• Title/Summary/Keyword: Area Measurement

Search Result 3,982, Processing Time 0.035 seconds

Study of Determination in Measurement System for Safely Managing Debris-Flow (안전한 토석류 관리를 위한 계측기 선정에 관한 연구)

  • Min, Dae-Hong;Yoon, Hyung-Koo
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.3
    • /
    • pp.41-47
    • /
    • 2017
  • Recent studies have shown that there are various systems which can be used to monitor hazardous area in a debris flow location, but lack of methodological research on the exact location where each instrument should be installed has hindered the success of this systems. The objective of this study is to suggest the measurement system for monitoring debris-flow and propose the effective method to determine location of measurement system. Previously studied, from 1991 to 2015, were referred and the applied ratio of every instrument was investigated. The measurement information was divided into 8 categories including rainfall, debris-flow velocity, displacement, fluid pore pressure, ground vibration, image processing, impact force and peak flow depth. The result of this study revealed that the most applied instruments to be rain gauge and geophone for measuring average rainfall and ground vibration respectively. The Analytic Hierarchical Process (AHP) method was selected to determine installation location of instrument and the weighting factors were estimated through fine content, soil thickness, porosity, shear strength, elastic modulus, hydraulic conductivity and saturation. The soil thickness shows highest weights and the fine content relatively demonstrates lowest weights. The score of each position can be calculated through the weighting factors and the lowest score position can be judged as the weak point. The weak point denotes the easily affecting area and thus, the point is suitable for installing the measurement system. This study suggests a better method for safely managing the debris-flow through a precise location for installing measurement system.

A Study on the Geotechnical Property caused by Contact Volume between Weathered Soils and Moisture Sensor for Application of Field Monitoring (현장 모니터링 적용을 위한 풍화토와 함수비센서의 접촉체적에 따른 지반물성 연구)

  • Kim, Man-Il;Chae, Byung-Gon
    • The Journal of Engineering Geology
    • /
    • v.18 no.3
    • /
    • pp.311-319
    • /
    • 2008
  • Evaluation of an amplitude domain reflectometry (ADR) type soil moisture sensor as ThetaProbe ML2x using the response of frequency impedance was performed in a variety of soil porous media such as Jumunjin standard sand, weathered granite soil at Sangju area, and weathered gneiss soil at Jangsu area. The tested soils were classified with a dried condition and a wetted condition for comparing with soil volumetric water content under different installed depths of the measurement sensor. In the results the part of measurement rod including one signal rod and three shield rod 6cm in length was found to decrease the variation of measurement output voltage with insert 5cm over into the soil porous media. The measurement output voltage was verified to more stable output voltage under weathered granite soils and weathered gneiss soils contained the fine grain materials such as clay and silt minerals than the gradual grain material like as the standard sands. Therefore, measurement values by soil moisture sensor can be offered the more stable values when an contact volume between soil porous media and measurement sensor increase.

DETERMINATION OF LONGISSIMUS MUSCLE AREA IN PIG WITH ULTRASONIC LINEAR ELECTRONIC SCANNER

  • Irie, M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.5 no.2
    • /
    • pp.229-235
    • /
    • 1992
  • The usefulness of a portable linear electronic scanner. B-mode ultrasonic machine, was evaluated for estimating the longissimus muscle area from ultrasonic measurement of the muscle depth in 22 live pigs. The electronic scanner was easy to operate for muscle measurements in live pigs, which did not have to be held but were caged. The cross-sectional images of longissimus muscle and covering muscles and fat appeared on the monitor with grey scale in real time. It was easy to identify the ultrasonograms of fat and muscular tissues because the images differed in the degree of the grey scale. The longissimus muscle had less echogenic image than the other muscles. The boundary lines between first, second or third layers of backfat and the longissimus muscle were distinct on the ultrasonogram. The ultrasonic measurement at the shoulder was not acceptable because of the unstable measurements and the complex tissue structure. The repeatabilities for the measurements of longissimus muscle depth at one-half body length and last rib were acceptable. The simple correlation coefficients between ultrasonic estimates of the muscle depth in live pigs and the actual areas in the carcass, were 0.50 and 0.55 at the last rib and the one-half body length, respectively. Therefore, those positions were similarly suitable to measure. The method of electronic scanner for determining longissimus muscle area from the muscle depth was suitable for practical use in the field because of the simple and inexpensive technique.

A Study on the Co-flow Diffusion Flame Temperature Measurement at Various Fuel Flows Rate Using the Rapid Insertion Technique (급속삽입법을 이용한 연료 유량에 따른 동축류 확산화염에서의 온도 측정에 관한 연구)

  • Han Yongtaek;Lee Kihyung
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.1
    • /
    • pp.51-59
    • /
    • 2005
  • Co-flow laminar diffusion flames' temperature has been studied experimentally for ethylene$(C_2H_4)$ using a co-flow burner in order to investigate the characteristics of diffusion flame's temperature distribution. The temperature distributions in the flame were measured by rapid insertion of a R-type thermocouple. The measurement area was divided into three zones. 1st area was expect to created PAH zone, Il nd area was expect to form soot zone, which is known to generate most soot volume fraction, and III rd area was expect to from soot oxidization zone. Also The temperature along the flame y-axis as a fuel quantity was measured. As a results, we have measured temperature neglecting the effect of soot particles attached to the thermocouple junction, which is close to the nozzle and upstream zone has a unstable flow in co-flow diffusion flame and acquires that the flame y-axis temperature has a uniform temperature in the generated soot volume fraction zone(II nd).

