• 제목/요약/키워드: Artificial Disc

검색결과 72건 처리시간 0.033초

The effect of two artificial salivas on the adhesion of Candida albicans to heat-polymerized acrylic resin

  • Oncul, Burcin;Karakis, Duygu;Al, Funda Dogruman
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권2호
    • /
    • pp.93-97
    • /
    • 2015
  • PURPOSE. Xerostomia can diminish the quality of life, leads to changes in normal chemical composition of saliva and oral microbiata, and increases the risk for opportunistic infections, such as Candida albicans. Various artificial salivas have been considered for patients with xerostomia. However, the knowledge on the antifungal and antiadhesive activity of artificial saliva substitutes is limited. The aim of the present study was to evaluate influence of two artificial salivas on the adhesion of Candida albicans to the polymethylmethacrylate disc specimens. MATERIALS AND METHODS. Two commercial artificial salivas (Saliva Orthana and Biotene Oral Balance Gel) were selected. 45 polymethylmethacrylate disc specimens were prepared and randomly allocated into 3 groups; Saliva Orthana, Biotene-Oral Balance gel and distilled water. Specimens were stored in the artificial saliva or in the sterile distilled water for 60 minutes at $37^{\circ}C$. Then they were exposed to yeast suspensions including Candida albicans. Yeast cells were counted using ${\times}40$ magnification under a light microscope and data were analysed. RESULTS. Analysis of data indicated statistically significant difference in adhesion of Candida albicans among all experimental groups (P=.000). Findings indicated that Saliva Orthana had higher adhesion scores than the Biotene Oral Balance gel and distilled water (P<.05). CONCLUSION. In comparison of Saliva Orthana, the use of Biotene Oral Balance Gel including lysozyme, lactoferrin and peroxidase may be an appropriate treatment method to prevent of adhesion of Candida albicans and related infections in patients with xerostomia.

Neural Network Approach to Automated Condition Classification of a Check Valve by Acoustic Emission Signals

  • Lee, Min-Rae;Lee, Joon-Hyun;Song, Bong-Min
    • 비파괴검사학회지
    • /
    • 제27권6호
    • /
    • pp.509-519
    • /
    • 2007
  • This paper presents new techniques under development for monitoring the health and vibration of the active components in nuclear power plants, The purpose of this study is to develop an automated system for condition classification of a check valve one of the components being used extensively in a safety system of a nuclear power plant. Acoustic emission testing for a check valve under controlled flow loop conditions was performed to detect and evaluate disc movement for valve failure such as wear and leakage due to foreign object interference in a check valve, It is clearly demonstrated that the evaluation of different types of failure types such as disc wear and check valve leakage were successful by systematically analyzing the characteristics of various AE parameters, It is also shown that the leak size can be determined with an artificial neural network.

Injectable Hydrogel을 이용한 인공 Nucleus Pulposus의 제조 (Injectable Hydrogel as an Artificial Nucleus Pulposus in a Degenerative Intervertebral Disc)

  • Park, Jin-Hyun
    • 한국섬유공학회:학술대회논문집
    • /
    • 한국섬유공학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.13-16
    • /
    • 2002
  • The Intervertebral disc is a composite structure made up of the nucleus pulposus (NP) core surrounded by the multi-layered fibers of the annulus fibrosis (AF)[1]. Water is drawn into the NP by the presence of hydrophilic proteins called proteoglycans [2]. The AF, with successive layers oriented in alternating directions, surrounds the NP. These layers are placed under tension as the NP absorbs water and swells [3]. (omitted)

  • PDF

Rare Intractable Cervicalgia Related to Exaggerated Disc Height Distraction : Report of Two Cases and Literature Review

  • Choi, Man Kyu;Kim, Sung Bum;Lee, Jun Ho
    • Journal of Korean Neurosurgical Society
    • /
    • 제61권4호
    • /
    • pp.530-536
    • /
    • 2018
  • We present two cases of unexpected postoperative intractable cervicalgia due to over-sized implant insertion during simple anterior cervical decompression and fusion (ACDF) or artificial disc replacement (ADR). These patients experienced severe cervicalgia mostly related to their neck motion even after standard cervical operations. In both cases, the restored disc heights after the operations were prominently greater than the preoperative disc heights. The patients had not responded to any of the conservative treatments, and unloading of these excessively distracted segments through ultimate revision surgery led to dramatic pain relief. This report emphasizes the increase in distractional forces that takes place after a standard ACDF or ADR, as well as the importance of a proper sized implant. It also includes the reviews of other biomechanical or clinical reports dealing with this issue, thereby cautioning the surgeons not to disregard these factors, which might have an adverse effect in patients with cervicalgia even after radiographically successful cervical procedures.

