• Title/Summary/Keyword: Assurance

Search Result 2,311, Processing Time 0.026 seconds

Quality Assessment and Comparison of Several Radioimmunoassay Kits and Chemiluminescence Immunoassay Methods for Evaluating Serum Estradiol (혈중 Estradiol 농도 측정을 위한 여러 방사면역측정 검사키트 및 화학면역발광 검사법의 성능평가 및 상호비교)

  • Choi, Sung Hee;Noh, Gyeong Woon;Kim, Jin Eui;Song, Yoo Sung;Paeng, Jin Chul;Kang, Keon Wook;Lee, Dong Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.72-80
    • /
    • 2015
  • Purpose Serum estradiol ($E_2$) measurement is requested for diagnosing menstrual cycles, ovulation induction, infertility, and menopause. $E_2$ is measured using several methods and kits including radioimmunoassay (RIA) and chemiluminescece immunoassay (CLIA). The purpose of this study was to evaluate quality of these methods and to compare them with each other. Materials and Methods Seven radioimmunoassay kits and two CLIA methods were included in the analysis. Using standard samples and patient samples, intra-assay precision, inter-assay precision, correlation between other methods, sensitivity, and recovery rate were evaluated. Results For all tested kits and methods, coefficients of variance (CVs) of intra-assay precision test were 10.9~13.6% in low-level samples and less than 10% in medium and high-level samples. CVs of inter-assay precision test were 10.8~12.3% in low-level samples and less than 10% in medium and high-level samples with all tested kits and methods. Recovery rates were $92.7{\pm}12.4%$ for SIEMENS, $101.4{\pm}18.4%$ for DIAsource, $95.1{\pm}11.5%$ for AMP, $108.4{\pm}18.5%$ for BECKMAN COULTER, $104.2{\pm}13.5%$ for BECKMAN COULTER Ultra Sensitive, $101.3{\pm}11.6%$ for CIS Bio, and $93.1{\pm}13.2%$ for MP kits. Sensitivity was 7.5, 6.2, 5.7, 6.2, 5.3, 4.5, and 5.5 pg/mL for SIEMENS, DIAsource, AMP, BECKMAN COULTER, BECKMAN COULTER Ultra Sensitive, CIS Bio, and MP kits, respectively. The measurement by MP kit was slightly higher than those by other kits in low-level samples, and the measurement by E170 was slightly higher than those of other kits in medium and high-level samples. In the measurement of standard sample for external quality control, SIEMENS kit produced relatively lower values whereas E170, Architect, and MP kits produced relatively higher values compared with other kits. Conclusion All tested kits for $E_2$ measurement have satisfactory performance for clinical use. However, correlation between kits should be considered when test kits are to be changed, because some pairs of kits do not have correlations with each other.

  • PDF

Classification of submitted KSNMT dissertation (대한핵의학기술학회 투고 논문 분류)

  • Han, Dong-Chan;Lee, Hyuk;Hong, Gun-Chul;Ahn, Byeong-Ho;Choi, Seong-Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.65-69
    • /
    • 2017
  • Purpose KSNMT(Korea Society of Nuclear Medicine Technology) stepping first step in 1997, has published first journal related with nuclear medicine technology in 1985. With classifying In Vivo Session Dissertation reported in the entire journal, trend of the Dissertation will be studied. Materials and Methods Dissertations which published from 1985 to first half of 2016 in the journal are classified with presentation form and with scanner, And all the data is organized with Excel program. Through the data, the number of dissertations published in each year, the number of dissertation published in details, and keyword distributions in each period are analyzed. Results The number of In-vivo section dissertations was 1151 and the number of In-vivo section dissertations that have common subject with In-vitro section was 28. The number of In-vivo section dissertation in 1980s was 46, in 1990s was 149, in 2000 was 467 and from 2010 to the first half of 2016 was 517. The number of dissertation with original articles was 571, with abstract was 529, with symposium was 31, with special lecture was 25, with review was 11, with interesting image was 7, with poster was 3 and with case report was 2. With symposium and special lecture excluded, which count 56, the number of dissertation with PET was 319, with Planar was 302, with SPECT was 172, with radiopharmaceutical was 113, with guard and safety management 103, with BMD was 28, etc. was 86. The number of dissertation about oncology was 201, about scanner was 179, about cardiovascular and circulatory system was 102, about safe environment was 82, about musculoskeletal system was 76, about nervous nuclear medicine was 66, about quality assurance was 61, about genitourinary system was 56, about endocrine system was 49, about digestive system was 44, about Therapy, about industrial safety was 24, about molecular imaging was 15, infection and inflammation was 9, about respiratory system was 8 and etc. was 108. The mostly used keyword through 1999 to 2005 was PET and through 2006 to 2016 was PET/CT. Conclusion To encourage various dissertations to be submitted, Korea Society of Nuclear Medicine should analyze date about not only about dissertations that are already published, but also about various research materials. Moreover, Korea Society of Nuclear Medicine also have to provide technical support such as sharing big data from homepage and systematical support to its member to publish dissertation that has high impact factor. It is important each individual researcher to have continuing effort as well as each organization cooperation.

