• 제목/요약/키워드: Arterial pulse wave sensor system

검색결과 12건 처리시간 0.029초

무선 기반의 광섬유 간섭계형 맥파센서 시스템 (Wireless Optical Fiber Interferometer Arterial Pulse Wave Sensor System)

  • 박재희;신종덕
    • 센서학회지
    • /
    • 제22권6호
    • /
    • pp.439-443
    • /
    • 2013
  • A wireless optical fiber interferometer arterial pulse wave sensor system is developed for remote sensing. The wireless optical fiber sensor system consists of Zigbee communication modules and an optical fiber interferometer arterial pulse wave sensor. The optical fiber arterial pulse wave sensor is an in-line Michelson interferometer enclosed with steel reinforcement in a heat-shrinkable tube. The Zigbee communication modules are composed of an ATmega128L microprocessor and a CC2420 Zigbee chip. The arterial pulse waves detected by the optical fiber sensor were transmitted and received via the Zigbee communication modules. The experimental results show that the wireless optical fiber sensor system can be used for monitoring the arterial pulse waves remotely.

구강 내부 맥파 계측을 위한 센서 시스템 연구 (A Study on the Arterial Pulse Wave Measuring System of an Oral Cavity)

  • 김경호
    • 반도체디스플레이기술학회지
    • /
    • 제6권4호
    • /
    • pp.43-47
    • /
    • 2007
  • In this paper, we propose a novel sensor system for measuring the arterial pulse in an oral cavity. In order to measure pulse wave in oral cavity, the proposed system is designed with reflection type arterial wave sensor, not by using transmission type arterial pulse wave sensor. Driving circuit through pulse current is designed for solving self-heating problem of LED. The effectiveness of the proposed sensor system is compared with pulse wave between pulse wave of oral cavity and other body parts as well as with characteristic measurements. The experiment shows that the proposed sensor system is adaptive to capturing consecutive and meaningful biometric signals through the variation of pulse wave changes in oral cavity when exercising. The study result expects to design and develop mobile sensors which could be adapted to healthcare devices.

  • PDF

Measurement of Arterial Pulse Wave at the Temple Using PZT Piezo Sensor

  • Kil Se Kee;Han Young Hwan;Lee Eung Hyuk;Park Young Bae;Cho Heung Ho;Min Hong Ki;Hong Seung Hong
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2004년도 학술대회지
    • /
    • pp.772-775
    • /
    • 2004
  • Generally, arterial pulse waves are measured at the radial arterial of wrist or carotid arterial of neck using a sensor such as pressure sensor, piezoelectric sensor or optic sensor. But in this paper, arterial pulse wave is measured at the temple using PZT piezo sensor which is attached on the temple in form of a hair-band. Arterial Pulse waves are generally measured when a reagent is in a static state. But in this paper, we implemented the arterial pulse wave measurement system, as a previous stage of the arterial pulse wave measurement system for running at outdoors or on a running machine, that measures arterial pulse waves at the temple, which is the least moving part when running. Thorough the continuous study, if the motion artifact when running is possible to be removed, the system will be able to perform monitoring of running men's states and especially emergency signals such as serious pulse waves of an/old and feeble persons and handicapped persons.

  • PDF

압전 필름과 전도성 섬유를 이용한 맥파 전달 속도 측정을 위한 센서의 제작 및 성능평가 (Fabrication and Evaluation of Sensor for Measuring Pulse Wave Velocity using Piezo Film and Conductive Textile)

  • 김정채;지선하;유선국
    • 센서학회지
    • /
    • 제21권2호
    • /
    • pp.135-143
    • /
    • 2012
  • Arterial stiffness is causing the serious problems for human who is suffered from hypertension and metabolic syndrome. So it is important that measure the arterial stiffness for early prevention. Many researches point out that pulse wave velocity(PWV) is the reliable and simple method to predict arterial stiffness. In this paper, we developed the sensing parts that detect the pulse wave and ECG by using piezoelectric film and conductive textile with elastic band. Our system could detect 3ch pulse wave and ECG. Simultaneously, our algorithm extracts the features for calculating the delays among pulse waves. The delays are the significant parameter to estimate PWV, thus we design the experiment for evaluating the performance of our sensing parts. The reference is PP-1000(HanByul Meditech, Korea) that is good for performance evaluation. As a result, the start point of the pulse wave was the most reliable feature for comparing with PP-1000(r=0.691, P=0.00). The results between two operators showed that there is only a slight difference in the reproducibility of the devices. In conclusion, we assume that the suggested sensor could be more comfortable and faithful method for arterial stiffness.

