• 제목/요약/키워드: Artificial Tooth

검색결과 178건 처리시간 0.018초

레진 인공치아의 재부착 방법에 따른 전단결합강도에 관한 연구 (A Study on the Shear Bond Strength of Resin Artificial Tooth Depending on Repair Techniques)

  • 김익중;이종혁;조인호
    • 구강회복응용과학지
    • /
    • 제21권2호
    • /
    • pp.143-151
    • /
    • 2005
  • The purpose of this study was to evaluate the most effective method for repairing the exfoliated resin teeth. The specimens were divided into five groups according to repair method and presence of retention holes. The groups were as follows Group1 : Control group Group2 : Sprinkle method with no retention holes Group3 : Sprinkle method with retention holes Group4 : Flask method with no retention holes Group5 : Flask method with retention holes The results were as follows. 1. According to shear bond strength, the value decreased in the order of group1, group5, group3, group2, group4 and there were significant difference between, each group except between group1 and groups5, group2 and group3, group2 and group4(p < 0.05). 2. According to observations of the exfoliation surface, group2 and 4 showed more failure in the denture base resin and repair resin interface, but in group1, 3 and 5 there were more mixed failures. From the results above, there were no significant difference between repair methods without retention holes. But when comparing groups with retention holes, the flask method showed significantly improved results compared to the sprinkle method. Especially, group5 showed similar results as the control group.

시간경과에 따른 교정용 bracket과 교정선 사이의 마찰력 변화에 관한 연구 (A STUDY ON THE CHANCES OF FRICTIONAL FORCE BETWEEN BRACKET AND ORTHODONTIC WIRE WITH TIME IN ARTIFICIAL SALIVA)

  • 곽춘;김진범;손우성
    • 대한치과교정학회지
    • /
    • 제23권2호
    • /
    • pp.283-294
    • /
    • 1993
  • The friction of orthodontic appliances is recogonized to be detrimental to tooth movement. The purpose of this study was to determine the magnitude of frictional force changes between bracket$(018'\times025'\;solt)$ and orthodontic wires(stainless steel, cobalt-chromium, and $\beta-titanium$, $017'\times0.25'$ rectangular) with time. The wire was secured in the bracket slot with a elastomeric ligature. Frictional forces were measured by universal testing machine. The following conclusions were obtained. 1. The frictional forces under dry condition were greater than those in saliva. 2. The frictional forces produced by cobalt-chromium wire were less than those generated by stainless steel and $\beta-titanium$ wire. 3. The frictional forces increased progressively with time, and the amount of increase on first two weeks was greater than on last two weeks. 4. The change of frictional force under dry condition was greater than in artificial saliva.

  • PDF

불소 함유 교정용 레진 시멘트의 불소 유리 및 법랑질 탈회 저항성에 대한 효과 (The Effect of Orthodontic Resin Cements Containing Fluoride on Fluoride-releasing and the Resistance to Enamel Decalcification)

  • 김명은;강재경;김수화;이민영;이주혜;김형식;김광만
    • 치위생과학회지
    • /
    • 제11권5호
    • /
    • pp.445-453
    • /
    • 2011
  • 본 연구에서는 4종류의 교정용 레진시멘트의 불소 유리량을 측정해 보고 탈회정도를 비교해 본 결과 다음과 같은 결과을 얻었다. 1. 불소 유리량은 불소를 포함한 실험군이 불소를 포함하지 않은 대조군에 비해 통계적으로 유의하게 높은 불소 유리량을 보였다(p<0.05). 2. 누적 불소 유리량은 불소를 포함한 실험군이 불소를 포함하지 않은 대조군에 비해 통계적으로 유의하게 높은 불소 유리량을 보였다(p<0.05). 3. 불소의 유리 양상은 모든 시편에서 실험 첫째 날 하루 동안 가장 많은 양의 불소를 유리하였다(p<0.05). 4. 탈회 후의 ${\Delta}F$값과 ${\Delta}Q$값의 절대값은 군 간에 통계적으로 유의하지 않았으나, 대조군에 비해 작았다(p<0.05). 5. 탈회실험 전 후의 ${\Delta}F$값과 ${\Delta}Q$값의 변화량의 절대값은 실험군이 대조군에 비해 작았다(p<0.05). 이상의 결과을 통해 불소를 포함한 교정용 레진 시멘트는 일정기간 불소를 유리하고, 법랑질 탈회를 예방함으로써 교정 치료 시 발생할 수 있는 초기 우식발생을 예방할 수 있다고 사료된다.