  • PDF

Report on the External Quality Assessment Scheme of Hepatitis Viral Markers in Korea, (2016-2017) (간염바이러스 항원항체검사 신빙도조사 결과보고 (2016-2017))

  • Cho, Eun-Jung;Choi, Ae Ran;Ryu, Ji Hyeong;Yun, So Jeong;Lee, Woochang;Chun, Sail;Min, Won-Ki;Oh, Eun-Jee
    • Laboratory Medicine and Quality Assurance
    • /
    • v.40 no.2
    • /
    • pp.51-69
    • /
    • 2018
  • As part of the immunoserology program of the Korean Association of External Quality Assessment Service, we organized two trials on the external quality assessment of hepatitis viral markers in 2016 and 2017. The hepatitis viral antigens and antibodies program consisted of 10 test items. We delivered two and three types of pooled sera specimens to 965 and 965 institutions for the first and second trials of external proficiency testing in 2016, respectively. The number of participating laboratories was 915 (94.8%) and 913 (95.0%) in the first and second trials in 2016, respectively. We also delivered three kinds of pooled sera specimens to 936 and 1,015 institutions for the first and second trials of external proficiency testing in 2017, respectively. The number of participating laboratories was 920 (98.3%) and 996 (98.1%) in the first and second trials in 2017, respectively. The most commonly tested items were hepatitis B surface antigen, followed by the antibodies to hepatitis B surface antigen, anti-hepatitis C virus, hepatitis B envelope antigen, antibodies to hepatitis B envelope antigen, anti-hepatitis A virus and antibodies to hepatitis B core antigen. The most frequently used methods for detecting viral markers were the chemiluminescence immunoassay and the electrochemiluminescence immunoassay, but they yielded a few-false positive results due to the matrix effect. The immunochromatographic assay yielded false-negative results for anti-hepatitis A virus due to low sensitivity. Continuous improvement in the quality of viral hepatitis testing through participation in the survey seems necessary.

An Analysis on the Suicide Concept, its Religious Circuit and Construction Way: Focused on the cases of the Korean Catholic and Protestant Churches (자살 관념의 종교적 회로와 구성 방식에 관한 분석: 한국 가톨릭교회와 개신교를 중심으로)

  • Park, Sang Un
    • The Critical Review of Religion and Culture
    • /
    • no.31
    • /
    • pp.255-287
    • /
    • 2017
  • This paper analyzes the religious circuit of suicidal concept based on verbal expression and ritual acts, which are found in the suicide discourse of Korean Catholic Church and Protestant Church. In the relationship of suicide and religion, it is easily overlooked the religious circuit and its construction that forms the concept of suicide among the religious laymen. It is assumed that the belief system of traditional religions prohibits suicide and the laymen accordingly construct a perception or concept of suicide along with this belief system. Various studies on this subject have proved it. However, in order to understand the religious way of constructing the concept of suicide on a personal level, it is necessary to pay attention to the religious environment in which the concepts and emotions of suicide circulate. The laymen do not passively and perfectly accept the finely established suicide concept provided by the doctrine or the theology. Rather, the laymen tend to collect the pieces of concept over the suicide that are drifting in the religious environment of his/her daily routine life and to make an concept of suicide in an incomplete form. We can find the unstable and imperfect traits of such a suicide concept through the experience of suicide survivors who have a religious background. For the suicide survivors with religious beliefs, they resist the formal doctrinal and theological provisions to suicide, or try to understand the notion of suicide in their own contexts. In terms of linguistic expressions and ritual acts relating to suicide, the attentions are differently directed in the public and the private domain among the religious groups. Considering on the high rates of suicide in Korean society, the Korean Catholic Churches are increasingly tolerant over the suicide and accept it in the public sphere. It is unlikely when comparing to the negative attitudes of the suicide in the past. However, such tolerance does not go beyond the doctrinal and ethical judgment that defines suicide as a serious sin. The once-committed lay believer's speech and gestures usually contain the various emotions, such as sadness, grief, anxiety, regretfulness, eagerness, and pain in the private spheres. The language and gestures with these emotions have been activated in the religious circuits of suicide, being extended to the religious apparatus for the person who died of suicide. In case of Protestantism, the institutional organizations, such as the particular denominations and the individual-churchism of the Korean Protestant Churches, and their own interpretations of the Bible have in the private sphere strongly effected on the linguistic expressions and the rituals related to the suicide. The religious-ethical judgment of the suicide is varied how the suicide is interpreted by the theologians and the pastors. And the ritual acts for healing the complex feelings and the psychological wounds of the suicide survivors are not actively explored and adopted yet. It makes harder to approach and heal the protestant followers since they emphasize the innermost belief and the salvation assurance faith.

