• 제목/요약/키워드: Array Probe

검색결과 218건 처리시간 0.029초

초소형 고밀도 정보저장장치를 위한 고종횡비의 팁을 갖는 정전 구동형 폴리 실리콘 프로브 어레이 개발 (Electrostatically-Driven Polysilicon Probe Array with High-Aspect-Ratio Tip for an Application to Probe-Based Data Storage)

  • 전종업;이창수;최재준;민동기;전동렬
    • 한국정밀공학회지
    • /
    • 제23권6호
    • /
    • pp.166-173
    • /
    • 2006
  • In this study, a probe array has been developed for use in a data storage device that is based on scanning probe microscope (SPM) and MEMS technology. When recording data bits by poling the PZT thin layer and reading them by sensing its piezoresponse, commercial probes of which the tip heights are typically shorter than $3{\mu}m$ raise a problem due to the electrostatic forces occurring between the probe body and the bottom electrode of a medium. In order to reduce this undesirable effect, a poly-silicon probe with a high aspect-ratio tip was fabricated using a molding technique. Poly-silicon probes fabricated by the molding technique have several features. The tip can be protected during the subsequent fabrication processes and have a high aspect ratio. The tip radius can be as small as 15 nm because sharpening oxidation process is allowed. To drive the probe, electrostatic actuation mechanism was employed since the fabrication process and driving/sensing circuit is very simple. The natural frequency and DC sensitivity of a fabricated probe were measured to be 18.75 kHz and 16.7 nm/V, respectively. The step response characteristic was investigated as well. Overshoot behavior in the probe movement was hardly observed because of large squeeze film air damping forces. Therefore, the probe fabricated in this study is considered to be very useful in probe-based data storages since it can stably approach toward the medium and be more robust against external shock.

해안연약 지반 조사를 위한 4전극 전기비저항 프로브 (4 Electrical Resistivity Probe for Investigating soft offshore soils)

  • 김준한;윤형구;배명호;정순혁;이종섭
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 춘계 학술발표회
    • /
    • pp.464-475
    • /
    • 2009
  • Electrical resistivity can be used for porosity estimation. In order to improve previously developed ERCP(Electrical Resistivity Cone Probe), 4ERP(4 Electrical Resistivity Probe), which has Wenner array at the tip of probes, has been developed. In properties of current flow Wenner array measures electrical properties of undisturbed area during penetration and relatively correct measurements are guaranteed without polarization. Furthermore, Wenner array equation can estimate electrical resistivity without extra calibration. 4ERP is developed into 2 types, penetration and fixation. Penetration type has wedge-shaped tip. Considering disturbance minimization, fixed type has plane tip. Fixed type 4ERP in consolidation cell measure electrical resistivity increment along porosity decrease, and penetration type 4ERP measured resistivity profile along the depth in chamber. Applying Archie's law, porosity profile was estimated with electrical resistivity. The tests result suggests that 4ERP can be new site investigation equipment with little disturbance.

  • PDF

Probe로 급전되는 적층형 원형 마이크로스트립 2소자 배열 안테나의 임피던스 및 상호 결합 특성 (Impedance and Mutual Coupling Characteristics of a Probe-Fed Stacked Circular Microstrip Two-Element Array Antenna)

  • 이면주;남상욱
    • 한국통신학회논문지
    • /
    • 제18권11호
    • /
    • pp.1767-1773
    • /
    • 1993
  • 본 논문에서는 probe로 급전되는 적층형 마이로스트립 2소자 배열 안테나의 임피던스 및 결합특성을 제시하였다. 안테나 구조의 해석에는 벡터 한켈 변환을 이용한 스팩트럴 영역법을 적용하였다. 또한 이 안테나의 임피던스 및 결합특성, 그리고 두 소자 안테나간의 거리에 따른 결합특성 변화등을 측정하여 그 결과를 제시한다. 끝으로, 해석을 통해 계산된 결과와 측정된 결과를 비교하여 두 결과가 잘 일치함을 보였다.

