• Title/Summary/Keyword: Arthrometer

Search Result 74, Processing Time 0.019 seconds

The Results of Primary Repair in Acute Injuries of the Posterior Cruciate Ligament (후방 십자 인대 급성 손상에서 일차 복원술의 결과)

  • Lee, Dong-Chul;Baek, Seung-Hee
    • Journal of Yeungnam Medical Science
    • /
    • v.18 no.1
    • /
    • pp.101-111
    • /
    • 2001
  • Background: We analyze the functional evaluation, posterior stability after surgery of acute injuries in the femoral detachment and tibial avulsion fracture of posterior cruciate ligament. Materials and Methods: Twenty two patients who underwent primary repair were followed more than one year after operation (mean follow-up 33.7 months). The patients were evaluated with KT 2000 arthrometer and posterior stress test for posterior stability. Lysholm knee score was used for knee function. Results: Lysholm score revealed 85.3 in femoral detachment group and 91.1 in tibial avulsion fracture group (P<0.05). Posterior displacement of the posterior stress test showed 17.2 mm at initial injury and 8.6 mm at last follow up in femoral detachment group, 16.8 mm at initial injury and 7.1 mm at last follow up in tibial avulsion fracture group. There revealed the tendency of the improved posterior stability of the tibial avulsion group compared with femoral detachment group, but there showed no statistical significance in KT 2000 arthrometer and posterior stress x-ray. Conclusion: Functional results of tibial avulsion fracture group revealed the better outcome compared with femoral detachment group, but the degree of posterior stability in tibial avulsion fracture group showed no statistical significance in posterior stability.

  • PDF

Double Bundle Posterior Cruciate Ligament Reconstruction by the Tibial Inlay Method - Technical note - (경골 내재술식을 이용한 이중 다발 후방 십자 인대 재건술 - 수술 기법 -)

  • Lee, Yeong-Hyun;Nam, Il-Hyun;Moon, Gi-Hyuk;Ahn, Gil-Yeong;Lee, Sang-Chung
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.2
    • /
    • pp.139-146
    • /
    • 2008
  • Purpose: The purpose of this study is to introduce the double bundle posterior cruciate ligament(PCL) reconstruction using Achilles allograft by the tibial inlay method and evaluate the clinical results of 11 cases who had PCL reconstruction using this method and were followed for more than 2 years after surgery. Materials and Methods: Our series consists of 11 cases of PCL reconstruction due to chronic posterior instability of knee and acute PCL rupture. The clinical results were assessed using the IKDC(International Knee Documentation Committee) scoring system, posterior stress radiographs and the maximum posterior displacement using a KT-1000TM arthrometer. Results: The average preoperative posterior displacement in 90 degree flexion stress radiograph was measured 13.4 mm and in 10 degree flexion the average posterior displacement using the KT-1000TM arthrometer was measured 11.4 mm. Postoperatively the 13.4 mm reduced to 4.4 mm and the 11.4 mm reduced to 3.9 mm. According to IKDC scoring system, 9 cases(81.8%) were satisfied. One case showed limitation of flexion with mild stiffness in the knee and another one case was not improved the posterior instability sufficiently and no complication of allograft was noticed. Conclusion: The double bundle PCL reconstruction using Achilles allograft by the tibial inlay method is a useful method for acute PCL rupture and chronic posterior instability of the knee including failed PCL reconstruction, because it will also make the posterior stability in the extension and 90 degree flexion position, and avoid the grafted tendon abrasion by acute turn of tibial tunnel.

  • PDF

Comparison Study of Anterior Cruciate Ligament Reconstruction Using Bone-Patella Tendon-Bone Autograft and Achilles Tendon Allograft (이식건에 따른 관절경하 전방 십자 인대 재건술의 비교 -자가 골-슬개건-골과 동종 아킬레스건의 비교-)

