• Title/Summary/Keyword: Assay sensitivity

Search Result 752, Processing Time 0.022 seconds

Evaluation of In vitro and In vivo Screening Methods for Estrogenic Activity of Endocrine Disruptors (내분비계 장애물질의 에스트로겐 활성에 대한 In vitro 및 In vivo 검색시험법)

  • 김형식;한순영;한상국;신재호;문현주;김소희;박기숙;김규봉;이이다
    • Toxicological Research
    • /
    • v.16 no.2
    • /
    • pp.109-116
    • /
    • 2000
  • The purposes of our study were to optimize the conditions of the screening and testing methods for endocrine disruptors, to characterize these assays using several compounds with well-defined endocrine activity, and to compare the sensitivity between these assays currently undergoing validation. Two in vitro test systems, MCF-7 cells proliferation (E-screen assay) and competitive binding to estrogen receptors (ER) were selected to evaluate the estrogenic effects. 17$\beta$-Estradiol (E2) and diethylstilbestrol (DES) were used as a positive control in vitro test. Also, E2 and ethinyl estradiol (EE) were used as a positive control in vivo uterotrophic assay. In in vitro test, E2 and DES showed a strong estrogenic response at concentration of 1.0 nM. In uterotrophic assay, E2 (0.3 $\mu\textrm{g}$/kg) and EE (0.3 $\mu\textrm{g}$/kg) produced a significant increase in uterus and vagina weight in both immature and ovariectomized rats. Although we did not com-pared the specificity between in vivo and in vitro assays, these assay systems may serve as a good tool for endocrine disruptors screening methods. Our data indicate that these assay systems exhibit some difference in their sensitivity to the same estrogenic compounds. Therefore, as a first rapid screening assay for estrogenic activity qf unknown chemicals, at least two assay systems should probably be carried out with a view of high sensitivity and standardization conditions. Also, a careful validation tests are necessary to obtain a reasonable degree of reproducibility.

  • PDF

The Usefulness of Whole-blood Interferon-gamma Release Assay for the Diagnosis of Extra-pulmonary Tuberculosis (폐외 결핵에서 전혈 인터페론 감마 측정법의 진단적 유용성)

  • Lee, Hye-Min;Cho, Sung Gun;Kang, Hyung Koo;Park, Sung Woon;Lee, Byung Ook;Lee, Jae Hee;Jeon, Eun Ju;Choi, Jae Chol
    • Tuberculosis and Respiratory Diseases
    • /
    • v.67 no.4
    • /
    • pp.331-337
    • /
    • 2009
  • Background: The whole-blood interferon-gamma release assay (QuantiFERON-TB Gold [QFT-G]: Cellestis, Carnegie, Victoria, Australia) has been studied primarily for the use of diagnosing active pulmonary tuberculosis (TB) or latent TB. In the present study, the usefulness of QFT-G was evaluated for the diagnosis of extra-pulmonary tuberculosis (EP-TB). Methods: From June 2006 to February 2009, we evaluated the usefulness of QFT-G in patients (n=65) suspected with EP-TB, retrospectively. The diagnostic sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the QFT-G assay were analyzed. Results: EP-TB was diagnosed in 33 (51%) participants. The overall sensitivity, specificity, PPV, and NPV of the QFT-G assay for EP-TB were 78%, 79%, 81%, and 77%, respectively. Of the 33 with EP-TB, 14 (42%) were diagnosed with TB pleurisy, 7 (21%) with TB lymphadenitis, 7 (21%) with intestinal TB, and 5 (15%) with EP-TB in other sites. In subgroup analyses according by site of infection, the QFT-G showed 86% sensitivity, 64% specificity, and 78% NPV in TB pleurisy. On the other hand, the sensitivity, specificity, and NPV of the assay were 71%, 83% and 71%, respectively in TB lymphadenitis, and 86%, 100% and 88%, respectively in intestinal TB. Among the patients with suspected alternative site EP-TB, the sensitivity, specificity, and NPV of the assay were 50%, 80% and 67%, respectively. Conclusion: The QFT-G assay showed moderate diagnostic accuracy in EP-TB. However, negative QFT-G assay does not exclude EP-TB because of the low NPV of this assay.

