• 제목/요약/키워드: Aspherical

검색결과 188건 처리시간 0.026초

A Swing-Arm On-Machine Inspection Method for Profile Measurement of Large Optical Surface in Lapping Process

  • Sung In Kyoung;Oh Chang Jin;Lee Eung Suk;Kim Ock Hyun
    • Journal of Mechanical Science and Technology
    • /
    • 제19권8호
    • /
    • pp.1576-1581
    • /
    • 2005
  • Generally, the optical components are fabricated by grinding, lapping, and polishing. And, those processes take long time to obtain such a high surface quality. Therefore, in the case of large optical component, the on-machine inspection (OMI) is essential. Because, the work piece is fragile and difficult to set up for fabricating and measuring. This paper is concerned about a swing-arm method for measuring surface profile of large optical concave mirror. The measuring accuracy and uncertainty for suggested method are studied. The experimental results show that this method is useful specially in lapping process with the accuracy of $3\~5\;{\mu}m$. Those inspection data are provided for correcting the residual figuring error in lapping or polishing processes.

비구면 반사경 표면의 형상오차 측정법 비교 (Comparison Surface Error Measurements of Aspherical Mirror)

  • An, Jongho;Pak, Soojong;Kim, Sanghyuk;Park, Woojin;Jeong, Byeongjoon
    • 천문학회보
    • /
    • 제41권1호
    • /
    • pp.73.3-74
    • /
    • 2016
  • 본 연구에서는 비구면 반사경의 형상오차를 3가지 방법으로 측정, 비교하였다. 실험에 사용한 포물면 반사경의 구경은 108 mm, 유효초점거리는 444.5 mm 이다. 첫 번째로 접촉식 형상측정방식인 FTS(Form TalySurf)를 이용하여 표면 거칠기와 반사경의 최적 곡률 반경(BestFitt Radius) 값을 측정하였다. 두 번째로는 비접촉식 형상측정방식인 UA3P(Ultrahigh Accurate 3-D Profilometer)를 이용하여 반사경의 형상 정밀도를 측정하였다. UA3P를 이용할 경우 반사경의 전체 형상을 측정할 수 있다. 세번째로 Shark-Hartmann 센서를 이용한 광학측정방법으로 반사경의 형상 정밀도를 측정하였다. 측정에 필요한 레이저 광학계는 레이저, 콜리메이터, 핀홀, 카메라 렌즈 및 비구면 광학계를 이용하여 설계하였다. 본 연구에서 도출한 각 측정 방법의 신뢰도를 바탕으로 간섭계 사용에 제약이 있는 자유형상곡면의 반사경 표면의 형상오차 측정에 적용할 계획이다.

  • PDF

하트만 방법에 의한 광학면의 기상측정 (On-Machine Measurement of an Optical Surface by Hartmann Test)

  • 김용관;오창진;이응석;김옥현
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2002년도 추계학술대회 논문집
    • /
    • pp.474-480
    • /
    • 2002
  • Aspheric optical lenses and mirrors are widely used in recent. It is more difficult to manufacture and measure the aspherical optics compared to conventional spherical ones. The interferometric optical test is common for the measurement of spherical optical surface. But the application of the interferometry to the measurement of aspheric surface is difficult because it needs a precise null corrector and very careful environmental conditions such as keeping constant temperature, humidity, atmospheric pressure and vibrations. To enhance productivity of optics manufacturing on-machine measurement and correction has been developed in this study. For practical applications, robustness of the measurement method to environments is more important. For the purpose an optical OMM(On-Machine Measurement) system has been developed using Shack-Hartmann test which has robustness to the environment. The wavefront has been reconstructed from the measured data using the primary aberration polynomial function by least square fitting. The measured result of the developed only system gives the maximum deviation only in 200 nm from the result measured by a commercial Fizeau interferometer Wyko 6000.

  • PDF

Design and Experimental Demonstration of Coaxially Folded All-reflective Imaging System

  • Xiong, Yupeng;Dai, Yifan;Chen, Shanyong;Tie, Guipeng
    • Current Optics and Photonics
    • /
    • 제3권3호
    • /
    • pp.227-235
    • /
    • 2019
  • With slimmer, lighter and all-reflective imaging systems in high demand for consumer and military applications, coaxially folded optical image systems are widely considered because they can extend focal length and reduce track length. Most of these systems consist of multiple surfaces, and these surfaces are machined on one element or grouping processing on two elements. In this paper, we report and first experimentally demonstrate an all-aluminum all-reflective optical system which consists of two optical elements, with two high order aspherical surfaces in each element. The coaxially folded system is designed with Seidel aberration theory and advanced optimization with Zemax. The system is made of all-aluminum material processing by single point diamond turning (SPDT). On this basis, we completed the system integration and performed an imaging experiment. The final system has the advantages of short track length and long focal length and broad application prospects in the micro-unmanned aerial vehicle field.

