• 제목/요약/키워드: Asan area

검색결과 379건 처리시간 0.019초

Intraventricular Cavernous Malformation Radiologically Mimicking Meningioma

  • Jin, Sung-Chul;Ahn, Jae-Sung;Kwun, Byung-Duk;Kwon, Do-Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • 제44권5호
    • /
    • pp.345-347
    • /
    • 2008
  • We report a case of trigonal cavernous malformation (CM) radiologically mimicking meningioma. The computed tomographic (CT) head angiography and magnetic resonance imaging (MRI) showed a partially calcified lesion with slight contrast enhancement located in the area of the left atrium of lateral ventricle. The lesion was completely removed using microsurgery with a parieto-occipital transcortical approach. The resected mass was histologically confirmed as CM. CM should be considered as differential diagnosis in case of the atrial mass lesion due to lack of hemosiderin ring characteristically seen other seated CM.

Modified Trajectory of C2 Laminar Screw-Double Bicortical Purchase of the Inferiorly Crossing Screw

  • Rhee, Woo-Tack;You, Seung-Hoon;Jang, Yeon-Gyu;Lee, Sang-Youl
    • Journal of Korean Neurosurgical Society
    • /
    • 제43권2호
    • /
    • pp.119-122
    • /
    • 2008
  • The crossing laminar screw fixation might be the most recently developed approach among various fixation techniques for C2. The new construct has stability comparable to transarticular or transpedicular screw fixation without risk of vertebral artery injury. Quantitative anatomical studies about C2 vertebra suggest significant variation in the thickness of C2 lamina as well as cross sectional area of junction of lamina and spinous process. We present an elderly patient who underwent an occipito-cervical stabilization incorporating crossed C2 laminar screw fixation. We preoperatively recognized that she had low profiles of C2 lamina, and thus made a modification of trajectory for the inferiorly crossing screw. We introduce a simple modification of crossing C2 laminar screw technique to improve stability in patients with low laminar profiles.

투시 조영 검사 시 환자 선량 관리를 위한 진단참고선량 구축에 관한 연구 (UGI, Esophagography 기준) (Fluoroscopy examinations for the management of patient dose study on the establishment of diagnostic reference level (UGI, Esophagography standards))

  • 홍선숙;박은성;조준영;성민숙;양한준
    • 대한디지털의료영상학회논문지
    • /
    • 제14권1호
    • /
    • pp.1-6
    • /
    • 2012
  • This round of tests in patients with UGI and Esophagography data collected by national and international reference levels based on the original set of guidelines and fluoroscopy, through the provision of medical radiation exposure reduction and further optimization of Defense to realize that is intended. 359 names in our hospital underwent Esophagography 302 patients who underwent UGI average fluoroscopy time and number of images to calculate the average 21 cm Acryl phantom dose for 10 seconds and 20 seconds, average area dose and the area dose of 1 spot image, 5 spot consecutive images by measuring the patient dose and third quartile of the mean area dose was set seonryangin reference dose. Esophagography average patient dose was set to 30.05 $Gy{\cdot}cm^2$, DRL was set at a 25.37 $Gy{\cdot}cm^2$. Average dose of UGI patients were selected as 45.33 $Gy{\cdot}cm^2$, DRL was set at a 34 $Gy{\cdot}cm^2$. UGI patients with established average dose recommended in the 2008 national recommendation from the UGI examination with a dose of less than 49.7 $Gy{\cdot}cm^2$ seonryangin is evaluated. This Note examines the dose of self-aware through education recognizes the importance of dose reduction and examine if their efforts and further reduce patient dose could achieve optimization of the medical exposure is considered.

