• Title/Summary/Keyword: Assessment Center Method

Search Result 966, Processing Time 0.022 seconds

2D Single-legged Dynamic Knee Valgus assessments Methods: Evaluating Risk Factor for Internal Derangement of the Knee; Literature Review

  • Hyun Lee;Jihye Jung;Seungwon Lee
    • Physical Therapy Rehabilitation Science
    • /
    • v.13 no.2
    • /
    • pp.240-249
    • /
    • 2024
  • Objective: The objective of this study is to evaluate various research that have examined dynamic knee valgus and to pinpoint a straightforward, clinically practical 2D assessment method for dynamic knee valgus that is user-friendly. Design: A literature review Methods: This literature review was conducted in Pubmed, MEDLINE® and Google Scholar with the following key words: Knee valgus angle, Knee valgus evaluation, Knee valgus assessment, Dynamic knee valgus. After removing duplicate studies, 53 articles were initially chosen using this method, with 17 studies ultimately meeting the selection criteria. Results: Based on the comprehensive review of various studies, the Single Leg Squat (SLS) was identified as the most popular test method, followed by the Single Leg Landing (SLL) as the next most common test method. The Frontal Plane Projection Angle (FPPA) method was the most representative method for measuring dynamic knee valgus (DKV) during these tests. SLS was found in a total of 10 studies, while SLL was found in 7 studies. Conclusions: The most commonly proposed test for assessing DKV is measuring the SLS using the FPPA method. However, when applied to individuals without knee pathology, the discriminative power of this method may be limited. This suggests the need for further research to explore alternative methods for assessing DKV in this population.

Reliability Allocation for KTX Door System (KTX 승강문 시스템의 신뢰도 배분)

  • Jang, Mu-Seong;Choi, Byung Oh;Lee, Jeong Hun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.10
    • /
    • pp.1179-1184
    • /
    • 2014
  • Reliability allocation is generally used during the early stage of system development to apportion the system reliability target to its individual modules. This paper presents a comprehensive method for performing the reliability allocation of KTX door systems. Nine criteria for reliability allocation include failure criticality, operating time, risk, complexity, failure rate, maintenance, manufacturing technology, working condition, and reliability cost. For satisfying the system reliability target, the allocated $B_{10}$ lives of four modules are provided.

Post-earthquake Assessment of Mission-Gothic Undercrossing

  • Lou, K.Y.;Ger, J.F.;Yang, R.J.;Cheng, F.Y.
    • Computational Structural Engineering : An International Journal
    • /
    • v.1 no.1
    • /
    • pp.1-9
    • /
    • 2001
  • Collapse behavior of Mission-Gothic Undercrossing under Northridge earthquake is studied by performing nonlinear time-history analysis and three-dimensional nonlinear finite element method for flared columns. Bridge structural model is characterized as three-dimensional with consideration of columns, superstructures, and abutment conditions. Three components of ground motion, corresponding to bridge's longitudinal, transverse, and vertical direction and their combinations are used to investigate bridge collapse. Studies indicate that bridge collapse is dominantly caused by transverse ground motion and the consideration of three-dimensional ground motion leads to a more accurate assessment. Failure mechanism of flared columns is analyzed applying nonlinear finite element method. Reduction of column capacity is observed due to orientation of flare. Further investigation demonstrates that the effects of flare play an important role in predicting of bridge failure mechanism. Suggestions are offered to improve the performance of bridges during severe earthquake.

  • PDF

Statistical Approach to Noisy Band Removal for Enhancement of HIRIS Image Classification

  • Huan, Nguyen Van;Kim, Hak-Il
    • Proceedings of the KSRS Conference
    • /
    • 2008.03a
    • /
    • pp.195-200
    • /
    • 2008
  • The accuracy of classifying pixels in HIRIS images is usually degraded by noisy bands since noisy bands may deform the typical shape of spectral reflectance. Proposed in this paper is a statistical method for noisy band removal which mainly makes use of the correlation coefficients between bands. Considering each band as a random variable, the correlation coefficient measures the strength and direction of a linear relationship between two random variables. While the correlation between two signal bands is high, existence of a noisy band will produce a low correlation due to ill-correlativeness and undirectedness. The application of the correlation coefficient as a measure for detecting noisy bands is under a two-pass screening scheme. This method is independent of the prior knowledge of the sensor or the cause resulted in the noise. The classification in this experiment uses the unsupervised k-nearest neighbor algorithm in accordance with the well-accepted Euclidean distance measure and the spectral angle mapper measure. This paper also proposes a hierarchical combination of these measures for spectral matching. Finally, a separability assessment based on the between-class and within-class scatter matrices is followed to evaluate the performance.

