• 제목/요약/키워드: As22U

검색결과 873건 처리시간 0.031초

Behavioral analysis of Pacific abalone, Haliotis discus hannai, reveals its feeding preference and attraction potential for brown alga, Sargassum horneri

  • Chae-Eun Yu;Yeo-Reum Kim;Gyeong-Eon Noh;Jong-Myoung Kim
    • Fisheries and Aquatic Sciences
    • /
    • 제26권5호
    • /
    • pp.355-365
    • /
    • 2023
  • The Pacific abalone, Haliotis discus hannai, is a highly valued and industrially important aquaculture species with growing demands of the expanding abalone aquaculture industry. To explore the feasibility of using the brown alga, Sargassum horneri, as a potential substitute for abalone feed, it is important to identify the feed preference and attractant effect of S. horneri on Pacific abalone. Our experiments indicated that the feeding-associated movement of abalone could be detected using a video tracking system under indirect illumination with dim red light. To further analyze the attraction potentials of various test materials, preference analysis was performed using Avicel-coated glass plates with ground powders of various seaweeds (e.g., S. horneri, Saccharina japonica, and Undaria pinnatifida) and commercial abalone feed, together with coffee waste. Heat map analysis indicated greater attraction by the kelp S. japonica than by S. horneri and commercial feed, which showed similar preference levels. Feeding preference based on the area of Avicel eaten by abalone showed a significant preference for U. pinnatifida over S. horneri (feeding area: 68.6 ± 20.1% vs. 37.5 ± 22.4%, p < 0.05). Additionally, the feeding area was significantly greater for plates with S. japonica than for plates with S. horneri (44.0 ± 16.6% vs. 22.6 ± 15.4%, p < 0.05). There was no significant difference in feeding area between commercial feed and S. horneri (31.7 ± 11.6% vs. 31.6 ± 20.2%, p > 0.05). The methanol extracts attracted abalone in the following order: U. pinnatifida > S. horneri > S. japonica > commercial feed > coffee waste. To determine the attractive effects of the components of methanol extracts, mixtures of methanol extracts of commercial feed with increasing amounts of S. horneri were examined. The results showed a significant increase in feeding preference upon addition of S. horneri up to 50% and 75%, suggesting its potential for use as an appetite-enhancing feed additive. This study identified conditions that can be successfully used to monitor the movement of Pacific abalone; the results of preference analysis confirmed that abalone exhibited similar attraction and feeding preference for S. horneri, compared with commercial feed.

한우 및 돼지의 혈액화학치에 관한 연구 (Studies on the Blood Chemistry of Korean Native Cattle and Pigs)

  • 도재철;이창우;손재권;정종식
    • 한국동물위생학회지
    • /
    • 제13권1호
    • /
    • pp.49-53
    • /
    • 1990
  • In order to know the range in blood chemical values and enzyme activities of korean native cattle and pigs being raised in kyongbuk province, the mean values of serum protein compositions, enzyme activities(GOT, GPT, ALP), cholesterol, glucose, bilirubin, creatinine, urea nitrogen and uric acid were determined and the results obtained were as follows ; 1. Mean contents of total protein, albumin, globulin and A / G ratio for the korean native male cattle were $7.28{\pm}0.86$ g / dl, 43.39{\pm}0.65$ g / dl, 43.83{\pm}0.92$ g / dl & 40.95{\pm}0.34$;for the male pigs were 47.39{\pm}0.84$ g / dl, 43.63{\pm}0.43$ g / dl, 43.77{\pm}0.88$ g / dl, 40.97{\pm}0.26$;for the female pigs were 47.60{\pm}0.68$ g/ dl, 43.54{\pm}0.58$ g / dl, 43.90{\pm}0.74$ g / dl, 41.02{\pm}0.34. 2.$ Mean activities of GOT, GPT and ALP for the korean native male cattle were 448.3{\pm}11.6$ U, 429.6{\pm}4.6$ U, 413.7{\pm}2.8$ U; for the male pigs were 458.6{\pm}10.6$ U, 438.6{\pm}5.3$ U, 424.9{\pm}9.2$ U; for the female pigs were 443.9{\pm}10.8$ U, 440.5{\pm}4.6$ U, 413.9{\pm}3.4$ U. 3. Mean contents of cholesterol, glucose and bilirubin for the korean native male cattle were 4108.7{\pm}31.8$ mg / dl, 488.2{\pm}26.4$ mg / dl, $0.69{\pm}0.52$ mg / dl; for the male pigs were 4105.9{\pm}18.3$ mg / dl, 4102.9{\pm}22.3$ mg / dl, 40.70{\pm}0.18$ mg / dl: for the female pigs were $113.1{\pm}20.9$ mg / dl , 4103.2{\pm}23.9$ mg / dl, 40.49{\pm}0.21$ mg / dl. 4. Mean contents of creatinine, urea nitrogen and uric acid for the korean native male cattle were 42.86{\pm}0.69$ mg / dl, $18.1{\pm}5.0$ mg / dl, 41.38{\pm}0.66$ mg /dl; for the male pigs were 42.20{\pm}0.51$ mg / dl, $18.2{\pm}4.3$ mg / dl, 40.29{\pm}0.10$ mg /dl: for the female pigs were 42.36{\pm}0.70$ mg / dl, $20.5{\pm}5.4$ mg / dl, 40.69{\pm}0.27$ mg / dl.