  • Seo, Joong-Bae;Jung, Hong-Geun;Kim, Myung-Ho;Park, Hee-Gon;Yoo, Moon-Jib;Byun, Woo-Sup;Lee, Joo-Hong
    • Journal of the Korean Arthroscopy Society
    • /
    • v.9 no.2
    • /
    • pp.132-136
    • /
    • 2005
  • Purpose: The purpose of this study was to compare the clinical results of the arthroscopic anterior cruciate ligament reconstruction used by Bone-Patella tendon-Bone autograft and Achilles tendon allograft. Materials and Methods: We reviewed the results of patients who had been managed with arthroscopic anterior cruciate ligament reconstruction using different graft such as Bone-Patella tendon-Bone autograft and Achilles les tendon allograft. 60patients (average age, 33.5 years)were retrospectively evaluated. The one group(average age, 33.4 years) was 32 patient who had been managed with arthroscopic anterior cruciate ligament reconstruction using Bone-Patella tendon-Bone autograft. The other group(average age, 32.1 years) was 28 patient who had been managed with arthroscopic anterior cruciate ligament reconstruction using Achilles tendon allograft. 2 groups were evaluated subjectively by Lysholm knee scoring scale and objectively by KT-2000 arthrometer. The follow-up period was more than a year(average, 18 month). An early rehabilitation protocol was instituted. Results: On Lysholm knee scoring scale, the final evaluation was nearly normal in all patients. We could not find statistical difference among the two groups by KT-2000TM arthrometer. Conclusion: The use of allografts may be an acceptable choice for ACL reconstruction.

  • PDF

The Follow-up Results of Anterior Cruciate Ligament Reconstruction Using The Flexible Reamer (유연성 연마기를 이용한 관절경적 전방 십자 인대 재건술의 추시 결과)

  • Chae, In-Jung;Wang, Joon-Ho;Choi, Gi-Won;Song, Dong-Ik
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.1
    • /
    • pp.18-23
    • /
    • 2008
  • Purpose: The purpose of this study is to evaluate the clinical results of the function and stability of ACL reconstruction using the flexible reamer. Materials and Methods: We reviewed 98 patients who taken ACL reconstruction using the flexible reamer from March, 1999 to May, 2004. And the follow-up period was more than 12 months in all cases. We used the subjective tests including Lysholm knee score and 2000 International Knee Documentation Committee(IKDC) subjective knee score, and the objective tests such as anterior drawer test, Lachman test, pivot shift test, and KT-2000 arthrometer to evaluate the clinical results. Results: In the range of motion of the affected knee, the extension deficit more than 5 degree was 8 cases preoperatively and 1 case postoperatively. The flexion deficit more than 5 degree was 12 cases preoperatively and 2 cases postoperatively. The mean Lysholm knee score was 61.3 point(${\pm}3.5$ SD) preoperatively and 87.7 point(${\pm}2.0$ SD) postoperatively. The mean 2000 International Knee Documentation Committee(IKDC) subjective knee score was 49 point(${\pm}3.3$ SD) preoperatively and 84 point (${\pm}2.2$ SD) postoperatively. 93 cases were more than grade II in Lachman test preoperatively and 5 cases postoperatively. 71 cases were more than grade II in pivot shift test preoperatively but 89 cases were negative postoperatively. The mean maximal manual difference by KT-2000 arthrometer was 6.8 mm(${\pm}1.9$ SD) preoperatively and 1.8 mm(${\pm}0.8$ SD) postoperatively. Conclusion: ACL reconstruction using the flexible reamer achieved the ideal isometric point of femur and anatomic graft placement, so we could obtain good results, especially in rotational stability.

  • PDF

Comparison of Clinical Outcomes in ACL Reconstruction using auto-Hamstring Tendon and allo-Tibialis Anterior Tendon (자가슬괵건 및 동종전경골건을 이용한 전방십자인대 재건술 후 임상적 결과의 비교)

