• Title/Summary/Keyword: Arson fire test

Search Result 7, Processing Time 0.02 seconds

A Experimental Study on the Arson Fire Characteristics (방화(放火)화재 특성에 관한 실험적 연구)

  • Choi, Jin;Kwon, Oh-Seung;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.10 no.2
    • /
    • pp.1-13
    • /
    • 2008
  • This Study is to analyze the characteristics of arson fire under fire dynamics to protect people and property from arson fire which has been radically increased with the development of the Korean economy. Assembly and merchandise purposes such as theater, retail, and exhibition has been performed as the arson fire study. The experiment for this study is based on the analysis of the characteristic for its own combustion process and smoke spread when arson fire occurs. This study presents the analysis through comparing the condition of setting fire using liquid fuel such as thinner on purpose to the condition of setting fire naturally depending on each occupancy.

Study on the Combustion Characteristics of Flammable materials and Combustion Accelerants in an Arson (방화 범죄에서 가연성 물질과 연소촉진제의 연소 특성에 관한 연구)

  • Park, Hye-Jeong;Nam, Ki-Hun;Kim, Kwang-Il
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.7-11
    • /
    • 2017
  • The purpose of this study is to recognize the necessity for the management of the available materials in cases of arsons and to prevent arson gaining an understanding of the combustion characteristics of the flammable materials and combustion accelerants in arson cases. We investigated and analyzed the statistical data on arsons and selected flammable materials (wood, paper, synthetic textiles, synthetic resins), and combustion accelerants (gasoline, diesel, solvent) that are frequently used in cases of arson. We conducted a thermogravimetric analysis to assess the thermal properties of the flammable materials. Also, we conducted burning and flame spread rate tests for the purpose of comparing and analyzing the combustion characteristics of the flammable materials and combustion accelerants.

A Study on the Characteristics and the Disaster Prevention Measures of Incendiary Fire (방화(放火)화재의 특성 및 방재대책에 관한 연구)

  • Choi, Jin
    • Fire Science and Engineering
    • /
    • v.22 no.5
    • /
    • pp.9-21
    • /
    • 2008
  • The objective of this study is to suggest a fire prevention measure for suppressing and preventing loss of precious human lives and property damages. The characteristics of incendiary fire are analyzed in terms of fire engineering to review a plan for promoting for coping with the risk. In this study, a medical aspect such as mental and psychological analysis of the motive or act of an incendiary and legal and administrative problems such as the penalty for the incendiary are not included in the scope of the study. Fire statistics data of Korea, Japan, and U.S. are investigated for analysis of actual states of incendiary fire occurrences. In particular, to quantitatively recognize the burning characteristics of common fire and the burning characteristics of incendiary fire, a fire model test and computer simulation were performed. And a plan for promoting the optimal incendiary fire prevention measure were suggest.

The Real Scale Fire Tests for Vertical Fire Spread Study of External Finishing Material (외벽 마감재료의 수직화재 확산 연구를 위한 실물화재 실험)

  • Kweon, Oh-Sang;Yoo, Yong-Ho;Kim, Heung-Youl;Kim, Jung-Hyun;Min, Se-Hong
    • Fire Science and Engineering
    • /
    • v.26 no.6
    • /
    • pp.85-91
    • /
    • 2012
  • To reduce human life and property damage at the fire in a building, it is most critical to control flame spread in the early stage. Fire spread prevention measure generally includes fire resistance performance securing of structure member in the arson zone and use limitation based on combustion performance of finishing material. The latter is most fundamental fire safety design to determine flame spread, but domestic combustion test determines combustion performance by specimen sized fire test method. Thus, there are many restrictions in the determination of combustion performance by composite material such as sandwich panel. Especially, outer finishing material uses a variety of composite material such as dry bit, aluminum composite panel, and metal panel compared to inner finishing material. Therefore, this study would determine vertical fire spread features by a full scaled fire experiment through the test method of ISO 13785-2, an international test standard.

A Study on the evaluation of the auditory guide facility under emergency situation (비상시 청각형 유도시설의 유도성능 평가에 관한 연구)

  • Na, Wook-Jung;Jeon, Gyu-Yeob;Hong, Won-Hwa
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1205-1208
    • /
    • 2006
  • Today, our city structure is being complicated from the development of industry. Invisible losses, life and fortune loss caused by arson is embossed in our society. The preparation of counter plan about increasing factors of fire damage is not easy. With respect to mankind life, however, it is very important. Therefore, the focus of this research examine refuge degree in each smoke density level when a fire break out in the space. I evaluated auditory guide facility thorough real scale test. In this thesis, I will propose the efficient refuge deriving facilities.

  • PDF

The Study of Fire Suppression Capability of Sprinkler System for Wooden Cultural Properties (스프링클러 소화설비의 목조문화재 소화성능에 관한 연구)

  • Roh, Sam-Kew;Ham, Eun-Gu;Kim, Dong-Chul
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.51-57
    • /
    • 2011
  • The domestic wooden cultural properties applied to the sprinkler extinguishing system was confirmed extinguishing performance through fire experiments. Consists of wooden cultural properties of a fire, a flammable material is vulnerable in terms of. The scale of fire will occur to vary appearance of the initial fire in case of arson. Sprinkler nozzles of the characteristics, the discharging pressure is 1 bar and the flow rate is 80 lpm, applied in this experiment. Fire performance experiments were tested in two separated in each of the scale of the fire and cultural properties. Fire extinguishing performance test results was low in high ceilings and two or more units of the fire scale. Fire growth environment of the actual wooden cultural properties to experimental models when you consider that it is more vulnerable, sprinkler extinguishing system is required sufficient verification in order to apply fire protection of the wooden cultural properties.

He Study of Fire Suppression Capability of Low Pressure Water-Mist System for Wooden Cultural Properties (목조한옥에 대한 저압식 미분무 소화설비의 소화성능에 관한 연구)

  • Roh, Sam-Kew;Kim, Dong-Cheol;Ham Eun-Gu
    • Journal of the Society of Disaster Information
    • /
    • v.8 no.4
    • /
    • pp.401-410
    • /
    • 2012
  • The study verified the extinguishing performance of the low pressure water-mist system, which is used to extinguish fire at domestic wooden architecture, through a fire test. Made of inflammable materials, a wooden house is vulnerable to fire, and the size of fire may vary from the early stage in case of arson. With the discharging pressure of 8 bar and the flow rate of 35 lpm, the low pressure water-mist nozzle used in the experiment has considerable discharging amount compared to other water-mist nozzles. The extinguishing performance was tested based on the size of fire and architecture. Test results demonstrated that the extinguishing performance was not affected by the size of a house, but decreased significantly when the size of fire was above unit 1. Taking into account that the environment of actual wooden cultural properties is more vulnerable than that of the experiment model, sufficient investigation on extinguishing performance is required to apply the water-mist extinguishing system to wooden architecture.