How to Implement Quality Pediatric Palliative Care Services in South Korea: Lessons from Other Countries (한국 소아청소년 완화의료의 발전 방안 제언: 국외 제공체계의 시사점을 중심으로)

  • Kim, Cho Hee;Kim, Min Sun;Shin, Hee Young;Song, In Gyu;Moon, Yi Ji
    • Journal of Hospice and Palliative Care
    • /
    • v.22 no.3
    • /
    • pp.105-116
    • /
    • 2019
  • Purpose: Pediatric palliative care (PPC) is emphasized as standard care for children with life-limiting conditions to improve the quality of life. In Korea, a government-funded pilot program was launched only in July 2018. Given that, this study examined various PPC delivery models in other countries to refine the PPC model in Korea. Methods: Target countries were selected based on the level of PPC provided there: the United Kingdom, the United States, Japan, and Singapore. Relevant literature, websites, and consultations from specialists were analyzed by the integrative review method. Literature search was conducted in PubMed, Google, and Google Scholar, focusing publications since 1990, and on-site visits were conducted to ensure reliability. Analysis was performed on each country's process to develop its PPC scheme, policy, funding model, target population, delivery system, and quality assurance. Results: In the United Kingdom, community-based free-standing facilities work closely with primary care and exchange advice and referrals with specialized PPC consult teams of children's hospitals. In the United States, hospital-based specialized PPC consult teams set up networks with hospice agencies and home healthcare agencies and provide PPC by designating care coordinators. In Japan, palliative care is provided through several services such as palliative care for cancer patients, home care for technology-dependent patients, other support services for children with disabilities and/or chronic conditions. In Singapore, a home-based PPC association plays a pivotal role in providing PPC by taking advantage of geographic accessibility and cooperating with tertiary hospitals. Conclusion: It is warranted to identify unmet needs and establish an appropriate PPD model to provide need-based individualized care and optimize PPC in South Korea.

The Study on the Effect of Target Volume in DQA based on MLC log file (MLC 로그 파일 기반 DQA에서 타깃 용적에 따른 영향 연구)

  • Shin, Dong Jin;Jung, Dong Min;Cho, Kang Chul;Kim, Ji Hoon;Yoon, Jong Won;Cho, Jeong Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.53-59
    • /
    • 2020
  • Purpose: The purpose of this study is to compare and analyze the difference between the MLC log file-based software (Mobius) and the conventional phantom-ionization chamber (ArcCheck) dose verification method according to the change of target volume. Material and method: Radius 0.25cm, 0.5cm, 1cm, 2cm, 3cm, 4cm, 5cm, 6cm, 7cm, 8cm, 9cm, 10cm with a Sphere-shaped target Twelve plans were created and dose verification using Mobius and ArcCheck was conducted three times each. The irradiated data were compared and analyzed using the point dose error value and the gamma passing rate (3%/3mm) as evaluation indicators. Result: Mobius point dose error values were -9.87% at a radius of 0.25cm and -4.39% at 0.5cm, and the error value was within 3% at the remaining target volume. The gamma passing rate was 95% at a radius of 9cm and 93.9% at 10cm, and a passing rate of more than 95% was shown in the remaining target volume. In ArcCheck, the average error value of the point dose was about 2% in all target volumes. The gamma passing rate also showed a pass rate of 98% or more in all target volumes. Conclusion: For small targets with a radius of 0.5cm or less or a large target with a radius of 9cm or more, considering the uncertainty of DQA based on MLC log files, phantom-ionized DQA is used in complementary ways to include point dose, gamma index, DVH, and target coverage. It is believed that it is desirable to verify the dose delivery through a comprehensive analysis.