A Wrist Watch-type Cardiovascular Monitoring System using Concurrent ECG and APW Measurement

  • Lee, Kwonjoon;Song, Kiseok;Roh, Taehwan;Yoo, Hoi-jun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제16권5호
    • /
    • pp.702-712
    • /
    • 2016
  • A wrist watch type wearable cardiovascular monitoring device is proposed for continuous and convenient monitoring of the patient's cardiovascular system. For comprehensive monitoring of the patient's cardiovascular system, the concurrent electrocardiogram (ECG) and arterial pulse wave (APW) sensor front-end are fabricated in $0.18{\mu}m$ CMOS technology. The ECG sensor frontend achieves 84.6-dB CMRR and $2.3-{\mu}Vrms$-input referred noise with $30-{\mu}W$ power consumption. The APW sensor front-end achieves $3.2-V/{\Omega}$ sensitivity with accurate bio-impedance measurement lesser than 1% error, consuming only $984-{\mu}W$. The ECG and APW sensor front-end is combined with power management unit, micro controller unit (MCU), display and Bluetooth transceiver so that concurrently measured ECG and APW can be transmitted into smartphone, showing patient's cardiovascular state in real time. In order to verify operation of the cardiovascular monitoring system, cardiovascular indicator is extracted from the healthy volunteer. As a result, 5.74 m/second-pulse wave velocity (PWV), 79.1 beats/minute-heart rate (HR) and positive slope of b-d peak-accelerated arterial pulse wave (AAPW) are achieved, showing the volunteer's healthy cardiovascular state.

촬상소자를 이용한 맥동의 2차원 계측 (2-dimensional Measurement of Arterial Pulse by Imaging Devices)

  • 김기왕
    • 대한한의진단학회지
    • /
    • 제12권2호
    • /
    • pp.8-17
    • /
    • 2008
  • Objectives: For the traditional pulse diagnosis in Oriental Medicine, not only the pulse shape in time domain, but the width, length and depth of arterial pulse also should be measured. However, conventional pulse diagnostic systems have failed to measure the spatial parameters of the arterial pulse e.g. effective length of arterial pulse in the wrist. In fact, there are many ways to measure that kind of spatial features in arterial pulsation, but among them, the method using image sensor provides relatively cheap and simple way, therefore I tested feasibility of measuring 2-dimensional pressure distribution by imaging devices. Methods: Using widely used PC cameras and dotted balloons, the subtle oscillation of skin over the radial artery was recorded continuously, and then the displacement of every dot was calculated. Consequently, the time course of that displacements shows arterial pulse wave. Results: By the proposed method I could get pressure distribution map with 30Hz sampling rate, 21steps quantization resolution, and approximately 1mm spatial resolution. With reduced quantization resolution, $3cm{\times}4cm$ view angle could be achieved. Conclusion: Although this method has some limitations, it would be useful method for detecting 2-dimensional features of arterial pulse, and accordingly, this method provides a novel way to detect 'narrow pulse', 'wide pulse', 'long pulse', 'short pulse', and their derivatives.

  • PDF

지능형 맥진기 구현 (Implementation of Intelligence Pulse Wave Detection System)

  • 홍유식;유준상;장세진;선승호;이우범;남동현;유문성;최명복;이상석
    • 한국인터넷방송통신학회논문지
    • /
    • 제13권2호
    • /
    • pp.245-254
    • /
    • 2013
  • 동양 의학에서는 맥파를 분석해서 많은 질병을 분류하고 치료하고 있다. 그러나 현재까지 맥파를 분석하는 방법은 매우 주관적인 방법을 사용하기 때문에 신뢰도가 떨어지는 문제점이 발생한다. 뿐만 아니라, 기존 맥진기의 문제점으로는 요골동맥에 정확하게 맥진 센서가 위치하지 못하기 때문에 측정 위치에 따라 측정결과가 상이하고 측정절차에 매우 민감하여 높은 재현성을 실현 못하고 있는 실정이다. 본 논문에서는 이러한 문제점을 해결하기 위해서 홀센서를 이용한 휴대용 맥진기를 이용해서 실맥 및 허맥을 분석 하는 연구 결과를 제안하였다. SPSS 통계 기법으로 분석한 실맥 및 허맥 최종 분석결과, 95% 신뢰도 구간에서 N.time(절흔점 시간) 및 S.amp (상승파형 크기) 평균치가 유의성이 있음을 입증하였다.