  • PDF

Pin-on-Flat Surface Test를 이용한 초고장력강판 스탬핑 금형의 정량적 스크래치 수명평가 (Quantitative Evaluation of Scratch Related Tool Life for Stamping of UHSS Using Pin-on-Flat Surface Test)

  • 최홍석;김성귀;김병민;고대철
    • 소성∙가공
    • /
    • 제22권2호
    • /
    • pp.86-92
    • /
    • 2013
  • When stamping ultra-high-strength steel (UHSS), the phenomenon of galling, which corresponds to a transfer of material from the sheet to the tool surface, occurs because of the high contact pressure between tool and workpiece. Galling leads to increased friction, unstable interface conditions, scratches on the sheet and the tool surfaces and, eventually, premature tool surface failures. Therefore, a simple and accurate evaluation method for tool scratching is necessary for the selection of tool material and coating, as well as for a better optimization of process conditions such as blank holder force and die radius. In this study, the pin-on-disc (PODT) and pin-on-flat surface (POFST) tests are conducted to quantitatively evaluate scratch-related tool life for stamping of UHSS. The variation of the friction coefficient is used as an indicator of scratch resulted from galling. The U-channel ironing test (UCIT) is performed in order to validate the results of the friction tests. This study shows that the POFST test provides a good quantitative estimation of tool life based on the occurrence of scratch.

Breathing Measurement and Sleep Apnea Detection Experiment and Analysis using Piezoelectric Sensor

  • Cho, Seokhyang;Cho, Seung-Ho
    • 한국컴퓨터정보학회논문지
    • /
    • 제22권11호
    • /
    • pp.17-23
    • /
    • 2017
  • In this paper, we implemented a respiration measurement system consisting of piezoelectric sensor, respiration signal processing device, and a viewer on a notebook. We tried an experiment for measuring respiration and detecting sleep apnea syndrome when a subject lay on a bed. We applied the respiration measurement algorithm to sensor data obtained from four subjects. In order to get a good graph shape, data manipulation methods such as moving averages and maximum values were applied. The window size for moving average was chosen as N=70, and the threshold value for each subject was customized. In this case, the proposed system showed 96.0% accuracy. When the maximum value among 90 data was applied instead of moving average, our system achieved 95.1% accuracy. In an experiment for detecting sleep apnea syndrome, the system showed that sleep apnea occurred correctly and calculated the average interval of sleep apnea. While infants or the elderly as well as patients with sleep apnea syndrome are lying down on a bed, our results are also expected to be able to cope with some accidental emergency situation by observing their respiration and detecting sleep apnea.

NEAR-INFRARED SPECTROSCOPY OF CO RO-VIBRATIONAL ABSORPTION TOWARD HEAVILY OBSCURED AGNs

  • Shirahata, Mai;Nakagawa, Takao;Oyabu, Shinki;Usuda, Tomonori
    • 천문학논총
    • /
    • 제32권1호
    • /
    • pp.169-173
    • /
    • 2017
  • We provide a new physical insight on the hot molecular clouds near the nucleus of the obscured AGNs. We performed near-infrared spectroscopic observations of heavily obscured AGNs in order to reveal physical characteristics of molecular clouds, especially focused on the CO fundamental ro-vibrational absorption around $4.7{\mu}m$. We have made systematic moderate-resolution spectroscopic observations toward 30 representative (U)LIRGs using the AKARI/IRC, and some of the ULIRGs showed the strong CO absorption feature. For three bright (U)LIRGs that show a steep red continuum with the deep CO absorption feature, IRAS 08572+3915, UGC 05101, and IRAS 01250+2832, we have also made high-resolution spectroscopic observations using the Subaru/IRCS. We have successfully detected many absorption lines up to highly excited rotational levels, and these lines are very deep and extremely broad. The derived physical conditions of molecular clouds are extreme; the gas temperature is as high as several 100 to a 1000 K, the $H_2$ column density is larger than $10^{22}cm^{-2}$, and the gas density is greater than $10^7cm^{-3}$. Such hot and dense molecular clouds must exist around the central engine of the AGN.