  • Kim, Jae-Hwa;Lee, Yoon-Seok;Rhee, Seung-Yong;Chung, Ju-Hwan
    • Journal of the Korean Arthroscopy Society
    • /
    • v.11 no.2
    • /
    • pp.104-110
    • /
    • 2007
  • Purpose: The purpose of this study is comparison of clinical outcomes in ACL reconstruction between auto-hamstring tendon and allo-tibialis anterior tendon. Materials and Methods: In this prospective study, we included 60 subjects who underwent ACL reconstruction using 30 hamstring autograft(mainly, national health insurance) and 30 tibialis anterior allograft(including MVA and industrial injuries) between May 2003 and June 2005 by a single surgeon, with a minimum follow-up of 12 months. Outcome measurements were the range of motion, the Lachman test, the IKDC score, the Lysholm score, KT-1000 arthrometer and one-leg hop test. Results: For all the cases, the range of motion was above 135 degrees. The Lachman test, KT-1000 arthrometer and one-leg hop test showed no significant difference between two groups. The IKDC score of auto-hamstring group($87.840{\pm}2.106$) was significantly higher than that of allo-tibialis anterior group($85.273{\pm}2.782$). The Lysholm score of auto-hamstring group($88.067{\pm}2.586$) was also significantly higher than that of allo-tibialis anterior group($85.300{\pm}3.030$). Conclusion: The results of ACL reconstruction using the auto-hamstring tendon and allo-tibialis anterior tendon showed no significant difference in objective items but auto-hamstring group showed better results in subjective scoring. This difference may result from individual factors such as economic problem, secondary gain.

  • PDF

Comparison of Results of ACL Reconstruction According to the Fixation Materials (Metal & Bioabsorbable Interference Screw and RIGIDfix) (금속, 흡수성 간섭 나사못 및 RIGIDfix를 이용한 전방 십자 인대 재건술의 결과 비교)

  • Lim Hong Chul;Wang Joon Ho;Rho Young Jin;Hwang Jin Ho
    • Journal of the Korean Arthroscopy Society
    • /
    • v.7 no.2
    • /
    • pp.206-214
    • /
    • 2003
  • Purpose : To analysis each clinical results after arthroscopic ACL reconstruction with using variable fixatives which are metallic and bioabsorbable interference screw, and RIGIDfix. Therefore, We reported the clinical reliability and safty of ACL reconstruction using RIGIDfix. Materials and Methods : We evaluated the results of arthroscopic ACL resconstruction with patellar tendon autograft among three groups, of which group 1 is used metal interference screw for 44 patients, group 2 used bioabsorbable interference screw for 47 patients, group 3 used RIGIDfix for 42 patients. We compared the clinical results by physical examination (anterior drawer test, Lachman test and pivot shift test), Lysholm score and KT-2000 arthrometer and compared the radiological results by measurement of tunnel and fixatives position and widening and by MRI findings. We analyzed the results by SAS 8.2 Ducan. Tukey and paired t-test Results : Physical instability was in 5 cases, which group 2 had 4 cases and group 3 had 1 case. Lysholm score improved from 59.8. 64.4, 61 to 90.1, 92.3. 92. KT-2000 arthrometer instability improved from 9.20, 10.2, 9.5 to 1.43. 1.62. 2.00 (p=0.478). Radiologically, all cases had excellent tunnel position and cyst change was observed the 8 cases in the group 2, but, all 20 cases 2nd MRI had signal change of peri-fixatives. But, no correlation of clinical results. Conclusion : No statistical difference of clinical instability was found among three groups. And femoral tunnel changes were much observed in group I, II than III. We considered the RIGIDfix has much advantages because the short operation time, better fixation position and much bone contact surface. But, further long term follow up study was needed.

  • PDF

MRI Findings of the Repaired Anterior Cruciate Ligament (전방 십자 인대의 일차 봉합술 후 MRI 소견)

  • Kim, Jung-Man;Koh, In-Jun;Lee, Dong-Yeob;Lee, Yoon-Min
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.1
    • /
    • pp.14-21
    • /
    • 2009
  • Purpose: To investigate MRI findings of the repaired anterior cruciate ligament (ACL). Materials and Methods: Seventeen of arthroscopic ACL primary repair with sutures pull-out technique were followed for 21.4 months (range: 12 to 60 months). Stability was assessed with physical examination and KT-1000 arthrometer (MED metric, San Diego, CA) and postoperative MRI checked with time. The patients were divided into 2 groups according to the location of tear which was defined with the location of remained synovial sleeve. Group I (11 patients) comprised that the tear was located within proximal 1/3 of ACL substance and group II (6 patients) comprised below proximal 1/3. MRI findings of the repaired ACL were evaluated by its course, sharpness, thickness and signal intensity using 3 grade system and correlated with its location of tear. Results: In all cases, Lachman test and flexion-rotation drawer test were negative, pivot-shift test was less than grade 1 and the mean side-to-side difference by use of KT-1000 arthrometer was 1.4 mm (range: -1.0 to 2.5 mm). The overall continuity of the repaired ACL was well maintained in all cases. However, mild sagging was observed in 10 cases(58.8%), mild obscure contour in 6 cases (35.3%), increased thickness in 8 cases (47.1%) and slight increased signal intensity in 5 cases (29.5%). There was no statistical significance in all parameters between 2 groups. And a focal defect at the femoral attachment site in sagittal image was observed in 7 cases (41.2%) of all patients which comprised 2 cases (18.2%) of group I and 5 cases (83.3%) of group II. It was observed more frequently in group II with statistical significance (p=0.035). Conclusion: Some abnormal MRI findings such as mild sagged course, obscure contour, increased thickness and signal intensity, the focal defect at femoral attachment site could be observed even though the stability was well maintained clinically. We thought that the focal defect was affected by the location of tear of ACL.

