• 제목/요약/키워드: Argon plasma

검색결과 320건 처리시간 0.029초

소화기 종양에 대한 내시경적 완화치료 (The Role of Endoscopic Interventions in Palliative Care for the Gastrointestinal Tumors)

  • 김혜강;정대영
    • Journal of Digestive Cancer Research
    • /
    • 제2권1호
    • /
    • pp.1-4
    • /
    • 2014
  • Palliative care for cancer aims to relieve the discomfort and pain from the cancer itself and associated conditions. Gastrointestinal cancers originate from the tube like structure of gastrointestinal tract and cause complications such as obstruction, bleeding, adhesion, invasion, and perforation to adjacent organ. Recent advances in interventional endoscopy enables endoscopy physicians to do safe and effective care for gastrointestinal cancer patients. Endoscopic palliation includes stent, hemostasis, nutritional support and targeted drug delivery. Self expandable metallic stent is one of the most important modalities in gastrointestinal palliation. Through the endoscopy or over the wire pre-placed by endoscopy, stents restore the gastrointestinal luminal patency and relieve the obstructive condition. Endoscopic hemostasis is another important palliation in gastrointestinal cancer patients. Epinephrine injection, argon plasma coagulation and thermal cauterization are usual modalities for hemostasis. Histoacryl glue and fibrin glue are also available. Hemostatic nanopowder spray is newly reported effective in benign disease and is supposed to be effective also in cancer bleeding. Enteral feeding tubes including gastro- or jejunostomy and nosoduodenal tubes are placed by using endoscopic guidance. Enteral feeding tubes role as the route of easily absorbable or semi-digested nutrients and effectively maintain both patients calorie requirements and gut microenvironment. Photodynamic therapy is the one of the outstanding medical employments of photo-physics. Especially for superficial cancers in esophagus, photodynamic therapy is very useful in cancer removal and maintaining organ structure. In biliary neoplasm, photodynamic therapy is well known to be effective in cancer ablation and biliary ductal patency restoration. Targeted drug delivery is the lastest issue in palliative endoscopy. Debates and questions are still on the table. In this article, the role of endoscopic interventions in palliative care for the gastrointestinal tumors will be thoroughly reviewed.

  • PDF

Effects of SPS Mold on the Properties of Sintered and Simulated SiC-ZrB2 Composites

  • Lee, Jung-Hoon;Kim, In-Yong;Kang, Myeong-Kyun;Jeon, Jun-Soo;Lee, Seung-Hoon;Jeon, An-Gyun;Shin, Yong-Deok
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권6호
    • /
    • pp.1474-1480
    • /
    • 2013
  • Silicon carbide (SiC)-zirconium diboride ($ZrB_2$) composites were prepared by subjecting a 60:40 vol% mixture of ${\beta}$-SiC powder and $ZrB_2$ matrix to spark plasma sintering (SPS) in 15 $mm{\Phi}$ and 20 $mm{\Phi}$ molds. The 15 $mm{\Phi}$ and 20 $mm{\Phi}$ compacts were sintered for 60 sec at $1500^{\circ}C$ under a uniaxial pressure of 50 MPa and argon atmosphere. Similar composites were simulated using $Flux^{(R)}$ 3D computer simulation software. The current and power densities of the specimen sections of the simulated SiC-$ZrB_2$ composites were higher than those of the mold sections of the 15 $mm{\Phi}$ and 20 $mm{\Phi}$ mold simulated specimens. Toward the centers of the specimen sections, the current densities in the simulated SiC-$ZrB_2$ composites increased. The power density patterns of the specimen sections of the simulated SiC-$ZrB_2$ composites were nearly identical to their current density patterns. The current densities of the 15 $mm{\Phi}$ mold of the simulated SiC-$ZrB_2$ composites were higher than those of the 20 $mm{\Phi}$ mold in the center of the specimen section. The volume electrical resistivity of the simulated SiC-$ZrB_2$ composite was about 7.72 times lower than those of the graphite mold and the punch section. The power density, 1.4604 $GW/m^3$, of the 15 $mm{\Phi}$ mold of the simulated SiC-$ZrB_2$ composite was higher than that of the 20 $mm{\Phi}$ mold, 1.3832 $GW/m^3$. The $ZrB_2$ distributions in the 20 $mm{\Phi}$ mold in the sintered SiC-$ZrB_2$ composites were more uniform than those of the 15 $mm{\Phi}$ mold on the basis of energy-dispersive spectroscopy (EDS) mapping. The volume electrical resistivity of the 20 $mm{\Phi}$ mold of the sintered SiC-$ZrB_2$ composite, $6.17{\times}10^{-4}{\Omega}cm$, was lower than that of the 15 $mm{\Phi}$ mold, $9.37{\times}10^{-4}{\Omega}{\cdot}cm$, at room temperature.

