• Title/Summary/Keyword: Asymmetrical current

검색결과 103건 처리시간 0.026초

Step-Up Asymmetrical Nine Phase Delta-Connected Transformer for HVDC Transmission

  • Ammar, Arafet Ben;Ammar, Faouzi Ben
    • Journal of Power Electronics
    • /
    • 제18권6호
    • /
    • pp.1920-1929
    • /
    • 2018
  • In order to provide a source for nine phases suitable for 18-pulse ac to dc power, this paper proposes a new structure for a step-up asymmetrical delta-connected transformer for converting three-phase ac power to nine-phase ac power. The design allows for symmetry between the nine output voltages to improve the power quality of the supply current and to minimize the THD. The results show that this new structure proves the equality between the output voltages with $40^{\circ}-{\alpha}$ and $40^{\circ}+{\alpha}$ phase shifting and produces symmetrical output currents. This result in the elimination of harmonics in the network current and provides a simulated THD that is equal to 5.12 %. An experimental prototype of the step-up asymmetrical delta-autotransformer is developed in the laboratory and the obtained results give a network current with a THD that is equal to 5.35%. Furthermore, a finite element analysis with a 3D magnetic field model is made based on the dimensions of the 4kVA, 400 V laboratory prototype three-phase with three-limb delta-autotransformer with a six-stacked-core in each limb. The magnetic distribution flux, field intensity and magnetic energy are carried out under open-circuit operation or load-loss.

비대칭 하프 브릿지 직류-직류 컨버터에 적용된 전류 제어의 성능평가 비교 (Comparative Performance Evaluation of Current-Mode Controls Adapted to Asymmetrical Half-Bridge Dc-to-Dc Converters)

  • 임원석;최병조;박성우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.257-260
    • /
    • 2005
  • Three different current-mode control schemes, peak current-mode control, charge control, and average current-mode control, are investigated for applications to asymmetrical half-bridge dc-to-dc converters. The principles, implementation, and performance of the three control schemes are compared in an attempt to identify the irrespective merits and limitations. Design examples for feedback compensations are given for the three control schemes. A 50 W experimental asymmetrical half-bridge dc-to-dc converter was used to experimentally verify the theoretical results of the paper.

  • PDF

전류 제어 비대칭 하프 브릿지 직류-직류 컨버터의 동특성 해석 및 제어회로 설계 (Dynamic Analysis and Control Design of Current-Mode Controlled Asymmetrical Half-Bridge DC-To-DC Converters)

  • 임원석;최병조
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(1)
    • /
    • pp.337-340
    • /
    • 2003
  • This paper presented practical details about control-loop design and dynamic analysis for a peak current-mode controlled asymmetrical half-bridge(ASHB) do-to-dc converter, Graphical loop gain method is used to design the feedback compensation and analyze the closed-loop performance of ASHB converter. The results of the control design and closed-loop analysis are validated by experiments on a prototype converter.

  • PDF

전하 제어를 적용한 비대칭 하프 브리지 직류-직류 컨버터 (An Asymmetrical Half-Bridge Dc-to-Dc Converter Employing Charge Control)

  • 임원석;최병조
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.1184-1186
    • /
    • 2003
  • In this paper, a charge controlled asymmetrical half-bridge (ASHB) dc-to-dc converter is presented. For ASHB do-to-dc converter, the peak current-mode control was found to be problematic primarily due to the oscillatory behavior of the current feedback signal. To resolve this problem, a charge control method is applied to the ASHB do-to-dc converter. A 50W prototype ASHB dc-to-dc converter was built, and successfully tested.

  • PDF

비대칭과도 전류와 과전류계전기의 동작시간 특성에 관한 연구 (Study on the Asymmetrical Fault Currents and the Operating Time Characteristics of OCR)

  • 김남호;김일남;박종근
    • 대한전기학회논문지
    • /
    • 제41권9호
    • /
    • pp.953-959
    • /
    • 1992
  • As the TC(time-current) curve corresponding to symmetrical time invariant RMS value has been traditionally chosen and used for setting the relay, it has caused the misoperation errors on relay coordination because of CT secondary current being actually an asymmetrical time varying RMS value. In this paper, an algorithm for calculating the relay operating time is developed to study the asymmetrical effect using the step-by-step method. We represent the relay operating time errors between with and without DC offset versus PSM(plug setting multiplier), TMS(time multiplier setting) and X/R ratio. And also we present the correction factor. Finally we confirm the validity of this technique through the case study.

