• 제목/요약/키워드: Artificial muscle

검색결과 206건 처리시간 0.04초

뇌졸중 환자를 위한 착용형 손 재활훈련기기, DULEX (DULEX, A Wearable Hand Rehabilitation Device for Stroke Survivals)

  • 김영민;문인혁
    • 제어로봇시스템학회논문지
    • /
    • 제16권10호
    • /
    • pp.919-926
    • /
    • 2010
  • This paper proposes a wearable hand rehabilitation device, DULEX, for persons with functional paralysis of upper-limbs after stoke. DULEX has three degrees of freedom for rehabilitation exercises for wrist and fingers except the thumb. The main function of DULEX is to extend the range of motions of finger and wrist being contracture. DULEX is designed by using a parallel mechanism, and its parameters such as length and location of links are determined by kinematic analysis. The motion trajectory of the designed DULEX is aligned to human hand to prevent a slip. To reduce total weight of DULEX, artificial air muscles are used for actuating each joint motion. In feedback control, each joint angle is indirectly estimated from the relations of the input air pressure and the output muscle length. Experimental results show that DULEX is feasible in hand rehabilitation for stroke survivals.

구간분할 바이너리 제어를 이용한 로봇핸드의 동특성에 관한 연구 (A study on Dynamic Characteristics of the Robot Hand Using the Segmented Binary Control)

  • 정상화;차경래;김현욱;최석봉;김광호;박준호
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2005년도 춘계학술대회 논문집
    • /
    • pp.144-149
    • /
    • 2005
  • In recent years, as the robot technology is developed the researches on the artificial muscle actuator that enable robot to move dextrously like biological organ become active. The widely used materials for artificial muscle are the shape memory alloy and the electroactive polymer. These actuators have the higher energy density than the electromechanical actuator such as motor. However, there are some drawbacks for actuator. SMA has the hysterical dynamic characteristics. In this paper the segmented binary control for reducing the hysteresis of SMA is proposed and the simulation of anthropomorphic robotic hand is performed using ADAMS.

  • PDF

구간분할 제어를 이용한 로봇핸드의 동특성에 관한 연구 (A Study on the Dynamic Characteristics of Robot Hand based on Segmented Control)

  • 정상화;김현욱;최석봉;박준호;김광호
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 추계학술대회 논문집
    • /
    • pp.310-313
    • /
    • 2005
  • In recent years, as the robot technology is developed, the researches on the artificial muscle actuator that enable robot to move dexterously like biological organ become active. The widely used materials for artificial muscle are the shape memory alloy and the electro-active polymer. These actuators have the higher energy density than the electro-mechanical actuator such as motor. However, there are some drawbacks for actuator. SMA has the hysterical dynamic characteristics. In this paper, the simulation of anthropomophic robotic hand is performed using ADAMS and the segmented binary control for reducing the hysteresis of SMA is proposed. SMA is controlled by thermo-electric module. The relations between the force and the hysteresis are developed to verify the validity of the suggested method.

  • PDF

마스터장치의 회전강성을 고려한 공압인공근육의 원격조정 (Teleoperation of Pneumatic Artificial Muscles Based on Joint Stiffness of Master Device)

  • 김령현;강봉수
    • 대한기계학회논문집A
    • /
    • 제37권12호
    • /
    • pp.1521-1527
    • /
    • 2013
  • 본 논문에서는 마스터 조정자인 인간의 근육강도과 관절변위를 측정하여 슬레이브장치가 외부환경에 맞는 작업능력을 발휘할 수 있는 마스터/슬레이브 원격조정시스템을 제안한다. 외골격형 기구부와 경량의 관성센서를 사용하여 마스터 착용자의 편리성을 높였으며 인간의 근육과 동일한 운동특성을 가진 공압인공근육으로 슬레이브 기구장치를 구성하여 운동의 모사능력을 향상시켰다. 실험을 통해서 단순히 마스터의 위치정보만 전달하는 원격조정에 비해서 제안된 마스터는 인간 조정자가 근력의 세기를 조절함으로써 슬레이브에 작용하는 가반하중의 변화에 관계없이 균일한 제어성능을 가질 수 있었다.

감마선을 이용한 아크릴산이 그라프트된 폴리비닐알코올 하이드로겔 엑츄에이터의 제조 (Preparation and Characterization of Acrylic Acid-grafted Poly (vinyl alcohol) Hydrogel Actuators Using γ-ray Irradiation)

  • 안성준;임윤묵;권희정;김윤혜;윤민호;김종일;한동현;노영창
    • 방사선산업학회지
    • /
    • 제2권1호
    • /
    • pp.1-7
    • /
    • 2008
  • Active polymer gels expand and contract in response to certain environmental stimuli, such as the application of an electric field or a change in the pH level of the surroundings. This ability to achieve large, reversible deformations with no external mechanical loading has generated much interest in the use of these gels as biomimetic actuators and artificial muscles. In this study, poly (vinyl alcohol)(PVA) grafted acrylic acid monomer (PVA-g-AAc) hydrogels were prepared by $^{60}Co$ ${\gamma}-ray$ irradiation and their properties such as degree of grafting and weight swelling in electrostimulation as an artificial muscle and actuator were investigated.