  • PDF

GIS를 이용한 아산시 마을습지 인벤토리 구축 및 관리 방안 연구 (A Study on Development of Village Wetlands Inventory Using GIS and Establishment of Management Methods in Asan City, Korea)

  • 박미옥;양승빈;구본학
    • 한국환경복원기술학회지
    • /
    • 제18권6호
    • /
    • pp.167-177
    • /
    • 2015
  • This study was conducted to establish an inventory and propose conservation strategies for 'village wetlands' in Asan city, Korea, using GIS. As results, the village wetlands are defined as such places as 'palustrine' wetland, village embankment, agricultural reservoir or small reservoirs located in or near the village and related to everyday life or farming. Firstly 807 provisional village wetlands(draft) were identified in Asan by using Arc-GIS 10.1, then 196 wetlands(final) were defined finally as village wetlands and listed the inventory of Asan Village Wetlands after being validated through office works and field survey. The office works analyzed minimum area(greater than $625m^2$), satellite images, the Korea Land Information System, land use map and land coverage map. To evaluate the function and conservation values, the 37 wetlands were selected for detailed surveying and function assessment based on the following criteria : 1) doubled code both wetland and reservoir at digital map, 2) located less than 100m from village and 3) ecologically connected to such ecological resources as seaside mudflats, mountains and green area and ecological passages for small size wildlifes. As the result of the wetland function assessments by the RAM method, 7 wetlands were found to have 'high' wetland function (conservation) 18 wetlands were 'medium' (enhancement) and 12 wetlands were 'low' (restoration or enhancement). Enhancing biodiversity and ecosystem services through ecological management of wetlands in Asan and connecting with the Ecological Natural Degree were proposed.

아산호의 생태학적 연구 2.식물플랑크톤 군집 구조 (Ecological Studies on the Asan Reservoir. 2. Phytoplankton Community Structure)

  • 김영길;신윤근
    • 생태와환경
    • /
    • 제35권3호통권99호
    • /
    • pp.187-197
    • /
    • 2002
  • 아산호에서 1997년 3월부터 1997년 11월까지 6회에 걸쳐 식물플랑크톤 군집구조를 파악하기 위한 연구를 수행하였다. 19개 정점에서 관찰된 식물플랑크톤 분류군은 총 204종군으로, 각 분류군별 출현비는 녹조류 51%, 규조류 29%, cyanobacteria 12%, 와편모조류가 2%, 유글레나류 4%, 기타 편모조류가 2% 이었다. 식물플랑크톤의 현존량은 741ce11s/m떼서 613,066ce11s/ml의 범위로 매우 높은 수준으로 나타났다. 현존량은 7월에 가장 높았고 9월, 6월, 3월, 11월, 5월 순으로 나타났다. 계절에 관계없이 지속적으로 녹조상태인 것으로 판단되며, 녹조원인생물은 Micractium pusillum, Stephandiscus hantzschii, Dictyospharium pulchellum, cryptomonad (> 20 ${\mu}$, Microcystis aeruginosa, Oscillatoria tenuis, Oscillatoria sp., Aphanocapsa sp. Euglena sp., Volvox aureus 이었다. 여름철에 cyanobacteria에 의한 녹조현상이 현저하였다. 식물플랑크톤의 종다양성은 0.13${\sim}$의 범위로 시${\cdot}$공간적으로 차이가 매우 컸다. 집괴 분석한 결과 전반적으로 아산호 하류수역과 상류수역 투 개의 수역으로 구분이 되었다.

Unilateral Extrapedicular Vertebroplasty and Kyphoplasty in Lumbar Compression Fractures : Technique, Anatomy and Preliminary Results

  • Cho, Sung-Min;Nam, Yong-Suk;Cho, Byung-Moon;Lee, Sang-Youl;Oh, Sae-Moon;Kim, Moon-Kyu
    • Journal of Korean Neurosurgical Society
    • /
    • 제49권5호
    • /
    • pp.273-277
    • /
    • 2011
  • Objective : A single balloon extrapedicular kyphoplasty has been introduced as one of the unilateral approaches for thoracic compression fractures; however, the unilateral extrapedicular technique in the lumbar area needs a further understanding of structures in the lumbar area. The purpose of the present study is to describe methods and pitfalls of this procedure based on the anatomy of the lumbar area and to analyze clinical outcome and complications. Methods : Anatomical evaluation was performed with 2 human cadavers. A retrospective review of unilateral extrapedicular approaches yielded 74 vertebral levels in 55 patients that were treated with unilateral extrapedicular vertebroplasty and kyphoplasty. Radiographic assessment included the restoration rate of vertebral height and correction of kyphosis. Results : Anatomical evaluation indicates that the safe needle entry zone of bone for the extrapedicular approach was located in the supero-lateral aspect of the junction between the pedicle and vertebral body. The unilateral extrapedicular procedure achieved adequate pain relief with a mean decreases in pain severity of $7.25{\pm}1.5$ and $2.0{\pm}1.4$, respectively. Complications were 1 retroperitoneal hematoma, 6 unilateral fillings and 3 epidural leak of the polymethylmethacrylate. Conclusion : The method of a unilateral extrapedicular approach in kyphoplasty and vertebroplasty in the lumbar area might be similar to that in thoracic approach using a route via the extrapedicular space. However, different anatomical characteristics of the lumbar area should be considered.