Field measurement of local ice pressures on the ARAON in the Beaufort Sea

  • Lee, Tak-Kee;Lee, Jong-Hyun;Kim, Heungsub;Rim, Chae Whan
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.6 no.4
    • /
    • pp.788-799
    • /
    • 2014
  • This study conducted four field measurements of local ice pressure during the icebreaking voyage of the icebreaking research vessel "ARAON" in the Chukchi and Beaufort seas from July to August of 2010. For measurements, 14 strain gauges, including 8 strain gauge rosettes, were set on the bow of the port side. Influence coefficients were determined using a finite element model of the instrumented area and they were used to convert the measured strains on the hull structure to local ice pressures. The converted maximum pressure was calculated as 2.12 MPa on an area of $0.28m^2$. Pressure-area curves were developed from the surveyed pressure data and the results were compared with previously measured data. The study results are expected to provide an understanding of local ice pressures and thus be useful in the structural design of ice class ships.

Acquisition of an Environmental Map by Sonar Data for an Autonomous Mobile Robot with Web Interface

  • Numakura, Hiroshi;Okatani, Shimizu;Maekawa, Hitoshi
    • Proceedings of the IEEK Conference
    • /
    • 2002.07c
    • /
    • pp.1499-1502
    • /
    • 2002
  • A method for acquiring an environmental map by integrating distance data obtained by sonars of a moving robot with web interface is proposed. Sonar data contains outliers in some cases such as ultrasonic beam is projected onto a corner of an object. Therefore, the influence of the outliers should be reduced by detecting outliers. In our method, the outliers are detected by two ways: (i) a method considering geometrical .elation among the observed surface and the projected ultrasonic beau, and (ii) a method considering consistency with data obtained by other sonars. By measurement by the sonar, the distance from the sonar to the obstacle is obtained. Assuming the two dimensional space we can know that the inside of the sector, whose renter coincide with the sonar and whose radius is equal to the obtained distance, is the free area, and a part of the arc of this sector is the obstacle area. The generation of the environmental map is done by integrating the free area and the obstacle area obtained by each measurement by the sonars. Before the integration, the outliers detection is done by two ways mentioned above. Experimental results show that obtained maps obtained by our methods with outliers defection are much better than those by a method without outliers detection.

  • PDF

Determination of Age in Humans from Root Dentin Transparency (치근부 상아질 투명층의 증령적 변화에 관한 연구)

  • 석대현;김종열
    • Journal of Oral Medicine and Pain
    • /
    • v.7 no.1
    • /
    • pp.59-65
    • /
    • 1982
  • For the purpose of estimation of age based on changes in the human root dentin transparency, 173 extracted teeth in each part of upper & lower Lt. & Rt. central, lateral incisors to Lt. & Rt. 2nd premolars were evaluated and analized in terms of root dentin transparency. The results are as follows : 1. It was reconfirmed that there exisits coparatively close correlatonship between age and the root dentin transparency. 2. It was proved that the correlation between the changes in the length and the area of the root dentin transparecy in accordance with the ages of each tooth was highest at the upper central incisor, and next at the low central incisor and the upper second premoloar respectively. 3. In the analysis of the age of the transparency, the error was less in the measurement of the area than in the measurement of the length in regard to the estimation of age. 4. The results from the test of the upper central incisor were boiled down to the following linear equation about the correlation among the area and the length of the transparency, and the age: Y=6.94X+14.7(r=0.59) (Y:estimated age, X:length mm) Y=138.47X+12.31(r=0.72) (Y:estimeted age, $X:area\textrm{cm}^2$)

  • PDF

Comparison of the Refracting Power and Aberration according to the Measurement Change in Illumination and Area of the Pupils (조도와 동공 영역의 측정 변화에 따른 굴절력과 수차의 비교)

  • Kim, Bong-Hwan;Han, Seon-Hee;Park, Byeong-Gyu;Hwang, Hyeon-Ju;Bae, Ye-Sol;Seo, Jeong-Bin;Yeo, Ye-Eun;Yoon, Min-Jeong;Kim, Hak-Jun
    • Journal of Korean Clinical Health Science
    • /
    • v.4 no.2
    • /
    • pp.550-555
    • /
    • 2016
  • Purpose. We compared with the refracting power and aberration according to the measurement change in illumination and the pupils area by using the auto refraction instruments. Methods. In this study it were examined 64 eyes without eye disease, 21.4 (${\pm}2.54$) age, 32 (male 10, female 22) patients. Experiments in general illumination using the auto refraction instruments (HRK-8000A, Huvitz, Korea) was measured in both eyes 3 times and after scotopic for 30 minutes in a dark room blocked the light was measured in the same way. Aberration were measured coma, spherical aberration, high and low order aberrations in a general illumination (3500 lux) and low illumination (5 lux) of the pupil area 3.96 mm and 5.96 mm. Results. In the general illumination for measuring of the pupil area, the refractive power, coma, spherical aberration and low order aberration was no significant difference. In the low illumination, spherical aberration of the pupil area was $0.005({\pm}0.015){\mu}m$ in a 3.96mm, $0.014({\pm}0.020){\mu}m$ in a 5.96 mm and appeared a significant difference(p = 0.003). In general and low illumination on the results of comparing the measured values of the refractive power and aberration at the pupil area 3.96 mm, high order aberrations was $0.205({\pm}0.145){\mu}m$ in general illumination, $0.132({\pm}0.075){\mu}m$ in low illumination and appeared a significant differences(p = 0.001). High order aberrations at the pupil area 5.96 mm was $0.278({\pm}0.244){\mu}m$ in general illumination, $0.150({\pm}0.092){\mu}m$ in low illumination and appeared a significant differences(p = 0.000). Conclusions. When the eye refractive power measured by the automatic refraction does not depend on the illumination conditions and size of the observation pupil area, it was found that aberrations are affected by the illumination and the observation pupil area. It was found that the eye examination chamber illumination to obtain accurate measurement produces better results to decrease than to increase.