• Title/Summary/Keyword: Area-Ratio

Search Result 7,934, Processing Time 0.041 seconds

Effect of Mixed Jet with Primary Nozzle Area Ratio of Ejector on Oxygen Transfer Characteristics (산소 전달 특성에 미치는 이젝터 구동 노즐 면적비에 따른 혼합 분류의 영향)

  • Park, Sang Kyoo;Yang, Hei Cheon
    • Journal of ILASS-Korea
    • /
    • v.27 no.3
    • /
    • pp.126-133
    • /
    • 2022
  • The objective of this is to experimentally investigate the effect of mixed jet on the oxygen transfer characteristics with the primary nozzle area ratio of an annular nozzle ejector for the application of a microbial fuel cell. A direct visualization method with a high speed camera system was used to capture the horizontal mixed jet images, and a binarization technique was used to analyze the images. The clean water unsteady state technique was used for the oxygen transfer measurement. The air-water mixed jet discharging into a water tank behaved similar to a buoyancy or horizontal jet with the primary nozzle area ratio. It was found that an optimum primary nozzle area ratio was observed where the oxygen transfer performance reached its maximum value due to the decrease of air volume fraction and the increase of jet length and air bubble dispersion.

Effect of the Passage Area Ratio of an Impeller on the Performance of Two-Dimensional Centrifugal Compressors (임펠러의 유로 면적비가 2차원 원심압축기의 성능에 미치는 영향)

  • Park, Han-Young;Shin, You-Hwan;Choi, Hang-Cheol;Kim, Kwang-Ho;Chung, Jin-Taek
    • The KSFM Journal of Fluid Machinery
    • /
    • v.11 no.5
    • /
    • pp.22-29
    • /
    • 2008
  • This study is performed to understand the effect of the variation in the passage area of a two-dimensional impeller on its performance characteristics. We observe the results with changing the area ratio of inlet to outlet about $1{\sim}2.8$. A comparison between the experimental and numerical results was performed for the same configuration in order to verify the reliability of the CFD code. Overall characteristics in the passages of impeller were analyzed in detail including streamline, Mach number, pressure and polytropic efficiency distribution. When the passage area ratio exceeds 2, the pressure ratio is high. An area ratio of 2.3 showed the highest efficiency. The results will be used as useful reference data to establish the design concept of two-dimensional impeller and to improve its performance.

A Study on Necktie Image of Striped Pattern according to Area-Ratio Variation of Chromatic and Achromatic Colors (무채색과 유채색의 면적비 변와에 따른 스트라이프 패턴의 넥타이 이미지 연구)

  • Sung, Nam-Suk;Choi, Su-Koung
    • Journal of the Korean Society of Costume
    • /
    • v.59 no.4
    • /
    • pp.67-81
    • /
    • 2009
  • This study aims to characterize the effect of different combinations of chromatic-achromatic colors and 1:2:3 area-ratio variation of stripe necktie, and gender on the image of male wearer. The experimental materials developed for this study are a set of stimuli and response scales. The stimuli consist of 84 color pictures manipulated with every combination of 12 different colors and 7 different area-ratio. The 7-point scale designed for visual evaluation of image formation included 26 bipolar adjectives. The subjects were 2016 undergraduate students in Gyeongnam, Seoul, Busan, and Daegu areas. The results of this study were as follows. The analyses of images of male wearer in terms of combinations of chromatic-achromatic colors and I :2:3 area-ratio variation of oblique stripe necktie reveal that the concerned factors are of five characteristic dimensions of youth-activity, ability, attractiveness, appeal, and warmness. In addition, it has been found that individual images of male wearer are affected by observer's gender as well as combinations of chromatic-achromatic colors and 1:2:3 area-ratio variation of stripe neckties and that those images vary with every combination of each factor. The study results are highly expected to be used as useful sources in developing necktie designs.