요골동맥 직경 변화에 따른 맥파 측정 시스템 개발 (Development of an Measuring System for Pulse Wave Corresponding to Different Radial Artery Diameters Caused by Indentation)

  • 이전;우영재;전영주;이유정;김종열
    • 전기학회논문지
    • /
    • 제57권12호
    • /
    • pp.2351-2357
    • /
    • 2008
  • Noninvasive radial artery pulse wave has been widely used not only for the pulse wave analysis(PWA) itself but also for assessment of arterial stiffness with estimated aortic pulse wave from peripheral pulse wave. However, it has been found that the deformation of pulse shape can be caused readily by changing measuring position, indentation pressure, and so on. So, in this study, we have developed a system which can measure radial pulse wave and skin displacement simultaneously while the indentation body goes down to occlude subject's radial artery. This system can be divided into a measuring apparatus part, an indentation control hardware part, a data acquisition part and a control and computation part. And, the measuring apparatus consists of an arm-rest, a step motor, an indentation body, a laser displacement sensor(LK-G30, Keyence Co.) and pulse wave sensor. Under load-free condition and radial artery loaded condition, the evaluation of developed system has been performed. From these results, we can conclude: 1) The developed system can control the indentation body quantitatively and the adopted laser displacement sensor shows linear output characteristic even with skin as a reflector. 2) This system can measure the pulse wave and the displacement of indentation body, that is, skin displacement simultaneously at each specific level of indentation body. 3) This system can provide the number of motor steps used to get down the indentation body, the measured skin displacement, the calculated indentation pressure, the calculated pulse pressure and the pulse waveform as well as the information generated by combining these with each others. 4) This system can reveal the relationship between the morphological changes of pulse wave and the estimated displacement of radial artery wall by indentation. Consequently, the developed system can furnish more abundant information on radial artery than previous diagnosis systems based on tonometric measurement. In further study, we expect to setup the standard measuring process and to concrete the algorithm for the estimation of radial artery's diameter and of displacement of radial artery's wall. Furthermore, with well designed clinical studies, we hope to turn out the usefulness of developed system in the field of cardiovascular system evaluation.

영구자석-홀 맥진센서를 이용한 양손 동시측정 맥진파형 비교 연구 (Comparison of Simultaneously Measured Pulse Waveforms from Both Hands using Permanent Magnet-Hall Pulsimeter Sensor)

  • 유기두;황성기;이상석
    • 한국자기학회지
    • /
    • 제22권1호
    • /
    • pp.27-31
    • /
    • 2012
  • 영구자석과 홀소자로 구비된 두 대의 집게형 맥진기 시제품을 이용하여 비가압 상태에서 양손 요골동맥의 맥진파형을 동시측정한 신호들을 비교 분석하였다. 20대 남성 피실험자 22명을 대상으로 측정된 오른손잡이와 왼손잡이의 두 맥진파형들은 위상차를 갖고 뚜렷하게 구별되었다. 서로 다른 빠름과 늦음으로 인해 두 개의 맥진파형들의 위상차 부호는 맥파전달속도가 오른손과 왼손 혈관의 총길이 보다는 자주 사용하는 팔의 근육 특성에 의존한다는 분석이 가능하였다.

Fuzzy Simulation of a Multi-electronic Acupuncture System and Clip-type Pulsimeter Equipped with a Magnetic Sensing Hall Device

  • Hong, You-Sik;Rhee, Jin-Kyu;Kim, Han-Kyu;Son, Il-Ho;Yoon, Woo-Sung;Lee, Nam-Kyu;Park, Do-Young;Kim, Keun-Ho;Kim, Yong-Jin;Khajidmaa, P.;Lee, Sang-Suk
    • Journal of Magnetics
    • /
    • 제19권3호
    • /
    • pp.255-260
    • /
    • 2014
  • A portable clip-type pulsimeter equipped with a magnetic sensing Hall device has been developed to raise the accuracy of oriental disease diagnosis and therapy by convergence of magnetism and oriental medicine. To improve accuracy and reliability of conventional pulsimeter due to subjective analysis of the pulse wave and measuring position dependency of the arterial pulse sensor, the fuzzy algorithm was applied to analyze the strong- and weak-pulse wave symptom. Optimal time for electronic acupuncture was calculated using fuzzy rules and interference were drawn from objective data in view of pre-treatment. Moreover, the electrical characteristics of the pain parts that respond to acupuncture point were applied in view of post-treatment to propose the scientific pulse wave algorithm and simulation experiment.