이온빔 및 이미다졸-실란 화합물에 의한 폴리이미드 필름과 구리의 접착 특성 (Adhesion Properties between Polyimide Film and Copper by Ion Beam Treatment and Imidazole-Silane Compound)

  • 강형대;김화진;이재흥;서동학;홍영택
    • 접착 및 계면
    • /
    • 제8권1호
    • /
    • pp.15-27
    • /
    • 2007
  • 폴리이미드 필름과 구리의 접착력을 향상시키기 위하여 이온빔과 실란-이미다졸 커플링제를 사용하여 폴리이미드 표면개질을 실시하였다. 실란-이미다졸 커플링제는 구리와의 배위결합을 형성하는 이미다졸 그룹과 실록산 폴리머를 형성하는 메톡시 실란 그룹을 함유한다. 폴리이미드 필름표면은 아르곤/산소 이온빔으로 일차로 처리하여 친수성을 높인 폴리이미드 필름에 커플링제 수용액에 침지하여 폴리이미드 필름 표면에 커플링제를 그라프트시켜 표면개질을 실시하였다. XPS 스펙트럼 분석결과 아르곤/산소 플라즈마 처리는 폴리이미드 표면에 하이드록시 및 카르보닐 그룹과 같은 산소 기능성기를 형성함을 알 수 있었고 폴리이미드 필름 표면에 실란-이미다졸과의 커플링반응에 의하여 표면이 개질되었음을 확인하였다. 이온빔을 사용하여 그라프트된 폴리이미드 필름과 구리와의 접착력은 처리되지 않은 폴리이미드 필름과의 접착력 보다 높은 접착력을 나타내었다. 또한 커플링제로 그라프트된 폴리이미드 필름의 접착력 보다 아르곤/산소의 양자화 이온을 이용하여 개질한 그라프트된 폴리이미드 필름의 시편이 더 높은 접착력을 나타내었다. 구리-폴리이미드 필름의 계면으로부터 박리된 층은 분석결과 완전히 서로 다른 화학적 조성을 나타내었는데 이것으로부터 박리가 접합면의 커플링제 내에서 일어나는 것보다는 폴리이미드와 커플링제의 사이에서 일어남을 확인하였다.

  • PDF

PDMS 표면특성에 따른 비균일계 마이크로채널의 유속 변화 (Flow Rate Changes in the Heterogeneous Rectangular Microchannels with Different Hydrophilicity for the PDMS Bottom Surface)

  • 노순영;이효송;김기호;최재호;유재근;윤수경;이영우
    • 청정기술
    • /
    • 제13권3호
    • /
    • pp.195-200
    • /
    • 2007
  • 본 연구에서는 표면특성에 따른 비균일계 마이크로채널에서의 유속 변화를 조사하였다. 비균일계 마이크로채널은 PDMS와 soft lithography를 사용하여 제작하였고, 마이크로채널의 내부 표면 중 아랫면만을 allyl alcohol로 증착하여 친수성을 띠게 하였다. 채널의 길이는 10, 20, 30 mm, 너비는 100, 200, $300\;{\mu}m$로 각각 제작하였으며, 채널 내 전기영동에 의한 흐름을 생성하기 위해 외부전압을 가해주었다. 그 결과 동일한 세기의 전기장과 밑면의 친수성 정도가 동일할 때 유속은 같았다. 이는 이론적 결과에 부합하고, 연구가 신뢰성이 있다는 것을 뒷받침할 수 있었다. 같은 친수성을 갖는 밑면일 때 채널의 너비가 증가할수록 유속도 증가하고, 친수성 정도가 큰 채널이 작은 채널보다 유속이 빨랐다. 이 결과는 밑면의 친수성 정도에 따라 채널 유속을 조절할 수 있다는 것을 의미한다.

