoon, Eui-Sung;Kim, Dae-Eun
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.45-52
    • /
    • 2002
  • The tribological role of mass transfer layer was studied with silver coatings under various ranges of load and sliding speed. Silver coating was performed with a functionally gradient coating method. Tests were performed in dry sliding conditions, using a ball-on-disk contact configuration, at the load of 0.0196-17.64 N and the sliding speed of 20-1,000 mm/s in ambient air. Optical microscope and EPMA analyses showed that contact surfaces were covered with the mass transfer layers of agglomerated wear particles depending upon the contact conditions, and they greatly influenced the tribological characteristics of the surfaces. However, the formation of mass transfer layer was suppressed as the sliding speed increased, and above a critical sliding speed, no mass transfer layer was able to form. For building up a general framework of tribological behavior of the coated silver films, all test data were summarized on a map whose axes are contact pressure and sliding speed.

  • PDF

Ion Pump Design for Improved Pumping Speed at Low Pressure

  • Paolini, Chiara;Audi, Mauro;Denning, Mark
    • Applied Science and Convergence Technology
    • /
    • v.25 no.6
    • /
    • pp.108-115
    • /
    • 2016
  • Even if ion pumps are widely and mostly used in ultra-high vacuum (UHV) conditions, virtually every existing ion pump has its maximum pumping speed around 1E-6 mbar (1E-4 Pa). Discharge intensity in the ion pump Penning cell is defined as the current divided by pressure (I/P). This quantity reflects the rate of cathode bombardment by ions, which underlies all of the various pumping mechanisms that occur in ion pumps (chemisorption on sputtered material, ion burial, etc.), and therefore is an indication of pumping speed. A study has been performed to evaluate the influence of magnetic fields and cell dimensions on the ion pump discharge intensity and consequently on the pumping speed at different pressures. As a result, a combination of parameters has been developed in order to design and build an ion pump with the pumping speed peak shifted towards lower pressures. Experimental results with several different test set-ups are presented and a prototype of a new 200 l/s ion pump with the maximum pumping speed in the 1E-8 mbar (1E-6 Pa) is described. A model of the system has also been developed to provide a framework for understanding the experimental observations.

Reconstruction of gusty wind speed time series from autonomous data logger records

  • Amezcua, Javier;Munoz, Raul;Probst, Oliver
    • Wind and Structures
    • /
    • v.14 no.4
    • /
    • pp.337-357
    • /
    • 2011
  • The collection of wind speed time series by means of digital data loggers occurs in many domains, including civil engineering, environmental sciences and wind turbine technology. Since averaging intervals are often significantly larger than typical system time scales, the information lost has to be recovered in order to reconstruct the true dynamics of the system. In the present work we present a simple algorithm capable of generating a real-time wind speed time series from data logger records containing the average, maximum, and minimum values of the wind speed in a fixed interval, as well as the standard deviation. The signal is generated from a generalized random Fourier series. The spectrum can be matched to any desired theoretical or measured frequency distribution. Extreme values are specified through a postprocessing step based on the concept of constrained simulation. Applications of the algorithm to 10-min wind speed records logged at a test site at 60 m height above the ground show that the recorded 10-min values can be reproduced by the simulated time series to a high degree of accuracy.

Analysis of Walking Speed According to Shoe type and Behavioral tasks (신발 유형과 행동 과제에 따른 보행 속도 분석)

  • Kim, Jae-Won;Jo, Yeon-Ha;Lee, Sun-Yeop;Lee, Mu-Ryeol;Kim, So-Jeong;Kim, Jin-A
    • Journal of Korean Clinical Health Science
    • /
    • v.5 no.4
    • /
    • pp.1015-1020
    • /
    • 2017
  • Purpose. Walking depends on the speed and type of shoe to be worn, and the degree of impact varies with the muscle used. In addition, the speed can be changed by moving objects and using objects when walking. This study analyzed the change of walking speed by applying various factors influencing walking. Methods. A total of 60 patients who had not undergone musculoskeletal diseases during the last 1 year were included. Shoe type was divided into slippers and shoe heels. Behavioral types were divided into bagging, books, and cell phone use. The walking speed was measured by the general walking, the middle walking, and the fast walking. The time was measured using a 10M linear distance test. The collected data were analyzed with SPSS program for independent samples t-test, one-way ANOVA. Results. There was a statistically significant difference according to the type of shoes when walking. Walking speed was slow in shoe heel. In addition, There was statistically significant difference according to type of behavior task at walking. Walking speed was slow in task type using mobile phone during walking. Conclusions. The walking speed were appeared difference in each type of shoe heel, using mobile phone.

