• Title/Summary/Keyword: Artificial dielectric

Search Result 61, Processing Time 0.03 seconds

Five-DOF Polymer Actuator Based on Dielectric Elastomer

  • Kwangmok Jung;Lee, Sangwon;Jongwon Kwak;Kim, Hunmo;Jaedo Nam;Jaewook Jeon;Park, Hyoukryeol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.78.3-78
    • /
    • 2002
  • In this paper, we present a five-DOF actuator based on dielectric elastomer. The actuator is designed for generating five DOFs motions to drive a micro camera steering module and provides all the functions for controlling CCD array such as focusing, pan and tilting. Basic modeling of the actuator is performed, and simulation works and experimental verifications are conducted, too. The camera steering module includes most parts necessary for driving the actuator such as a micro-controller and DC-DC converter, etc. It can be operated with a personal computer using only communication lines without external power supply. A prototype is developed and its performance is experimentally proved. $\textbullet$ artificial muscle, EAP, actuator.

  • PDF

Evaluation on the Electrical Properties of Outdoor Epoxy Resin Insulators under Accelerated Agings (가속열화에 따른 옥외용 epoxy 수지 애자의 전기적특성 평가)

  • Cho, H.G.;Kim, I.S.;Ahn, M.S.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1360-1363
    • /
    • 1994
  • Epoxy resin insulator have good electrical properties (high electric strength, high resistivity, low dielectric loss) in addition to high mechanical strength, small dimensions and design versatility. Polymer insulator, however, are subjected to aging processes, caused by the surrounding atmosphere, which may lead to degradation of their properties. This paper describes the results of a important study on the artificial pollution test, Weather-Ometer properties and rotating wheel dip test of high voltage different aging insulators which are the most important factors for outdoor uses. Also, the objects of this paper are to (a)result of insulator under dry(wet) flashover voltage, (b)artificial pollution test of salt spay, (c)Accelerated aging test of Weather-Ometer, (d) wet and dry flashover voltage under rotating wheel dip test.

  • PDF

A Experimental Investigation on the PD Characteristics depending on the various Artificial Voids In Epoxy Insulator (에폭시 절연체의 보이드 크기에 따른 부분방전 특성연구)

  • Choi, C.K.;Lee, J.S.;Kim, J,T.;Koo, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1853-1855
    • /
    • 2000
  • An experimental investigation has been performed in order to understand the $\Phi$-q-n characteristics related to the PD taking place from the various size of artificial defects inserted in epoxy insulation. In this purpose, PD has been detected simultaneously by two different methods such as commercialized PD detector(TE571) and our detection system using self designed CT type sensor. Under the presence of void in epoxy insulation, PD has been initiated at the voltages between 16kV and 20kV which are much lower than the dielectric strength of epoxy insulation (130kV/mm$\sim$l50kV/mm). And also it is revealed that $\Phi$-q-n characteristics have been observed to be dependent upon the size of the artificial defects. Throughout this work, the on site applicability of the self designed Sensor has also been proved by comparing the results with those from the commercialized PD detector. And more one, considerable basic data regarding the insulation, diagnosis could be provided to understand the presence of the voids possibly inserted into the epoxy insulation system of the power apparatus.

  • PDF

Design of a Transmission Line using Defected Ground Structure and Artificial Dielectric Substrate (결함접지구조와 가유전체 기판구조를 결합한 전송선로의 설계)

  • Kwon, Kyunghoon;Lim, Jongsik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.7
    • /
    • pp.3474-3481
    • /
    • 2013
  • In this work, a new high frequency transmission line structure combined with defected ground structure (DGS) and artificial dielectric substrate (ADS) structure is proposed. DGS patterns give add the additional inductance to transmission lines and results in the increased characteristic impedance for a given line width. To the contrary, ADS presents increased capacitance and reduced line impedance. So both play a role in reducing the length of transmission lines commonly, but in preserving the line impedance complementarily. This means that the length of transmission lines can be reduced furtherly by DGS and ADS without a critical change of line width compared to the cases when one of DGS and ADS is used only. As examples, $35{\sim}100{\Omega}$ transmission lines having DGS and ADS are designed, fabricated, measured, and compared to the simulation results. A good agreement between the simulated and measured line impedances is presented. In addition, the physical lengths of the proposed transmission lines are only 55.4~76.9% of those of the normal microstrip lines for the same electrical lengths.

