• Title/Summary/Keyword: Array Transducer

Search Result 198, Processing Time 0.023 seconds

Acoustic Characteristics Analysis of the Axi-symmetric Transducer by the combined Finite Element Method and Hybrid Type Infinite Element Method, Part II : Wideband Array Transducer Design and its Acoustic Characteristics (유한요소법과 하이브리드형 무한요소법의 결합에 의한 축대칭 변환기의 음향 특성해석(II) ;광대역 배열 변환기의 설계 및 그 음향특성)

  • Kim, Chun-Duck;Kim, Won-Ho;Kim, Dae-Whan;Yoon, Jong-Rak
    • The Journal of the Acoustical Society of Korea
    • /
    • v.13 no.2
    • /
    • pp.68-75
    • /
    • 1994
  • This is the second of two companion papers wich describes the wideband array transducer design procedure and the designed transducer acoustic characteristics. In addition, the result of the designed transducer acoustic characteristics by the combined Finite Element Method and Hybrid Type Infinite Element Method, is found to better than that by the equivalent circuit model method. Therefore, the technique presented in this paper could be applied in the design and the acoustic characteristics analysis of the wideband array transducer.

  • PDF

A Study on the Cross Talk Level in a Piezoelectric Ultrasonic Array Transducer (압전형 초음파 배열 변환기의 음향간섭 레벨에 관한 연구)

  • 이수성;김영신;노용래
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.1
    • /
    • pp.56-61
    • /
    • 2002
  • In piezoelectric ultrasonic linear array transducers widely used for diagnosis, the cross talk caused by the structural cross-coupling between adjacent elements inside the transducer affects the probe performance in a significant manner. In this study, we constructed a finite element model of a piezoelectric ultrasonic transducer, and analyzed its cross talk level with respect to the shape of and materials inside the kerf, The results of this work can be utilized in optimal design of the transducers for medical diagonosis and treatment as well as W applications.

Computation of the Mutual Radiation Impedance in the Acoustic Transducer Array: A Literature Survey

  • Paeng, Dong-Guk;Bok, Tae-Hoon;Lee, Jong-Kil
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.2E
    • /
    • pp.51-59
    • /
    • 2009
  • Mutual radiation impedance becomes more important in the design and analysis of acoustic transducers for higher power, better beam pattern, and wider bandwidth at low frequency sonar systems. This review paper focused on literature survey about the researches of mutual radiation impedance in the acoustic transducer arrays over 60 years. The papers of mutual radiation impedance were summarized in terms of transducer array structures on various baffle geometries such as planar, cylindrical, spherical, conformal, spheroidal, and elliptic cylindrical arrays. Then the computation schemes of solving conventional quadruple integral in the definition of mutual radiation impedance were surveyed including spatial convolution method, which reduces the quadruple integral to a double integral for efficient computation.

Design of a wideband cymbal transducer array (광대역 심벌 트랜스듀서 배열 설계)

  • Kim, Donghyun;Roh, Yongrae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.39 no.3
    • /
    • pp.170-178
    • /
    • 2020
  • Cymbal transducers are often used as an array rather than single because they have a high quality factor and low energy conversion efficiency. When used as an array, there occurs a big change in the frequency characteristics of the array due to the interaction between constituent transducers. In this study, we designed the structure of a cymbal transducer array to have ultra-wideband characteristics using this property. First, cymbal transducers with specific center frequencies were designed. Then, a 2×2 planar array was constructed with the designed transducers, where the cymbal transducers were arranged to have same or opposite polarization directions. For this structure, we analyzed the effect of the difference in the center frequency of and the spacing between the constituent transducers on the acoustical characteristics of the array. Based on the analysis, we designed the structure of the cymbal transducer array to have the widest possible bandwidth.

Design and fabrication of a 20 MHz high frequency linear array ultrasonic transducer for medical use (20 MHz 의료용 고주파 선형 배열 초음파 트랜스듀서의 설계 및 제작)

  • Lee, Wonseok;Roh, Yongrae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.35 no.6
    • /
    • pp.466-472
    • /
    • 2016
  • In this work, a medical linear array ultrasonic transducer working in the range of 20 MHz has been developed for high-resolution ultrasonic imaging. After devising the structure of the transducer suitable for the transmission of high-frequency waves, we optimized the dimension of constituent components. Then, the process to fabricate the transducer was developed to realize the designed structure, and a prototype of the transducer was fabricated and characterized. The center frequency of the fabricated transducer was measured to be 19 MHz, and the fractional bandwidth to be 84.5 %, and the standard deviation of the sensitivity over the entire channels to be 0.74 dB. These measurement results showed good agreement with design data, which confirmed the validity of the high frequency ultrasonic transducer structure developed in this work. It was confirmed that the developed transducer with new structure had wider frequency bandwidth and uniform sensitivity than a conventional 20 MHz transducer.