  • PDF

탄소계 경질 박막의 연구 및 산업 적용 동향 (Trend in Research and Application of Hard Carbon-based Thin Films)

  • 이경황;박종원;양지훈;정재인
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.111-112
    • /
    • 2009
  • Diamond-like carbon (DLC) is a convenient term to indicate the compositions of the various forms of amorphous carbon (a-C), tetrahedral amorphous carbon (ta-C), hydrogenated amorphous carbon and tetrahedral amorphous carbon (a-C:H and ta-C:H). The a-C film with disordered graphitic ordering, such as soot, chars, glassy carbon, and evaporated a-C, is shown in the lower left hand corner. If the fraction of sp3 bonding reaches a high degree, such an a-C is denoted as tetrahedral amorphous carbon (ta-C), in order to distinguish it from sp2 a-C [2]. Two hydrocarbon polymers, that is, polyethylene (CH2)n and polyacetylene (CH)n, define the limits of the triangle in the right hand corner beyond which interconnecting C-C networks do not form, and only strait-chain molecules are formed. The DLC films, i.e. a-C, ta-C, a-C:H and ta-C:H, have some extreme properties similar to diamond, such as hardness, elastic modulus and chemical inertness. These films are great advantages for many applications. One of the most important applications of the carbon-based films is the coating for magnetic hard disk recording. The second successful application is wear protective and antireflective films for IR windows. The third application is wear protection of bearings and sliding friction parts. The fourth is precision gages for the automotive industry. Recently, exciting ongoing study [1] tries to deposit a carbon-based protective film on engine parts (e.g. engine cylinders and pistons) taking into account not only low friction and wear, but also self lubricating properties. Reduction of the oil consumption is expected. Currently, for an additional application field, the carbon-based films are extensively studied as excellent candidates for biocompatible films on biomedical implants. The carbon-based films consist of carbon, hydrogen and nitrogen, which are biologically harmless as well as the main elements of human body. Some in vitro and limited in vivo studies on the biological effects of carbon-based films have been studied [$2{\sim}5$].The carbon-based films have great potentials in many fields. However, a few technological issues for carbon-based film are still needed to be studied to improve the applicability. Aisenberg and Chabot [3] firstly prepared an amorphous carbon film on substrates remained at room temperature using a beam of carbon ions produced using argon plasma. Spencer et al. [4] had subsequently developed this field. Many deposition techniques for DLC films have been developed to increase the fraction of sp3 bonding in the films. The a-C films have been prepared by a variety of deposition methods such as ion plating, DC or RF sputtering, RF or DC plasma enhanced chemical vapor deposition (PECVD), electron cyclotron resonance chemical vapor deposition (ECR-CVD), ion implantation, ablation, pulsed laser deposition and cathodic arc deposition, from a variety of carbon target or gaseous sources materials [5]. Sputtering is the most common deposition method for a-C film. Deposited films by these plasma methods, such as plasma enhanced chemical vapor deposition (PECVD) [6], are ranged into the interior of the triangle. Application fields of DLC films investigated from papers. Many papers purposed to apply for tribology due to the carbon-based films of low friction and wear resistance. Figure 1 shows the percentage of DLC research interest for application field. The biggest portion is tribology field. It is occupied 57%. Second, biomedical field hold 14%. Nowadays, biomedical field is took notice in many countries and significantly increased the research papers. DLC films actually applied to many industries in 2005 as shown figure 2. The most applied fields are mold and machinery industries. It took over 50%. The automobile industry is more and more increase application parts. In the near future, automobile industry is expected a big market for DLC coating. Figure 1 Research interests of carbon-based filmsFigure 2 Demand ratio of DLC coating for industry in 2005. In this presentation, I will introduce a trend of carbon-based coating research and applications.

