• Title/Summary/Keyword: Area measurement

Search Result 3,996, Processing Time 0.027 seconds

433 MHz Radio Frequency and 2G based Smart Irrigation Monitoring System (433 MHz 무선주파수와 2G 통신 기반의 스마트 관개 모니터링 시스템)

  • Manongi, Frank Andrew;Ahn, Sung-Hoon
    • Journal of Appropriate Technology
    • /
    • v.6 no.2
    • /
    • pp.136-145
    • /
    • 2020
  • Agriculture is the backbone of the economy of most developing countries. In these countries, agriculture or farming is mostly done manually with little integration of machinery, intelligent systems and data monitoring. Irrigation is an essential process that directly influences crop production. The fluctuating amount of rainfall per year has led to the adoption of irrigation systems in most farms. The absence of smart sensors, monitoring methods and control, has led to low harvests and draining water sources. In this research paper, we introduce a 433 MHz Radio Frequency and 2G based Smart Irrigation Meter System and a water prepayment system for rural areas of Tanzania with no reliable internet coverage. Specifically, Ngurudoto area in Arusha region where it will be used as a case study for data collection. The proposed system is hybrid, comprising of both weather data (evapotranspiration) and soil moisture data. The architecture of the system has on-site weather measurement controllers, soil moisture sensors buried on the ground, water flow sensors, a solenoid valve, and a prepayment system. To achieve high precision in linear and nonlinear regression and to improve classification and prediction, this work cascades a Dynamic Regression Algorithm and Naïve Bayes algorithm.

Comparison of Outlines by Image Analysis for Derivation of Objective Validation Results: "Ito Hirobumi's Characters on the Foundation Stone" of the Main Building of Bank of Korea (이미지 분석법을 활용한 형상정보의 비교와 객관적 검증결과의 도출사례: 한국은행 본관 정초석 '이토 히로부미 글씨'의 검증)

  • Yoo, Woo Sik
    • Journal of Conservation Science
    • /
    • v.36 no.6
    • /
    • pp.511-518
    • /
    • 2020
  • There have been reports that the "jeongcho (定礎)" letters of the foundation stone at the historical site No. 280 of the "Main Building of the Bank of Korea in Seoul" were written by Prince Ito Hirobumi (伊藤博文), the first Resident-General of Japan in Korea. An on-site investigation by an advisory group consisting of three experts in calligraphy; revealed that the two characters of '定礎' inscribed on the foundation stone are the characteristics of Ito Hirobumi's handwriting, judging from the writing style and habits observed in the collections of the Central Library of Hamamatsu City, Japan. It was reported that his writing was confirmed by the experts, but no basis was provided. To provide more objective and quantitative supporting data, rather than qualitative judgment based on feeling, it is necessary to present the basis for judgment through quantitative image comparison results through image analysis. In this paper, using image analysis software, Ito Hirobumi's calligraphy writing and the inscribed characters of the foundation stone were compared and analyzed to confirm the contents of the press release. The character comparison process and character area measurement results are a good example showing that if objective judgment basis data are needed in a similar situation, an objective judgment basis can be prepared through quantification using image analysis.

Estimation of channel morphology using RGB orthomosaic images from drone - focusing on the Naesung stream - (드론 RGB 정사영상 기반 하도 지형 공간 추정 방법 - 내성천 중심으로 -)

  • Woo-Chul, KANG;Kyng-Su, LEE;Eun-Kyung, JANG
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.25 no.4
    • /
    • pp.136-150
    • /
    • 2022
  • In this study, a comparative review was conducted on how to use RGB images to obtain river topographic information, which is one of the most essential data for eco-friendly river management and flood level analysis. In terms of the topographic information of river zone, to obtain the topographic information of flow section is one of the difficult topic, therefore, this study focused on estimating the river topographic information of flow section through RGB images. For this study, the river topography surveying was directly conducted using ADCP and RTK-GPS, and at the same time, and orthomosiac image were created using high-resolution images obtained by drone photography. And then, the existing developed regression equations were applied to the result of channel topography surveying by ADCP and the band values of the RGB images, and the channel bathymetry in the study area was estimated using the regression equation that showed the best predictability. In addition, CCHE2D flow modeling was simulated to perform comparative verification of the topographical informations. The modeling result with the image-based topographical information provided better water depth and current velocity simulation results, when it compared to the directly measured topographical information for which measurement of the sub-section was not performed. It is concluded that river topographic information could be obtained from RGB images, and if additional research was conducted, it could be used as a method of obtaining efficient river topographic information for river management.