발효법제에 의한 감초의 Flavonoid 무배당체의 생산 (Production of Flavonoid Aglycone from Korean Glycyrrhizae Radix by Biofermentation Process)

  • 나인수;박민주;노종훈;민진우;방면호;양덕춘
    • 동의생리병리학회지
    • /
    • 제22권3호
    • /
    • pp.569-574
    • /
    • 2008
  • The GUE6 was isolated from ethyl acetate fraction of Glycyrrhiza uralensis and confirmed as liquiritin. Liquiritin(LQ) treated with ${\beta}$-glucosidase from plant(Prunus dulcis) and bacteria(Lactobacillus pentosus) crude enzymes. The ${\beta}$-glucosidase activities of crude enzymes were 229.8 U/g(Prunus dulcis) and 19.17 U/ml(Lactobacillus pentosus), respectively. Liquiritin(LQ) biotransformed into liquiritigenin(LQG) by ${\beta}$-glucosidase from crude enzymes. The EtOAc fraction(GUE6) and the converted product were identified as liquiritin and liquiritigenin, by TLC chromatogram, $^{1}H$-NMR and $^{13}C$-NMR.

OGC기반 도시공간정보 데이터 연동서비스를 위한 상호연계기술 개발 연구 (Development of Interconnection Technology for Urban Geographic Information on OGC Standards)

  • 김태훈;김성수;홍창희;황정래
    • Spatial Information Research
    • /
    • 제21권1호
    • /
    • pp.15-22
    • /
    • 2013
  • 최근 u-City, Smart city 등 첨단도시를 구축하려는 다양한 움직임이 있으며, 이러한 첨단도시의 기반인프라로서 공간정보가 필수적인 요소로 인식되고 있다. 그러나 많은 경우에 있어서 기존에 구축된 공간정보 즉 GIS 데이터는 포맷의 다양성으로 인한 자료간 호환성 부족으로 기관간 상호연계 및 대국민 웹서비스 등에서 어려움을 겪어왔다. 이에 본 연구에서는 이기종 분산환경에서 기 구축되어 활용되고 있는 GIS 및 UIS 데이터를 국제표준인 OGC(Open Geospatial Consortium) 표준기반으로 상호연동할 수 있도록 중계역할을 해주는 상호연계서버를 개발하고, 테스트베드 적용을 통해 성능을 검증하였다. 해당 성과는 향후 첨단도시의 통합관제플랫폼 및 화산재해대응플랫폼 등에 적용되어 기 구축 DB의 활용성을 제고하고 시스템의 효율성을 높일 수 있으리라 기대된다.

Efficacy Test of Polycan, a Beta-Glucan Originated from Aureobasidium pullulans SM-2001, on Anterior Cruciate Ligament Transection and Partial Medial Meniscectomy-Induced-Osteoarthritis Rats

  • Kim, Joo-Wan;Cho, Hyung-Rae;Ku, Sae-Kwang
    • Journal of Microbiology and Biotechnology
    • /
    • 제22권2호
    • /
    • pp.274-282
    • /
    • 2012
  • The object of this study was to assess the efficacy of Polycan from Aureobasidium pullulans SM-2001, which is composed mostly of beta-1,3-1,6-glucan, on osteoarthritis (OA)-induced by anterior cruciate ligament transection and partial medial meniscectomy (ACLT&PMM). Three different dosages of Polycan (85, 42.5, and 21.25 mg/kg) were orally administered once a day for 84 days to male rats a week after ACLT&PMM surgery. Changes in the circumference and maximum extension angle of each knee, and in cartilage histopathology were assessed using Mankin scores 12 weeks after Polycan administration. In addition, cartilage proliferation was evaluated using bromodeoxyuridine (BrdU). As the result of ACLT&PMM, classic OA was induced with increases in maximum extension angles, edematous knees changes, and capsule thickness, as well as decreases in chondrocyte proliferation, cartilages degenerative changes, and loss of articular cartilage. However, these changes (except for capsule thickness) were markedly inhibited in all Polycan- and diclofenac sodium-treated groups compared with OA control. Although diclofenac sodium did not influence BrdU uptake, BrdU-immunoreactive cells were increased with all dosages of Polycan, which means that Polycan treatment induced proliferation of chondrocytes in the surface articular cartilage of the tibia and femur. The results obtained in this study suggest that 84 days of continuous oral treatment of three different dosages of Polycan led to lesser degrees of articular stiffness and histological cartilage damage compared with OA controls 91 days after OA inducement, suggesting that the optimal Polycan dosage to treat OA is 42.5 mg/kg based on the present study.