  • PDF

Quality Control Probes for Spot-Uniformity and Quantitative Analysis of Oligonucleotide Array

  • Jang, Hyun-Jung;Cho, Mong;Kim, Hyung-Hoi;Kim, Cheol-Min;Park, Hee-Kyung
    • Journal of Microbiology and Biotechnology
    • /
    • 제19권7호
    • /
    • pp.658-665
    • /
    • 2009
  • Quality control QC for spot-uniformity is a critical point in fabricating an oligonucleotide array, and quantification of targets is very important in array analysis. We developed two new types of QC probes as a means of confirming the quality of the uniformity of attached probes and the quantification of targets. We compared the signal intensities and fluorescent images of the QC and target-specific probes of arrays containing only target-specific probes and those containing both QC and target-specific probes. In a comparison of quality control methods, it was found that the arrays containing QC probes could check spot-uniformity or spot defects during all processes of array fabrication, including after spotting, after washing, and after hybridization. In a comparison of quantification results, the array fabricated by the method using QC probes showed linear and regular results because it was possible to normalize variations in spot size and morphology and amount of attached probe. This method could avoid errors originating in probe concentration and spot morphology because it could be normalized by QC probes. There were significant differences in the signal intensities of all mixtures (P<0.05). This result indicates that the method using QC probes is more useful than the ordinary method for quantification of mixed target. In the quantification of mixed targets, this method could determine a range for mixed targets of various amounts. Our results suggest that methods using QC probes for array fabrication are very useful to the quality control of spots in the fabrication processes of quantitative oligonucleotide arrays.

Optimal design of slider for stable flying characteristic using 4${\times}$l near-field probe array

  • Jung Min-su;Hong Eo-Jin;Park Kyoung-Su;Park No-Cheol;Yang Hyun-Seok;Park Young-Pil;Lee Sung-Q;Park Kang-Ho
    • 정보저장시스템학회:학술대회논문집
    • /
    • 정보저장시스템학회 2005년도 추계학술대회 논문집
    • /
    • pp.171-176
    • /
    • 2005
  • In the information storage development, the trend of the storage device is to increase the recording density. Among such an effort, near-field probe recording is spotlighted as a method of high increasing recording density. For the successfully embodiment of storage device, the actuating mechanism of near-field probe is essentially designed. In this paper, we suggest the slider similar with conventional HDDs and design the slider using near- field probe for the purpose of applying the slider in order to control gap between probe and media. The most important object of slider design is to guarantee the flying ability and stability. For achievement of these design objects, we perform two step of optimal design process. The media is mod! eled as random displacement, which is only considered roughness of disk surface. The design slider is analyzed with dynamic state in assumed media. At this process, the optimal model is confirmed to stable flying stability.

  • PDF

Optimal Design of Slider for Stable Flying Characteristics using $4{\times}1$ Near-field Probe Array

  • Jung, Min-Su;Hong, Eo-Jin;Park, Kyoung-Su;Park, No-Cheol;Yang, Hyun-Seok;Park, Young-Pil;Lee, Sung-Q;Park, Kang-Ho
    • 정보저장시스템학회논문집
    • /
    • 제2권1호
    • /
    • pp.65-70
    • /
    • 2006
  • In the information storage development, the trend of the storage device is to increase the recording density. Among such an effort, near-field probe recording is spotlighted as a method of high increasing recording density. For the successfully embodiment of storage device, the actuating mechanism of near-field probe is essentially designed. In this paper, we suggest the slider similar with conventional HDD and design the slider using near-field probe for the purpose of applying the slider in order to control gap between probe and media. The most important object of slider design is to guarantee the flying ability and stability. For achievement of these design objects, we perform two step of optimal design process. The media is supposed to model as random displacement, which is only considered roughness of disk surface. The design slider is analyzed with dynamic state in assumed media. At this process, the optimal model is confirmed to stable flying stability.

  • PDF

능동 폴리머 펜 어래이를 이용한 미세 패터닝 (Micro Patterning Using Active Polymer Pen Array)

  • 한윤수;홍지화
    • 한국전기전자재료학회논문지
    • /
    • 제26권12호
    • /
    • pp.853-857
    • /
    • 2013
  • We design, develope and test a parallel active polymer pen lithography (PPL) device, which consists of individually addressable elastomeric probe tips. The PPL array chip is fabricated using soft lithography method with polydimethylsiloxane (PDMS) material. Individual probe can be pneumatically actuated via a computer controlled interface. We demonstrate parallel writing with 16 individually addressed pens, with each pen producing a different pattern in the same run. The largest proof-of-concept array fabricated is $4{\times}4$ with a spacing of $250{\mu}m$ in both x and y axes.