디지털방사선촬영술을 이용한 인접면 치아우식증 진단에 관한 실험적 연구 (A STUDY ON THE ARTIFICIAL INTERPROXIMAL CARIES DETECTION WITH THE DIGITAL RADIOGRAPHY)

  • 권기정;황의환;이상래
    • 치과방사선
    • /
    • 제24권1호
    • /
    • pp.85-94
    • /
    • 1994
  • The purposes of this study were clinical comparison and evaluation between digital radiography and conventional radiography for the detection of artificial interproximal caries. Four freshly extracted, unrestored posterior teeth were obtained and caries was simulated by drilling semicircled defects with variable size at the interproximal surface of each tooth. The experiments were performed with IBM-PC/32 bit-DX compatible, video camera(VM-S8200, Hitachi Co., Japan), and color monitor(Multisync 3D, NEC, Japan). Sylvia Image Capture Board for the ADC(analog to digital converter) was used, and spatial resolution was 512 × 480 with 256 gray levels. The obtained results were as follows: 1. At the condition of under exposure, the radiographs were superior to the digital images in readability. Also, as the size of the artificial lesion was increased, readability of the radiographs was elevated. 2. The digital images were superior to the radiographs in readability especially under over exsposure. 3. As the exposure time and size of lesion was increased, the gray level of region of interest of the digital image was decreased proportionally. 4. As the F-value of average gray level of region of interest at individual exposure time and size of lesion, gray level of the all lesion sizes was decreased in comparison with that of the normal enamel.

  • PDF

심한 치조골 흡수로 인해 편평한 치조제를 보이는 완전 무치악 환자에서 설측 교두 교합을 이용한 의치 수복 증례 (Complete denture treatment using lingualized occlusion scheme at the edentulous patient with severely absorbed flat residual ridges: a case report)

  • 최범식;이준석
    • 구강회복응용과학지
    • /
    • 제33권3호
    • /
    • pp.207-215
    • /
    • 2017
  • 총의치 치료에서는 지지, 유지, 안정, 교합, 심미 등 고려할 요소가 많으나 치조골 흡수가 심한 경우, 해당 요인을 갖추기 어렵다. 해부학적 치아를 사용할 경우 좋은 저작효율과 심미성을 기대할 수 있으나, 흡수된 치조골에서는 안정이 저하될 수 있으며 비해부학적 치아는 이와 반대의 효과를 나타낸다. 이에 치아를 혼용하는 설측 교두 교합이 제시되었다. 설측 교두 교합에서 상, 하악 협측 교두는 중심위, 측방위에서 접촉되지 않고 교합접촉위치가 설측화 또는 중심화되어 의치의 안정성이 증대될 수 있다. 본 증례는 상하 치조제의 흡수가 진행되어, 상악에서 편평한 치조제를 보이는 경우로, 설측 교두 교합을 이용한 총의치를 이용하여 치료함으로써 의치의 안정성과 환자의 만족도를 높였기에 이를 보고하는 바이다.

Influence of the preparation design and artificial aging on the fracture resistance of monolithic zirconia crowns

  • Mitov, Gergo;Anastassova-Yoshida, Yana;Nothdurft, Frank Phillip;See, Constantin von;Pospiech, Peter
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권1호
    • /
    • pp.30-36
    • /
    • 2016
  • PURPOSE. The aim of this study was to evaluate the fracture resistance and fracture behavior of monolithic zirconia crowns in accordance with the preparation design and aging simulation method. MATERIALS AND METHODS. An upper first molar was prepared sequentially with three different preparation designs: shoulderless preparation, 0.4 mm chamfer and 0.8 mm chamfer preparation. For each preparation design, 30 monolithic zirconia crowns were fabricated. After cementation on Cr-Co alloy dies, the following artificial aging procedures were performed: (1) thermal cycling and mechanical loading (TCML): 5000 cycles of thermal cycling $5^{\circ}C-55^{\circ}C$ and chewing simulation (1,200,000 cycles, 50 N); (2) Low Temperature Degradation simulation (LTD): autoclave treatment at $137^{\circ}C$, 2 bar for 3 hours and chewing simulation; and (3) no pre-treatment (control group). After artificial aging, the crowns were loaded until fracture. RESULTS. The mean values of fracture resistance varied between 3414 N (LTD; 0.8 mm chamfer preparation) and 5712 N (control group; shoulderless preparation). Two-way ANOVA analysis showed a significantly higher fracture loads for the shoulderless preparation, whereas no difference was found between the chamfer preparations. In contrast to TCML, after LTD simulation the fracture strength of monolithic zirconia crowns decreased significantly. CONCLUSION. The monolithic crowns tested in this study showed generally high fracture load values. Preparation design and LTD simulation had a significant influence on the fracture strength of monolithic zirconia crowns.

