• Title/Summary/Keyword: Area Detection

Search Result 3,305, Processing Time 0.031 seconds

Application of Hydroacoustic System and Kompsat-2 Image to Estimate Distribution of Seagrass Beds (수중음향과 Kompsat-2 위성영상을 이용한 해초지 분포 추정)

  • Kim, Keunyong;Eom, Jinah;Choi, Jong-Kuk;Ryu, Joo-Hyung;Kim, Kwang Yong
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.17 no.3
    • /
    • pp.181-188
    • /
    • 2012
  • Despite the ecological importance of seagrass beds, their distributional information in Korean coastal waters is insufficient. Therefore, we used hydroacoustic system to collect accurate bathymetry and classification of seagrass, and Kompsat-2 (4 m spatial resolution) image for detection of seagrass beds at Deukryang Bay, Korea. The accuracy of Kompsat-2 image classification was evaluated using hydracoustic survey result using error matrix and Kappa value. The total area of seagrass beds from satellite image classification was underestimated compared to the hydroacoustic survey, estimated 3.9 and $4.5km^2$ from satellite image and hydroacoustic data, respectively. Nonetheless, the accuracy of Kompsat-2 image classification over hydroacoustic-based method showing 90% (Kappa=0.85) for the three class maps (seagrass, unvegetated seawater and aquaculture). The agreement between the satellite image classification and the hydroacoustic result was 77.1% (the seagrass presence/absence map). From our result of satellite image classification, Kompsat-2 image is suitable for mapping seagrass beds with high accuracy and non-destructive method. For more accurate information, more researches with a variety of high-resolution satellite image will be preceded.

Investigation on CO Adsorption and Catalytic Oxidation of Commercial Impregnated Activated Carbons (상용 첨착활성탄의 일산화탄소 흡착성능 및 촉매산화반응 연구)

  • Ko, Sangwon;Kim, Dae Han;Kim, Young Dok;Park, Duckshin;Jeong, Wootae;Lee, Duck Hee;Lee, Jae-Young;Kwon, Soon-Bark
    • Applied Chemistry for Engineering
    • /
    • v.24 no.5
    • /
    • pp.513-517
    • /
    • 2013
  • We investigated the properties of impregnated activated carbons, a commercial adsorbent for the individual protection equipment, and examined CO adsorption and oxidation to $CO_2$. The surface area, pore volume and pore size were measured for four commercial samples using Brunauer-Emmett-Teller/Barrett-Joyner-Halenda (BET/BJH), and atomic compositions of the sample surface were analyzed based on SEM/EDS and XPS. Impregnated activated carbons containing Mn and Cu for fire showed the catalytic CO oxidation to $CO_2$ with a high catalytic activity (up to 99% $CO_2$ yield), followed by the CO adsorption at an initial reaction time. On the other hand, C: for chemical biologial and radiological (CBR) samples, not including Mn, showed a lower CO conversion to $CO_2$ (up to 60% yield) compared to that of fire samples. It was also found that a heat-treated activated carbon has a higher removal capacity both for CO and $CO_2$ at room temperature than that of untreated carbon, which was probably due to the impurity removal in pores resulted in a detection-delay about 30 min.

Clinical Evaluation of Human Papillomavirus Detection by careHPVTM Test on Physician-Samples and Self-Samples using The Indicating FTA Elute® Card

  • Wang, Shao-Ming;Hu, Shang-Ying;Chen, Feng;Chen, Wen;Zhao, Fang-Hui;Zhang, Yu-Qing;Ma, Xin-Ming;Qiao, You-Lin
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.17
    • /
    • pp.7085-7090
    • /
    • 2014
  • Objective: To make the clinical evaluation of a solid-state human papillomavirus (HPV) sampling medium in combination with an economical HPV testing method ($careHPV^{TM}$) for cervical cancer screening. Methods: 396 women aged 25-65 years were enrolled for cervical cancer screening, and four samples were collected. Two samples were collected by woman themselves, among which one was stored in DCM preservative solution (called "liquid sample") and the other was applied on the Whatman Indicating FTA $Elute^{(R)}$ card (FTA card). Another two samples were collected by physician and stored in DCM preservative solution and FTA card, respectively. All the samples were detected by $careHPV^{TM}$ test. All the women were administered a colposcopy examination, and biopsies were taken for pathological confirmation if necessary. Results: FTA card demonstrated a comparable sensitivity of detecting high grade Cervical Intraepithelial Neoplasia (CIN) with the liquid sample carrier for self and physician-sampling, but showed a higher specificity than that of liquid sample carrier for self-sampling (FTA vs Liquid: 79.0% vs 71.6%, p=0.02). Generally, the FTA card had a comparable accuracy with that of Liquid-based medium by different sampling operators, with an area under the curve of 0.807 for physician &FTA, 0.781 for physician &Liquid, 0.728 for self & FTA, and 0.733 for self &Liquid (p>0.05). Conclusions: FTA card is a promising sample carrier for cervical cancer screening. With appropriate education programmes and further optimization of the experimental workflow, FTA card based self-collection in combination with centralized $careHPV^{TM}$ testing can help expand the coverage of cervical cancer screening in low-resource areas.