PCS 기지국용 U-슬롯 어레이 안테나 설계 (Design of U-slot Array for OCS Base Station)

    • 한국전자파학회논문지
    • /
    • 제12권1호
    • /
    • pp.117-124
    • /
    • 2001
  • 본 논문에서는 PCS 기지국요 U-슬롯 어레이 안테나 설계가 실행 및 연구되었다. U-슬롯 안테나는 안테나의 부피가 작은 단층 형태이나 기생 패치를 이용하는 설계보다 더넓은 대역폭을 얻을 수 있으며 probe 급전의 경우에 17%이상의 대역폭을 얻을 수 있다. 설계도니 U-슬롯 어레이 안테나는 PCS 주파수 대역에서 12dB이상의 평균 이득과 안정적인 복사패턴을 가지고 있다. 본 논문에서 U-슬롯 어레이 안테나의 설계를 통하여 PCS를 기지국용 안테나로의 이용 가능성을 제시하였다.

  • PDF

$8{\times}1$ 다중코일 와전류탐촉자를 이용한 원전 증기발생기 전열관 단면형상검사 기법 개발 (Development of Profile Technique for Steam Generator Tubes in Nuclear Power Plants Using $8{\times}1$ Multi-Array Eddy Current Probe)

  • 남민우;이희종;김철기
    • 비파괴검사학회지
    • /
    • 제28권2호
    • /
    • pp.184-190
    • /
    • 2008
  • 원전 증기발생기 전열관의 건전성을 평가하기 위해서 여러 가지 와전류검사 기법이 적용되고 있다. 이와 같은 와전류검사 기법중에서 보빈탐촉자 기법은 전열관에 발생할 수 있는 축방향균열, 마모 검사에 적용하고 있으며, MRPC 기법은 튜브시트 상단 및 곡관부위 균열의 정밀검사에 적용된다. 원전 증기발생기 전열관의 설치공정 혹은 운전중에 전열관에 덴트(dent, 혹은 ding) 및 벌지(bulge)가 형성될 수 있으며, 와전류검사에서 이러한 지시는 결함으로 간주하지 않기 때문에 일정 크기 이상의 지시만 검사보고서에 기록하여 관리하고 있다. 이러한 지시는 보빈탐촉자 기법으로 용이하게 검출이 가능하고 보빈단면형상검사에 의해 대략적인 크기의 측정이 가능하지만, 정확한 크기 및 형상은 알 수는 없으므로 본 연구에서는 단면형상검사의 정확도를 증가시키기 위해 $8{\times}1$ 다중코일 탐촉자를 설계 개발하여 그 정확도를 평가하였다. 한편, OPR-1000형 증기발생기 전열관의 튜브시트 확관 천이영역에 형성된 덴트부위에 균열성 결함이 발생할 가능성이 높기 때문에 일부 발전소에서는 예방차원의 슬리빙을 수행하고 있다 이와 같은 슬리빙 대상 전열관 선정시 본 검사기법을 활용하면 유용할 것으로 판단된다.

Micro Hall probe array를 이용한 YBa$_2Cu_3O_7$ 단결정 내부의 자속 운동 측정 (Vortex dynamics in YBa$_2Cu_3O_7$ single crystals measured by micro Hall-probe array)

  • 심성엽;황현국;이창우;이태원;김동호
    • 한국초전도학회:학술대회논문집
    • /
    • 한국초전도학회 1999년도 High Temperature Superconductivity Vol.IX
    • /
    • pp.189-195
    • /
    • 1999
  • We have studied the vortex dynamics in YBa$_2Cu_3O_7$ single crystals with columnar defects using micro Hall-probe array. The Hall-probe array technique allowed a simultaneous measurement of the time and spatial dependence of the vortex density so that more detailed information on flux dynamics could be obtained. We found that field profiles inside sample were similar to the Bean's critical state model from the magnetic hysteresis measurement. Normalized relaxation rates were maximum near the center and decreased toward the edge if applied field H$_{app}$ is greater than the penetration field H. But applied magnetic field H$_{app}$ is less than H, relaxation rates were minimum near the center and increased toward edge. We found that glassy exponent ${\mu}$ has the value of ${\sim}$ 1 whose corresponding vortex motion is half-loop excitation. However, single vortex creep, ${\mu}$ ${\sim}$ 1/7, was also found at 30 K and H$_{app}$ ${\cong}$ H'. Calculation of activation energy, U, was possible from direct analysis of the local relaxation data using the basic diffusion equation. From these results, we found that U increases logarithmically with time and U around center was lower than that at the edge.

  • PDF