• Title/Summary/Keyword: Area Standard

Search Result 4,570, Processing Time 0.046 seconds

A Small-Area ISDB-T Time Deinterleaver Structure with Buffer Transformation (버퍼 변환을 이용한 저면적 ISDB-T 시간 디인터리버 구조)

  • Kang, Hyeong-Ju
    • Journal of Advanced Navigation Technology
    • /
    • v.15 no.2
    • /
    • pp.227-233
    • /
    • 2011
  • This paper presents a small-area ISDB-T time deinterleaver structure. ISDB-T is an mobile TV standard that is widely used in Japan and many South American countries. One of the strong points of the standard is the long interleaving depth, which enhance the communication performance. However, long interleaving requires many delay buffers, in other words many pointer registers. This paper reduces the number of pointer registers with the deinterleaver equivalent transformation. The experimental results show that the area is reduced with the proposed structure.

The Study of Logistics Process Standardization (물류 프로세스 표준화 연구)

  • Park, Sun Ho;Park, Soo Min
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.7 no.1
    • /
    • pp.173-183
    • /
    • 2011
  • Global logistics including Korea had developed at various fields through the developed IT technology. In addition, in changing into Internet based digital economy times, economic and logistics activities became extending into worldwide over the cross-border. Logistics activity performed by off-line rapidly changed in real environment. But, unfortunately business process modeling about the whole logistics was not happened, even though process modeling had done by transport stages or logistics entities. Therefore, it is difficult to grasp the whole logistics. Additional cost and time was requested due to no association between logistics entities and invisibility. So, this paper has to be process modeling for logistics industry domain. For objective modeling, work area shall be divided and it extracts general work process per each area. And then it defines subprocess of general work process. Cargo tracking in logistics industry domain means to grasp the status and present states at transportation or storage stage. This paper defines business process and data model for electronic processed work area using the UN/CEFACT standard modeling methodology.

Adaptive GTS allocation scheme with applications for real-time Wireless Body Area Sensor Networks

  • Zhang, Xiaoli;Jin, Yongnu;Kwak, Kyung Sup
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.9 no.5
    • /
    • pp.1733-1751
    • /
    • 2015
  • The IEEE 802.15.4 standard not only provides a maximum of seven guaranteed time slots (GTSs) for allocation within a superframe to support time-critical traffic, but also achieves ultralow complexity, cost, and power in low-rate and short-distance wireless personal area networks (WPANs). Real-time wireless body area sensor networks (WBASNs), as a special purpose WPAN, can perfectly use the IEEE 802. 15. 4 standard for its wireless connection. In this paper, we propose an adaptive GTS allocation scheme for real-time WBASN data transmissions with different priorities in consideration of low latency, fairness, and bandwidth utilization. The proposed GTS allocation scheme combines a weight-based priority assignment algorithm with an innovative starvation avoidance scheme. Simulation results show that the proposed method significantly outperforms the existing GTS implementation for the traditional IEEE 802.15.4 in terms of average delay, contention free period bandwidth utilization, and fairness.

The horizontal line detection method using Haar-like features and linear regression in infrared images

  • Park, Byoung Sun;Kim, Jae Hyup
    • Journal of the Korea Society of Computer and Information
    • /
    • v.20 no.12
    • /
    • pp.29-36
    • /
    • 2015
  • In this paper, we propose the horizontal line detection using the Haar-like features and linear regression in infrared images. In the marine environment horizon image is very useful information on a variety of systems. In the proposed method Haar-like features it was noted that the standard deviation be calculated in real time on a static area. Based on the pixel position, calculating the standard deviation of the around area in real time and, if the reaction is to filter out the largest pixel can get the energy map of the area containing the straight horizontal line. In order to select a horizontal line of pixels from the energy map, we applied the linear regression, calculating a linear fit to the transverse horizontal line across the image to select the candidate optimal horizontal. The proposed method was carried out in a horizontal line detecting real infrared image experiment for day and night, it was confirmed the excellent detection results than the legacy methods.