  • PDF

Factors Influencing Falls in Inpatients (입원환자의 낙상 경험에 영향을 미치는 요인)

  • Sung, Young-Hee;Kwon, In-Gak;Kim, Kyung-Hee
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.13 no.2
    • /
    • pp.200-207
    • /
    • 2006
  • Purpose: This study was done to identify factors influencing falls in inpatients. A comprehensive analysis of individual, disease, and environment related factors and an assessment of being in a risk factor group were included in the data. Method: The medical records of 325 inpatients were reviewed. Data were collected from January to July 2003. Frequencies, 1-test and $X^2-test$ were used to analyze the data and the SPSS program was used. Results: Individual-related factors for inpatients falls were age, drinking and weakness. Disease-related factors for inpatients falls were diagnostic department, admission from ER or OPD, admission by wheelchair or orther method and activity status. Environment-related factors for inpatient falls were re-education and side-rails. Assessment of the risk factor group related factors were age, history of falls, body balance, depression, communication, medication, chronic disease, urinary condition and total score for risk factors. Conclusion: Experienceing a fall among Korean inpatients was associated not only with individual factors, but also with disease and environmental factors. The findings of this study suggest that broad intervention programs should be provided to prevent inpatient falls.

  • PDF

Environmental Impacts Assessment of ITO (Indium Tin Oxide) Using Material Life Cycle Assessment (물질전과정평가(MLCA)를 통한 투명전극 ITO (Indium Tin Oxide)의 환경성 평가)

  • Lee, Soo-Sun;Lee, Na-Ri;Kim, Kyeong-Il;Hong, Tae-Whan
    • Clean Technology
    • /
    • v.18 no.1
    • /
    • pp.69-75
    • /
    • 2012
  • In this study, we executed an environmental impact assessment about recycling of ITO (Indium Tin Oxide), used for touch panel. ITO is mainly used to make transparent conductive coatings for touch and flat screen LCD (Liquid Crystal Display), ELD (Emitting Light Device), PDP (Plasma Display Panel). This demand is increasing little by little. but form current status, ITO is discarded than recycling. It is important to recycling ITO for national strategies about resource conservation, and reduce environmental burden. Also Landfill or incineration of ITO cloud be harmful to the human health in the long-term. Material Life Cycle Assessment method (MLCA) was conducted for comparison landfill and recycling of ITO. MLCA would provide more information for environmental issues and potential environmental impacts of ITO. The study includes two scenarios, the basic scenario is recycling of ITO (10, 20, 30%) and the other scenario is landfill of ITO. In addition, amount of carbon dioxide and energy were calculated.

A Preliminary Study on the Preference Assessment on Individuals with Specific Display Location in Screen based on Electroencephalogram and Emotional Assessment (뇌파와 감성평가 기반의 스크린 상 특정 디스플레이 위치 선호도 평가에 관한 기초연구)

  • Wang, ChangWon;Min, Se Dong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.7
    • /
    • pp.968-975
    • /
    • 2014
  • This paper proposed a evaluation method for individual's subjective preferred location using EEG and emotional assessment. Visual stimulus were sequentially presented a total six points(the top and the bottom of the left, the top and the bottom of the center and the top and the bottom of the right on the screen). EEG were measured from twenty subjects according to each six points. At the same time, we were executed evaluation of subjects preferred location from emotional assessment. Alpha and beta wave were measured in Fp1, Fp2, F7 and F8 location, followed by ten to twenty electrode system. Correlations and variations of alpha and beta wave from each channel were calculated and analyzed. Because of the number of subjects population under 30, we used Speareman test for a correlation analysis between alpha and beta wave. Also, emotional assessments which compose of visual sense harmony, visual sense stability, stability of position and the visibility were performed and were analyzed by average and frequency. After visual stimulus, emotional assessments were performed. From the variance analysis of EEG, beta wave from F7 was appeared statistically significant as significance probability of 0.006. Also, between alpha wave and beta wave appeared a negative correlation(r=-0.190). From the post-hoc test of F7 beta wave, location 1, 5 and 6 appeared to difference statistically significant. Emotional assessment result according to six positions showed 0.00 significance probability. Thus, location and emotional assessment appeared to influence on each other. From the average and frequency analysis of emotional assessment, location 2 showed obtained of best emotional assessment score and appeared lower beta wave than other locations. Finally, most subjects showed a preference for location 2. Through obtained results in this paper, will be helpful to about human emotional assessment and EEG research.

