• Title/Summary/Keyword: Artifacts

Search Result 1,681, Processing Time 0.025 seconds

Panoramic Image Synthesis Using Flash and No-Flash Image Pairs (Flash 영상과 No-flash 영상을 이용한 파노라마 영상합성)

  • Ye, Sang-Myoung;Park, Rae-Hong
    • Proceedings of the IEEK Conference
    • /
    • 2007.07a
    • /
    • pp.355-356
    • /
    • 2007
  • This paper proposes a new panoramic image synthesis method using flash and no-flash image pairs, which reduces undesirable artifacts. Generally, in panoramic images, it is difficult to determine to use a flash in indoor environment. A flash image has unwanted artifacts such as hot spots and tunnel effect whereas a no-flash image also has artifacts like glass reflection. We derive cross projection tensors using flash and no-flash image pairs and transform the gradient field of a no-flash image using them. The image reconstructed from the modified gradient provides enhanced results, which are applied to synthesis of panoramic images. The proposed method can provide a better panoramic image than the conventional method. Experimental results show the effectiveness of the proposed method.

  • PDF

Reduction of the Blocking Artifact in Block-Based Image Coding System (블록 기반 이미지 코딩 시스템에서 블록화 현상 감소 기법)

  • Yoo Kyeong-Jong;Seo Yeong-Geon;Lee Bu-Kwon
    • Journal of Digital Contents Society
    • /
    • v.5 no.1
    • /
    • pp.48-53
    • /
    • 2004
  • Due to NxN block coding blocking artifacts are exhibited by block-based DCT coding images, primarily at low bit rates. In this letter, we propose the new technique that reduce the blocking artifacts pixels in such images. In the case of combining with list block reconstruction techniques, our algorithm can be also used to improve image qiality. And, the performance of the proposed algorithm is demonstrated experimentally.

  • PDF

Three-Dimensional Digital-Mold Modeling and Sand-Printing for Replication of Bronze Mirror

  • Jo, Young Hoon;Lee, Jungmin
    • Journal of Conservation Science
    • /
    • v.37 no.1
    • /
    • pp.25-33
    • /
    • 2021
  • To extend the application of digital technology to the replication of artifacts, meticulous details of the process and the diversity of three-dimensional (3D) printing output materials need to be supplemented. Thus, in this study, a bronze mirror with Hwangbichangcheon inscription was digitalized by 3D scanning, converted into a voxel model, and virtual conservation treatment was performed using a haptic device. Furthermore, the digital mold of the bronze mirror completed by Boolean modeling was printed using a 3D sand-printer. Such contactless replication based on digital technology reflects the stability, precision, expressivity, collectivity, durability, and economic feasibility of artifacts. Its application can be further extended to cultural products as well as such areas as education, exhibition, and research. It is expected to be in high demand for metal artifacts that require casting. If empirical studies through experimental research on casting are supplemented in the future, it could extend the application of digital technology-based contactless replication methods.

Image Restoration Method using Denoising CNN (잡음제거 합성곱 신경망을 이용한 이미지 복원방법)

  • Kim, Seonjae;Lee, Jeongho;Lee, Suk-Hwan;Jun, Dongsan
    • Journal of Korea Multimedia Society
    • /
    • v.25 no.1
    • /
    • pp.29-38
    • /
    • 2022
  • Although image compression is one of the essential technologies to transmit image data on a variety of surveillance and mobile healthcare applications, it causes unnecessary compression artifacts such as blocking and ringing artifacts by the lossy compression in the limited network bandwidth. Recently, image restoration methods using convolutional neural network (CNN) show the significant improvement of image quality from the compressed images. In this paper, we propose Image Denoising Convolutional Neural Networks (IDCNN) to reduce the compression artifacts for the purpose of improving the performance of object classification. In order to evaluate the classification accuracy, we used the ImageNet test dataset consisting of 50,000 natural images and measured the classification performance in terms of Top-1 and Top-5 accuracy. Experimental results show that the proposed IDCNN can improve Top-1 and Top-5 accuracy as high as 2.46% and 2.42%, respectively.

A Study on the Method for Removing the Paraffin used on Iron Artifacts as Surface Coating Agent - As Focused on the Iron Artifacts Owned by the Kyunghee University Central Museum - (철제유물 표면코팅제로 사용된 파라핀 제거방법에 관한 연구 - 경희대학교박물관 소장 철제유물을 중심으로 -)