A Study on the Distribution Characteristics of Minimum Temperatures in Korea (우리나라의 최저기온 분석특성에 관한 연구)

  • 설동일;민병언
    • Journal of the Korean Institute of Navigation
    • /
    • v.18 no.4
    • /
    • pp.155-169
    • /
    • 1994
  • The minimum temperatures are important element in the daily human life, the climatic classification, and so on. In this study, the authors aim to make an analysis the distribution characteristics of minimum temperatures of 95 weather stations in Korea by using the Climatological Standard Normals of Korea VolumeI, VolumeII, and the Climatological Standard Normals of North Korea. The important results are as follows 1) The daily, fifthly, and tenthly minimum temperatures show the highest rate of occurrance on 14th of January( Occurrance rate : 56.6% ), 16~20th of January( 37.6% ), and the middle ten days of January( 82.1% ) respectively. 2) In the regional distribution of minimum temperatures in winter, the values of northern part, inland area, and west coastal region are lower than those of southern, coastal, and east coastal regions respectively. And, bigger cities and industrial area( Seoul, Incheon, Daejeon, Daegu, etc. ) have larger values than the its vicinities. 3) When the daily minimum temperature is $0^{\circ}C$ and less, the days of northern part, inland area, and wests coastal region are higher than those of southern, coastal, and east coastal regions respectively.

  • PDF

A Study on Explosive Hazardous Areas in Hydrogen Handling Facility (수소 취급설비의 폭발위험장소에 관한 연구)

  • PYO, DON-YOUNG;LIM, OCK-TAECK
    • Journal of Hydrogen and New Energy
    • /
    • v.30 no.1
    • /
    • pp.29-34
    • /
    • 2019
  • Safety of hydrogen handling facilities is needed as supply of hydrogen cars has been expanded recently. In this study, the adequacy of safety regulations of hydrogen handling facilities and the risk of damage with hydrogen leakage were studied. The range of explosion hazard location of the hydrogen filling plant was investigated using the computational fluid dynamics (CFD) method, Explosive hazardous area is influenced by leakage type, hole size and sectional area. When the conditions of KS standard are applied, range explosive hazardous area is expanded 7.05 m, maximum. It is about 7 times larger than exceptional standard of hydrogen station. Meanwhile, distance from leakage point to 25% LEL of hydrogen is investigated 1.6 m. Considering the shape of charging hose, regulation of hydrogen station is appropriate.

Test Results of Wide-Area Differential Global Positioning System with Combined Use of Precise Positioning Service and Standard Positioning Service Receiver

  • Kim, Kap Jin;Ahn, Jae Min
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.10 no.1
    • /
    • pp.43-48
    • /
    • 2021
  • Most existing studies on the wide-area differential global positioning system (WADGPS) used standard positioning service (SPS) receivers in their observation reference stations which provide the central control station global positioning system (GPS) measurements to generate augmentation data. In the present study, it is considered to apply a precise positioning service (PPS) receiver to an observation reference station which is located in the threatened jamming area. Therefore, the reference station network consists of a PPS receiver based observation reference station and SPS receiver based observation reference stations. In this case, to maintain correction performance P1C1 differential code bias (DCB) should be compensated. In this paper, P1C1 DCB estimation algorithm was applied to the PPS/WADGPS system and performance test results using measurements in the Korean Peninsula were presented.

Determination of Interception Flow by Pollution Load Budget Analysis in Combined Sewer Watershed (II) - Establishment of Intercepting Capacity and Reduction Goal of Overflow Pollution Load - (오염부하 물질수지 분석을 통한 합류식 하수관거 적정 차집용량 결정(II) - 차집용량과 월류오염부하 삭감목표 설정 -)

  • Lee, Doojin;Shin, EungBai
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.5
    • /
    • pp.557-564
    • /
    • 2005
  • The objective of this study is to evaluate a criteria of intercepting capacity and a reduction goal of overflow pollution load in combined sewer system. In the current criteria of intercepting capacity in the domestic sewage facility standard, it is known that three times of peak sewage (Q) in dry period or runoff flow by 2mm/hr is not appropriate since the intercepted flow is estimated by runoff and show different result even in the same watershed. Though a reduction goal of overflow pollution load can be determined from 1) same level of storm-water runoff pollution load in separated storm sewer, 2) less than 5% sewage load in dry weather period, by the domestic sewage facility standard, the simulated results from storm-water model show large differences between two criteria. While it is predicted that sewage pollution load standard three time larger than separated storm sewer standard in high population density and urbanized area, it is shown that separate storm sewer standard larger than sewage pollution load standard in middle population density and developing area. Accordingly, it is proposed that more reasonable intercepting flow and reduction goal of overflows pollution load should be established to minimize discharging pollution load in combined sewer systems. For the purpose, a resonable standard has to be amended by pollution load balance considering the characteristics of a watershed for generation, collection, treatment, and discharging flow.