Diagnostic Values of Serum Levels of Pepsinogens and Gastrin-17 for Screening Gastritis and Gastric Cancer in a High Risk Area in Northern Iran

  • Nejadi-Kelarijani, Fatemeh;Roshandel, Gholamreza;Semnani, Shahryar;Ahmadi, Ali;Faghani, Behzad;Besharat, Sima;Akhavan-Tabib, Atefeh;Amiriani, Taghi
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.17
    • /
    • pp.7433-7436
    • /
    • 2014
  • Background: Gastric cancer (GC) is the second cause of cancer related death in the world. It may develop by progression from its precancerous condition, called gastric atrophy (GA) due to gastritis. The aim of this study was to evaluate the accuracy of serum levels of pepsinogens (Pg) and gastrin-17 (G17) as non-invasive methods to discriminate GA or GC (GA/GC) patients. Materials and Methods: Subjects referred to gastrointestinal clinics of Golestan province of Iran during 2010 and 2011 were invited to participate. Serum levels of PgI, PgII and G17 were measured using a GastroPanel kit. Based on the pathological examination of endoscopic biopsy samples, subjects were classified into four groups: normal, non-atrophic gastritis, GA, and GC. Receiver operating curve (ROC) analysis was used to determine cut-off values. Indices of validity were calculated for serum markers. Results: Study groups were normal individuals (n=74), non-atrophic gastritis (n=90), GA (n=31) and GC patients (n=30). The best cut-off points for PgI, PgI/II ratio, G17 and HP were $80{\mu}g/L$, 10, 6 pmol/L, and 20 EIU, respectively. PgI could differentiate GA/GC with high accuracy (AUC=0.83; 95%CI: 0.76-0.89). The accuracy of a combination of PgI and PgI/II ratio for detecting GA/GC was also relatively high (AUC=0.78; 95%CI: 0.70-0.86). Conclusions: Our findings suggested PgI alone as well as a combination of PgI and PgI/II ratio are valid markers to differentiate GA/GC. Therefore, Pgs may be considered in conducting GC screening programs in high-risk areas.

The Infection Status and Perception toward Intestinal Trematodes in an Island Inhabitants (일부 도서지역 주민의 장흡충 감염실태 및 인식)

  • Park, Eun-Mi;Kim, Suk-Il;Park, Hyang;Kim, Ki-Soon;Ryu, So-Yeou;Park, Jong
    • Journal of agricultural medicine and community health
    • /
    • v.25 no.2
    • /
    • pp.303-314
    • /
    • 2000
  • In order to evaluate prevalence and perception on the intestinal trematodes of inhabitants at Docho-island, Shinan-gun, Chollanam-do, a questionnaire survey for the epidemiological study and stool examination for the detection of the eggs of the trematodes were done on 224 individuals at the island from January to February, 2000. The results were as follows: 1. Egg positive rate of the intestinal trematodes was 21.0%. 2. The egg positive rate has revealed significantly higher in the elderly over age 70 than other ages, higher in seashore villagers than inland ones, and higher in persons who had a rural and/or marine ph than persons with other jobs, respectively(P<0.05). 3. The egg positive rate of alcoholic drinkers was higher than non-alcoholic persons, and the rate was also higher in smokers than non-smokers. It was statistically significant(P<0.05). 4. The egg positive rate was shown to be significantly higher in inhabitants who ate raw mullet that was well known to be the source of infection with the intestinal trematodes than people who did not eat the raw marine fishes(P<0.01). 5. The egg positive rate was also significantly higher in humans who had the complaints of frequent abdominal pain and diarrhea than healthy people(P<0.05). In conclusion, the prevalence of intestinal trematodes at the island located in the south and west area in Korea was too high to eradicate the parasitic infections. So a special program is necessary for the control of the trematode infections in many adjacent islands at Chollanamdo.