  • Kang, Seokin;Wi, Koangchul;Lee, Hoyeon;Lim, Seongjin
    • Conservation Science in Museum
    • /
    • v.13
    • /
    • pp.23-31
    • /
    • 2012
  • The object artifacts of this study are the iron artifacts owned by the Kyunghee University Central Museum. The surfaces of the iron artifacts are opaque due to the coated materials which are presumed to be paraffin or bee's wax while they are plate-shaped and exist in thickly exfoliated condition caused by severe corrosion developed on the overall surfaces. Therefore, in order to remove the coated materials away from the surfaces of the artifacts rather safely, reversibility tests have been carried out and the conservation treatment was performed upon the basis of and in application of the experimental results. The study methodologies are that: first, the FT-IR analysis was carried out to determine the ingredients of the coating-treated material on the surface; second, by applying various kinds of organic solvents, the kinds of agents that allow the artifact's surface-coating material to be reversible have been identified through experiments; third, the most suitable agent for removing coating material was selected and applied to the real artifacts on the basis of the results of the reversibility tests. Results from the study: first, as a result of the FT-IR analysis, the coating agent used on the artifacts was identified to be of the same ingredients as those of paraffin; second, among organic solvents, xylene, toluene, trichloroethylene and methyl alcohol were identified to be usable for dissolving paraffin whereas toluene was judged to be the most suitable for removing the coating agent; third, when applying the selected agents on the real artifacts, due to the fact that removing the whole paraffin might cause the artifact to disintegrate, the paraffin of only the part that covered the surfaces opaquely was removed using cotton swab or gauze, thus completing the conservation treatment.

Application Study of $CO_2$ Snow Cleaning for Cleaning of Foreign Matter and Corrosion Products on Iron Artifacts ($CO_2$ Snow Cleaning 적용 철제유물 표면 이물질 제거 연구)

  • Lee, Eun-Ji;Cho, Nam-Chul;Lee, Jong-Myong;Yu, Jae-Eun
    • Journal of Conservation Science
    • /
    • v.27 no.3
    • /
    • pp.333-344
    • /
    • 2011
  • Cleaning of foreign matter and corrosion products on surface among conservation treatment of iron artifacts is an important part for looking up a original form. The sand blaster is the most popular equipment when it removes the foreign matter and corrosion products on iron artifacts surface. Current foreign matter and corrosion products equipment, which mostly uses, is sand blaster. Glass dust which sprayed from sand blaster is harmful and causing environmental pollution. In order to solve these problems, we investigated the $CO_2$ snow cleaning that use a eco-friendly equipment to apply for cleaning foreign matter and corrosion products on surface of iron artifacts. It examined by using sand blaster and $CO_2$ snow cleaning to aged steel coupon and iron artifacts. In case of aged steel coupon, the result showed that the sand blaster and $CO_2$ snow cleaning methods were similar to the degrees of cleaning foreign matter and corrosion products, through surface roughness, color measurement and SEM. $CO_2$ snow cleaning applied to aged steel coupons weren't worn out the surface in comparison with sand blaster by SEM. When applied to the iron artifacts, power nozzle of the $CO_2$ snow cleaning was an excellent cleaning effect that surface wern't worn out in comparison with sand blaster. And, it showed that internal structure change of metal was no found before and after cleaning by X-ray radiography. Consequently, we confirmed that cleaning of the sand blaster and power nozzle of $CO_2$ snow cleaning were similar to the effect. But, it's very careful to use this method because of high outlet pressure of power nozzle for applying to the iron artifacts. As a result of experiments, it could be found that the cleaning methods should be selected depending on internal state of the artifacts.

A Comparative Analysis According to a Presence or Absence of Metal Artifacts when a Dose Change and QAC Technique are Applied in PET/CT Tests (PET/CT 검사에서 선량변화와 QAC기법 적용 시 Metal Artifact 유무에 따른 SUV 비교분석)

  • Yun, Sun-Hee;Kim, Yang-Jung;Kang, Young-Jik;Park, Su-Young;Kim, Ho-Sin;Ryu, Hyoung-Ki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.51-56
    • /
    • 2015
  • Purpose As medical radiation exposures on patients are being social issues an interest in a relief of radiation exposures on patients is increasing. Further, there are many cases where some patients among who are getting PET/CT tests choose to get implanted with metal artifacts in their bodies. This study is to find out effects of presence or absence of metal artifacts when dose change or CT attenuation correction for the relief of radiation exposures are applied using phantoms through changes in standard uptake value (SUV). Materials and Methods GE company's Discovery 710 machine was used for PET/CT test equipments. We used NEMA IEC body phantoms. We also used screw and mesh cage made of titanium which are used in real clinical processes for the metal artifacts. Two experiments were conducted: One is to test and measure repeatedly about SUV about differences in CT attenuation corrections according to dose changes and another is to do the same procedure for SUV about the presence and absence of the metal artifacts. We injected $^{18}F-FDG$ into NEMA IEC body phantoms with a TBR ratio of 4:1 and then put the metal material into the transformation phantoms. Once a scanning for the metal artifacts was done we eliminated the metal artifacts and went on non-metal artifacts. For the each two experiments, we scanned repeatedly with CT kVp (140, 120, 100, 80) and mA (120, 80, 40, 20, 10) for an experimental condition. For PET, we reconstructed each with standard AC (STD) technique and quantitation achieved cnsistently QAC) technique among CT attenuation correction methods. We conducted a comparative analysis on measured average values and variations which were measured through repeated measure of SUV of region 1, 2, 3 spheres for each conditions of non-metal /metal scan. Results For each kVp, 120, 80, 40 (mA) of non/metal (screw, mesh cage) showed low frequency of fluctuation rates of above 2%. In 20, 10 mA above 2% of fluctuation rates appeared in high frequency. Also, when we compared the fluctuation rates of STD and QAC techniques in non/metal (screw, mesh cage) tests QAC technique showed about 1-10% of differences for each conditions compared to STD technique. In addition, metal types did not have significant effects on fluctuation rates. Conclusion We confirmed that SUV fluctuation rates for both STD and QAC techniques increase as dosage is lower. We also found that the SUV of PET data was maintained steadily in a low dosage for QAC technique when compared with STD technique. Hence, when the low dosage is used for the relief of radiation exposures on patients QAC technique may be exploited helpfully and this could be applied in the same way for patients with metal artifacts implanted in their bodies.