상악전치 후방 견인시 견인 loop후방에 부여한 gable bend 양에 따른 치아이동 양상에 관한 연구 (A study on the effect of the magnitude of the gable bends on the tooth movement pattern during on-masse space closure in the maxillary dentition)

  • 전윤식;노준;정상혁;김희정
    • 대한치과교정학회지
    • /
    • 제34권1호
    • /
    • pp.33-45
    • /
    • 2004
  • 제 1소구치가 발치된 증례에서 bull loop를 견치 직후방에 제작한 후 gable bend를 어느 정도 부여할 때 전치부의 효과적인 치축조절과 후방 이동량을 극대화 할 수 있는지를 입체적으로 확인하는 것이 본 연구의 목적이다. 제 1소구치가 제거된 상악우측 인공 치조골부에 중절치부터 제 2대구치까지 실험용 치아들을 식립하였다. 그 후 bull-loop가 형성된 반쪽 호선에 $10^{\circ},\;20^{\circ},\;30^{\circ}$의 gable bend를 부여한 후 3전치를 후방 견인하여 발치공간을 폐쇄시켰고 이러한 실험과정을 각 군마다 3회씩 반복 실험하였다. 발치공간이 폐쇄된 후 실험전, 후의 교합방사선 사진상에 촬영된 전치부와 구치부의 시상면과 교합면 상에서의 각 군별 치아이동 양상을 일요인 분산분석(ANOVA)과 Scheffe 검정으로 평가한 결과 아래와 같은 결론을 얻었다. 1. Gable bend의 양이 증가할수록 전치부의 치축은 치체이동 양상을 보였으며 후방 이동량도 증가하였다. 2. Gablebend의 양이 증가할수록 구치부의 전방 이동량은 감소하였으나 수직적 압하량 및 협측 이동량은 증가하였다(p<0.001). 3. 발치공간에 인접한 견치의 원심회전과 제 2소구치의 근심회전에 의해 악궁의 조화가 이루어졌다(p<0.001).

풍력발전기 모사 시스템에서의 균열 결함 진단에 대한 연구 (A Study on Crack Fault Diagnosis of Wind Turbine Simulation System)

  • 배근호;박종원;김봉기;최병오
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제14권4호
    • /
    • pp.208-212
    • /
    • 2014
  • An experimental gear-box was set-up to simulate the real situation of the wind-turbine. Artificial cracks of different sizes were machined into the gear. Vibration signals were acquired to diagnose the different crack fault conditions. Time-domain features such as root mean square, variance, kurtosis, normalized 6th central moments were used to capture the characteristics of different crack conditions. Normal condition, 1 mm crack condition, 2mm crack condition, 6mm crack condition, and tooth fault condition were compared using ANFIS and DAG-SVM methods, and three different DAG-SVM models were compared. High-pass filtering improved the success rates remarkably in the case of DAG-SVM.

치관수복물의 형태와 치은반응에 관한 연구 (A Study on Corwn Contour and Gingival Response)

  • 양홍서;장완식
    • 대한치과의사협회지
    • /
    • 제21권5호통권168호
    • /
    • pp.415-423
    • /
    • 1983
  • A total of 202 full coverage crowns from 31 patients was investigated to find out the relationships between crown contour and gingival response. Every experimental crown has its contralateral natural tooth for its control group. Gingival Index and buccolingual width of the crowns were measured on both experimental and control group. Following conclusions were obtained from the study. 1. Most of the crown restorations were overcontoured and the increments were servere at cervical and height of contour area. 2. Height of contour and contact point of the restored crown were located near cervical area. Besides, most crowns had narrow embrasure with wide contact area. 3. Gingival Index around crown restorations was significantly larger than that of control group. 4. the interrelationship between Gingival Index and restored material or restored period was not verified at 5% significant level. 5. When grouping the artificial crowns into overcontoured, normal contoured, and undercontoured group by their width increment, the gingival inflammation was the severest in the overcontoured group and the mildest in the undercontoured group.

  • PDF

기계 결함 시뮬레이터(MFS)를 이용한 결함 신호 분석 (Fault Detection Analysis by Using a Machinery Fault Simulator)

  • 배태한;장석동;송철기
    • 한국자동차공학회논문집
    • /
    • 제13권1호
    • /
    • pp.126-131
    • /
    • 2005
  • This paper presents experimental results by using the machinery fault simulator which is monitoring its conditions with an acceleration signal. Components of the machinery, for example, motor, belt pulley, belt, bearing, and gear, with artificial defects were used for the experiment.