Potential Probiotic Properties of Lactic Acid Bacteria Isolated from Kimchi

  • Kim, Seon-Jae
    • Food Science and Biotechnology
    • /
    • 제14권4호
    • /
    • pp.547-550
    • /
    • 2005
  • Fourteen out of 87 strains of lactic acid bacteria isolated tram Kimchi were found to be resistant against the action of artificial gastric and bile juices. In particular, lactobacilli KM 3, 7, 28, and 37 showed strong resistance and their viable cell counts at the initial stage remained the same even after 3 hours of cultivation in an artificial gastric juice. However, the survival rates of KM 14, 28, and 64 were found to be significantly enhanced in artificial bile juice. Based on the paper disc method, it was evident that isolated lactic acid bacteria showed antibacterial effect against Listeria monocytogenes, Escherichia coli, Bacillus subtilis, Staphylococcus aureus, Vibrio vulnificus, and Salmonella typhimurium. The isolated lactic acid bacteria were identified as Lactobacillus plantarum and Leuconostoc mesenteroides.

터빈 로타 디스크의 초음파탐상을 위한 초음파탐촉자의 지향성 및 탐상범위 (Evaluation of Near/Far Field and Directivity of Ultrasonic Transducer for Turbine Rotor Disc)

  • 원순호;장홍근;조경식;이종오;이종규
    • 비파괴검사학회지
    • /
    • 제18권3호
    • /
    • pp.163-171
    • /
    • 1998
  • 터빈 디스크에서 발생하는 결함에 대한 초음파탐상기술을 확립하기 위하여 초음파탐촉자의 근/원거리 음장 및 지향성에 대하여 연구하였다. 영광원자력 LP터빈 No. 6 디스크와 동일하게 대비시험편을 제작하였고 터빈로타 디스크의 초음파탐상에 사용된 5MHz PZT 압전탐촉자의 직경에 따른 근/원거리 음장 및 지향성을 계산하고 실험을 통하여 확인하였다. 쐐기와 디스크로 구성된 실험계에서 bore면에 깊이 2mm 및 4mm 인공결함을 지닌 시편과 직경이 0.5inch이고 중심 주파수 5MHz인 초음파탐촉자를 이용하여 계산 및 실험을 수행하였고 그 결과를 비교, 분석하였다. Keyway 영역에 발생한 결함의 탐상능력을 평가하기 위하여 내부의 53mm 및 75mm 지점에 초음파탐촉자를 두고서 $45^{\circ}$$90^{\circ}$ 경사각 초음파탐촉자를 설치한 경우를 가정하여 결함의 탐상영역을 결정하였다.

  • PDF

Comparative Analysis of Cervical Arthroplasty Using Mobi-$C^{(R)}$ and Anterior Cervical Discectomy and Husion Using the $Solis^{(R)}$-Cage

  • Park, Jin-Hoon;Roh, Kwang-Ho;Cho, Ji-Young;Ra, Young-Shin;Rhim, Seung-Chul;Noh, Sung-Woo
    • Journal of Korean Neurosurgical Society
    • /
    • 제44권4호
    • /
    • pp.217-221
    • /
    • 2008
  • Objective : Although anterior cervical discectomy and fusion (ACDF) is the standard treatment for degenerative cervical disc disease, concerns regarding adjacent level degeneration and loss of motion have suggested that arthroplasty may be a better alternative. We have compared clinical and radiological results in patients with cervical disc herniations treated with arthroplasty and ACDF. Methods : We evaluated 53 patients treated for cervical disc herniations with radiculopathy, 21 of whom underwent arthroplasty and 32 of whom underwent ACDF. Clinical results included the Visual Analogue Scale (VAS) score for upper extremity radiculopathy, neck disability index (NDI), duration of hospital stay and convalescence time. All patients were assessed radiologically by measuring cervical lordosis, segmental lordosis and segmental range-of-movement (ROM) of operated and adjacent disc levels. Results : Mean hospital stay (5.62 vs. 6.26 days, p<0.05) and interval between surgery and return to work (1.10 vs 2.92 weeks, p<0.05) were significantly shorter in the arthroplasty than in the fusion group. Mean NDI and extremity VAS score improved after 12 months in both groups. Although it was not significant, segmental ROM of adjacent levels was higher in the fusion group than in the arthroplasty group. And, segmental motion of operated levels in arthroplasty group maintained more than preoperative value at last follow up. Conclusion : Although clinical results were similar in the two groups, postoperative recovery was significantly shorter in the arthroplasty group. Although it was not significant, ROM of adjacent segments was less in the arthroplasty group. Motion of operated levels in arthroplasty group was preserved at last follow up.