  • PDF

Magnitude of beam-hardening artifacts produced by gutta-percha and metal posts on cone-beam computed tomography with varying tube current

  • Gaeta-Araujo, Hugo;Nascimento, Eduarda Helena Leandro;Fontenele, Rocharles Cavalcante;Mancini, Arthur Xavier Maseti;Freitas, Deborah Queiroz;Oliveira-Santos, Christiano
    • Imaging Science in Dentistry
    • /
    • v.50 no.1
    • /
    • pp.1-7
    • /
    • 2020
  • Purpose: This study was performed to evaluate the magnitude of artifacts produced by gutta-percha and metal posts on cone-beam computed tomography (CBCT) scans obtained with different tube currents and with or without metal artifact reduction (MAR). Materials and Methods: A tooth was inserted in a dry human mandible socket, and CBCT scans were acquired after root canal instrumentation, root canal filling, and metal post placement with various tube currents with and without MAR activation. The artifact magnitude was assessed by the standard deviation (SD) of gray values and the contrast-to-noise ratio (CNR) at the various distances from the tooth. Data were compared using multi-way analysis of variance. Results: At all distances, a current of 4 mA was associated with a higher SD and a lower CNR than 8 mA or 10 mA (P<0.05). For the metal posts without MAR, the artifact magnitude as assessed by SD was greatest at 1.5 cm or less (P<0.05). When MAR was applied, SD values for distances 1.5 cm or closer to the tooth were reduced (P<0.05). MAR usage did not influence the magnitude of artifacts in the control and gutta-percha groups(P>0.05). Conclusion: Increasing the tube current from 4 mA to 8 mA may reduce the magnitude of artifacts from metal posts. The magnitude of artifacts arising from metal posts was significantly higher at distances of 1.5 cm or less than at greater distances. MAR usage improved image quality near the metal post, but had no significant influence farther than 1.5 cm from the tooth.

Motion Artifacts reduction from the PPG based on the Improved PMAF for the U-Healthcare System (U-헬스케어 시스템을 위한 개선된 PMAF 기반의 PPG 신호의 동잡음 제거)

  • Lee, Han-Wook;Lee, Ju-Won;Jeong, Won-Geun;Jun, Jae-Chul;Lee, Gun-Ki
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.45 no.5
    • /
    • pp.28-34
    • /
    • 2008
  • The real-time biomedical signal monitoring is a very important factor to realize the ubiquitous healthcare environment. Most of these devices for monitoring the biomedical information get the PPG signal from the user, and these signals are utilized for monitoring their health. It is inconvenient to get the PPG because the user should wear the finger probe with his finger for measuring the PPG signal. Also it is difficult to get the PPG correctly, because of the motion artifacts from the movement of the user. In this paper, we develop the watch type biomedical signal monitoring system without the finger probe, and propose the new algorithm for reducing the motion artifacts from the PPG signal. We designed the system which gets the PPG from the sensor on the wrist band strip. As compared with the finger probe type, this system we proposed is more affected by the motion artifacts. So to filter this motion artifacts, we propose the new method; the improved PMAF(Periodic Moving Average Filter) method.

A Study on Corrosion Inhibitors for applying to Iron objects (철제유물의 부식억제를 위한 부식억제제에 관한 연구)

  • Kim, Hye Sun;Hur, Yoon Hyun;Kim, Soo Ki
    • Journal of Conservation Science
    • /
    • v.30 no.1
    • /
    • pp.1-11
    • /
    • 2014
  • Stabilization of iron artifacts is focused on desalination than corrosion inhibitors. However artifacts are not condition of desalination treatment must be applied to corrosion inhibitors. But iron artifacts is not representative of inhibitors which drug is most effective qualities have not been identified. Therefore in this study validates the effectiveness of existing inhibitors and its purpose is to suggest corrosion inhibitors for iron artifacts. In this study, Comparative experiment of corrosion inhibitors is selected BTA, DAN and MEA, TEA. This study was studied using Corrosion resistance test, Contact angle, XPS. As a result, all the samples treated with corrosion inhibitors was formed hydrophobic coating and was rising corrosion resistance. Also, the concentration of corrosion inhibitors was 3% better than 0.3%. BTA in the XPS experiment, the corrosive material to block the CH bond of the peak concentration was highly. This is considered corrosion potential is very high to see out the effect in the polarization experiment. Ethanolamine was superior to the MEA rather than in the TEA. MEA is likely to be appropriate in an outdoor iron artifacts seem to be suitable as corrosion inhibitors.