Analysis of friction stir welding characteristics of aluminum alloy using machining center (머시닝센터를 활용한 알루미늄합금의 마찰교반용접 특성 분석)

  • Seung, Young-Chun;Park, Kyoung-Do;Lee, Chun-Kyu
    • Design & Manufacturing
    • /
    • v.14 no.4
    • /
    • pp.46-51
    • /
    • 2020
  • The purpose of this study was to analyze the change in tensile strength characteristics of the weld when the welding speed and rotational speed of the tool, which are representative variables of the friction stir welding process. The equipment used in the experiment was Machining Center No. 5. The material used in the experiment is an AA6061-T6 alloy, and a rolled plate with a thickness of 2mm was used. Two experimental variables were selected, the welding speed of the tool and the rotational speed of the tool. The experimental conditions were selected in the range in which a healthy weld could be obtained through a preliminary experiment. The welding speed of the tool was increased to 100mm/min, 200mm/min, and 300mm/min, and the rotational speed of the tool was increased to 1000rpm, 2000rpm, and 3000rpm. As a result of the experiment, the tensile strength increased as the rotational speed of the tool changed at each tool welding speed. In addition, as the welding speed of the tool increased, the tensile strength of the weld was increased. The condition with the highest tensile strength of the weld was found to be a tool feed speed of 300 mm/min and a tool rotation speed of 3000rpm.

Study on the Wear Resistance of Gray Cast Iron in Laser Surface Hardening (레이저 표면경화처리된 회주철의 내마모특성에 관한 연구)

  • Park, K.W.;Han, Y.H.;Lee, S.Y.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.9 no.4
    • /
    • pp.271-280
    • /
    • 1996
  • This study has been performed to investigate into some effects of power density and traverse speed of laser beam on optical microstructure, hardness and wear characteristics of gray cast iron treated by laser surface hardening technique. Optical micrograph has shown that large martensite and a small amount of retained austenite appear in outermost surface layer with fine martensite in inside hardened zone. Hardness measurements have revealed that the range of maximun hardness value is $Hv=650{\pm}15$ and as the power density increases and the traverse speed decreses, the depth of hardened zone increases due to as increase in input power density. Wear test has exhibited that wear rasistance of laser surface hardened specimen is superier compared to that of untreated specimen under the condition of same load at a given sliding distance, showing that absorption results of an wxidized substance due to a heavy abrasion appear in untreated specimen. The amount of weight loss of laser surface hardened specimen with respect to sliding distance at a given load decreses with increasing traverse speed at a given power density and with increasing power density at a given traverse speed.

  • PDF

The Effectiveness Analysis on Set of Ramp Metering STOP-line Using Traffic Simulation Model (교통시뮬레이션 모형을 이용한 램프미터링 정지선 설정에 따른 효과분석)

  • Kim, In Su;Yang, Choong Heon
    • International Journal of Highway Engineering
    • /
    • v.16 no.1
    • /
    • pp.111-118
    • /
    • 2014
  • PURPOSES : This study performs fundamental research on ramp-metering design criteria. METHODS : We carefully review previous studies in terms of ramp-metering design criteria and then consider applicability in Korea. For this, traffic simulation model is employed to analyze actual effect according to specific location of stop-line when implementing ramp-metering. RESULTS : When a stop-line moving forward with a 50m interval, travel speed at mainline relative to current stop-line location tends to decrease. However, traveling speed at approach roads increase about 5~18% under the same condition. When a stop-line location moving backward with a 50m interval, mainline travel speed increase approximately 17~32% whereas traveling speed at approach roads decrease. All cases are compared with the current stop-line location. CONCLUSIONS : We believe that both cases are useful with respect to freeway management. For example, moving forward a stop-line case can be used management for queuing area at ramp section and approach roads. Moving backward a stop-line case can be used for traffic control, focusing on mainline of freeways.