Simple Interrupted Suturing for Aortic Valve Replacement in Patients with Severe Aortic Stenosis

  • Lee, Jun Oh;Lee, Chee-hoon;Kim, Ho Jin;Kim, Joon Bum;Jung, Sung-Ho;Joo, Suk Jung;Chung, Cheol Hyun;Lee, Jae Won
    • Journal of Chest Surgery
    • /
    • 제53권6호
    • /
    • pp.332-338
    • /
    • 2020
  • Background: Attaining an adequate effective orifice area (EOA) is definitive goal in aortic valve replacement (AVR). The simple interrupted suture (SIS) technique could be a solution to achieve this goal, but limited data are available in the literature. This study aimed to compare hemodynamic differences between the SIS and non-everting mattress suture (NMS) techniques. Methods: From our database, 215 patients who underwent AVR for severe aortic stenosis were extracted to form the overall cohort. From March 2015 to November 2016, the SIS technique was used in 79 patients, while the NMS technique was used in 136 patients. Hemodynamic outcomes were evaluated, as detected by transthoracic echocardiography and computed tomography. Results: There were no significant differences in baseline characteristics between the 2 groups. On immediate postoperative echocardiography, the SIS group showed a significantly wider EOA (1.6±0.4 vs. 1.4±0.5 ㎠, p=0.007) and a lower mean pressure gradient (PG) (13.3±5.4 vs. 17.0±6.0 mm Hg, p<0.001) than the NMS group. On follow-up echocardiography, the SIS group continued to have a wider EOA (1.6±0.4 vs. 1.4±0.3 ㎠, p<0.001) and a lower mean PG (11.0±5.1 vs. 14.1±5.5 mm Hg, p<0.001). There was no significant difference in paravalvular leakage. Conclusion: The SIS technique for AVR was associated with a wider EOA and a lower mean PG. The SIS technique could be a reasonable option for AVR.

Technical Feasibility of Quantitative Measurement of Various Degrees of Small Bowel Motility Using Cine Magnetic Resonance Imaging

  • Ji Young Choi;Jihye Yun;Subin Heo;Dong Wook Kim;Sang Hyun Choi;Jiyoung Yoon;Kyuwon Kim;Kee Wook Jung;Seung-Jae Myung
    • Korean Journal of Radiology
    • /
    • 제24권11호
    • /
    • pp.1093-1101
    • /
    • 2023
  • Objective: Cine magnetic resonance imaging (MRI) has emerged as a noninvasive method to quantitatively assess bowel motility. However, its accuracy in measuring various degrees of small bowel motility has not been extensively evaluated. We aimed to draw a quantitative small bowel motility score from cine MRI and evaluate its performance in a population with varying degrees of small bowel motility. Materials and Methods: A total of 174 participants (28.5 ± 7.6 years; 135 males) underwent a 22-second-long cine MRI sequence (2-dimensional balanced turbo-field echo; 0.5 seconds per image) approximately 5 minutes after being intravenously administered 10 mg of scopolamine-N-butyl bromide to deliberately create diverse degrees of small bowel motility. In a manually segmented area of the small bowel, motility was automatically quantified using a nonrigid registration and calculated as a quantitative motility score. The mean value (MV) of motility grades visually assessed by two radiologists was used as a reference standard. The quantitative motility score's correlation (Spearman's ρ) with the reference standard and performance (area under the receiver operating characteristics curve [AUROC], sensitivity, and specificity) for diagnosing adynamic small bowel (MV of 1) were evaluated. Results: For the MV of the quantitative motility scores at grades 1, 1.5, 2, 2.5, and 3, the mean ± standard deviation values were 0.019 ± 0.003, 0.027 ± 0.010, 0.033 ± 0.008, 0.032 ± 0.009, and 0.043 ± 0.013, respectively. There was a significant positive correlation between the quantitative motility score and the MV (ρ = 0.531, P < 0.001). The AUROC value for diagnosing a MV of 1 (i.e., adynamic small bowel) was 0.953 (95% confidence interval, 0.923-0.984). Moreover, the optimal cutoff for the quantitative motility score was 0.024, with a sensitivity of 100% (15/15) and specificity of 89.9% (143/159). Conclusion: The quantitative motility score calculated from a cine MRI enables diagnosis of an adynamic small bowel, and potentially discerns various degrees of bowel motility.