  • PDF

Anterior Cruciate Ligament Reconsruction Using Tibialis Tendon Allograft - A Short-Term Follow-Up Result - (동종 경골건을 이용한 전방 십자 인대 재건술 -단기 추시 결과-)

  • Woo, Jong-Ken;Ko, Sang-Hun;Lew, Sog-u;Park, Moon-Soo;Jung, Kwang-Hwan;Gwak, Chang-Youl;Lee, Chae-Chil;Cho, Sung-Do
    • Journal of the Korean Arthroscopy Society
    • /
    • v.8 no.2
    • /
    • pp.89-93
    • /
    • 2004
  • Purpose: To evaluate the clinical stability and function after arthroscopic anterior cruciate ligament(ACL) reconstruction using fresh-frozen tibialis tendon allograft. Materials and Methods: Of the patients who underwent ACL reconstruction using tibialis tendon allograft from July 2002 to June 2003, thirty-one patients could be evaluated and the mean follow-up period was 19 months. Evaluations included were Lysholm knee score, 2000 International knee Documentation Committee (IKDC) subjective knee score, Lachman test, pivot shift test, KT-1000 arthrometer measurement and 2000 IKDC knee examination. Results: The mean Lysholm score was 88. Twenty-eight patients (90.3%) were good or exellent for the measured parameters. Twenty-seven patients(87.1%) was over 70 in IKDC subjective knee score. Thirty patients (96.8%) had 1+ firm end or negative Lachman test. 27 patients (87.1%) had a negative pivot shift. Thirty patients (96.8%) had less than 5mm difference of maximal manual difference by KT-1000 arthrometer. Twenty -nine patients (93.5%) were nearly normal or normal grade by 2000 IKDC knee examination. Complications were 1 case of failure and 1 case of infection. Conclusion: ACL reconstruction with the double-stranded fresh-frozen tibialis tendon allograft resulted in a reliable and predictable outcome after short-term follow-up.

  • PDF

The Benefit of KT-2000 Knee Ligament Arthrometer in Diagnosis of Anterior Cruciate Ligament Injury (슬관절 전방 십자 인대 파열의 진단에 있어서 KT-2000 기기의 유용성)