당뇨 환자용 인공지능 복약관리 스마트워치의 사용자 경험 (Patient Experiences with Artificial Intelligence-Based Smartwatch for Diabetes Medication Monitoring Service)

  • 이미선;정수용;이휘원
    • 근관절건강학회지
    • /
    • 제29권1호
    • /
    • pp.50-59
    • /
    • 2022
  • Purpose: This qualitative study aimed to explore the experiences of patients with diabetes provided with medication monitoring using an artificial intelligence-based smartwatch. Methods: Giorgi's descriptive phenomenological methodology was applied to collect and analyze data from November 9 to December 23, 2021. The study samples were recruited by convenience sampling, and even patients with diabetes participated in in-depth interviews via video conference and telephone calls or face-to-face visits. Results: Ten sub-themes and four themes were finally revealed. The four themes were as follows: journey with unfamiliar devices, a less-than-acceptable smartwatch, insufficient functions and content for patients with diabetes to use, and efforts for regular medication behaviors and daily monitoring of patient's health conditions. Conclusion: To effectively manage diabetic conditions using digital healthcare technologies, nursing interventions were needed to identify personal needs and consider technological, psychological, aesthetic, and socioeconomic aspects of wearable devices.

Human Robot Interaction via Wearable Robot

  • Kobayashi, Hiroshi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2002년도 ICCAS
    • /
    • pp.49.5-49
    • /
    • 2002
  • $\textbullet$ Developing "muscle shit" providing muscular support $\textbullet$ Based on a new concept: wearable robot $\textbullet$ Be applicable directly to human $\textbullet$ McKibben artificial muscles are sewn into a garment

  • PDF

Sonogram of coccygeus muscle in dairy cows with different gestational ages

  • Ulum, Mokhamad Fakhrul;Frastantie, Dilla;Purwantara, Bambang
    • Journal of Animal Science and Technology
    • /
    • 제59권12호
    • /
    • pp.26.1-26.8
    • /
    • 2017
  • Background: The change in size and weight of the female reproductive organs during gestation and birth might be affect the perineal muscles and this condition in dairy cow not been reported. This study aimed to assess the ultrasonographic image of coccygeus muscle in 11 inseminated dairy cows with different gestational ages and postpartum. Methods: Gestational age was calculated based on the record of artificial insemination and confirmed by using transrectal brightness mode ultrasonography. Perineal hair between the sacrum and ischium bones was shaved along 3-5 cm before being ultrasound. The images of perineal area were obtained by transcutaneous ultrasound using a 5.0 MHz transducer. The thickness and intensity of the coccygeus muscle were measured and analyzed by gestational status and postpartum to show the differences. Results: The results showed that the thickness of coccygeus muscle increased with the increase in gestational age. Muscle intensity only increased at young gestational age. However, it decreased with the increase in gestational age (P < 0.05). Conclusions: The ultrasound image of coccygeus muscle was affected by gestational status, thus this method may be used as one of the new methods of indirect gestational detection on dairy cows.

A Study on Energy Efficiency in Walking and Stair Climbing for Elderly Wearing Complex Muscle Support System

  • Jang-hoon Shin;Hye-Kang Park;Joonyoung Jung;Dong-Woo Lee;Hyung Cheol Shin;Hwang-Jae Lee;Wan-Hee Lee
    • Physical Therapy Rehabilitation Science
    • /
    • 제11권4호
    • /
    • pp.478-487
    • /
    • 2022
  • Objective: This study was conducted to analyze the effect of wearable complex muscle support system on energy efficiency during walking in elderly. Design: Cross sectional study Methods: Twenty healthy elderly participated in this study. All subjects performed a 6 minuteswalk test(6MWT) and stair climbing test in dual, slack and no suit conditions. In each condition, oxygen consumption(VO2), metabolic equivalents(METs), energy expenditure measures(EEm), physiological cost index(PCI), walking velocity and heartrate were measured. Through repeated measured ANOVA, it was investigated whether there was a statistically significant difference in the measurement results between the three conditions. Results: In over-ground walking, VO2, METs and EEm showed significant differences between no suit and slack conditions(p<0.05). In stair climbing, VO2 showed significant difference between slack and dual conditions(p<0.05). Also, METs and EEm showed significant differences between no suit and slack, and between slack and dual conditions(p<0.05). Conclusions: Wearing the wearable complex muscle support system for elderly does not have much benefit in energy metabolism efficiency in over-ground, but there is a benefit in stair walking.