E. coli Disinfection Using a Multi Plasma Reactor (멀티 플라즈마 반응기를 이용한 E. coli 소독)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Health Sciences
    • /
    • v.39 no.2
    • /
    • pp.187-195
    • /
    • 2013
  • Objectives: For the practical application of the dielectric barrier discharge plasma reactor, a plasma reactor able to manage large volumes of water is needed. This study investigated the possibility of the practical application of a multi-plasma reactor which is a scaled-up version of a single plasma reactor. Methods: The multi-plasma reactor consists of several high-voltage transformers and plasma modules (discharge, ground electrodes and quartz dielectric tubes). The effects of water characteristics such as voltage (30-120 V), air flow rate (1-5 l/min), number of high-voltage transformers and plasma modules, and water quality on Escherichia coli (E. coli) disinfection and decrease of COD and $UV_{254}$ absorbance were investigated. Results: The experimental results showed that at a voltage of over 80 V, most of the E. coli were disinfected within 90 seconds. E. coli inactivation was not affected by the air flow rate. E. coli disinfection in the multiplasma process showed the traditional log-linear form of the disinfection curve. E. coli inactivation performance by transformer 3-Reactor 5 and transformer 3-Reactor 3 were similar. The disinfection performance of the UV process was affected by artificial sewage water. However, the plasma process was less affected by the artificial sewage within the standards for effluent water quality. Conclusions: Disinfection performance with several low voltages and plasma modules of three to five in number applied to the plasma process was higher than that concentrating a small amount of high voltage through a single plasma reactor. Removal of COD, $UV_{254}$ absorbance, and E. coli disinfection with the plasma process were better than with the UV process.

Development of Face Robot Actuated by Artificial Muscle

  • Choi, H.R.;Kwak, J.W.;Chi, H.J.;Jung, K.M.;Hwang, S.H.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1229-1234
    • /
    • 2004
  • Face robots capable of expressing their emotional status, can be adopted as an e cient tool for friendly communication between the human and the machine. In this paper, we present a face robot actuated with arti cial muscle based on dielectric elastomer. By exploiting the properties of polymers, it is possible to actuate the covering skin, and provide human-like expressivity without employing complicated mechanisms. The robot is driven by seven types of actuator modules such as eye, eyebrow, eyelid, brow, cheek, jaw and neck module corresponding to movements of facial muscles. Although they are only part of the whole set of facial motions, our approach is su cient to generate six fundamental facial expressions such as surprise, fear, angry, disgust, sadness, and happiness. Each module communicates with the others via CAN communication protocol and according to the desired emotional expressions, the facial motions are generated by combining the motions of each actuator module. A prototype of the robot has been developed and several experiments have been conducted to validate its feasibility.

  • PDF

Analysis of Space Charge Propagation in a Dielectric liquid Employing Field-Thermal Electron Emission Model and Finite Element Method (유한요소법과 전계-열전자 방출 모델에 의한 절연유체 내 공간전하 전파해석)

