• Title/Summary/Keyword: Area light illumination

Search Result 113, Processing Time 0.026 seconds

Comparison of the Refracting Power and Aberration according to the Measurement Change in Illumination and Area of the Pupils (조도와 동공 영역의 측정 변화에 따른 굴절력과 수차의 비교)

  • Kim, Bong-Hwan;Han, Seon-Hee;Park, Byeong-Gyu;Hwang, Hyeon-Ju;Bae, Ye-Sol;Seo, Jeong-Bin;Yeo, Ye-Eun;Yoon, Min-Jeong;Kim, Hak-Jun
    • Journal of Korean Clinical Health Science
    • /
    • v.4 no.2
    • /
    • pp.550-555
    • /
    • 2016
  • Purpose. We compared with the refracting power and aberration according to the measurement change in illumination and the pupils area by using the auto refraction instruments. Methods. In this study it were examined 64 eyes without eye disease, 21.4 (${\pm}2.54$) age, 32 (male 10, female 22) patients. Experiments in general illumination using the auto refraction instruments (HRK-8000A, Huvitz, Korea) was measured in both eyes 3 times and after scotopic for 30 minutes in a dark room blocked the light was measured in the same way. Aberration were measured coma, spherical aberration, high and low order aberrations in a general illumination (3500 lux) and low illumination (5 lux) of the pupil area 3.96 mm and 5.96 mm. Results. In the general illumination for measuring of the pupil area, the refractive power, coma, spherical aberration and low order aberration was no significant difference. In the low illumination, spherical aberration of the pupil area was $0.005({\pm}0.015){\mu}m$ in a 3.96mm, $0.014({\pm}0.020){\mu}m$ in a 5.96 mm and appeared a significant difference(p = 0.003). In general and low illumination on the results of comparing the measured values of the refractive power and aberration at the pupil area 3.96 mm, high order aberrations was $0.205({\pm}0.145){\mu}m$ in general illumination, $0.132({\pm}0.075){\mu}m$ in low illumination and appeared a significant differences(p = 0.001). High order aberrations at the pupil area 5.96 mm was $0.278({\pm}0.244){\mu}m$ in general illumination, $0.150({\pm}0.092){\mu}m$ in low illumination and appeared a significant differences(p = 0.000). Conclusions. When the eye refractive power measured by the automatic refraction does not depend on the illumination conditions and size of the observation pupil area, it was found that aberrations are affected by the illumination and the observation pupil area. It was found that the eye examination chamber illumination to obtain accurate measurement produces better results to decrease than to increase.

Producing Uniform High Illumination Large Area Backlight Systems with Long Life

  • Guzowski, Lawrence T.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.779-782
    • /
    • 2004
  • Establishing and maintaining optimum lamp operating temperature is critically important in backlight systems for large area displays. The information presented in this paper is based upon work completed for a tiled 37.5" AM LCD, plus projections for a 37.5", 42" & 50" monolithic display. Due to the size of the units, a requirement for highly collimated light and a requirement for high brightness, >550 nits at the display surface, significant wattage is required which generates high heat levels in the backlight display assembly and potentially, at the display rear surface. Uniformity of illumination becomes an important element in the system design because of the large area involved.

  • PDF

Development of Ring Light for Shadowless Shooting for Medical Purpose (의료용 무영 촬영을 위한 링라이트 개발)

  • Cheon, Min-Woo;Cho, Kyung-Jae;Park, Yong-Pil
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.9
    • /
    • pp.708-713
    • /
    • 2010
  • In this research a ring light was developed so that a partial shadowless shooting for the patient's affected area at the medical treatment room and surgical operation room using high luminance light emitting diode (LED) for which attention is being paid as new lighting parts for medical purpose. LED which was applied to the development used high luminance three color LED for full color for which various color materialization and the adjustment of radiation intensity are possible and we can get white light in order to emphasize the delicate expression for generic tone of shooting object, strong highlight, simple shadow and three dimensional effect at the time of close-up shadowless shooting of the affected area. And at the time of design of ring light, the characteristics of LED and the loss of light at the time of penetrating light diffusion PC were considered so that intensity of illumination for over 150 lx can be obtained. The result of measurement of the intensity of illumination of the ring light that was developed revealed that maximum intensity of illumination of 225.7 lx was obtained, while smoke index was measured to be maximum 78 Ra in the case of Red(50%) Green(100%) and Blue LED(60%). We could confirm that response speed was also very fast as 1.72 ms.