Analysis of Sliding Wear Behavior of Mild Steel According to Hardness of Dissimilar Mating Materials (이종 상대재 경도에 따른 철강재료의 미끄럼 마모 특성 해석)

  • Lee, Han-Young
    • Tribology and Lubricants
    • /
    • v.32 no.6
    • /
    • pp.195-200
    • /
    • 2016
  • This study examines the wear behavior of mild steel pins mated against alloyed tool steel discs in a pin-on-disc type sliding test machine and provides specific clarification regarding the effects of disc hardness on the wear behavior of a mating mild steel pin. The analysis confirms these effects through the observation of differences in the wear rates of the mild steel pins at low sliding speed ranges. These differences occur even though the hardness of the mating disc does not affect the wear characteristic curve patterns for the sliding speeds, regardless of the wear regime. In the running-in wear regime, increasing the hardness of the mating disc results in a decrease in the wear rates of the mild steel pins at low sliding speed ranges. However, in the steady-state wear region, the wear rate of a pin mated against the 42DISC is greater than the wear rate of a pin mated against the 30DISC, which has a lower hardness value. This means that the tribochemical reactivity of the mating disc, which is based on hardness value, influences the wear behavior of mild steel at low sliding speed ranges. In particular, oxides with higher oxygen contents, such as $Fe_2O_3$ oxides, form predominantly on the worn surface of the 42DISC. On the contrary, the wear behavior of mild steel pins at high sliding speed ranges is nearly unaffected by the hardness of the mating disc.

Laser Weldability of Sheet steels for Tailored Blank Manufacturing(1) (테일러드 블랭크용 박판 강재의 레이저 용접성 (1))

  • 김기철
    • Journal of Welding and Joining
    • /
    • v.16 no.1
    • /
    • pp.77-87
    • /
    • 1998
  • This paper deals with the effect of laser welding parameters on the weld formation. Thin steels for automotive application were prepared so as to be welded with high power carbon dioxide laser system. Major process parameters were position of focus and travel speed. The effect of shielding gas was also discussed by employing the high speed photometry. Test results showed that the optimal position of focus varied in accordance with the joint configuration; bead-on-plate, butt or lap welding. It was recommended that the position of focus for the lap welding be located at slightly inner part of the material to be welded. In this case, however, it was noticeable that the weld penetration ratio, d/t$_{0}$ dropped drastically at the critical region. Results also demonstrated that both the bead width and penetration reduced as the travel speed increased. The penetration ratio showed two distinct regions; stabilized zone at the lower range of the travel spped and sudden drop zone at the higher range of travel speed. Lower limit of the penetration for acceptable weld was proved to be about 90% of the parent metal thickness based on the physical properties of the weld. Mixed gas application for both the shielding of molten metal and laser induced plasma control was recommended as far as the penetration was concerned.d.

  • PDF

Development of the Driving Pump for the Super-cavitation & High-speed Cavitation Tunnel (초공동 고속 캐비테이션 터널 구동펌프 개발)

  • Ahn, Jong-Woo;Kim, Gun-Do;Paik, Bu-Geun;Kim, Kyoung-Youl
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.55 no.2
    • /
    • pp.153-160
    • /
    • 2018
  • In order to develop the driving pump for High-speed Cavitation Tunnel(HCT) which can experiment the super-cavitating submerged body, KRISO decided on the pump specification, designed the mixed-flow pump on the basis of the existing pump data and predicted the performance of the design pump using commercial CFD code (CFX-10). After the manufacture and installation of the driving pump, KRISO conducted the trial-test for HCT, analyzed the pump performance and compared trial-test results to those of design stage. The trial-test items for the HCT driving pump are measurements of output current/voltage at the inverter of the driving pump and the flow velocity in the HCT test section. The trial-test results showed the decrease in the flow rate of about 4.6% and the increase in pump head of about 8%, compared with those of the pump prediction. After the trial-test, the performance of the driving pump is predicted using CFX-10 with measured flowrates and pump rotational velocities. Though there is some difference between trial-test and prediction results due to inadequate motor data, it is thought that the tendency is reasonable. It is found that CFX-10 is useful to predict a mixed-flow pump.