A Comparative Study of the Detectable Methods of Residual Antibiotics in Milk (우유중 잔류 항생물질 분서방법에 관한 비교연구)

  • 백선영;김형일;박건상;김소희;권경란
    • Journal of Food Hygiene and Safety
    • /
    • v.11 no.2
    • /
    • pp.129-132
    • /
    • 1996
  • Recently, as concern about the residual antibiotics in milk increase, the detection methods of residual antibiotics used extensevely at the present time were investigated and compared to their properties and the detection limits of variable antibiotics. At first, comparactive tests of the detectable sensitivity of 4 test organisms, B. cereus, B. subtilis, M.luteus, B.stearothermophilus C-953, were performed by disc assay. As a result, B.stearothermophilus was the most sensitive strain of all other strains and showe the detect limit of 5-50 ppb for penlicillins (PCs). And also, B.subitilis was showed the more effective detection limit, 200-400 ppb, for aminoglycosides (AGs) and M.luteus was showed predominant sensitivity , 50-500 ppb for macrolides(MLs) and B.cereus was the most sensitive strain for tetracyclines (TCs) and showed the detection limit of 100-400 ppb. Therefore, each test strains were showed a different sensitivity in the detection of the different antibiotic families. When the detection limit of disc assay and other methods were compared, TTCmethod was less sensitive than other methods showing 5-50 ppb detectable lebel for PCs. Also, for the detection of other antibiotic families TTC method was showed the worst sensitivity and Delvo and Charm Farm tests were similar to the detectable properties of AGs and MLs. Although disc assay was showed the similar detection limit for PCs with Delvo and Charm Farm, it was more widely effective for the detection of kanamycin, erythromycin, chlortetracycline, doxycycline, verginiamycin and so on than Delvo or Charm Farm. CharmII test was showed the best sensitivity for the most of antibiotics except neomycin and gentamycin. But it was necessary that different tests must be performed to each antibiotic family and so it was regarded that the effectiveness of that method was low.

  • PDF

Development of diagnostic method for human Astrovirus with rapid, specific and high sensitivity using loop-mediated isothermal amplification method

  • Lee, Jin-Young;Rho, Jae Young
    • Korean Journal of Agricultural Science
    • /
    • v.47 no.1
    • /
    • pp.173-182
    • /
    • 2020
  • Human Astrovirus (HuAstV), known as a waterborne virus, is a group IV positive-sense single-stranded RNA that belongs to Astroviridae. The first outbreak of HuAstV was reported in England in 1975. HuAstV can exist not only among clinical patients but also in various water environments, such as water for agriculture and vegetables. For diagnosis of HuAstV from water samples, a polymerase chain reaction (PCR) system has been developed. However, the PCR-based diagnostic method has problems in field application, such as reaction time, sensitivity and specificity. For this reason, in this study we developed the loop-mediated isothermal amplification assay (LAMP) system, aimed specifically at HuAstV. Three prepared LAMP primer sets were tested by specificity, non-specificity and sensitivity; one LAMP primer set was selected with optimum reaction temperature. The developed LAMP primer set reaction conditions were confirmed at 62℃, and detection sensitivity was 1 fg/μL. In addition, restriction enzyme HaeIII (GG/CC) was introduced to confirm that the LAMP reaction was positive. As a result, selected LAMP primer set was 100 - 1000 times more specific, rapid, and sensitive than conventional-nested PCR methods. For verification of the developed LAMP assay, twenty samples of cDNA from groundwater samples were tested. We expect that the developed LAMP assay will be used to diagnose HuAstV from various samples.