A Comparative Study of the Harmony of coloration according to Transformation of Color Area-Ratio in Traditional Korean Dress - On the Tone on Tone coloration - (색상 면적비 변화에 따른 한복배색의 조화감 비교 연구 - 톤 온 톤 배색을 중심으로 -)

  • Kang Kyung-Ja;Chu Mi-Seon;Paeng Suk-Kyung
    • Journal of the Korean Home Economics Association
    • /
    • v.43 no.5 s.207
    • /
    • pp.107-115
    • /
    • 2005
  • The purpose of this research was to compare the harmony of tone on tone coloration according to transformation of color area-ratio in traditional Korean dress. The respondents were asked to evaluate 36 stimuli of the traditional Korean skirt and jacket with different color tone. The subjects were 83 female undergraduate students. The results are as follows. For red colors, combinations of vivid/dull, vivid/dark, and light/dark made a difference in the harmony of coloration according to the transformation of color area-ratio. For yellow colors, combinations of vivid/dark, light/dull, and light/dark made a difference in the harmony of coloration according to the transformation of color area-ratio. For green colors, combinations of vivid/dull, vivid/dark, light/dull, and light/dark made a difference in the harmony of coloration according to the transformation of color area-ratio.

Effect of performance method of sand compaction piles on the mechanical behavior of reinforced soft clay

  • Kwon, Jeonggeun;Kim, Changyoung;Im, Jong-Chul;Yoo, Jae-won
    • Geomechanics and Engineering
    • /
    • v.14 no.2
    • /
    • pp.175-185
    • /
    • 2018
  • Sand Compaction Piles (SCPs) are constructed by feeding and compacting sand into soft clay ground. Sand piles have been installed with irregular cross-sectional shapes, and mixtures of both sand and clay, which violate the design requirement of circular shape according to the replacement area ratio due to various factors, including side flow pressure. Therefore, design assumptions cannot be satisfied according to the conditions of the ground and construction and the replacement area ratio. Two case histories were collected, examined, and interpreted in order to study the effect of the shape of SCPs. The effects of the distortion of SCP shape and the mixture of sand and clay were studied with the results of large direct shear tests. The design internal friction angle was secured with the irregular cross-sectional sand piles regardless of the replacement area ratio. The design internal friction angle was secured regardless of mixed condition when the mixture of sand and clay was higher than the replacement area ratio of 65%. Therefore, systematic construction management is recommended with a replacement area ratio below 65%.

A Study on the Change of Area and Space Organization Ratio of General Hospital Wards in Busan and Gyeongnam (부산 경남 지역의 주요 종합병원 병동부 면적 및 공간 구성 비율의 변화에 관한 연구)

  • Park, Byeongjun;Lee, Jangmin
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.18 no.4
    • /
    • pp.7-16
    • /
    • 2012
  • Purpose : The purpose of this study is to look into the change of area and space organization percentage of wards in main general hospitals in Busan and Gyeongnam. Method : Patient area, nursing area, service area, training area, common area were classified for functional space organization. Patient area was reclassified to bedroom and comfort area, and common area was reclassified into vertical circulation, horizontal circulation and facility area. Also, method of area calculation was chosen standard to wall center-lines following building act 911 and functional space area of each hospital was estimated and comparatively analyzed. Result : For hospitals completed before 2000, area ratio by functional space for patient area, nursing area, service area and common area showed 53.6%, 10.2%, 0.8%, and 35.3% respectively. For hospitals completed after 2000, area ratio by functional space for patient area, nursing area, service space, and common area showed 49.2%, 12.6%, 1.1%, and 37.2% respectively. Implications : Through this study, change of percentage of space organization of main general hospitals in Busan Gyeongnam can be understood. Also because most studies on area organization of general hospital wards were focused on the capital area, this study provides basic material for future studies related to area of general hospital wards in Busan Gyeongnam.

