• Title/Summary/Keyword: Asbestos-containing materials (ACMs)

Search Result 5, Processing Time 0.019 seconds

A study on the status of asbestos use on ships (선박에서의 석면 사용실태 연구)

  • Park, Seung-Hyun;Chung, Eun-Kyo;Kwon, Ji-Woon;Kim, Kab-Bae;Chung, Kwang-Jae;Yi, Gwang-Yong;Shin, Jung-Ah;Lee, In-Seop;Kang, Seong-Kyu
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.21 no.3
    • /
    • pp.123-127
    • /
    • 2011
  • Objectives: The purpose of this study was to investigate the status of asbestos-containing materials (ACMs) used on ships and to consider measures for preventing worker exposure to asbestos fibers. Methods: A total of 17 ships including 16 ships under repair and a ship under construction at shipyards in Korea were investigated. Bulk samples were collected from suspected ACMs on engine exhaust pipes, boiler steam pipes, generator exhaust pipes, and etc. in ships in order to identify the presence of ACMs. Types and contents of asbestos were determined using polarized light microscopy (PLM). Results: ACMs were found from 14 ships out of 17 ships investigated. Only chrysotile asbestos was found from all samples. ACMs were mainly found from samples collected at the exhaust pipes of the engine, generator and incinerator, and boiler steam pipes where exhaust gases or steam of high temperature pass through. In most cases, types of ACMs were asbestos-containing fabrics such as asbestos tape. Friable ACMs were also found in some cases. Use of ACMs on ships was relevant to built time and owner of the ships rather than type and tonnage of the ships. Conclusions: ACMs were found from most ships built prior to 2000s. Therefore, measures for preventing asbestos-related diseases such as preparation of asbestos map on the ship and installation of warning signs, hazard communication with workers (ship-repairing workers, engine room workers and etc.), and follow-up for worker's health management are needed.

Investigation and Risk Assessment of Asbestos-Containing Materials used in Buildings (건축물에 사용된 석면함유물질(ACMs)의 조사 및 위해성 평가)

  • Kim, Hong-Kwan;Chon, Young Woo;Roh, Young Man;Hong, Seung-Han;Kim, Chi-Nyon;Lee, Ik-Mo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.28 no.1
    • /
    • pp.35-42
    • /
    • 2018
  • Objectives: The objectives of this study are to research the usage characteristics of asbestos-containing building materials and to conduct exposure risk assessment by applying no. 2016-230 "Methods of Risk Assessment of Asbestos-Containing Buildings" from the Ministry of Environment. Methods: One hundred buildings located in the Seoul and Gyeonggi-Incheon area were chosen, with 29 in Seoul, 20 in Incheon, and 51 in Gyeonggi-do Province. The year of construction was divided between three buildings in the 1970s, 11 buildings in the 1980s, 42 buildings in the 1990s, and 44 buildings in the 2000s. The bulk samples were analyzed by using a polarizing microscope after a pre-process using a stereomicroscope in a hood with an HEPA filter. This study defined ACMs(asbestos-containing materials) as asbestos when the content percentage was over 1% in the analysis result. Methods and standards of risk assessment of asbestos-containing building materials were conducted by refering to no. 2016-230 "Method of Risk Assessment of Asbestos-Containing Buildings" from the Ministry of Environment. The risk of exposure to ACMs was rated by a score based on three categories(high, middle, low risk of asbestos exposure). Results: In this study, 30 of the 100 buildings and 36 of the 416 bulk samples(8.6%) were found to have had asbestos. Asbestos was detected at a high rate, in 18 out of 42, in buildings constructed in the 1990s and at the lowest rate(7 out of 44) for buildings constructed in the 2000s. As a result of the evaluation according to no. 2016-230 "Method of Risk Assessment of Asbestos-Containing Buildings" of the Ministry of Environment, the risk assessment level of two asbestos-containing building materials was found to be "Medium", and 28 buildings materials were found to be at the "Low" level. Conclusion: As asbestos is regulated by the government, it is required to conduct active management and implemention by introducing methods of risk assessment of asbestos exposure that are supported by data from various situations. In the case of buildings owned by individuals, building owners should be aware of the risk of exposure to asbestos.

Review on Occupational Exposure To Asbestos in Korea (우리나라 석면 취급 산업장 석면 농도에 대한 고찰)