New Method for Combined Quantitative Assessment of Air-Trapping and Emphysema on Chest Computed Tomography in Chronic Obstructive Pulmonary Disease: Comparison with Parametric Response Mapping

  • Hye Jeon Hwang;Joon Beom Seo;Sang Min Lee;Namkug Kim;Jaeyoun Yi;Jae Seung Lee;Sei Won Lee;Yeon-Mok Oh;Sang-Do Lee
    • Korean Journal of Radiology
    • /
    • 제22권10호
    • /
    • pp.1719-1729
    • /
    • 2021
  • Objective: Emphysema and small-airway disease are the two major components of chronic obstructive pulmonary disease (COPD). We propose a novel method of quantitative computed tomography (CT) emphysema air-trapping composite (EAtC) mapping to assess each COPD component. We analyzed the potential use of this method for assessing lung function in patients with COPD. Materials and Methods: A total of 584 patients with COPD underwent inspiration and expiration CTs. Using pairwise analysis of inspiration and expiration CTs with non-rigid registration, EAtC mapping classified lung parenchyma into three areas: Normal, functional air trapping (fAT), and emphysema (Emph). We defined fAT as the area with a density change of less than 60 Hounsfield units (HU) between inspiration and expiration CTs among areas with a density less than -856 HU on inspiration CT. The volume fraction of each area was compared with clinical parameters and pulmonary function tests (PFTs). The results were compared with those of parametric response mapping (PRM) analysis. Results: The relative volumes of the EAtC classes differed according to the Global Initiative for Chronic Obstructive Lung Disease stages (p < 0.001). Each class showed moderate correlations with forced expiratory volume in 1 second (FEV1) and FEV1/forced vital capacity (FVC) (r = -0.659-0.674, p < 0.001). Both fAT and Emph were significant predictors of FEV1 and FEV1/FVC (R2 = 0.352 and 0.488, respectively; p < 0.001). fAT was a significant predictor of mean forced expiratory flow between 25% and 75% and residual volume/total vital capacity (R2 = 0.264 and 0.233, respectively; p < 0.001), while Emph and age were significant predictors of carbon monoxide diffusing capacity (R2 = 0.303; p < 0.001). fAT showed better correlations with PFTs than with small-airway disease on PRM. Conclusion: The proposed quantitative CT EAtC mapping provides comprehensive lung functional information on each disease component of COPD, which may serve as an imaging biomarker of lung function.

Duran Ring을 이용한 삼천판륜의 삼차원적 재건술 (Three-dimensional Reconstruction of Tricuspid Annulus with the Duran Ring)

  • 유동곤;김종욱;박종빈;주석중;이재원
    • Journal of Chest Surgery
    • /
    • 제38권1호
    • /
    • pp.88-90
    • /
    • 2005
  • 유연한 Duran Ring을 이용하여 삼첨판륜 성형술을 시행하면 생리적인 삼첨판륜 재건이 가능하고 삼첨판륜의 동적인 형태를 유지할 수 있다. 삼첨판륜의 동적인 형태와 구경을 유지할 수 있는 삼차원적 삼첨판륜 재건술을 소개한다.