A Study on an Ultrasonic Phased Array Transducer with a Spherical Liquid Lens (구면 액체 렌즈 초음파 위상 배역 변환기에 관한 연구)

  • 윤영중;박한규
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.11
    • /
    • pp.9-16
    • /
    • 1995
  • In this paper, an ultrasonic phased array transducer with spherical liquid lens, which utilizes both electronic focusing by linear phased array and variable geometric focusing by spherical lens. is investigated. This system reduces the elevational beamwidth which is disadvantage of the 1-dimensional linear phased array, and adds real-time dynamic focusing capability by controlling the volume of liquid in the lens. A prototype of this transducer is constructed and tested. The experimental results are compared with those of computer simulations. The range of applications are in the hyperthermia applicators or ultrasonic image system with narrow beam and rapid scanning characterisitcs.

  • PDF

Design and Fabrication of Linear Array Transducer for Ultrasonic Medical Imaging System (초음파 의료 진단 장치용 선형 배열 변환기의 설계 및 제작)

  • Cho, Yeong-Hwan;Sung, Keong-Mo
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1990 no.05
    • /
    • pp.29-32
    • /
    • 1990
  • In this paper, we designed and fabricated linear array transducer for ultrasonic medical imaging system. Fabricated transducer is 85mm in length and has 64 elements. It shows good sensitivity and band width characteristics compared with commercial transducers.

  • PDF

A Study on The transducer of acoustic sensor to be Single-mode FBG using Hopper Type WDM be in the Making (Hopper type WDM을 이용한 단일모드 FBG(Fiber Bragg Grating)음향센서 트랜스듀서 개발연구)

  • Kim, Kyung Bok
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.10
    • /
    • pp.256-263
    • /
    • 2014
  • We have designed and made three kinds of FBG(Fiber Bragg Grating) Acoustic Transducer using Hopper type WDM on the use of recently developed FBG in Korea. The newly designed three kinds of FBG Acoustic Transducer using Hopper type WDM have an excellent merit of practical use with simple structure of sensors arm as well as the merit with existing fiber sensors. It was possible to detect sound waves in the range of 10 Hz to 18 kHz through the newly designed three kinds of FBG Acoustic Transducer and also, possible to detect its signal within the maximum range of 8.6 m by the use of most suitable resonance condition of the transducer. Especially, we can expect the utilization of low-frequency signal detection instead of existing acoustic sensor in the environment of electric noise and inferior condition. Furthermore, they can be developed as the high-sensibility and multi-point signal detection system through the sensor array system.

Improvement of the Directivity of a Doppler Log Using Linear Transducer Array (직선배열 진동자에 의한 도풀러 로그의 지향특성 개선에 관한 연구)

  • 신형일;정세모
    • Journal of the Korean Institute of Navigation
    • /
    • v.5 no.2
    • /
    • pp.1-39
    • /
    • 1981
  • A doppler log is the typical device which can measure the ship's speed over the ground directly, by means of doppler effect of the underwater ultrasonic wave, which involves the error due to the sea bottom inclination, the trim and the incorrect transducer installation etc. The present doppler log adopts a single transducer, faced in the direction of themain beam, and therefore it is unable to correct the beam direction to eliminate the above mentioned error. Moreover, the frequencyis also limitted in a comparatively high range for getting a sharp beam with single transducer, and the speed over the ground can not be detectable at the deep sea, for an instance, over 200 meters. This paper describes a theoretical consideration for the doppler log error and an analysis by a computer on the observed speed data by a full size model ship. The result is verified that the most of doppler log error is caused by the ultrasonic beam angle of transducer. To eliminate the doppler log error due to the incorrect transducer installation and also to sharpen the beam for lower frequency range to expand measurable sea depth, this paper proposes a method of controlling the directivity adopting a linear transducer array and of controlling the directivity by the control of exciting current, and investigates by the computer simulation and make experiment with magnetostrictive ferrite transducer of 28, 50 and 75KHz. The experimental results are shown well coincide with the measured ones, and they are revealed that in case where the transducer interval is greater than 1 wavelength, the effective control of the beam direction is hardly performed with keeping adequate beam width and side lobe level. It is concluded that 6-elements array with inter element space of a half wavelength can make comparatively sharp beam and low side lobe level. The results obtained here will contribute very much to the improvement of the performance of doppler log.

  • PDF

Properties of PZT Ultrasonic Transducer Array Fabricated by Micro-Pressing and Dicing method (Micro-Pressing 방법과 Dicing 방법에 의해 제조된 PZT Ultrasonic Transducer Array의 특성)

  • Park, Joon-Shik;Hong, Sung-Jei;Cho, Jin-Woo;Park, Soon-Sup;Han, Jin-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2248-2250
    • /
    • 2000
  • We investigated properties of PZT composite for medical ultrasonic transducer array (briefly UTA) for medicine applications fabricated by micro pressing and dicing method. Dicing method was the fabrication process of conventional ultrasonic transducer array by dicing sintered PZT sheet. Micro pressing method was the proposed process using pressing PZT green sheet by PMMA micro mold from LIGA process. Microstructures, electrical and electro -mechanical properties of fabricated UTAs of two cases were analyzed. Thickness mode electro-mechanical coupling coefficient of two cases have same values of 51%. Sintered PZT Microstructures of them showed dense and uniform. Micro pressing method was very mass productive process because of using batch type LIGA process. From results, we found micro pressing method was more competitive than dicing method for UTA fabrication. For further study, uniformity of microstructures and electro-mechanical properties of large scale, and fabrication processes of Ni plating and PMMA molding should be improved and investigated.

  • PDF