  • PDF

일부 농촌지역 노인들의 인지 장애에 관련된 요인에 관한 연구 (A Study on the Factors related to the Cognitive Impairment of the Elderly in a Rural Area)

  • 고광욱;조병만;이수일;김돈균;조봉수;김영욱;김영실;강수용
    • Journal of Preventive Medicine and Public Health
    • /
    • 제29권3호
    • /
    • pp.657-668
    • /
    • 1996
  • 경상남도 일부 지역에서 60세 이상 노인들의 MMSE에 의한 인지 장애 유병률을 조사하고 인지 장애에 영향을 미치는 요인들을 조사하여 다음과 같은 성적을 얻었다. 1. MMSE에 의한 인지 장애의 유병률은 35.9%로 남자에서 18.4%, 여자에서 45.2%였다. 2. 인지 장애 유병률은 여자에서 유의하게 높았고(p=0.02) 무학력자와 문맹자의 인지 장애 유병률이 통계적으로 유의하게 높았다(p=0.03). 3.성별과 교육 수준에 따른 층화 분석에서 알루미늄의 인지 기능에 대한 독성 효과와 칼슘의 보호 효과에 대한 전체적으로 일정한 경향은 관찰되지 않았다(p>0.05). 4. 최종 분석 대상자 전체에서 음용수 중의 알루미늄과 인지 기능 검사 점수간의 상관 계수는 -0.066으로서 미약한 음의 상관관계에 있었으나 통계학적인 유의성은 보이지 않았고(p=0.434), 칼슘과 MMSE 점수와의 관계에서도 기대했던 바의 양의 상관관계는 관찰할 수 없었다.

  • PDF

반도체 접합계면이 가스이온화에 따라 극성이 달라지는 원인 (Dependance of Ionic Polarity in Semiconductor Junction Interface)

  • 오데레사
    • 한국산학기술학회논문지
    • /
    • 제19권6호
    • /
    • pp.709-714
    • /
    • 2018
  • 반도체소자의 접합특성에 따라서 분극의 특성이 달라지는 원인을 조사하였다. 반도체소자의 접합특성은 최종적인 반도체소자의 효율과 관련되기 때문에 중요한 요소이며, 효율을 높이기 위해서는 반도체접합 특성을 이해하는 것은 매우 중요하다. 다양한 성질의 접합을 얻기위하여 n형의 실리콘 위에 절연물질인 carbon doped silicon oxide (SiOC) 박막을 증착하였으며, 아르곤 (Ar) 유량에 따라서 반도체기판의 특성이 달라지는 것을 확인하였다. 전도체인 tin doped zinc oxide (ZTO) 박막을 절연체인 SiOC 위에 증착하여 소자의 전도성을 살펴보았다. SiOC 박막의 특성은 플라즈마에 의하여 이온화현상이 일어날 때 Ar 유량에 따라서 이온화되는 경향이 달라지면서 반도체 계면에서의 공핍현상이 달라졌으며, 공핍층 형성이 많이 일어나는 곳에서 쇼키접합 특성이 잘 형성되는 것을 확인하였다. 아르곤 가스의 유량이 많은 경우 이온화 반응이 많이 일어나고 따라서 접합면에서 전자 홀쌍의 재결합반응에 의하여 전하들이 없어지게 되면 절연특성이 좋아지고 공핍층의 전위장벽이 증가되며, 쇼키접합의 형성이 유리해졌다. 쇼키접합이 잘 이루어지는 SiOC 박막에서 ZTO를 증착하였을 때 SiOC와 ZTO 사이의 계면에서 전하들이 재결합되면서 전기적으로 안정된 ZTO 박막을 형성하고, ZTO의 전도성이 증가되었다. 두께가 얇은 반도체소자에서 흐르는 낮은 전류를 감지하기 위해서는 쇼키접합이 이루어져야 하며, 낮은 전류만으로도 전기신호의 품질이 우수해지고 또한 채널층인 ZTO 박막에서의 전류의 발생도 많아지는 것을 확인하였다.