Deep Learning Applied Method for Acquisition of Digital Position Signal of PET Detector (PET 검출기의 디지털 위치 신호 측정을 위한 딥러닝 적용 방법)

  • Byungdu, Jo;Seung-Jae, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.6
    • /
    • pp.697-702
    • /
    • 2022
  • For imaging in positron emission tomography(PET), it is necessary to measure the position of the scintillation pixel interacting with the gamma rays incident on the detector. To this end, in the conventional system, a flood image of the scintillation pixel is obtained, the imaged area of each scintillation pixel is separated, and the position of the scintillation pixel is specified and acquired as a digital signal. In this study, a deep learning method was applied based on the signal formed by the photosensor of the detector, and a method was developed to directly acquire a digital signal without going through various procedures. DETECT2000 simulation was performed to verify this and evaluate the accuracy of position measurement. A detector was constructed using a 6 × 6 scintillation pixel array and a 4 × 4 photosensor, and a gamma ray event was generated at the center of the scintillation pixel and summed into four channels of signals through the Anger equation. After training the deep learning model using the acquired signal, the positions of gamma-ray events that occurred in different depth directions of the scintillation pixel were measured. The results showed accurate results at every scintillation pixel and position. When the method developed in this study is applied to the PET detector, it will be possible to measure the position of the scintillation pixel with a digital signal more conveniently.

A Study of Cancer Incidence Rate due to Photoneutron Dose during Radiation Therapy for Prostate Cancer Patients (전립샘암 환자의 방사선 치료 시 광중성자 선량으로 인한 암 발생률의 연구)

  • Lee, Joo-Ah
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.4
    • /
    • pp.471-476
    • /
    • 2022
  • The purpose of this study was to study the probability of cancer occurrence due to photoneutron dose exposure of the colon and thyroid gland, which are normal organs, in 3D CRT, IMRT 5 portals, and IMRT 9 portals, which are radiotherapy methods for prostate cancer. The total prescribed dose for prostate cancer was 6600 cGy, 220 cGy per dose, and 30 divided irradiations were applied for the total number of times. After setting up the Rando phantom on the treatment table (couch) of the medical linear accelerator used in the experiment, an optically stimulated luminescence albedo neutron dosimeter was placed on the corresponding area of the large intestine and thyroid gland of the phantom for measurement. During 3D CRT of prostate cancer, the probability of secondary cancer due to photoneutron dose to the colon and thyroid gland, which are normal organs, was 1.8 per 10,000 people. And IMRT 5 portals were 8.7 per 10,000 people, which was about 5 times larger than 3D CRT. IMRT 9 portals derived the result that there is a probability that 1.2 people per 1,000 people will develop cancer. Based on this study, the risk of secondary radiation exposure due to the dose of photoneutrons generated during radiation therapy is studied, and it is thought that it will be used as useful data for radiation protection in relation to the stochastic effect of radiation in the future.

Effect of tension difference of kinesio tape applied to the tibialis anterior muscle on muscle strength, joint range of motion, and balance of the ankle joint in young college students (키네시오 테이프의 장력 차이가 젊은 대학생들의 발목 근력, 관절가동범위 및 균형에 미치는 영향)

  • Lee, Dae Hoon;Kim, Cho In;Shin, Gi Ha;Yeom, Yoo Jin;Kim, Ji Sung;Kim, Seong Ho
    • Journal of Korean Physical Therapy Science
    • /
    • v.29 no.2
    • /
    • pp.28-37
    • /
    • 2022
  • Background: The purpose of this study was to investigate the effects of differences in the tension of Kinesio tape applied to the tibialis anterior muscle on muscle strength, joint range of motion and balance of ankle joint in young adults. Design: Randomized Controlled Trial. Methods: 41 young college students participated in this study. And the subjects were allocated randomly to two group. The experimental group had a tension difference (10%G, n=20). And there was no difference in tension in the control group (0%G, n=21). Jtech power track II, goniometer, and Biorescue were used to measure muscle strength, joint range of motion and balance. The paired t-test was performed to examine the differences within the groups before and after taping, and the independent t-test was performed to examine the differences between the groups. Result: 1) As a result of measuring muscle strength of each group, all measurements except 0%G of plantar flexion showed insignificant results. 2) Measurement of joint range of motion each group showed that neither 0%G nor 10%G was significant. 3) As a result of measuring the baladncing ability of each group there was a significant decrease in length, and average speed of the balancing capability (p<.05). 4) Comparisons between groups showed significant differences in the area among balance capability (p<.05). Conclusions: Based on these findings, the tension difference of Kinesio tape applied to the tibialis anterior muscle shows little effect on the muscle strength, range of motion, and balance of ankle joints. Given the current lack of research on the tension of kinesio tapes many studies are needed in the future to establish clear theories.

Efficient method for acquirement of geospatial information using drone equipment in stream (드론을 이용한 하천공간정보 획득의 효율적 방안)

  • Lee, Jong-Seok;Kim, Si-Chul
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.2
    • /
    • pp.135-145
    • /
    • 2022
  • This study aims to verify the Drone utilization and the accuracy of the global navigation satellite system (GNSS), Drone RGB (Photogrammetry) (D-RGB), and Drone LiDAR (D-LiDAR) surveying performance in the downstream reaches of the local stream. The results of the measurement of Ground Control Point (GCP) and Check Point (CP) coordinates confirmed the excellence. This study was carried out by comparing GNSS, D-RGB, and D-LiDAR with the values which the hydraulic characteristics calculated using HEC-RAS model. The accuracy of three survey methods was compared in the area of the study which is the ownership station, to 6 GCP and 3 CP were installed. The comparison results showed that the D-LiDAR survey was excellent. The 100-year frequency design flood discharge was applied in the channel sections of the small stream. As a result of D-RGB surveying 2.30 m and D-LiDAR 1.80 m in the average bed elevation, and D-RGB surveying 4.73 m and D-LiDAR 4.25 m in the average flood condition. It is recommended that the performance of D-LiDAR surveying is efficient method and useful as the surveying technique of the geospatial information using the drone equipment in stream channel.