Evaluation of Rapid Immunochromatographic Assay Kit for HBsAg-Screening Using Whole Blood

  • Shin, Hyeong-Soon;Heo, Tae-Ryeon
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.5 no.5
    • /
    • pp.362-365
    • /
    • 2000
  • A rapid immunochromatographic assay kit using whole blood to screen hepatitis B surface antigen was developed and evaluated by using sera from 240 patients. The reference diagnosis was based on the results obtained with GENEDIA Anti-HBs Rapid kit which is very similar to the above kit except for the use of serum. The test demonstrated a good correlation with the reference immunochromatographic assay kit, that is, the sensitivity and the specificity of the kit was 100%, respectively. The rapid test kit using whole blood should be more convenient and useful for the diagnosis of hepatitis B virus because the kit does not need machines and time to prepare serum. In addition, this kit is safe from inadvertent infection during sample treatment because the blood is sterilized with hydrogen peroxide, eliminates the procedure required to prepare serum and reduces the possibility of exposure to infectious agents.

  • PDF

Comparison of Multiplex Latex Bead Flow Cytometric Analysis and Quellung Analysis in Serotyping Pneumococci (Multiplex Latex Bead 유세포 분석기 기법과 Quellung 반응을 이용한 폐구균 혈청형 분석 비교)

  • Choi, Kyong Min;Yeon, Soo In;Kim, Eun Sook;Shin, Jeon Soo;Yong, Dong Eun;Lee, Kyoung Won;Kim, Dong Soo
    • Pediatric Infection and Vaccine
    • /
    • v.13 no.2
    • /
    • pp.99-105
    • /
    • 2006
  • Purpose : The serotyping results of the Quellung reaction was compared with the newly developed multiplex latex assay and the sensitivity of the Quellung reaction was compared. Methods : We checked the serotypes of 35 samples obtained from patients treated at Yonsei University Medical Center using the multiplex latex bead method and compared the results with the serotypes previously obtained via the Quellung reaction. Results : A decrease in the mean fluorescence was detected in the samples tested with the multiplex assay. Seventeen samples out of the 27 samples agreed to the results of the Quellung assay. We were only able to confirm the concordance of 11 serotypes out of 14 serotypes available. Conclusion : The Quellung reaction is time consuming procedure and prone to errors even with expertise in the procedure, and other alternate methods in serotyping have been investigated to overcome these problems. The newly developed multiplex latex bead assay can test more samples at the same time and has a higher degree of sensitivity. A large scale trial is required to test the sensitivity of the new assay across various serotypes along with efforts to increase the sensitivity of the Quellung assay. The preliminary data suggests that this method may be widely used.

  • PDF

Detection and Quantification of Toxin-Producing Microcystis aeruginosa Strain in Water by NanoGene Assay

  • Lee, Eun-Hee;Cho, Kyung-Suk;Son, Ahjeong
    • Journal of Microbiology and Biotechnology
    • /
    • v.27 no.4
    • /
    • pp.808-815
    • /
    • 2017
  • We demonstrated the quantitative detection of a toxin-producing Microcystis aeruginosa (M. aeruginosa) strain with the laboratory protocol of the NanoGene assay. The NanoGene assay was selected because its laboratory protocol is in the process of being transplanted into a portable system. The mcyD gene of M. aeruginosa was targeted and, as expected, its corresponding fluorescence signal was linearly proportional to the mcyD gene copy number. The sensitivity of the NanoGene assay for this purpose was validated using both dsDNA mcyD gene amplicons and genomic DNAs (gDNA). The limit of detection was determined to be 38 mcyD gene copies per reaction and 9 algal cells/ml water. The specificity of the assay was also demonstrated by the addition of gDNA extracted from environmental algae into the hybridization reaction. Detection of M. aeruginosa was performed in the environmental samples with environmentally relevant sensitivity (${\sim}10^5$ algal cells/ml) and specificity. As expected, M. aeruginosa were not detected in nonspecific environmental algal gDNA over the range of $2{\times}10^0$ to $2{\times}10^7$ algal cells/ml.