조선시대 측4량가 건축의 구조와 특징 (A study on the Structure and Design Concept of Asymmetrical Building with 4 Purlins in the Joseon Dynasty)

  • 김버들;이종서
    • 건축역사연구
    • /
    • 제28권6호
    • /
    • pp.7-18
    • /
    • 2019
  • This study is to find out the design concept of asymmetrical building with 4 purlins mainly in Sungkyunkwan(Confucian Shrines), Changgyeonggung palace and Changdeokgung palace The results are as follows: First, asymmetrical building with 4 purlins has the same height pillars, which was useful to control the side lenght and put a higher pillar without limit. Second, the side length of the asymmetrical building with 4 purlins is between 12 to 14 Ja[尺]. It's relatively longer than the minimum length(12 Ja) of 5 purlins architecture seen in later Joseon dynasty. Third, asymmetrical building with 4 purlins was not an anomalous structure when compared to 3 purlins and 5 purlins. It was actually a traditional style, unlike the current architectural recognition nowadays, which mainly focused on the balanced roof structure. These examples show that the architectures in Early Joseon dynasty were planned and constructed first according to the plane division that fit in a specific use or space.

A New Fast P2P Video Transmission Method Applied in Asymmetrical Speed Channel Environment

  • Wang, Zhang;Zhang, Jixian;Li, Haitao;Liu, Jian
    • Journal of Communications and Networks
    • /
    • 제12권3호
    • /
    • pp.209-215
    • /
    • 2010
  • In an asymmetrical speed channel environment like asymmetric digital subscriber line, the up-link bandwidth is normally smaller than the down-link bandwidth, which will lead to extremely low utilization of down-link bandwidth when current P2P video transmission is applied. To overcome this, a new fast P2P video transmission method applied in an asymmetrical speed channel environment is proposed in this paper. On the basis of the many-to-one concept, the proposed method uses a new multipeer aggregation technique to enhance the utilization of down-link bandwidth. In addition, an adaptive peer assignment algorithm is also introduced in order to minimize the overall transmission time. Experimental results show that by using our proposed method, the utilization of down-link bandwidth is significantly improved, and the overall transmission time is greatly reduced.

전류파형을 변조한 단상유도전동기구의 특성에 관한 연구 (Performances of Current-Waveform Modulated Single-Phase Induction Machine)

  • 황영문;김철우;박용규
    • 전기의세계
    • /
    • 제24권1호
    • /
    • pp.55-62
    • /
    • 1975
  • A single-phase induction motor with it's stator winding splitted into two series windings, of which the terminals of one winding is switched pulsationally by a thyristor type ON-OFF device so that the motor may operate as a pulsational shaded-pole motor, can modulate current waveforms of it's two series windings. In view of current waveform modulation method, a single-phase single-winding motor operates as a two-phase induction motor with asymmetrical axis windings where the starting torque can be obtained effectively without an auxiliary capacitor attached and it's running speed controlled by shifting phase between current waveforms differently. Equivalent circuit for analysis is modified from a double revolving field equivalent circuit of a single-phase induction motor with asymmetrical windings whose angle is 45.deg.C elet. degrees. Analysis and test results show that ON-OFF action of the pulsational shaded-pole winding has the same effect of a series capacitor, and then at heavy loads this motor operates with a small amonut of the input current than that having the fixed shaded-pole winding.

  • PDF

3차원 와전류 해석을 위한 등가자기회로방법의 개발 (Development of Equivalent Magnetic Circuit Network Method for 3 Dimentional Eddy current Analysis)

  • 허진;홍정표;현동석
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권5호
    • /
    • pp.228-233
    • /
    • 2002
  • A computational method for analysis of the 3 dimensional electro-magnetic induction problems has been developed. The developed method is capable of modeling the induced current and analyzing its characteristics using only scalar Potential at each node. A benchmark model of asymmetrical conductor with a hole is analyzed to verify the application of the developed method. The calculated value of magnetic flux density are compared with the measured value, and the results indicate that the developed method is valid. Also, Comparing with 3-D finite element method (FEM) results, we conformed effectiveness of the developed method for the accuracy and computation times.

비대칭 전압 불평형에 의한 커패시터 동작 특성 (A Study on the Characteristic of Capacitor by Asymmetrical Voltage Unbalance)

  • 김종겸;박영진
    • 전기학회논문지P
    • /
    • 제59권1호
    • /
    • pp.18-23
    • /
    • 2010
  • As the increasing of Non-linear load, we have been growing interest for the harmonics. Harmonics has been focused on the current component rather than voltages. Voltage harmonics can be mainly generated at the PCC with non-linear load and act on voltage unbalance. Voltage harmonics can be enlarged at the capacitor with low impedance as frequency increases. Capacitor is basically used for the power-factor compensation and sometimes as the passive filter. Small voltage of low-order acts on quite a few at the capacitor by the current increase. Capacitor has easily fall under by harmonic components. In this paper, we measured the magnitude and phase angle of asymmetrical voltage with harmonics components at the PCC and calculated with the same condition. we concluded that voltage harmonics of higher order increase each current component but have a little effect on capacitor rating.