Safety Assessment of the Level of Safety Culture of National Critical Infrastructure Expressway Operating Organizations (국가핵심기반 고속도로 운영기관의 안전문화 수준진단에 관한 소고)

  • Seo, Jeong-soo;Cheung, Chong-soo
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.3
    • /
    • pp.636-645
    • /
    • 2022
  • Purpose: This study intends to suggest alternatives for improving the level of safety culture by measuring/analyzing safety culture targeting employees of national core-based highway operating organizations. Method: Using the 'Safety Awareness Level Diagnosis Tool' of the Korea Occupational Safety and Health Agency, 16 sub-factor measurement tools reflecting 4 safety culture areas and 4 safety culture activities were evaluated for a total of 144 items. were surveyed/analyzed by online questionnaire. Result: As for the results by safety culture area, "safe operation" was the highest, and "safe communication" was the lowest. As for the results of each safety culture activity, "safe execution (D)", which evaluates whether the plan was implemented, was high. The lowest level of safety culture is "Safety Improvement (A)" Conclusion: When establishing a company's safety and health management measures, the most important aspect of management is the level of safety culture. The ultimate goal is to improve the level of safety culture. In this study, it was possible to confirm the safety culture level of the national core-based expressway operating institution. In the future, we intend to conduct a study on how safety culture affects business continuity management system (BCMS).

A study on the selection of evapotranspiration observatory representative location in Chuncheon Dam basin (증발산량 관측 대표위치 선정에 관한 연구: 춘천댐 유역을 중심으로)

  • Park, Jaegon;Kim, Kiyoung;Lee, Yongjun;Hwag-Bo, Jong Gu
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.11
    • /
    • pp.979-989
    • /
    • 2022
  • In hydrological surveys, observation through representative location is essential due to temporal and spatial limitations and constraints. Regarding the use of hydrological data and the accuracy of the data, there are still insufficient observatories to be used in a specific watershed. In addition, since there is virtually no standard for the location of the current evapotranspiration, this study proposes a method for determining the location of the evapotranspiration. To determining the location of evapotranspiration, a grid is selected in consideration of the operating range of the Flux Tower using the eddy covariance measurement method, which is mainly used to measure evapotranspiration. The grid of representative location was calculated using the factors affecting evapotranspiration and satellite data of evapotranspiration. The grid of representative location was classified as good, fair, and poor. As a result, the number of good grids calculated was 54. It is judged that the classification of the grid has been achieved regarding topography and land use as a characteristic that appeared in the classification of the grid. In particular, in the case of elevation or city area, there was a large deviation, and the calculated good grid was judged to be a group between the two distributions.

Impact of lattice versus solid structure of 3D-printed multiroot dental implants using Ti-6Al-4V: a preclinical pilot study

  • Lee, Jungwon;Li, Ling;Song, Hyun-Young;Son, Min-Jung;Lee, Yong-Moo;Koo, Ki-Tae
    • Journal of Periodontal and Implant Science
    • /
    • v.52 no.4
    • /
    • pp.338-350
    • /
    • 2022
  • Purpose: Various studies have investigated 3-dimensional (3D)-printed implants using Ti6Al-4V powder; however, multi-root 3D-printed implants have not been fully investigated. The purpose of this study was to explore the stability of multirooted 3D-printed implants with lattice and solid structures. The secondary outcomes were comparisons between the 2 types of 3D-printed implants in micro-computed tomographic and histological analyses. Methods: Lattice- and solid-type 3D-printed implants for the left and right mandibular third premolars in beagle dogs were fabricated. Four implants in each group were placed immediately following tooth extraction. Implant stability measurement and periapical X-rays were performed every 2 weeks for 12 weeks. Peri-implant bone volume/tissue volume (BV/TV) and bone mineral density (BMD) were measured by micro-computed tomography. Bone-to-implant contact (BIC) and bone area fraction occupancy (BAFO) were measured in histomorphometric analyses. Results: All 4 lattice-type 3D-printed implants survived. Three solid-type 3D-printed implants were removed before the planned sacrifice date due to implant mobility. A slight, gradual increase in implant stability values from implant surgery to 4 weeks after surgery was observed in the lattice-type 3D-printed implants. The marginal bone change of the surviving solid-type 3D-printed implant was approximately 5 mm, whereas the value was approximately 2 mm in the lattice-type 3D-printed implants. BV/TV and BMD in the lattice type 3D-printed implants were similar to those in the surviving solid-type implant. However, BIC and BAFO were lower in the surviving solid-type 3D-printed implant than in the lattice-type 3D-printed implants. Conclusions: Within the limits of this preclinical study, 3D-printed implants of double-rooted teeth showed high primary stability. However, 3D-printed implants with interlocking structures such as lattices might provide high secondary stability and successful osseointegration.