• 제목/요약/키워드: Array calibration

검색결과 213건 처리시간 0.027초

INTRODUCTION OF NUC ALGORITHM IN ON-BOARD RELATIVE RADIOMERIC CALIBRATION OF KOMPSAT-2

  • Song, J.H.;Choi, M.J.;Seo, D.C.;Lee, D.H.;Lim, H.S.
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2007년도 Proceedings of ISRS 2007
    • /
    • pp.504-507
    • /
    • 2007
  • The KOMPSAT-2 satellite is a push-broom system with MSC (Multi Spectral Camera) which contains a panchromatic band and four multi-spectral bands covering the spectral range from 450nm to 900nm. The PAN band is composed of six CCD array with 2528 pixels. And the MS band has one CCD array with 3792 pixels. Raw imagery generated from a push-broom sensor contains vertical streaks caused by variability in detector response, variability in lens falloff, pixel area, output amplifiers and especially electrical gain and offset. Relative radiometric calibration is necessary to account for the detector-to-detector non-uniformity in this raw imagery. Non-uniformity correction (NUC) is that the process of performing on-board relative correction of gain and offset for each pixel to improve data compressibility and to reduce banding and streaking from aggregation or re-sampling in the imagery. A relative gain and offset are calculated for each detector using scenes from uniform target area such as a large desert, forest, sea. In the NUC of KOMPSAT-2, The NUC table for each pixel are divided as HF NUC (high frequency NUC) and LF NUC (low frequency NUC) to apply to few restricted facts in the operating system ofKOMPSAT-2. This work presents the algorithm and process of NUC table generation and shows the imagery to compare with and without calibration.

  • PDF

이중 현미경 구조를 이용한 마이크로 렌즈 및 핀홀 어레이 기반 병렬 공초점 시스템 (A Parallel Mode Confocal System using a Micro-Lens and Pinhole Array in a Dual Microscope Configuration)

  • 배상우;김민영;고국원;고경철
    • 제어로봇시스템학회논문지
    • /
    • 제19권11호
    • /
    • pp.979-983
    • /
    • 2013
  • The three-dimensional measurement method of confocal systems is a spot scanning method which has a high resolution and good illumination efficiency. However, conventional confocal systems had a weak point in that it has to perform XY axis scanning to achieve FOV (Field of View) vision through spot scanning. There are some methods to improve this problem involving the use of a galvano mirror [1], pin-hole array, etc. Therefore, in this paper we propose a method to improve a parallel mode confocal system using a micro-lens and pin-hole array in a dual microscope configuration. We made an area scan possible by using a combination MLA (Micro Lens Array) and pin-hole array, and used an objective lens to improve the light transmittance and signal-to-noise ratio. Additionally, we made it possible to change the objective lens so that it is possible to select a lens considering the reflection characteristic of the measuring object and proper magnification. We did an experiment using 5X, 2.3X objective lens, and did a calibration of height using a VLSI calibration target.

지상기준점을 이용한 디지털카메라 Boresight Calibration (Digital Photogrammetry Camera Boresight Calibration Using Ground Control Points)

  • 이용욱
    • 한국측량학회지
    • /
    • 제32권4_1호
    • /
    • pp.293-298
    • /
    • 2014
  • 최근의 항공사진측량은 디지털항공사진 카메라와 GPS/ INS를 결합한 통합 센서를 활용하여 Direct Georeferencing 하는 방법이 보편화됐으며, 이를 기반으로 신속하고 정확하게 사진측량을 수행할 수 있게 되었다. Direct Georeferencing을 통해 얻을 수 있는 외부표정요소의 정확도는 GPS/INS에 의해 결정되는데, INS의 회전량 차이를 결정하여 자세정보를 정확하게 계산하는 것이 중요하다. 이를 위해 Boresight Calibration으로 INS의 회전량 차이 및 GPS와 INS 간의 간격과 같은 Misalignment를 결정해야 한다. 이때 많은 수의 지상기준점을 이용하여 항공삼각측량과 Boresight Calibraiton을 하게 되는데, 지상기준점의 수와 배열, 위치에 따라 그 결과가 다르게 나타난다. 연구 결과 모든 사진코스에 지상기준점을 배치할 경우 점수의 변화에 따른 Misalignment와 외부표정요소는 큰 변화가 없었으나 지상기준점이 없는 코스가 있을 경우 그 값들에서 차이가 크게 발생하였다.

렌즈왜곡효과를 보상하는 새로운 Hand-eye 보정기법 (A New Hand-eye Calibration Technique to Compensate for the Lens Distortion Effect)

  • 정회범
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집A
    • /
    • pp.596-601
    • /
    • 2000
  • In a robot/vision system, the vision sensor, typically a CCD array sensor, is mounted on the robot hand. The problem of determining the relationship between the camera frame and the robot hand frame is refered to as the hand-eye calibration. In the literature, various methods have been suggested to calibrate camera and for sensor registration. Recently, one-step approach which combines camera calibration and sensor registration is suggested by Horaud & Dornaika. In this approach, camera extrinsic parameters are not need to be determined at all configurations of robot. In this paper, by modifying the camera model and including the lens distortion effect in the perspective transformation matrix, a new one-step approach is proposed in the hand-eye calibration.