REMARKS ON GROUP EQUATIONS AND ZERO DIVISORS OF TOPOLOGICAL STRUCTURES

  • Seong-Kun Kim
    • East Asian mathematical journal
    • /
    • 제39권3호
    • /
    • pp.349-354
    • /
    • 2023
  • The motivation in this paper comes from the recent results about Bell inequalities and topological insulators from group theory. Symmetries which are interested in group theory could be mainly used to find material structures. In this point of views, we study group extending by adding one relator which is easily called an equation. So a relative group extension by a adding relator is aspherical if the natural injection is one-to-one and the group ring has no zero divisor. One of concepts of asphericity means that a new group by a adding relator is well extended. Also, we consider that several equations and relative presentations over torsion-free groups are related to zero divisors.

마주보는 대칭렌즈를 가지는 MWIR용 초점거리 24mm의 비구면 결상광학계 설계 (Design of Aspheric Imaging Optical System having 24mm Focal Length for MWIR with Facing Symmetric Lenses)

  • 이상길;김부태;이동희
    • 한국융합학회논문지
    • /
    • 제9권9호
    • /
    • pp.183-189
    • /
    • 2018
  • 본 연구는 마주보는 두 대칭렌즈를 가지는 초점거리 24mm 인 MWIR($3{\sim}5{\mu}m$)용 결상광학계의 설계 개발에 관한 것이다. 광학계는 CodeV를 사용하여 설계하였으며, 사용자의 요구조건을 만족할 수 있는 분해능과 화각을 가지도록 최적화 과정을 진행하였다. 렌즈의 초자는 국내에서 개발된 $3{\mu}m$에서 굴절률 1.7589를 갖는 초자( KCIR035 )를 포함하여 두 종류로 제한하였다. 이렇게 설계되어진 광학계는 같은 모양을 갖는 KCIR035 초자의 2장의 비구면 렌즈와 1장의 Si 초자의 구면 렌즈로 이루어져 있다. 여기서 2장의 비구면 렌즈의 배치는 마주보는 대칭구조를 이루고 있는 것이 특징이다. 그리고 이 광학계는 선폭 20lp/mm에서 MTF값이 0.35 이상인 분해능을 갖게 되었다. 따라서 이 광학계는 pixel의 크기가 $25{\mu}m$$206{\times}156$ 어레이 MWIR 검출소자를 사용하는 열영상 카메라에 적용할 수 있는 성능을 가진 것으로 판단된다.

Ir-RE 코팅 대비 자장여과필터방식을 이용한 비구면 유리 렌즈용 초경합금(WC)표면의 ta-C 박막 코팅 성능 개선 연구 (A Study on the Performance Improvement of ta-C Thin Films Coating on Tungsten Carbide(WC) Surface for Aspherical Glass Lens by FCVA Method Compared with Ir-Re coating)

  • 정경서;김승희
    • 한국산학기술학회논문지
    • /
    • 제20권12호
    • /
    • pp.27-36
    • /
    • 2019
  • 작은 굴절률 및 높은 굴절률을 갖는 저 분산 렌즈에 대한 요구가 증가함에 따라, 높은 내열성 및 내마모성을 갖는 이형성 보호 필름에 대한 필요성이 증가하고 있다. 그러나 광학 산업은 비구면 유리 렌즈 성형에 사용되는 이형보호 필름의 제조 공정 및 품질 표준에 대한 명확한 표준을 아직 확립하지 못했다. 이 기술은 광학 렌즈를 제조하는 각 회사의 노하우로 취급된다. 본 연구에서는 FCVA (Filtered Cathode Vacuum Arc) 기반 ta-C 박막 코팅의 이온에칭, 각 소스 및 필터부의 마그네트론 및 아크 전류, 바이어스 전압의 최적화에 관한 실험을 수행하였다. 그 결과, 코팅성능 측면에서, 이리듐- 레늄 합금 박막 스퍼터링 제품 대비 필름 두께가 약 50% 얇고, 경도는 약 20%, 박막의 접착강도는 약 40 % 개선된 것으로 측정되었다. 본 연구의 박막 코팅 공정 결과는 금형 이형 박막층의 최소 기계적 특성 및 품질 확립을 위한 유리 렌즈의 개발 및 활용에 크게 기여할 것으로 사료된다.