  • PDF

A comparative study of nondestructive geomagnetic survey with archeological survey for detection of buried cultural properties in Doojeong-dong site, Cheonan, Chungnam Province (매장문화재 확인을 위한 자력탐사 및 발굴 비교연구: 충남 천안시 두정동 발굴지역)

  • Suh, Man-Cheol;Lee, Nam-Seok
    • Journal of the Korean Geophysical Society
    • /
    • v.3 no.3
    • /
    • pp.175-184
    • /
    • 2000
  • A nondestructive experimental feasibility study was conducted using magnetometer to find buried cultural objects at pottery and steel matters in low-relief mountaineous area of Doojeong-dong, Cheonan, Chungnam Province from May 23 to July 18, 1998. Magnetic survey was carried out with $20cm{\times}20cm$ grid in a site of $20m{\times}40m$ before excavation, and the distribution of magnetic anomalies was compared with the results of excavation. Magnetic sensor was located on the surface of ground during the magnetic survey on the basis of an experimental result. Positive magnetic anomalies of maximum 130 nT are found over a pair of potteries. Magnetic anomaly map reveals several anomalous points in the 1st and 4th quadrants of the survey site, from where potteries and their fragments were confirmed. Six points out of seven points cprrelated with magnetic anomaly are found contain earthwares, whereas a magnetically uncorrelated location produced earthware made of unbaked clay. Steel waste such as cans and wires hidden in soil and bushes also influenced magnetic anomalies. Therefore, it is better to remove such steel wastes prior to magnetic survey if possible. Some magnetically anomalous points produced no archaeological object on excavation. This may be explained by shallower level of excavation than burial depth.

  • PDF

REPLACEMENT OF A PHOTOMULTIPLIER TUBE IN A 2-INCH THALLIUM-DOPED SODIUM IODIDE GAMMA SPECTROMETER WITH SILICON PHOTOMULTIPLIERS AND A LIGHT GUIDE

  • KIM, CHANKYU;KIM, HYOUNGTAEK;KIM, JONGYUL;LEE, CHAEHUN;YOO, HYUNJUN;KANG, DONG UK;CHO, MINSIK;KIM, MYUNG SOO;LEE, DAEHEE;KIM, YEWON;LIM, KYUNG TAEK;YANG, SHIYOUNG;CHO, GYUSEONG
    • Nuclear Engineering and Technology
    • /
    • v.47 no.4
    • /
    • pp.479-487
    • /
    • 2015
  • The thallium-doped sodium iodide [NaI(Tl)] scintillation detector is preferred as a gamma spectrometer in many fields because of its general advantages. A silicon photomultiplier (SiPM) has recently been developed and its application area has been expanded as an alternative to photomultiplier tubes (PMTs). It has merits such as a low operating voltage, compact size, cheap production cost, and magnetic resonance compatibility. In this study, an array of SiPMs is used to develop an NaI(Tl) gamma spectrometer. To maintain detection efficiency, a commercial NaI(Tl) $2^{\prime}{\times}2^{\prime}$ scintillator is used, and a light guide is used for the transport and collection of generated photons from the scintillator to the SiPMs without loss. The test light guides were fabricated with polymethyl methacrylate and reflective materials. The gamma spectrometer systems were set up and included light guides. Through a series of measurements, the characteristics of the light guides and the proposed gamma spectrometer were evaluated. Simulation of the light collection was accomplished using the DETECT 97 code (A. Levin, E. Hoskinson, and C. Moison, University of Michigan, USA) to analyze the measurement results. The system, which included SiPMs and the light guide, achieved 14.11% full width at half maximum energy resolution at 662 keV.

Seroprevalence of Norwalk-Like Viruses (NLVs) in Seoul: Detection Using Baculovirus-Expressed Norwalk Virus Capsid Antigen (Baculovirus에서 발현된 Norwalk Virus 캡시드 항원에 대한 국내인의 혈청학적 반응도)