A Case Study on the District Standard Planning Applied to Single-Detached House Area of Eomsa District Dooma-Myun Nonsan in Chungnam Province (충남 논산 두마면 엄사지구 단독주택지에 적용된 지구단위계획실태조사연구)

  • Kim, Joon-Yeoul;Choi, Hyo-Seung
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.3 no.3
    • /
    • pp.47-55
    • /
    • 2001
  • For several years by discussion and research, the designing plan and detail plans of year 2000 has been unified. By this result the District Standard Planning as well as the following existing town to control all sorts of living surrounding problems and to make a delightful arranged town are the purpose, which is carrying out all over the country. It is true that the expectation was high to the District Standard Planning. Because of this plan it could use and control the District special quality. Such as, it could rise the ability of beautiful sight and make a advisable town. But in this study the first preceding subject is a problem by the constructing work that the restriction and the standard application has been strong. So the District Standard Planning had many problems. And also by the problems here, as a immoderate volition and stiffen about the operation, the system and equipment lack about the environment improving work, problems with areas by the exciting plannings, the attitude of the executive agency that can't accept the inhabitants will. From these backgrounds we thought the research has not to be standardize in only newtown concept, but has to breath with the exciting towns and the rural areas that the District Planning has been applied. And to revive the special quality of the area and local government by a positive and logical research. Consequently in this study, we researched about the problems of architectures that had issues with the District Standard Planning of architectural part of operation guide which has been assisted form Single-Detached House in Eomsa District Dooma-Myun Nonsan which is located in Chungnam province.

  • PDF

Relationship between Formants and Constriction Areas of Vocal Tract in 9 Korean Standard Vowels (우리말 모음의 발음시 음형대와 조음위치의 관계에 대한 연구)

  • 서경식;김재영;김영기
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.5 no.1
    • /
    • pp.44-58
    • /
    • 1994
  • The formants of the 9 Korean standard vowels(which used by the average people of Seoul, central-area of the Korean peninsula) were measured by analysis with the linear predictive coding(LPC) and fast Fourier transform(FFT). The author already had reported the constriction area for the Korean standard vowels, and with the existing data, the distance from glottis to the constriction area in the vocal tract of each vowel was newly measured with videovelopharyngograms and lateral Rontgenograms of the vocal tract. We correlated the formant frequencies with the distance from glottis to the constriction area of the vocal tract. Also we tried to correlate the formant frequencies with the position of tongue in the vocal tract which is divided into 2 categories : The position of tongue in oral cavity by the distance from imaginary palatal line to the highest point of tongue and the position in pharyngeal cavity by the distance from back of tongue to posterior pharyngeal wall. This study was performed with 10 adults(male : 5, female : 5) who spoke primary 9 Korean standard vowels. We had already reported that the Korean vowel [i], [e], $[{\varepsilon}]$ were articulated at hard palate level, [$\dot{+}$], [u] were at soft palate level, [$\wedge$] was at upper pharynx level and the [$\wedge$], [$\partial$], [a] in a previous article. Also we had noted that the significance of pharyngeal cavity in vowel articulation. From this study we have concluded that ; 1) The F$_1$ is related with the oral cavity articulated vowel [i, e, $\varepsilon$, $\dot{+}$, u]. 2) Within the oral cavity articulated vowel [i, e, $\varepsilon$, $\dot{+}$, u] and the upper pharynx articulated vowel [o], the F$_2$ is elevated when the diatance from glottis to the constriction area is longer. But within the lower pharynx articulated vowel [$\partial$, $\wedge$, a], the F$_2$ is elevated when the distance from glottis to the constriction area is shorter. 3) With the stronger tendency of back-vowel, the higher the elevation of the F$_1$ and F$_2$ frequencies. 4) The F$_3$ and F$_4$ showed no correaltion with the constriction area nor the position of tongue in the vocal tract 5) The parameter F$_2$- F$_1$, which is the difference between F$_2$ frequency and F$_1$ frequency showed an excellent indicator of differenciating the oral cavity articulated vowels from pharyngeal cavity articulated vowels. If the F$_2$-F$_1$ is less than about 600Hz which indicates the vowel is articulated in the pharyngeal cavity, and more than about 600Hz, which indicates that the vowel is articulated in the oral cavity.

  • PDF