정류성 접합에 의한 광다이오드의 특성 개선 (The Characteristic Improvement of Photodiode by Schottky Contact)

  • 허창우
    • 한국정보통신학회논문지
    • /
    • 제8권7호
    • /
    • pp.1448-1452
    • /
    • 2004
  • 비정질실리콘은 빛을 받으면 자유전자와 자유정공이 무수히 발생하여 전류 또는 전압의 형태로 나타나는 광전변환 재료이다. 이를 광다이오드로 사용하기 위해서는 금속 박막(Thin film)과 결합하여 쇼트키 다이오드로 만드는 기술이 효과적이다. 본 연구에서는 광다이오드의 신뢰성 및 특성을 개선하기 위하여 크롬실리사이드를 기존의 방식과 달리 하부 전극으로 크롬금속 박막을 증착한 후 그 위에 사일렌(SiH4)가스를 사용해서 PECVD (Plasma Enhanced Chemical Vapor Deposition) 진공 증착장비로 최적의 비정질실리콘 박막을 얇게 (100$\AA$) 만들어 열처리를 통하여 크롬실리사이드 박막을 형성 한 후 광다이오드 소자를 제조한다. 이렇게 형성된 크롬실리사이드 광 다이오드를 사용하여 암전류와 광전류를 측정찬 결과 기존의 방식보다 우수한 성능이 나타났고, 공정도 단순화 할 수 있었으며 그리고 신뢰성도 개선되었다.

임플란트 지대주와 임플란트 주위 연조직의 반응에 관한 고찰 (A literature review on implant abutment and soft tissue response)

  • 이영훈;고경호;허윤혁;박찬진;조리라
    • 구강회복응용과학지
    • /
    • 제32권4호
    • /
    • pp.263-273
    • /
    • 2016
  • 지대주의 재료와 표면에 따라 연조직반응이 다르고 임플란트 주위염의 원인이 될 수 있다. 티타늄과 지르코니아는 우수한 생체적합성을 가져 안정적인 연조직반응을 보이고 금합금은 표면상태에 따라 연조직반응이 다르게 나타난다. 같은 재료라도 표면특성에 따라 연조직반응이 영향을 받는다. 표면거칠기 증가는 박테리아 부착을 유발하므로 연조직과 접촉하는 부분은 평활한 표면을 가져야 한다. 추가적인 표면처리를 통해 박테리아의 부착은 증가시키지 않으면서 세포반응을 촉진시킬 수 있다. 지대주의 형태 및 반복착탈도 연조직반응에 영향을 줄 수 있다. 초음파 세척과 아르곤 플라즈마 처리는 비교적 효과적으로 맞춤형 지대주의 잔류 미세입자를 제거할 수 있는 방법이다.

중심성 기도 폐쇄를 동반한 폐암에서 냉동치료의 임상적 유용성 및 부작용 (Clinical Benefits and Complications of Cryotherapy in Advanced Lung Cancer with Central Airway Obstruction)

  • 정진용;이승룡;김대현;이경주;이은주;강은해;정기환;김제형;신철;심재정;인광호;강경호;유세화
    • Tuberculosis and Respiratory Diseases
    • /
    • 제64권4호
    • /
    • pp.272-277
    • /
    • 2008
  • 연구배경: 중심성 기도폐쇄를 동반하는 진행성 폐암환자에서 기도폐쇄를 호전시키기 위해 다양한 중재적 시술 Tuberculosis and Respiratory Diseases Vol. 64. No. 4, Apr. 2008277방법들이 시도되고 있으며, 이러한 시술방법 중 최근 굴절성 cryoprobe를 이용한 냉동치료가 국내에서도 시도되고 있다. 방법: 냉동치료 기계는 cryomachine과 cryoprobe로 구성되며, 냉매로는 아산화질소(N2O)를 사용하였다. 굴곡경 기관지내시경의 working chanel을 통해 굴절성 cryoprobe를 악성종양의 중심에 위치한 후 급속 냉동($-89^{\circ}C$)하여 악성 종양 조직을 냉동 시킨 후 stalk을 puling하여 제거하거나 급속 냉동과 해동 과정을 반복하였다. 결과: 중심성 기도폐쇄가 발생한 진행성 폐암 환자 4명에게 냉동치료를 시술하였다. 3명의 환자에서 성공적으로 기도폐쇄를 유발하는 종양을 제거하였으며, 그 후 호흡곤란 및 무기폐 소견이 호전되었다. 1명의 환자에서 기관지 천공으로 인한 종격동 기종이 발생하였으며 또 다른 환자에서 냉동치료 도중 대량 출혈이 발생하였으나 응급 조치 후 다시 회복되었다.