Comparisons of obesity assessments in over-weight elementary students using anthropometry, BIA, CT and DEXA

  • Yu, Ok-Kyeong;Rhee, Yang-Keun;Park, Tae-Sun;Cha, Youn-Soo
    • Nutrition Research and Practice
    • /
    • v.4 no.2
    • /
    • pp.128-135
    • /
    • 2010
  • Obesity was characterized in Korean elementary students using different obesity assessment tests on 103 overweight elementary students from three schools of Jeonbuk Province. The body mass index (BMI) and obesity index (OI) were compared, and the data using DEXA and CT were compared with the data using BIA and a tape measure. The results of this study are as follows: first, 27 students who were classified as obese by OI were classified as overweight by BMI, and 3 students who were classified as standard weight by BMI were classified as overweight by OI. Secondly, by DEXA and BIA measurements, there was 1.51% difference in body fat percentage (boys 1.66%, girls 1.17%) and the difference in body fat mass between boys and girls was 0.77 kg (boys 0.85 kg, girls 0.59 kg), but those differences in body fat percentage and mass were not statistically significant. Thirdly, the average total abdominal fat (TAF) measured by CT scans of obese children was more significantly related with subcutaneous fat (r = 0.983, P < 0.01) than visceral fat (r = 0.640, P < 0.01). Also, TAF were highest significant with waist circumference by a tape measure (r = 0.744, P < 0.01). In summary, as there are some differences of assessment results between two obesity test methods (BMI, OI), we need more definite standards to determine the degree of obesity. The BIA seems to be the most simple and effective way to measure body fat mass, whereas waist/hip ratio (WHR) using a tape measurer is considered to be the most effective method for assessing abdominal fat in elementary students.

A Study on the Life Characteristic of an Automotive Water-pump Bearing Using the Accelerated Test Method (가속시험법을 활용한 자동차용 워터펌프 베어링의 수명특성에 관한 연구)

  • Yang, Hui Sun;Shin, Jung Hun;Park, Jong Won;Sung, Baek Ju
    • Tribology and Lubricants
    • /
    • v.31 no.2
    • /
    • pp.35-41
    • /
    • 2015
  • A water-pump located in the cooling area of a car circulates cooling water. A particular bearing element, known as a water-pump bearing, installed in the rotating part carries the entire load. The failure of this water-pump bearing has a direct impact on the failure of the automobile engine, and so securing its reliability is crucial. Several researchers have examined the design principles of the water-pump bearing, but there are no reports on the life characteristic of the bearing yet. Herein, we report the construction of test equipment to reproduce the spalling of the roller contact, which is the main failure mode of the chosen water-pump bearing. We chose the radial load as an accelerated stress factor and validated the failure mode by monitoring the surface defects. We conducted the accelerated life test after determining the accelerated stress level through a combination of finite element analysis and a preliminary test. In the life tests, we used an accelerometer to perform failure diagnosis. In the last stage of this study, we present a statistical reliability analysis. Thus, we fully estimated the shape parameter of the water-pump bearing, accelerating level on the load , and the lifetime (MTTF and B10 life) under real use conditions, and finally proposed an interval estimation value considering the uncertainty of the estimated value.

Physical protection system vulnerability assessment of a small nuclear research reactor due to TNT-shaped charge impact on its reinforced concrete wall

  • Moo, Jee Hoon;Chirayath, Sunil S.;Cho, Sung Gook
    • Nuclear Engineering and Technology
    • /
    • v.54 no.6
    • /
    • pp.2135-2146
    • /
    • 2022
  • A nuclear energy facility is one of the most critical facilities to be safely protected during and after operation because the physical destruction of its barriers by an external attack could release radioactivity into the environment and can cause harmful effects. The barrier walls of nuclear energy facilities should be sufficiently robust to protect essential facilities from external attack or sabotage. Physical protection system (PPS) vulnerability assessment of a typical small nuclear research reactor was carried out by simulating an external attack with a tri-nitro toluene (TNT) shaped charge and results are presented. The reinforced concrete (RC) barrier wall of the research reactor located at a distance of 50 m from a TNT-shaped charge was the target of external attack. For the purpose of the impact assessment of the RC barrier wall, a finite element method (FEM) is utilized to simulate the destruction condition. The study results showed that a hole-size of diameter 342 mm at the front side and 364 mm at the back side was created on the RC barrier wall as a result of a 143.35 kg TNT-shaped charge. This aperture would be large enough to let at least one person can pass through at a time. For the purpose of the PPS vulnerability assessment, an Estimate of Adversary Sequence Interruption (EASI) model was used, which enabled the determination of most vulnerable path to the target with a probability of interruption equal to 0.43. The study showed that the RC barrier wall is vulnerable to a TNT-shaped charge impact, which could in turn reduce the effectiveness of the PPS.