  • Park, Jai-Hyung;Kim, Hyoung-Soo;Jung, Kwang-Gyu;Yoo, Jeong-Hyun
    • Journal of the Korean Arthroscopy Society
    • /
    • v.8 no.2
    • /
    • pp.82-88
    • /
    • 2004
  • Purpose: In this study, we intended to ascertain the benefit of KT-2000 Knee arthrometer(KT-2000) in the diagnosis of ACL(Anterior cruciate ligament) injury by comparing the anterior displacement of normal knee with that of ACL deficient knee. Materials and Methods: We designated two examiners to measure the anterior displacement of the knee joint of 30 healthy individuals, using KT-2000, at 30$^{\circ}$ flexion setting of muscle full relaxation, contraction, 25$^{\circ}$ internal rotation and 25$^{\circ}$ external rotation and analyzed these results according to the variables and measured the preoperative anterior displacement of the ACL injured knee in the 30 patients who have gone through an arthroscopic ACL reconstruction later. Results: The results of examiner 1 are 6.5${\pm}$1.5 mm, 2.5${\pm}$0.9 mm, 4.8${\pm}$1.2 mm, 6.4${\pm}$1.3 mm in right knee and 5.6${\pm}$1.3 mm, 2.1${\pm}$0.8 mm, 4.5${\pm}$1.2 mm, 5.2${\pm}$1.3 mm in left knee, in order of muscle full relaxation, contraction, 25$^{\circ}$ internal rotation and 25$^{\circ}$ external rotation. The results of examiner 2 are 6.9${\pm}$1.2mm, 2.9${\pm}$1.1mm, 5.6${\pm}$1.6mm, 6.9${\pm}$1.5mm in right, 5.5${\pm}$1.7 mm,1.9${\pm}$0.9 mm, 5.1${\pm}$1.9 mm, 5.7${\pm}$1.6 mm in left knee, The side to side difference of examiner 1 in the setting of muscle relaxation is 0.9${\pm}$1.0 mm. The anterior displaement of ACL injured knee is average 11${\pm}$2.93 mm and difference of average 6.5${\pm}$2.31 mm form that of normal. In comparison between the right and left knees of healthy individuals, the both results of two examiners showed the statistical difference in the setting of muscle full relaxation but, the results showed the side to side difference below 2 mm in 25case(83%), 21case(70%) respectively and above 3 mm in just 1 case. In the comparison between the normal and ACL injured knees, the results show the statistical difference of the side to side difference in the setting of muscle relaxation(p<0.05). Conclusion: The KT-2000 result is affected by relaxation of muscles around knee, flexion angle of knee joint, rotation of tibia, the strength of displacing force, time of the test and physical factors as height and weight. However, the Accuracy of diagnosis of ACL injury by KT-2000 will increase if the examiner is skillful and the tests are made on the exact position of knee joint.

  • PDF

Effects of Knee Position during the Graft Fixation of the Arthroscopic Anterior Cruciate Ligament Reconstruction with Autogenous Hamstring Graft (이식 건 고정 시 슬관절 위치가 자가 슬괵건을 이용한 관절경적 전방 십자 인대 재건술 후 결과에 미치는 영향)

  • Lee, Churl-Woo;Yoo, Jae-Doo;Roh, Kwon-Jae;Park, Seong-Pil
    • Journal of the Korean Arthroscopy Society
    • /
    • v.9 no.2
    • /
    • pp.143-147
    • /
    • 2005
  • Purpose: In case of anterior cruciate ligament (ACL) reconstruction, graft tendon is generally fixed in tibial tunnel with knee extended. When reconstructing ACL using hamstring tendon, the authors aim to find out the effect of knee joint position during graft fixation on postoperative knee joint stability and range of motion. Materials and Methods: Prospective study was done on patients who have undergone ACL reconstruction using hamstring tendon from May 2002 to January 2003 We used Rigifix system (Mitek Product, Johnson and Johnson, USA) and Intrafix system for fixation. Thirty nine patients received ACL reconstruction during this period. Excluding 2 patients lost in the follow-up, 37 patients were analyzed. The mean follow-up period was 14 months $(13{\sim}25months)$. Knee position was decided alternatively without any bias. Clinical evaluation was based on Lachman test, pivot shift test, Lysholm score, IKDC(international knee documentation committee) assessment and side to side KT-1000 maximal manual arthrometer difference. Results: After the last follow-up, average postoperative Lysholm score was 93.1 poins(65-98points). According to IKDC score, 26 cases were normal, 10 cases were nearly normal, 1 case was abnormal and we had no case of severe abnormality. The mean difference from the normal side was 2.5 mm under maximal manual loading KT-1000 arthrometer. According to postoperative Lachman test, 32 cases were normal,2 cases were grade I and 1 case was grade II. There were 34 cases of normal, 2 cases of grade I and 1 case of grade II. When using maximal manual KT-1000 arthrometer side to side difference, the difference from the normal side while fixing the tibia at 20'knee flexion was 2.3 mm and at full extention the difference was 2.7 mm. The range of motion at postoperative 1 year showed 5 degree flexion contracture in 1 case at 20 degrees knee flexion and 10 degrees of flexion limitation was observed in 2 cases at full extension. Conclusion: When ACL reconstruction using autogenous hamstring tendon, anterior laxity showed no difference in its stability between two groups. Tibial side fixation at full extension may be helpful in preventing flexion contracture due to overconstrained graft tendon.

  • PDF