  • Lee, Ho-Young;Lee, Se-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.10
    • /
    • pp.2011-2015
    • /
    • 2009
  • In an insulating dielectric liquid such as transformer oil, space charge injection and propagation were analyzed under the Fowler-Nordheim and Richardson-Dushman's thermal emission charge injection conditions for blade-plane electrodes stressed by a step voltage. The governing equations were composed of all five equations such as the Poisson's equation for electric fields, three continuity equations for electrons, negative, and positive ions, and energy balanced equation for temperature distributions. The governing equations for each carrier, the continuity equations, belong to the hyperbolic-type PDE of which the solution has a step change at the space charge front resulting in numerical instabilities. To decrease these instabilities, the governing equations were solved simultaneously by the Finite Element Method (FEM) employing the artificial diffusion scheme as a stabilization technique. Additionally, the terminal current was calculated by using the generalized energy method which is based on the Poynting's theorem, and represents more reliable and stable approach for evaluating discharge current. To verify the proposed method, the discharge phenomena were successfully applied to the blade~plane electrodes, where the radius of blade cap was $50{\mu}m$.

In-situ Process Monitoring Data from 30-Paired Oxide-Nitride Dielectric Stack Deposition for 3D-NAND Memory Fabrication

  • Min Ho Kim;Hyun Ken Park;Sang Jeen Hong
    • Journal of the Semiconductor & Display Technology
    • /
    • v.22 no.4
    • /
    • pp.53-58
    • /
    • 2023
  • The storage capacity of 3D-NAND flash memory has been enhanced by the multi-layer dielectrics. The deposition process has become more challenging due to the tight process margin and the demand for accurate process control. To reduce product costs and ensure successful processes, process diagnosis techniques incorporating artificial intelligence (AI) have been adopted in semiconductor manufacturing. Recently there is a growing interest in process diagnosis, and numerous studies have been conducted in this field. For higher model accuracy, various process and sensor data are required, such as optical emission spectroscopy (OES), quadrupole mass spectrometer (QMS), and equipment control state. Among them, OES is usually used for plasma diagnostic. However, OES data can be distorted by viewport contamination, leading to misunderstandings in plasma diagnosis. This issue is particularly emphasized in multi-dielectric deposition processes, such as oxide and nitride (ON) stack. Thus, it is crucial to understand the potential misunderstandings related to OES data distortion due to viewport contamination. This paper explores the potential for misunderstanding OES data due to data distortion in the ON stack process. It suggests the possibility of excessively evaluating process drift through comparisons with a QMS. This understanding can be utilized to develop diagnostic models and identify the effects of viewport contamination in ON stack processes.

  • PDF

Construction of the evaluating facilities against contamination characteristic for power installation (전력설비에 대한 내오손특성 평가설비 구축)

  • Lee, J.G.;Kim, M.K.;Jeong, J.Y.;Kim, I.S.;Moon, I.W.;Kang, Y.S.;Sung, M.J.
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1851-1853
    • /
    • 2004
  • The important consideration in laboratory designing and construction of the artificial pollution testing facilities including 300kV, 1800kVA AC test system, which enable to test and evaluate the UHV dielectric performance of power insulators up to transmission class, has been dealt in this paper. To evaluate the performance characteristics against contamination for various power installation, especially for the insulators and kinds of bushings, brief investigation and an analysis of test objects and related international codes and standards have been conducted. With the special consideration concerning other matters in designing of these testing facilities have been described with the fixed ratings and references.

  • PDF

Feasibility Study for the Development of a Device for Detecting Pathological Tissues (병리학적 조직 진단장치 개발에 대한 타당성 분석 연구)

  • Ko, Chea-Ok;Park, Min-Young;Pack, Jeong-Ki
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2005.11a
    • /
    • pp.421-424
    • /
    • 2005
  • X-ray is currently most effective method in detecting small malignant breast tumors but has the several problems due to suppressing breast, ionizing radiation and not detecting small cancer. In this paper, a new method is proposed by using dielectric characteristics of pathological tissues and time delay of backscattered response. We have developed a detection algorithm and verified it by numerical simulation and measurement for a prototype system. For a prototype system, we have fabricated experimental model(artificial breast with a cancer) and UWB(ultra-wideband) antenna. The results of the measurement simulation show an excellent detection capability of a cancer tissue. It is found that a good UWB antenna is a key element of such detection system. Further study is ongoing to develop a commercial system.

  • PDF