• Title/Summary/Keyword: Arterial pressure shape

Search Result 8, Processing Time 0.023 seconds

Analysis of Oscillometric Model based on Shape of Arterial Pressure (동맥압 형태를 고려한 오실로메트릭 모델분석)

  • 임성수;이경중
    • Journal of Biomedical Engineering Research
    • /
    • v.21 no.4
    • /
    • pp.411-417
    • /
    • 2000
  • This paper describes the analysis of the oscillometric method based on the shape of arterial pressure and proposal of a new algorithm for estimating the blood pressure by computer simulation. In the first step, the arterial pressure model which is able to control the shape of arterial pressure was designed and then we simulated the oscillometric model using both the existing exponential model showing the static arterial pressure-volume relation and the designed arterial pressure model. By analyzing the correlation of characteristic ratio based on the shape of arterial pressure, we could find that the characteristic ratio was not the only standard parameter for estimating systolic and diastolic pressure. We were able to estimate the shape of arterial pressure by computing the correlation of arterial pressure shape with oscillation shape. Finally, we proposed an algorithm which is able to estimate systolic and diastolic pressure according to pressure(Pp) table constructed from the relation of maximum amplitude of oscillation and arterial pressure shape. We tested 60 arterial pressure waveforms having various arterial pressure shape and pulse. As a results, the absolute deviation average values of the estimation of systolic, diastolic and mean pressure were 1.62%, 2.40% and 2.20%, respectively. In conclusions, the proposed algorithm showed the possibility of usefullness in estimating the blood pressure.

  • PDF

A Study on the Compensation of Blood Pressure Caused by the Change of Arterial Pressure Shape (동맥압 형태변화에 따른 혈압 보정에 관한 연구)

  • Lim, S.S.;Park, K.L.;Lee, K.J.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.177-178
    • /
    • 1998
  • This paper is a study on compensation for error in estimation of mean pressure according to the change of arterial pressure shape. Because arterial pressure shape affects the mean pressure and blood volume which are important factors for measurement of blood pressure(BP), change of arterial pressure shape cause BP measurement error. In order to solve this problem, we add the compensation function C($\alpha$), depending on arterial pressure shape, to mathematical oscillometric model. Consequently, we could accurately estimate the blood pressure by correcting of the error using compensation function.

  • PDF

Blood Pressure Simulation using an Arterial Pressure-volume Model

  • Yoon, Sang-Hwa;Kim, Jae-Hyung;Ye, Soo-Young;Kim, Cheol-Han;Jeon, Gye-Rok
    • Transactions on Electrical and Electronic Materials
    • /
    • v.9 no.1
    • /
    • pp.38-43
    • /
    • 2008
  • Using an arterial pressure-volume (APV) model, we performed an analysis of the conventional blood pressure estimation method using an oscillometric sphygmomanometer with computer simulation. Traditionally, the maximum amplitude algorithm (MAA) has been applied to the oscillation waveforms of the APV model to obtain the mean arterial pressure and the characteristic ratio. The estimation of mean arterial pressure and characteristic ratio was significantly affected by the shape of the blood pressure waveforms and the cutoff frequency of high-pass filter (HPF) circuitry. Experimental errors result from these effects when estimating blood pressure. To determine an algorithm independent of the influence of waveform shapes and parameters of HPF, the volume oscillation of the APV model and the phase shift of the oscillation with fast Fourier transform (FFT) were tested while increasing the cuff pressure from 1 mmHg to 200 mmHg (1 mmHg/s). The phase shift between ranges of volume oscillation was then only observed between the systolic and the diastolic blood pressures. The same results were obtained from simulations performed on two different arterial blood pressure waveforms and one hyperthermia waveform.

2-dimensional Measurement of Arterial Pulse by Imaging Devices (촬상소자를 이용한 맥동의 2차원 계측)

  • Kim, Ki-Wang
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.12 no.2
    • /
    • pp.8-17
    • /
    • 2008
  • Objectives: For the traditional pulse diagnosis in Oriental Medicine, not only the pulse shape in time domain, but the width, length and depth of arterial pulse also should be measured. However, conventional pulse diagnostic systems have failed to measure the spatial parameters of the arterial pulse e.g. effective length of arterial pulse in the wrist. In fact, there are many ways to measure that kind of spatial features in arterial pulsation, but among them, the method using image sensor provides relatively cheap and simple way, therefore I tested feasibility of measuring 2-dimensional pressure distribution by imaging devices. Methods: Using widely used PC cameras and dotted balloons, the subtle oscillation of skin over the radial artery was recorded continuously, and then the displacement of every dot was calculated. Consequently, the time course of that displacements shows arterial pulse wave. Results: By the proposed method I could get pressure distribution map with 30Hz sampling rate, 21steps quantization resolution, and approximately 1mm spatial resolution. With reduced quantization resolution, $3cm{\times}4cm$ view angle could be achieved. Conclusion: Although this method has some limitations, it would be useful method for detecting 2-dimensional features of arterial pulse, and accordingly, this method provides a novel way to detect 'narrow pulse', 'wide pulse', 'long pulse', 'short pulse', and their derivatives.