Traffic Light Recognition Using a Deep Convolutional Neural Network (심층 합성곱 신경망을 이용한 교통신호등 인식)

  • Kim, Min-Ki
    • Journal of Korea Multimedia Society
    • /
    • v.21 no.11
    • /
    • pp.1244-1253
    • /
    • 2018
  • The color of traffic light is sensitive to various illumination conditions. Especially it loses the hue information when oversaturation happens on the lighting area. This paper proposes a traffic light recognition method robust to these illumination variations. The method consists of two steps of traffic light detection and recognition. It just uses the intensity and saturation in the first step of traffic light detection. It delays the use of hue information until it reaches to the second step of recognizing the signal of traffic light. We utilized a deep learning technique in the second step. We designed a deep convolutional neural network(DCNN) which is composed of three convolutional networks and two fully connected networks. 12 video clips were used to evaluate the performance of the proposed method. Experimental results show the performance of traffic light detection reporting the precision of 93.9%, the recall of 91.6%, and the recognition accuracy of 89.4%. Considering that the maximum distance between the camera and traffic lights is 70m, the results shows that the proposed method is effective.

Effectiveness of Flashing Light for Increasing Photosynthetic Efficiency of Microalgal Cultures over a Critical Cell Density

  • Park, Kyong-Hee;Lee, Choul-Gyun
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.6 no.3
    • /
    • pp.189-193
    • /
    • 2001
  • Critical cell density (CCD), the maximum cell concentration without mutual shading in algal cultures, can be used as a new operating parameter for high-density algal cultures and for the application of the flashing light effect on illuminated algal cultures. CCD is a function of average cell volume and light illumination area. The CCD is thus proposed as an index of estimation of mutual shading in algal cultures. Where cell densities are below the CCD, all the cells in photobioreactors can undergo photosysnthesis at their maximum rate. At cell densities over CCD, mutual shading will occur and some cells in the illumination chamber cannot grow photoautotrophically. When the cell concentration is higher than the CCD, specific oxygen production rates under flashing light were higher than those under continuous light. The CCD was found to be a useful engineering parameter for the application of flashing light, particularly in high-density algal cultures.

  • PDF

Measurement and Analysis of Luminous Environment in Apartments (공동주택의 실내공간별 빛환경 측정 및 조명평면 분석)

  • Lee, Jung-Eun;Choi, An-Seop;Choi, Sung-Youl
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.19-23
    • /
    • 2004
  • Light is an environmental element which is essential for a man to live and do creative activities in residential area. Especially, modern people arc used to live under artificial light interior surroundings for much time. Currently, the average illumination level of the present apartment is improving, but it still does not reach the recommended level because the present apartment's luminous environment is only based on the life behavior which puts its priority to clear vision. Therefore, it is necessary that proper standard illumination must be used for various use and purpose. From this point of view, this paper investigated the essence of light in the residential area and the luminous environment for apartments was measured. This paper finally suggested well-coordinated lighting condition, derived from the measurement and analysis of luminous environment in these cases.

