Micro Displacement Sensor Using an Astigmatic Method (비점수차법을 이용한 변위센서 개발)

  • Lee C.W.;Song J.Y.;Ha T.H.;Kim J.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.257-258
    • /
    • 2006
  • This paper presents the displacement sensor based on astigmatic method that has a small measurement range. The sensor has the characteristic that the measuring range is changed easily by exchanging a objective lens or distance between a objective lens and a collimator lens. The measuring range and resolution is evaluated by a laser interferometer.

  • PDF

Astigmatic Rainbow Hologram Using the Characteristics of Holographic Aberration (홀로그램의 비점수차 특성을 이용한 무지개 홀로그램 연구)

  • 홍석경;백성훈;김철중
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.3
    • /
    • pp.372-378
    • /
    • 1994
  • A simple 2-step astigmatic rainbow holography method using the characteristics of holographic aberration is proposed. Point sources are used to record and reconstruct primary hologram. When the primary hologram is reconstructed, object image is divided into two components by the holographic astigmatism. This characteristics of holographic astigmatism and cylindrical lens power are used to obtain rainbow hologram of sharp image, no matter how far from the hologram the obseved image locates, in front of the hologram. And this hologram has optimum viewing distance long enough.enough.

  • PDF

Displacement measurement sensor using astigmatic confocal technology

  • J.W. Seo;D.K. Kang;Lee, J.H.;Kim, D.M.;D.G. Gweon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.163.2-163
    • /
    • 2001
  • Confocal scanning microscopy (CSM) has been reported as an excellent method using the optical probe in scanning probe microscopy (SPM). Transmission or reflection confocal scanning microscopy (TCSM, RCSM) has been used in the three-dimensional reconstruction of specimen or the non-destructive measurement in vivo. The axial movement of the primary focal point having the information of specimen gives a good measurement performance with the great sensitivity. Application of the confocal theory and astigmatism to displacement measurement sensor uses the aperture as the pinhole or slit after collecting lens relating to confocal response in non-contact measurement; and astigmatic lens using four-segments detector as short-range sensor, long-range one combining the grating and rotary one hating the rotary directional grating. The aperture type can play an ...

  • PDF

A Study on the Relationship between the Disc of Least Confusion and Corrected Vision of Astigmatism (난시안의 최소착락원과 교정시력과의 관계 연구)

  • Kim, Jung-Hee;Kim, In-Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.2
    • /
    • pp.51-57
    • /
    • 2008
  • Purpose: This study has been conducted to know how the size and position of the circle of least confusion has an influence on the vision for minimization of asthenopia when astigmatism is corrected and appropriated prescription to provided clear vision life. Methods: The method of the study has been worked on 68 students (136 eyes) of man and woman enrolled in university of Gyeong-gi-do aged 20 to 40, who have myopic astigmatism in order to know how the corrected vision changes according to the size and position of the circle of least confusion of astigmatism, the vision has been tested by giving the vision whose astigmatic power of 0.25D and 0.50D was just reduced, low correcting the astigmatic power into 0.50D, and at the same time inserting additionally spherical power -0.25D, all under a condition that the corrected vision after completely corrected astigmatism, and the axis of astigmatism was not changed. Results: The average vision was 1.047 when the astigmatic power was fully corrected, and in low correction of 0.25D, it was 0.914, and in low correction of 0.50, it was 0.772. It has been learned that the bigger the circle of least confusion was the bigger the range of vision reduction and the corrected vision in astigmatism has correlation with the size of the circle of least confusion. It has been examined that the average vision according to position of the circle of least confusion in astigmatism was 1.047 when the astigmatic power was completely corrected and focused on the retina with state of point, and in case that the astigmatic power was 0.50D of state of low correction, that is, the circle of least confusion was focused before retina, it was 0.828, and it was also 0.826 when the astigmatic power is low corrected with 0.50D and the circle of least confusion was focused on the retina. Explained briefly, It has been examined that in case that the state of low correction of the astigmatic power was same, the vision reduction was less in the image of the circle of least confusion focused upon the retina than in the image of its being focused before the retina. Conclusions: In case that the refractive power of cylindrical lens is reduced in test of wearability in astigmatism, there needs surely an adjustment of spherical lens that can place the circle of least confusion on the retina.

  • PDF

DVD와 호환 가능한 홀로그래픽 롬 시스템

  • Mun Jin-Bae;Kim Geun-Yul;Jeong Gyu-Il;Park Ju-Yeon;Nam Eun-Ha
    • 정보저장시스템학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.145-149
    • /
    • 2005
  • We describe holographic ROM system to read bit-type data. It has optical system similar to general optical data storage system such as DVD. But because holographic data storage systems have to adopt imaging optical system, in our system bit-type data can be read out by different servos with DVD. We devised 3-hole method similar to 3- beam method for the tracking servo and used astigmatic optical system for the focusing servo. Also we developed the reference beam servo to measure movement of reference beam because especially holographic data storage systems need reference beam. The system was operated by these three servos and objective lens of NA 0.6. We obtained eye pattern from random data of 3T-2um track pitch. We also obtained another eye pattern from DVD disk by only using focusing servo PDIC in our system to verify the compatibility with DVD.