평면-비구면 2×2 fly-eye 렌즈형태의 2차 렌즈를 사용한 고효율의 좁은 배광각을 갖는 MR-16 램프 시리즈 제작 및 성능평가 (Fabrication and Performance Evaluation of MR-16 Lamp Series with Narrow Angular Distribution of Luminous Intensity Using an Aspherical Planar-convex 2×2 Fly-eye Lens Type)

  • 추경덕;류재명;홍춘강;정연홍;조재흥
    • 한국산학기술학회논문지
    • /
    • 제18권8호
    • /
    • pp.25-33
    • /
    • 2017
  • 본 연구에서는 간편하고 빠른 사출성형을 위하여 한쪽이 평면인 비구면 형상을 갖는 단일 fly-eye 렌즈형태의 2차 렌즈를 사용하는 MR-16 램프 시리즈의 설계를 보고하고자 한다. 인테리어 조명용 할로겐 램프를 대체하기 위해 효율이 높고 좁은 배광각을 갖도록 MR-16 램프용 광학계를 설계하여 이를 제작하고 성능을 확인하였다. 광학설계용 소프트웨어는 ORA사의 CODE V와 LightTools를 사용하였다. 그 결과, 제작된 MR-16 램프의 배광각은 $22.4^{\circ}$, $31.1^{\circ}$, $37.3^{\circ}$, $59.9^{\circ}$였으며, 광효율은 각각 76.5 lm/W, 75.2 lm/W, 72.0 lm/W, 77.8 lm/W 이고, 복사 균제도 81%에서 발산각은 $3^{\circ}$, $15^{\circ}$, $22^{\circ}$, $49^{\circ}$이다. 그리고 제작된 MR-16 램프에 확산시트를 2차 렌즈와 LED사이에 확산 시트를 적용하여 황색 띠를 제거한 후의 배광각은 각각 $20.8^{\circ}$, $31.5^{\circ}$, $37.8^{\circ}$, $68.7^{\circ}$로 측정되었다. 실험적으로 2차 렌즈를 같은 렌즈 4개를 붙이는 형식으로 fly-eye 형태로 함으로써 설계 및 제작이 용이하며 배광각과 균일한 조도 분포를 갖는데 있어서 문제가 없다는 것을 알 수 있었다.

조정방식과 경통고정방식에 대한 자동무수차점 널 렌즈 광학계의 측정 정밀도 한계 및 신뢰도 (A Study for the Limitation of Measurement Accuracy and Reliability of Autostigmatic Null lens System by Adjustment and Fixing Process)

  • 이영훈;임천석
    • 한국광학회지
    • /
    • 제16권5호
    • /
    • pp.440-445
    • /
    • 2005
  • 비구면 평가를 위한 자동무수차점 널 렌즈 광학계에서, 널 렌즈간 거리를 정렬의 조정 인자로 사용하는 방식과 널 렌즈간 거리를 경통으로 고정 하는 방식에 대해 측정 정밀도의 한계 및 신뢰도를 연구하였다. 먼저 널 렌즈간 거리를 정렬의 조정 인자로 사용하는 방식에 있어서는, 널 렌즈의 제작오차에 의해 유기되는 전체 널 렌즈 광학계의 파면수차가 보상되는 특성이 나타나고 이로 말미암아 시험 비구면의 모호성(측정오차)이 발생하게 되어 측정의 신뢰도가 저하되는 결과가 초래되었다. 그리고 널 렌즈간 거리를 경통으로 고정하는 방식은, 널 렌즈계의 제작오차에 의해 유기되는 파면수차가 보상 되지 않기 때문에 측정오차가 발생하지 않았다. 즉, 이로부터 널 렌즈 광학계는 측정오차가 제거될 수 있는 경통고정방식으로 구성되어야 함을 알 수 있었다. 또, 본 연구에서는 널 렌즈와 시험 비구면간의 원거리 정렬을 제어하기 위해 시험 비구면 상에 정렬구경이라는 개념을 제안하였고, 정렬구경을 사용한 자동무수차점 방식의 측정 정밀도 한계도 이론적으로 분석하여 보았다.

증강 현실 응용을 위한 비구면 광학계 설계 및 제작 (Design and Fabrication of Aspherical Optical System for Augmented Reality Application)

  • 신창원;함형창;박애진;정희재;이강휘;최치원
    • 한국광학회지
    • /
    • 제34권4호
    • /
    • pp.157-169
    • /
    • 2023
  • 헤드 마운티드 디스플레이(head mounted display, HMD)를 이용한 증강 현실(augmented reality, AR)은 군사, 의료, 제조, 게임 및 교육 등 다양한 분야에서 활용되고 있다. 본 논문에서는 HMD에 가장 필수적인 AR 광학계의 설계 및 제작에 대해 논의한다. HMD용 AR 광학계는 디스플레이의 증강 영상과 현실 세계를 동시에 볼 수 있는 넓은 투명 영역이 필요하다. 이를 위해, AR 광학계를 각각의 특성에 따라 세 부분으로 나누어 설계 및 제작하였다. 그리고 3개의 광학계를 하나의 완전한 AR 광학계로 만들기 위해 필요한 ultra-violet (UV) 접착층의 굴절률을 고려해 설계함으로써 입력 광원이 UV 접착 층을 통과할 때의 광경로 이동(shift) 현상을 최소화하였다. 또한, AR 광학계를 설계할 때 축외 수차를 보정하고 양산에 적합하도록 2개의 비구면을 사용했다. 끝으로 HMD 양산을 위해 두께 11 mm, 대각선 화각(diagonal field of view) 40°, 무게 11.3 g의 비구면 AR 광학계를 설계하고 제작하였다.