  • PDF

Optical Design of LED module for Street Light Applications

  • Aung, Aye Thida;Yang, Jong-Kyung;Lee, Seung-Min;Lee, Jong-Chan;Park, Dae-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.11
    • /
    • pp.1-8
    • /
    • 2008
  • In this paper, the optical properties of the 54[W] LED module have confirmed by changing the angles of LED modules for street light applications. The angle of LED module changed from the $0[^{\circ}]$ to $60[^{\circ}]$ varying by $20[^{\circ}]$ as horizontal direction ${\ominus}_1$. Morever, the angle of LED module changed from the $0[^{\circ}]$ to $15[^{\circ}]$ varying by $5[^{\circ}]$ as vertical direction ${\ominus}_2$. As a result of simulation, the average illumination was about 17[lux] and the overall illuminance uniformity was 0.29 for a 10.39[m] long and 6[m] wide illuminance area at height of 6[m], which is acceptable for street lighting illumination in the Illuminating Engineering Society(IES) standard.

Design and Analysis of Diffractive Grating Imprinted Light-guide Plate for LCD Illumination

  • Choi, Hwan-Young;Park, Young-Pil
    • Journal of Information Display
    • /
    • v.5 no.1
    • /
    • pp.7-15
    • /
    • 2004
  • A highly simplified backlight unit mainly composed of diffractive grating in sub-micron order imprinted light-guide plate (LGP) is proposed for edge-lit backlight unit. Optical characteristics of the imprinted LGP are examined by RCWA and the performance is verified through Monte Carlo simulation. Results show that the diffraction efficiency, luminous flux and its uniformity over the area are significantly affected by the angle of incident ray. Consequently couples of design considerations are additionally proposed to enhance luminous flux. In terms of peak luminance and out-coupling luminous flux, the experimental results are agreed well with the performance simulation. Finally, compared with optical characteristics of conventional backlight unit, we could conclude that the proposed simplified backlight unit made of diffractive grating imprinted light-guide plate is a good substitute for the conventional backlight unit.

Incident Light Intensity Dependences of Current Voltage Characteristics for Amorphous Silicon pin Solar Cells (비정질실리콘 pin태양전지에서 입사광 세기에 따른 전류 저압특성)

  • Jang, Jin;Park, Min
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.23 no.2
    • /
    • pp.236-242
    • /
    • 1986
  • The dependence of the current-voltage characteristics of hydrogenated amorphous silicon pin solar cells on the illumimination light intensity has been investigated. The open circuit voltage increases linearly with increasing the logarithm of light intensity up to AM 1, and nearly saturates above AM 1, indicating the open circuit voltage approaching the built-in potential of the pin solar cell above AM 1. The short circuit current density increase with light intensity in proportion to I**0.85 before and I**0.97 after light exposure. Since the series resistance devreses and shunt resistance increases with light intensily, the fill factor increases with light illumination. To increase the fill factor at high illumination in large area solar cells, t6he grid pattern on the ITO substrates should be made. Long light exposure on the solar cells gives rise to the increase of bulk resistance and defect states, resulting in the decrease of the fil factor and short circuit current density. The potential drop in the bulk of the a-Si:H pin solar cells at short circuit condition increases with decreasing temperature, and increases after long light exposure.

  • PDF

A Study on the Control Characteristics of Line Scan Light Source for Machine Vision Line Scan Camera (머신 비전 라인 스캔 카메라를 위한 라인 스캔 광원의 제어 특성에 관한 연구)

  • Kim, Tae-Hwa;Lee, Cheon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.34 no.5
    • /
    • pp.371-381
    • /
    • 2021
  • A machine vision inspection system consists of a camera, optics, illumination, and image acquisition system. Especially a scanning system has to be made to measure a large inspection area. Therefore, a machine vision line scan camera needs a line scan light source. A line scan light source should have a high light intensity and a uniform intensity distribution. In this paper, an offset calibration and slope calibration methods are introduced to obtain a uniform light intensity profile. Offset calibration method is to remove the deviation of light intensity among channels through adding intensity difference. Slope calibration is to remove variation of light intensity slope according to the control step among channels through multiplying slope difference. We can obtain an improved light intensity profile through applying offset and slope calibration simultaneously. The proposed method can help to obtain clearer image with a high precision in a machine vision inspection system.