Mechanism of Soil Remediation in Contaminated Area Using Vertical Drains (연직배수재(VDs)에 의한 오염지반정화 메커니즘 연구)

  • Lee Haeng Woo;Chang Pyoung Wuck;Kang Byung Yoon;Kim Hyun Tae
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.47 no.5
    • /
    • pp.63-71
    • /
    • 2005
  • In-situ soil remediation mechanism through the vertical drains (VDs) is analyzed with numerical model as the error and complementary error function. Results from in-situ test and analysis indicate that the contaminant concentration ratio as initial one ( C/$C_0$) increases as the radius ratio ( r/R) increases from the injection well, and also increases as the depth ratio ( z/ H) increases from the top of contaminated area. The elapse time needed to attain $50\%$ and $90\%$ clean up level ($ t_{50},\;t_{90}$) increases as the radius ratio ( r/R) and the depth ratio ( z/ H) increase. As above results, the procedure of soil flushing in contaminated area using vertical drains makes progress from the top of injection well to the bottom of extraction well.

ANALYSIS OF RELATIONSHIP BETWEEN IMAGE COMPRESSION AND GAMUT VARIATION

  • Park, Tae-Yong;Ko, Kyung-Woo;Ha, Yeong-Ho
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2009.01a
    • /
    • pp.80-84
    • /
    • 2009
  • This paper investigates the relationship between the compression ratio and the gamut area for a reconstructed image when using JPEG and JPEG2000. Eighteen color samples from the Macbeth ColorChecker are initially used to analyze the relationship between the compression ratio and the color bleeding phenomenon, i.e. the hue and chroma shifts in the a*b* color plane. In addition, twelve natural color images, divided into two groups depending on four color attributes, are also used to investigate the relationship between the compression ratio and the variation in the gamut area. For each image group, the gamut area for the reconstructed image shows an overall tendency to increase when increasing the compression ratio, similar to the experimental results with the Macbeth ColorChecker samples. However, with a high compression ratio, the gamut area decreases due to the mixture of adjacent colors, resulting in more grey.

  • PDF

Computational Analysis of the Flowfield of a Mixer-Ejector Nozzle (Mixer-Ejector 노즐 유동장에 관한 수치해석)

  • Park, Yun-Ho
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.6 no.1
    • /
    • pp.71-82
    • /
    • 2002
  • A time-iterative compressible Navier-Stokes code is developed to analyze the flowfield of a two-dimensional ejector nozzle system. A parametric study has been made for two controlling parameters, duct to nozzle area ratio and nozzle pressure ratio. Results show that there is an optimum area ratio for an efficient pumping of secondary flow. At high area ratios, a freestream flow directly passes through the mixing duct without giving adequate pumping. While at low area ratios, jet boundary is acting as a blockage to incoming flow. The nozzle pressure ratio variation shows that the pumping rate increases as the pressure ratio increases provided there is no interaction between the shroud wall and the shock cell structure.

Remote Sensing Application for the Mineralized Zone Using Landsat TM Data (LANSAT TM자료에 의한 광화대조사 응용기법개발)

  • 姜必鍾;智光薰;曺民肇;崔映燮;Choi, Young Sup
    • Korean Journal of Remote Sensing
    • /
    • v.2 no.2
    • /
    • pp.79-94
    • /
    • 1986
  • TM data, which have better resolution in spatial and spectral than MSS data, were used for this study, and several Image Processing Techniques (IPT) were examined for finding the best IPT to fit to lineament extraction and mineralized zone mapping. The Ryeongnam area was selected as test area, because the area is one of major mineralized zones in Korea and its hydrothermal alteration zone is wider and deeper than other areas. The spatial filtering method is most optimum one for limeament extraction: that is, the directional spatial filtering is most efficient to detect N-S, E-W direction lineaments on the image, and the high boost filtering can be applied for mapping all direction lineaments. The ratio method was selected for detecting altered zone. It is possible to make several tens combinations in ratio with 7 bands of TM data, but considering spectral characteristics of each band of TM to the geological meterials and vegetation, the band 4/band 3(A), band 5/band 7(B), and B/A ratio methods were chosen among them. The 5/7 ratio image did not show clearly the altered area due to noise from vegetation cover, so the 4/3 ratio imae was used for trying to decrease the effect of vegetation. As a result the B/A ratio image showed quite nicely the altered zone of the test area. In conclusion, the spatial filtering is the best image processing techniques for lineament mapping, and the B/A ratio image in TM data is useful for the mineralized zone mapping.