  • Kang, Shin-Jai;Nam, Ki-Bum;Cho, Yang-Ja;Kim, Kyung-Hee
    • The Journal of Korean Society of Virology
    • /
    • v.27 no.2
    • /
    • pp.161-168
    • /
    • 1997
  • The present study was designed to estimate the seroprevalence of NLVs among diarrheagenic children and in healthy adults in Seoul and its vicinity with the use of an EIA and an Western blot (WB) based on recombinant Norwalk virus capsid protein (rNV) and crude virus preparations as antigen. Seroconversion was observed in 34 (83%) of 41 tested using the EIA and in 21 (54%) of 39 using the WB, suggesting that the NLVs with epitopes common to rNV are prevalent in Seoul area. Diarrheal children who were known to have been infected with several other strains of the NLVs showed no significant antibody response to the rNV. Infection with rNV occurred earlier in life: primary infections with rNV were common before the age of 6 months and over 91 % of children had evidence of infection by that age by the EIA. Since the amount of the NLV antigens available for seroepidemiologic surveys is limited, we tried to detect NLV antibody by using crude virus preparations as antigen. One crude virus preparation of a child whose stool yielded genetically distinct NLV revealed the presence of the plural number of bands upon SDS-PAGE, but precipitated only one band (62 kDa) after the WB with a serum (collected 10 days after the onset of symptoms) of another diarrheal child. The WB assay we present in this report revealed that the NLVs are prevalent among Korean population and that the sera contained antibody to a single major structural protein, with molecular sizes of 58 to 62 kDa, compatible with the sizes reported for the Norwalk virus and Snow Mountain agent proteins, respectively. When the results of the WB were compared with those obtained by the EIA, the EIA antibody assay was sensitive enough to detect an antibody rise of as much as 4096-fold but not as specific as the WB. The WB assay presented in this paper will provide a powerful tool to elucidate not only antigenic structures of the NL Vs but also seroepidemiology of the NLV infection. The availability of an unlimited source of antigen will enable a large scale serologic studies that will greatly increase our understanding of the role of NLVs in human enteric illness.

  • PDF

Assessment for the Comparability between Korean Ministry of Environment Standard and ISO Standard for the Determination of Heavy Metals in Soil (토양 중금속 함량 측정에 대한 토양오염공정시험기준과 국제표준간의 적합성 평가)

  • Shin, Gun-Hwan;Lee, Goon-Teak;Lee, Won-Seok;Kim, Ji-In;Kim, Bo-Kyong;Park, Hyun-Jeong
    • Journal of Soil and Groundwater Environment
    • /
    • v.17 no.3
    • /
    • pp.1-9
    • /
    • 2012
  • According to the agreement on WTO/TBT, we are under the situation to adopt international standard (ISO standard) as a national standard if it exists. However, in case of environmental area, it is a domestic legal obligation to use Korean environmental standard method(KESM) for analyzing various contaminants. Therefore it is necessary to assess the comparability between KEM and ISO standard prior to apply ISO standard to soil conservation law in Korea. The main purpose of this study is to assess the comparability of both methods for analyzing heavy metals in soil. We looked over various aspects like pre-treatment, calibration curve range, detection wavelength, soil organic matter content and so on. Apparently, the procedure of both methods is almost same. However in details, both methods are different in stationary time before aqua-regia extraction using reflux system, calibration curve range for Cu, Pb, Ni and measuring wavelength for Pb. According to the results of comparison test, the results were significantly different when the different calibration range was used. In case that all the extracts independent of methods were reanalyzed with the same calibration range of each method, both methods showed statistically same results. Other conditions like different stationary time, measuring wavelength of AAS and soil organic matter content did not have any influence on the analytical result. Therefore, we suggest to extend the calibration curve range to 0~8 mg/L which is used in KS I ISO standard(Korean standard related with environment which is translation version of ISO standard without any technical change). In case of $Cr^{6+}$, the results showed no significant differences between two methods even though the pretreatment, instrumentation and other analysis conditions were different. In addition to UV/Visble spectrometry of KESM for soil contamination, we suggest to adopt ion chromatography of ISO 15192(US EPA method 7199) for analyzing $Cr^{6+}$ with the consideration of laboratory work efficiency.

High Energy Resolution Alpha Spectrometer Using a Cryogenic Detector (저온검출기를 이용한 에너지 고 분해능 알파분광 구현)

  • Kim, M.S.;Lee, S.H.;Yoon, W.S.;Jang, Y.S.;Lee, S.J.;Kim, Y.H.;Lee, M.K.
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.3
    • /
    • pp.132-137
    • /
    • 2013
  • Cryogenic particle detectors have recently been adopted in radiation detection and measurement because of their high energy resolution. Many of these detectors have demonstrated energy resolutions better than the theoretical limit of semiconductor detectors. We report the development of alpha spectrometer using a micro-fabricated magnetic calorimeter coupled to a large-area particle absorber. A piece of gold foil of $2{\times}2{\times}0.05mm^3$ was glued to the paramagnetic temperature sensor made of sputtered Au:Er film to serve as an absorber for incident alpha particles. We performed experiments with 241Am source at cryogen free adiabatic demagnetization refrigerator (CF-ADR). A high energy resolution of 6.8 keV in FWHM was obtained for 5.5 MeV alpha particles.