  • Park, Donguk;Choi, Sangjun;Yoon, Chungsik
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.19 no.3
    • /
    • pp.307-320
    • /
    • 2009
  • This study was conducted not only to review airborne asbestos levels reported in workplaces in Korea, but also to analyze their levels according to various characteristics All asbestos concentration reported as either geometric mean (GM) and geometric standard deviation (GSD) or ranges were transformed to arithmetic mean to estimate exposure level. In addition, weighted arithmetic means (WAMs) were calculated to weigh asbestos levels based on the different number of samples. Differences of asbestos levels among several characteristics such as industry type, decade, operation and sampling and analytical methods were analyzed using analysis of variance (ANOVA). The number of articles studying asbestos levels from workplaces was found to be 9 including two report types. Five of those were reported prior to 1990s and rest of them after 1990s. Only several industries such as asbestos textile, asbestos cement, brake-lining repair shops were studied, while various industries using asbestos or asbestos containing materials (ACMs) were not studied. ANOVA found that asbestos exposure levels (WAM = 5.26f/cc) reported from textile industry were significantly higher than those from other industries (cement = 0.63f/cc, brake-lining = 0.2f/cc - 0.47f/cc) (p < 0.0001). Average exposure levels studied prior to the 1990s (3.13f/cc) were found to be significantly higher than that (0.86f/cc) after the 1990s (p<0.0001). All WAMs reported until the 1994 were found to be higher than the current occupational exposure limits (0.1f/cc). This study recommends that retrospective exposure to asbestos based on various industry types and operations should be assessed.

An Investigation on the Airborne Asbestos Concentrations using PCM and TEM in the Public Buildings in Seoul (PCM과 TEM을 이용한 서울지역 일부 공공 건축물의 실내공기 중 석면농도 조사)

  • Chung, Sook-Nye;Nam, Eun-Jung;Hwang, Soon-Yong;Oh, Seok-Ryul;Shin, Jin-Ho;Eom, Seok Won;Chae, Young-Zoo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.21 no.3
    • /
    • pp.139-145
    • /
    • 2011
  • Objectives: This investigation is purposed to evaluate the airborne asbestos concentrations in the public buildings having asbestos containing materials(ACMs) in Seoul. Methods: The Seoul Metropolitan Government carried out an asbestos survey to the city-owned public buildings to identify the level of risk exposure, classified into low, moderate and high risk. To evaluate the airborne concentration of asbestos, 11 sampling sites in ten buildings based on the survey were selected. The air samples from the eleven sites were analyzed by Phase Contrast Microscopy(PCM) and Transmission Electron Microscopy (TEM), and compared the analytical results from the both. Results: 1. The airborne fiber concentrations by PCM were less than the detection limit($7f/mm^2$) in 9(82%) out of 11 sampling sites. The highest concentration was 0.0043 f/cc, but it was below the guideline value for indoor air quality(0.01 f/cc), proposed by the Ministry of Environment, Korea. 2. In two sampling sites, having moderate risk level, the chrysotile was identified and showed it's concentrations of 0.0102 s/cc and 0.0058 s/cc, less than $5{\mu}m$ lengths. 3. The ACMs identified in the two sampling sites were a packing material(65% of chrysotile) in mechanical area and a thermal system insulation(5% of chrysotile) in a boiler room. Having more possibility of asbestos emission in the mechanical area, it would be required to set up and carry out the asbestos management plan. Conclusions: Based on the result of this study, the airborne asbestos concentrations in the public buildings with ACMs were generally lower than the guideline value for indoor air quality. There are widespread concerns about the possible health risk resulting from the presence of airborne asbestos fibers in the public buildings. Most of the previous studies about airborne asbestos analysis in Korea were performed based on PCM method that asbestos and non-asbestos fibers are counted together. In the public and commercial buildings, having ACMs, it is suggested that the asbestos be analyzed by TEM method to identify asbestos due to concerns about asbestos exposure to workers and unspecified people.

Estimation of the Asbestos Handling History of Workers in the Automobile Manufacturing Industry in Korea (자동차 제조 사업장 근로자들의 석면 취급 이력 추정)

  • Choi, Sangjun;Kim, Shinbum;Choi, Youngeun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.27 no.4
    • /
    • pp.423-432
    • /
    • 2017
  • Objectives: This study was conducted to evaluate asbestos handling history of workers at automobile manufacturing plants in Korea. Methods: National regulations on asbestos and Korea Occupational Safety and Health Agency(KOSHA) database on the information of asbestos containing products were reviewed. We investigated asbestos related materials from one automobile manufacturing plant. Material safety data sheets(MSDS) collected in 2010, work environment monitoring results reported from 2000 to 2013, trade union reports and asbestos survey reports were reviewed. We also interviewed workers with long career and did walk-through survey. Results: The Ministry of Labor in Korea has permitted asbestos manufacturing since 1990. In 1997, the use of crocidolite and amosite asbestos were banned. In 2007, the Korean government announced a total ban on the manufacturing, importation and use of all kinds of asbestos, which took full effect in 2009. A total of 174 asbestos products information from KOSHA database was analyzed. Extruded cement panel for building, special brake for crane farm machinery, gasket, joint sheet and thermal insulator were produced until 2007. From automobile manufacturing plant survey, we confirmed that asbestos containing materials(ACM) such as gasket, heating induction materials have been used until 2011. Asbestos containing building materials(ACBM) such as bamlites, slate and ceiling tex were reported at 122 asbestos dismantling projects in 2014. Conclusion: Although the use of all kinds of asbestos were banned from 2009, ACMs and ACBMs installed before 2009 were still found at automobile manufacturing plant until 2011 and 2014 respectively. In particular, asbestos slates should be managed because most of slates had not been removed until 2014.