Development of PCR-microplate Hybridization Assay for Detection of Mycobacterium tuberculosis

  • Lee, In-Soo;Cho, Een-Jin;Cho, Sang-Nae;Kim, Tae-Ue;Lee, Hye-Young
    • Biomedical Science Letters
    • /
    • v.15 no.4
    • /
    • pp.295-300
    • /
    • 2009
  • Tuberculosis caused by Mycobacterium tuberculosis (MTB) still remains to be the most dreadful infectious disease affecting almost every country. In the present study, we developed a simple and rapid but accurate and sensitive assay method for detecting MTB using microplate hybridization assay. For this, a selective region of the rpoB gene was used to design PCR primers, and MTB and Mycobacterium genus-specific probe molecules. The specificity of the assay was confirmed using fifteen different mycobacterial reference strains and twelve different non-mycobacterial reference strains, and the sensitivity was determined to be 100 fg using genomic DNA of MTB reference strain, H37Rv. Subsequently, a total of 62 sputum samples with diverse smear scores and culture positive results were used to evaluate the kit performance. In brief, the specificity and the sensitivity of the assay were 100% and 98.4%, respectively.

  • PDF

Detection of Acute Toxoplasmosis in Pigs Using Loop-Mediated Isothermal Amplification and Quantitative PCR

  • Wang, Yanhua;Wang, Guangxiang;Zhang, Delin;Yin, Hong;Wang, Meng
    • Parasites, Hosts and Diseases
    • /
    • v.51 no.5
    • /
    • pp.573-577
    • /
    • 2013
  • A loop-mediated isothermal amplification (LAMP) assay allows rapid diagnosis of Toxoplasma gondii infection. In the present study, the LAMP assay was evaluated using blood from both naturally and experimentally infected pigs. The sensitivity of the LAMP assay was compared with that of Q-PCR. Both assays detected T. gondii in the blood of experimentally infected pigs, with 100% agreement. In infected blood samples, the parasite was detected as early as 2 days post-infection and reached a peak in 3-5 days. In 216 field serum samples, the detection rates of LAMP and Q-PCR assays were 6.9% and 7.8%, respectively. This result indicates that the sensitivity of the LAMP assay was slightly lower than that of the Q-PCR assay. However, the LAMP may be an attractive diagnostic method in conditions where sophisticated and expensive equipment is unavailable. This assay could be a powerful supplement to current diagnostic methods.

Comparison of the Sensitivity of Type I Signal Peptidase Assays

  • Sung, Meesook
    • Journal of Life Science
    • /
    • v.11 no.2
    • /
    • pp.94-98
    • /
    • 2001
  • Type I signal peptidase cleaves the signal sequence from the amino terminus of membrane and secreted proteins afters these protein insert across the membrane. This enzyme serves as a potential target for the development of novel antibacterial agents due to its unique physiological and biochemical properties. Despite considerable research, the signal peptidase assay still remains improvement to provide further understanding of the mechanism and high-throughput inhibitor screening of this enzyme. In this paper, three known signal peptidase assays are tested with an E. coli D276A mutant signal peptidase to distinguish the sensitivity of each assays. In vitro assay using the procoat synthesized by in vitro transcription translation shows that the D276A signal peptidase I was inactive while in vivo processing of pro-OmpA expressed in the temperature-sensitive E. coli strain IT41 as well as in vitro assay using pro-OmpA nuclease A substrate show that D276A signal peptidase I has activity like wild-type signal peptidase. These results suggest that in vitro assay using the pro-OmpA nuclease A and in vivo pro-OmpA processing assay are more sensitive monitors than in vitro assay using the pro-coat. In conculsion, caution should be used when interpreting the in vitro results using the procoat.

  • PDF