Trends in QA/QC of Phytoplankton Data for Marine Ecosystem Monitoring (해양생태계 모니터링을 위한 식물플랑크톤 자료의 정도 관리 동향)

  • YIH, WONHO;PARK, JONG WOO;SEONG, KYEONG AH;PARK, JONG-GYU;YOO, YEONG DU;KIM, HYUNG SEOP
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.26 no.3
    • /
    • pp.220-237
    • /
    • 2021
  • Since the functional importance of marine phytoplankton was firstly advocated from early 1880s massive data on the species composition and abundance were produced by classical microscopic observation and the advanced auto-imaging technologies. Recently, pigment composition resulted from direct chemical analysis of phytoplankton samples or indirect remote sensing could be used for the group-specific quantification, which leads us to more diversified data production methods and for more improved spatiotemporal accessibilities to the target data-gathering points. In quite a few cases of many long-term marine ecosystem monitoring programs the phytoplankton species composition and abundance was included as a basic monitoring item. The phytoplankton data could be utilized as a crucial evidence for the long-term change in phytoplankton community structure and ecological functioning at the monitoring stations. Usability of the phytoplankton data sometimes is restricted by the differences in data producers throughout the whole monitoring period. Methods for sample treatments, analyses, and species identification of the phytoplankton species could be inconsistent among the different data producers and the monitoring years. In-depth study to determine the precise quantitative values of the phytoplankton species composition and abundance might be begun by Victor Hensen in late 1880s. International discussion on the quality assurance of the marine phytoplankton data began in 1969 by the SCOR Working Group 33 of ICSU. Final report of the Working group in 1974 (UNESCO Technical Papers in Marine Science 18) was later revised and published as the UNESCO Monographs on oceanographic methodology 6. The BEQUALM project, the former body of IPI (International Phytoplankton Intercomparison) for marine phytoplankton data QA/QC under ISO standard, was initiated in late 1990. The IPI is promoting international collaboration for all the participating countries to apply the QA/QC standard established from the 20 years long experience and practices. In Korea, however, such a QA/QC standard for marine phytoplankton species composition and abundance data is not well established by law, whereas that for marine chemical data from measurements and analysis has been already set up and managed. The first priority might be to establish a QA/QC standard system for species composition and abundance data of marine phytoplankton, then to be extended to other functional groups at the higher consumer level of marine food webs.

A Study on the Development and usefulness of the x/y Plane and z Axis Resolution Phantom for MDCT Detector (MDCT 검출기의 x/y plane과 z축 분해능 팬텀 개발 및 유용성에 관한 연구)

  • Kim, Yung-Kyoon;Han, Dong-Kyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.1
    • /
    • pp.67-75
    • /
    • 2022
  • The aim of this study is to establish a new QC method that can simultaneously evaluate the resolution of the x/y plane and the z-axis by producing a phantom that can reflect exposure and reconstruction parameter of MDCT system. It was used with Aquilion ONE(Cannon Medical System, Otawara, Japan), and the examination was scanned using of 120 kV, 260 mA, and the D-FOV of 300 mm2. It produced new SSP phantom modules in which two aluminum plates inclined at 45° to a vertical axis and a transverse axis to evaluate high contrast resolution of x/y plane and z axis. And it changed factors such as the algorithm, distance from gantry iso-center. All images were reconstructed in five steps from 0.6 mm to 10.0 mm slice thickness to measure resolution of x/y plane and z-axis. The image data measured FWHM and FWTM using Profile tool of Aquarius iNtusion Edition ver. 4.4.13 P6 software(Terarecon, California, USA), and analysed SPQI and signal intensity by ImageJ program(v1.53n, National Institutes of Health, USA). It decreased by 4.09~11.99%, 4.12~35.52%, and 4.70~37.64% in slice thickness of 2.5 mm, 5.0 mm, and 10.0 mm for evaluating the high contrast resolution of x/y plane according to distance from gantry iso-center. Therefore, the high contrast resolution of the x/y plane decreased when the distance from the iso-center increased or the slice thickness increased. Additionally, the slice thicknesses of 2.5 mm, 5.0 mm, and 10.0 mm with a high algorithm increased 74.83, 15.18 and 81.25%. The FWHM was almost constant on the measured SSP graph for evaluating the accuracy of slice thickness which represents the resolution of x/y plane and z-axis, but it was measured to be higher than the nominal slice thickness set by user. The FWHM and FWTM of z-axis with axial scan mode tended to increase significantly as the distance increased from gantry iso-center than the helical mode. Particularly, the thinner slice thickness that increased error range compare with the nominal slice thickness. The SPQI increased with thick slice thickness, and that was closer to 90% in the helical scan than the axial scan. In conclusion, by producing a phantom suitable for MDCT detectors and capable of quantitative resolution evaluation, it can be used as a specific method in the management of research quality and management of outdated equipment. Thus, it is expected to contribute greatly to the discrimination of lesions in the field of CT imaging.