TSH, FT4 검사의 Two-point Calibration Curve 적용의 유용성 평가 (Utility Evaluation of Two-point Calibration Curve applied for TSH, FT4 Tests)

  • 박혜미;유선희;이선호;김년옥
    • 핵의학기술
    • /
    • 제20권2호
    • /
    • pp.75-79
    • /
    • 2016
  • Purpose The ASAN Medical Center, Nuclear Medicine performs TSH (Thyroid stimulating hormone) and FT4 (Free Thyroxine) tests 8 times per day. Accordingly, 70 ~ 80 kit tubes are consumed every day for the measurements and the time consumed for reagent dispensing averages over 170 seconds, where the TAT (turnaround time) may be effected when the number of test samples is larger than expected. Therefore, the following test was conducted with the purpose to reduce the number of kit tubes consumed, and reduce the time for reagent dispensing. Materials and Methods The test is based on applying the same reagent for tests where the number of samples is 30 or less. The test for TSH was conducted 9 times from July $1^{st}$ 2015 to July $10^{th}$ 2015. The test for FT4 was conducted 4 times from June $18^{th}$ 2015 to June $22^{nd}$, 2015. Standard Solution No.2 (0.153 uU/mL) and No.5 (4.96 uU/mL) was selected as the two-point standards for the TSH test, and Standard Solution No.3 (0.777 ng/dL) and No.4 (2.044 ng/dL) was selected as the two-point standards for the FT4 test. 38 test samples were subject to correlation analysis. Results For TSH, the result of the normal test shows ranges of 0.20 ~ 0.37 uU/mL for Control1, 0.53 ~ 0.71 uU/mL for Control2, and 6.77 ~ 7.94uU/mL for Control3, while the result of two-point calibration curve test shows ranges of 0.18 ~ 0.27 uU/mL for Control1, 0.53 ~ 0.71 uU/mL for Control2, and 7.30 ~ 8.52 uU/mL for Control3. For FT4, the result of the normal test shows ranges of 0.85 ~ 0.94 ng/dL for Control1 and 4.23 ~ 4.57 ng/dL for Control2, while the result of two-point calibration curve test shows ranges of 0.61 ~ 0.75 ng/dL for Control1 and 3.88 ~ 5.71 ng/dL for Control2. For TSH, the CV% of the normal test for Control1, Control2 and Control3 are 10.5, 3.3 and 3.6 respectively, while the CV% of the two-point calibration curve test for Control1 and Control1 are 12.4, 8.2 and 5.1 respectively. The result shows an outstanding correlation of TSH: y = 0.9985x - 0.0459 $R^2=0.9986$. For FT4, the CV% of the normal test for Control1 and Control2 are 0.70 and 0.71 respectively, while the CV% of the two-point calibration curve test for Control1 and Control1 are 8.7 and 16.2 respectively. The result shows an outstanding correlation of FT4: y = 1.2674x - 0.1133 $R^2=0.9824$. Conclusion The two-point calibration curve can be efficiently applied for TSH in cases where the number of test samples is not large, since the number of samples to be re-tested increases when the result is abnormal from the calibration curve. The two-point calibration curve test should not be applied for FT4 where the results do not consistently comply with the quality assessment range. Depending on how the two-point calibration curve is applied, up to 5 test tubes can be conserved per test, and the reduced time for reagent dispensing is anticipated to have a positive effect on the TAT (turnaround time).

  • PDF

충격파-부분방전(SI-PD) 시험방법을 이용한 케이블 진단에 관한 기초 연구 (A Possible diagnostic method of cable system using SI-PD measurement)

  • 김정태;구자윤;장은;조연옥;김상준;송일근;김주용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1774-1777
    • /
    • 1996
  • In this paper, applicability of SI-PD(switching impulse - partial discharge) testing method was put on an attempt as a newly proposed diagnostic method for the underground distribution power cable system in Korea. For this purpose, SI-PD testing equipment was designed, and tests were performed using artificial needle-type defects integrated into the 22.9 kV CN/CV cables in drder to prove its reliability. As a result, arc noises, generated from spark gap, were considerably decreased by use of a pneumatic switch immersed into oil, and artificial needle-type defects were well detected with impulse voltage level under $2U_0$. These results imply that it is likely possible to apply SI-PD measurement method as a the nondistructive test for the 22.9 kV CN/CV cable system in Korea.

  • PDF