  • PDF

Effect of Residual Stress on Femoral Arterial Stress-Strain Behavior

  • Chandran, K.B.;Mun, J.H.;Chen, J.S.;Nagaraj, A.;McPherson, D.D.
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.7
    • /
    • pp.965-973
    • /
    • 2001
  • It is well established that arteries are subjected to residual stress. Due to the effect of residual stress, the arteries open to a horse-shoe shape when a longitudinal cut is made on an excised arterial segment. Previously, the residual stress has been quantified by the opening angle of the horse-shoe shape. We have employed a finite element analysis of the open arterial segment to restore the same to the original cylindrical shape and computed the circumferential strain as well as the stress distribution in the wall. In this study, the stress distribution in the femoral arteries of miniswine was computed with and without the residual stress for a range of transmural pressures. Our analysis showed that the residual stress has the effect of redistribution of the circumferential stresses between the intima and the adventitia under physiological loading. The redistribution of the stress with the inclusion of residual stress may be important in the studies on effect of wall stresses on the endothelial and vascular smooth muscle cells.

  • PDF

Mock Circulatory Robot with Artificial Aorta for Reproduction of Blood Pressure Waveform (혈압 파형 재현을 위한 인공 대동맥 기반 모의 순환계 로봇)

  • Jae-Hak Jeong;Yong-Hwa Park
    • The Journal of Korea Robotics Society
    • /
    • v.19 no.2
    • /
    • pp.221-228
    • /
    • 2024
  • As the importance of cardiovascular health is highlighted, research on its correlation with blood pressure, the most important indicator, is being actively conducted. Therefore, extensive clinical data is essential, but the measurement of the central arterial blood pressure waveform must be performed invasively within the artery, so the quantity and quality are limited. This study suggested a mock circulatory robot and artificial aorta to reproduce the blood pressure waveform generated by the overlap of forward and reflected waves. The artificial aorta was fabricated with biomimetic silicone to mimic the physiological structure and vascular stiffness of the human. A pressurizing chamber was implemented to prevent distortion of the blood pressure waveform due to the strain-softening of biomimetic silicone. The reproduced central arterial blood pressure waveforms have similar magnitude, shape, and propagation characteristics to humans. In addition, changes in blood pressure waveform due to aging were also reproduced by replacing an artificial aorta with various stiffness. It can be expanded to construct a biosignal database and health sensor testing platform, a core technology for cardiovascular health-related research.

A Study of the Cardiovascular Aging Effect on the Pulse Shape (심혈관 노화가 맥상(脈象)에 미치는 영향)

  • Shin, Sang-Hoon;Rhim, Hye-Whon;Park, Young-Jae;Park, Young-Bae
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.9 no.1
    • /
    • pp.59-68
    • /
    • 2005
  • Background and purpose: Cardiovascular disease will undoubtedly rise along with the aging of the 'baby-boom' generation. The purpose of this study is to find the new index of the cardiovascular aging. Methods: The effects of aging on the heart and the arterial system are surveyed in the point of structure and function. Results: Arterial stiffening is due to the fatiguing effects of periodic stress on the arterial wall and is the main reason for increasing pulse wave velocity. The systolic hypertension is caused by the early return of wave reflection. The increased after-load by the arterial change leads to the development of left ventricular hypertrophy. The reduction in left ventricular compliance cause the impairments of the diastolic function. In contrast to the lower limb, aging effect in the upper limb are almost due to the ascending aortic pressure wave and the reflected wave from the lower limb. Conclusion: We have the following points. (1) The change of physiological pulse pattern by age can be explained by the early returning of reflected wave. (2) The atrial pulse in old age are generated by the left ventricular hypertrophy.

  • PDF

Development of an Measuring System for Pulse Wave Corresponding to Different Radial Artery Diameters Caused by Indentation (요골동맥 직경 변화에 따른 맥파 측정 시스템 개발)

  • Lee, Jeon;Woo, Young-Jae;Jeon, Young-Ju;Lee, Yu-Jung;Kim, Jong-Yeol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.12
    • /
    • pp.2351-2357
    • /
    • 2008
  • Noninvasive radial artery pulse wave has been widely used not only for the pulse wave analysis(PWA) itself but also for assessment of arterial stiffness with estimated aortic pulse wave from peripheral pulse wave. However, it has been found that the deformation of pulse shape can be caused readily by changing measuring position, indentation pressure, and so on. So, in this study, we have developed a system which can measure radial pulse wave and skin displacement simultaneously while the indentation body goes down to occlude subject's radial artery. This system can be divided into a measuring apparatus part, an indentation control hardware part, a data acquisition part and a control and computation part. And, the measuring apparatus consists of an arm-rest, a step motor, an indentation body, a laser displacement sensor(LK-G30, Keyence Co.) and pulse wave sensor. Under load-free condition and radial artery loaded condition, the evaluation of developed system has been performed. From these results, we can conclude: 1) The developed system can control the indentation body quantitatively and the adopted laser displacement sensor shows linear output characteristic even with skin as a reflector. 2) This system can measure the pulse wave and the displacement of indentation body, that is, skin displacement simultaneously at each specific level of indentation body. 3) This system can provide the number of motor steps used to get down the indentation body, the measured skin displacement, the calculated indentation pressure, the calculated pulse pressure and the pulse waveform as well as the information generated by combining these with each others. 4) This system can reveal the relationship between the morphological changes of pulse wave and the estimated displacement of radial artery wall by indentation. Consequently, the developed system can furnish more abundant information on radial artery than previous diagnosis systems based on tonometric measurement. In further study, we expect to setup the standard measuring process and to concrete the algorithm for the estimation of radial artery's diameter and of displacement of radial artery's wall. Furthermore, with well designed clinical studies, we hope to turn out the usefulness of developed system in the field of cardiovascular system evaluation.