  • PDF

FM 방송 기반 멀티스태틱 PCL 시스템 원형 배열 안테나 보정을 위한 Array Manifold 측정 및 검증 (Array Manifold Measurement and Verification for UCA Calibration in Multistatic PCL System based on FM Broadcasting)

  • 박준식;심홍석;안준일;송규하
    • 한국군사과학기술학회지
    • /
    • 제24권2호
    • /
    • pp.165-174
    • /
    • 2021
  • This study describes a method of measurement and verification of array manifold of uniform circular array antenna applicable to multistatic Passive Coherent Location(PCL) system using FM broadcasting. In an environment of outdoor test where FM broadcast signals are scattered, array manifold measurement methods using network analyzer and multi-channel digital receiver are introduced. Also, the descriptions and solutions for the test limits of each measurement method and the considerations affecting the measurement accuracy are presented. In addition, to verify the validity of the measured array manifold, the gain and phase difference were compared with the array manifold data obtained by EM simulation, and the effectiveness and accuracy of the measured array manifolds were compared and analyzed by estimating the direction of arrival of the FM broadcast signal received from the multistatic PCL system.

Averaging Current Adjustment Technique for Reducing Pixel Resistance Variation in a Bolometer-Type Uncooled Infrared Image Sensor

  • Kim, Sang-Hwan;Choi, Byoung-Soo;Lee, Jimin;Lee, Junwoo;Park, Jae-Hyoun;Lee, Kyoung-Il;Shin, Jang-Kyoo
    • 센서학회지
    • /
    • 제27권6호
    • /
    • pp.357-361
    • /
    • 2018
  • This paper presents an averaging current adjustment technique for reducing the pixel resistance variation in a bolometer-type uncooled infrared image sensor. Each unit pixel was composed of an active pixel, a reference pixel for the averaging current adjustment technique, and a calibration circuit. The reference pixel was integrated with a polysilicon resistor using a standard complementary metal-oxide-semiconductor (CMOS) process, and the active pixel was applied from outside of the chip. The averaging current adjustment technique was designed by using the reference pixel. The entire circuit was implemented on a chip that was composed of a reference pixel array for the averaging current adjustment technique, a calibration circuit, and readout circuits. The proposed reference pixel array for the averaging current adjustment technique, calibration circuit, and readout circuit were designed and fabricated by a $0.35-{\mu}m$ standard CMOS process.

어레이 센서 위치보정 알고리즘을 적용한 광대역 다중 신호원 빔형성에서 새로운 신호원의 도래방향 추정 (DOA Estimation of New Appearing Source in Wideband Multisource Beamforming with Array Sensor Position Calibration Algorithm)

  • 심재광;강성현;윤원식
    • 한국음향학회지
    • /
    • 제18권3호
    • /
    • pp.49-54
    • /
    • 1999
  • 본 논문에서는 어레이 센서 위치보정 알고리즘을 적용한 광대역 다중 신호원 빔형성 및 추적에 있어서 새로운 신호원이 검출되었을 때 초기 도래방향을 추정하는 새로운 방법을 제안한다. 초기 도래방향 추정에 있어 빔패턴 형성식을 이용함으로써 추정오차를 추적범위 내에 있도록 한다. 제안한 방법은 추정 도래방향 각의 해상도를 조정할 수 있으므로 주엽폭 특성이 다른 다양한 빔형성기에 적용할 수 있다. 모의 시험을 통하여 양호한 신호원 검출 및 추적성능을 확인하였다.

  • PDF

Calibration of Measurement of Multiple Polarization Singularities

  • Yu, Renlong;Xin, Yu;Zhao, Shuan;Zhao, Qi;Chen, Yanru
    • Journal of the Optical Society of Korea
    • /
    • 제19권4호
    • /
    • pp.397-402
    • /
    • 2015
  • In this paper, we propose a method used to measure the polarization state of a field with multiple polarization singularities (PSs), such as an array of PSs and PSs in vector speckle. A checkerboard is used to construct characteristic points, which makes it possible to calibrate the mismatches between pictures obtained during the rotation of a quarter-wave plate and a polarizer. Using this method a field with an array of PSs is measured. The experimental result is compared with the numerical simulation. We also carry out some data analysis. The comparison and analysis emphasize the necessity and feasibility of this method to measure the PSs.

어레이 마이크로폰용 광대역 소형 위상교정기의 설계 (Design of the broadband and compact phase-calibrator for array microphones)

  • 주형식;김양한
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.1032-1035
    • /
    • 2004
  • Pressure distribution is measured by way microphones to identify noise sources in the space. For example, beam-forming method or acoustic holography use phase information to identify the source. Therefore, the phase is significant information to correctly identify the source position. However, due to the microphone characteristics and measuring systems, measured signals always have errors, which make the identification difficult. Therefore, phase calibration of microphones is needed. Duct and speaker systems are generally used as calibrators. Acoustic characteristics of the calibrator are, of course, functions of many Parameters of the system: i.e. duct size, frequency, and microphone spacing. In this paper, design parameters which effect on the performance and size of the calibrators are considered. Then the parameters would be applied to design and real product of the phase-calibrator.

  • PDF

RECTIFICATION OF PURE TRANSLATION 2D CAMERA ARRAY

  • Ota, Makoto;Fukushima, Norishige;Yendo, Tomohiro;Tanimoto, Masayuki;Fujii, Toshiaki
    • 한국방송∙미디어공학회:학술대회논문집
    • /
    • 한국방송공학회 2009년도 IWAIT
    • /
    • pp.659-663
    • /
    • 2009
  • In this paper, we propose a rectification method that can convert ray space data obtained by controlled camera array to ideal data. Here, Ideal data is obtained by getting longitudinal and transversal epipolar line between cameras vertical and horizontal. However it is actually difficult to arrange cameras strictly because we arrange cameras by hand. As conventional method, we have use camera-calibration method. But if we use this method there are some errors on the output image. When we generate arbitrary viewpoint images this error is critical problem. We focus attention on ideal trajectory of characteristic point. And to minimize the error directly we parallelize the real one. And we showed usefulness of proposed technique. Then using the proposed technique, we were successful reducing the error to less than 0.5 pixels.

  • PDF