  • PDF

A Study on the Dynamic Characteristics of on-shore Ground Using Suspension P. S. Logging (서스펜션 P.S. 검층을 이용한 해저 지반의 동역학적 특성에 관한 연구)

  • 김용수;정승용;장찬수;김수삼
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.10a
    • /
    • pp.357-364
    • /
    • 1999
  • In recently site investigations, the need for the determination of dynamic soil properties such as dynamic modules of rigidity, elasticity, dynamic poison's ratio and damping ratio etc. is increasing for the astigmatic designs of the civil structures. To obtain some of the dynamic properties, measurement of elastic waves velocity, both P and S wave, is required. Among various methods to measure elastic wave velocity such and Down Hole, Cross Hole and Refraction etc., Suspension P.S. Logging has an advantage to use for the off-shore investigation where generation of the shock wave and traveling of the wave is difficult. In suspension P.S. logging, specially designed prove equipped with source of shock wave, two 3-channel receivers, departing 1m distance, and other auxiliary facilities is inserted down in a bore hole bottom and raised in predetermined interval, usually 1m or 2m, and measurement is conducted. P.S. logging have been conducted in a off-shore construction project near InChon in the west coast for the first in the country, and form the result, potential of the liquefaction of the subsoil was evaluated and compared with the conventional method.

  • PDF

A Study on the Ametropia of High School Students in Jeonbuk Province (전북 지역 고등학생 비정시에 관한 연구)

  • Doo, Ha-Young;Sim, Sang-Hyun;Choe, Oh-Mok;Gang, Myoung-Jin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.2
    • /
    • pp.67-71
    • /
    • 2002
  • To investigate the ametropia and refractive error of 364 ametropic eyes en the 182 high school students in Jeonbuk provicne, the visual acuity test was performed by the object and subject method. The results were as follows. 1. The eye types were 85.7% positive for myopia, 6.6% for emmetropia and 7.6% hyperopia, respectively. 2. The abnormal refraction eyes were 30.8% positive for simple myopia, 58.5% for myopia compound astigmatism, 7.5% for myopia simple astigmatism, and 1.8% for simple hyperopia, 1.3% for hyperopia compound astigmatism, 1.9% for hyperopia simple astigmatism, respectively. 3. The axes of astigmatism were 78.7% for astigmatism with-the-rule, 13.9% for astigmatism against-the-rule, 7.4% for astigmatism oblique, respectively. 4. As for the astigmatic power, the 0.50 < cylinder < 1.00dptr was 60.0%, the 1.00 < cylinder < 2.00dptr was 29.2%, and anything over the 2.00cylinder dptr was 10.8%. 5. As for the equivalent spheric power of myopic abnormal refraction eyes, the -0.50 < spheric equivalent < -2.00 diopter was 64.6%, the -2.00 < spheric equivalent < -6.00 dptr was 29.1% and anything over the -6.00 dptr was 6%. 6. The equivalent spheric power of hyperopic abnormal refraction eyes was 50% anything under 2.00diopter and 50% for anything over the 2.00diopter.

  • PDF

Relationship on the Refractive Status of the High School 3rd Grade Students with Subnormal Visual Acuity in Gwangju Metropolitan City (광주지역 고등학교 3학년생의 비정시안의 굴절상태에 대한 고찰)

  • Yoon, Young;Ryu, Geun-Chang
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.3
    • /
    • pp.105-110
    • /
    • 2007
  • To investigate the ametropia and refractive error of 222 ametropic eyes of the 111 high school students in Gwangju Metropolitan City, the visual acuity test was performed by the object and subject method. 85% of the eye types were positive for myopia, 14% for emmetropia, and 1% for hyperopia, respectively. 38% of the abnormal refraction eyes were positive for simple myopia, 4% for myopia simple astigmatism, 56% for myopia compound astigmatism, and 0% for simple hyperopia, 0% for hyperopia simple astigmatism, 2% for hyperopia compound astigmatism, 0% for mixed astigmatism, respectively. 92% of the axes fo astigmatism were for astigmatism with-the-rule, 6% for astigmatism against-the rule, 2% for astigmatism oblique, respectively. As for the astigmatic power, 0.50 < cylinder < 1.00D was 68%, 1.00 < cylinder < 2.00D was 25%, and anything over the 2.00 cylinder D was 7%. As for the equivalent spheric power of myopic abnormal refraction eyes, -0.50 < spheric equivalent < -2.00D was 26%, -2.00D < spheric equivalent < -6.00D was 55% and anything over the -6.00D was 19%. The rate of wearing glasses was 74%. It increases compared to 20 years ago. 91% of the eye test place was the optical shop, 9% the eye doctor hospital. 80% of the students need to change their optical lenses because spherical equivalent power was over 0.50D.

  • PDF

The Study of the Abnormal Refraction Eye of the Primary School Children in Daegu (대구지역 초등학생 굴절이상안에 대한 연구)

  • Kim, Dae Nyoun;Kim, Hye Dong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.1
    • /
    • pp.49-53
    • /
    • 2001
  • To investigate the visual acuity of the primary school children. the visual acuity test wan performed the object and subject method. The results were follows. 1. The eye types were 94.8% positive for myopia, 1.2% for emmetropia and 4.0% hyperopia, respectively. 2. The abnormal refraction eyes were 71.3% positive for simple myopia, 17.9% for myopic compound astigmatism, 6.9% for myopic simple astigmatism, and 2.5% for simple hyperopia, 0.6%for hyperopic compound astigmatism, 0.8%for hyperopic simple astigmatism, respectively. 3. The axis of astigmatism were 72.8% for astigmatism with-the-rule, 23.2% for astigmatism against-the-rule, 4.0% for astigmatism oblique, respectively. 4. On the total myopic spheric power, the -0.50

  • PDF