Comparative and Feasibility Evaluation of Detection Ability of Relative Dosimeters using CsPbI2Br and CsPbIBr2 Materials in Brachytherapy QA (근접방사선치료 QA에서 CsPbI2Br과 CsPbIBr2를 이용한 상대 선량계들의 검출 능력 비교 및 적용가능성 평가)

  • Seung-Woo Yang;Sung-Kwang Park
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.433-440
    • /
    • 2023
  • High dose rate brachytherapy is a cancer treatment that intensively irradiates radiation to tumors by inserting isotopes with high dose rates into the body. For such a treatment, it is necessary to deliver an accurate dose to the tumor tissue through an accurate treatment plan while delivering only a minimum dose to the normal tissue. Therefore, it is very important to check the location accuracy of the source through accurate Quality Assurance (QA) in clinical practice. However, since the source position is determined using a ruler, automatic radiographer, video monitor, etc. in clinical practice, it yields inaccurate results. In this study, a semiconductor dosimeter using CsPbI2Br and CsPbIBr2 was fabricated. And, in order to analyze whether it is more suitable for the relative QA dosimeter for brachytherapy device among the two materials, the radiation detection ability of each was compared and evaluated. In order to evaluate the radiation detection ability in brachytherapy, the reproducibility and linearity of the two materials were evaluated in 192IR. In the reproducibility evaluation, CsPbI2Br presented a Relative Standard Deviatio(RSD) of 0.98% and CsPbIBr2 presented an RSD of 3.45%. In the linearity evaluation, the coefficient of determination (R2) of CsPbI2Br was presented as 0.9998, and the R2 of CsPbIBr2 was presented as 0.9994. As a result of the evaluation, it was found that CsPbI2Br was more stable in radiation detection while satisfying the evaluation criteria in the dosimeter manufactured in this experiment. Therefore, CsPbI2Br material is suitable for application as a relative dosimeter for radiation detection in brachytherapy devices.

Exploration of the Multiple Structure of Relational Self and Construct Validation among Korean Adults (한국남녀의 관계적 자아의 특성: 다원적 구성요인 탐색 및 타당성 분석)

  • Ji Kyung Kim;Myoung So Kim
    • Korean Journal of Culture and Social Issue
    • /
    • v.9 no.2
    • /
    • pp.41-59
    • /
    • 2003
  • The present study was conducted to (1) explore the perceptions of Korean men and women about what is an important relationship for them and how do each gender group construe relational self, and (2) develop the scale to assess the factors of relational self and verify construct validity of the scale. 40 college students and 60 adults participated in survey and FGI (Focused Group Interview) respectively, and content analysis of their responses yielded 2 categories with 39 characteristics of relational self. The one category was named 'instrumentality' which was important to men and the other was named 'expressivity' which was important to women. The list of 39 items was administered to a nationwide sample of 1503 Korean adults to assess their construal of relational self through the 6-point Likert scale. Principal axis factor analysis showed that the two categories were unidimensional with high reliability. As a result of factor analysis on each category, a total of 9 factors were extracted. Specifically, the instrumentality consisted of factors such as utilitarianism, independence, initiativeness, self-assurance, and competence. And the factors of expressivity were empathy, passiveness, dependency, consideration. The tests of mean difference revealed that men had higher scores in most of the instrumental factors, while women had higher scores in most of the expressive factors. But there was no sex difference in the interdependent self-construal scale(Cross, 2000) which has been frequently used for measuring relational self. This is related to the Korean's collective cultural characteristics, and it was concluded that the relationship with others is very important to both Korean men and women, but the meaning and expectation of the relationship as well as the method for its preservation are different to each sex group. In addition, the correlation analyses indicated that the feminity score was positively correlated with the expressiveness while the masculinity score was positively correlated with instrumentality. This result implicated the differences of relational self among Korean people were related to the socialization process of each sex, i.e., sex role identity. Finally, limitations of this study and the directions for future research were discussed.

  • PDF