• Title/Summary/Keyword: Area Detection

Search Result 3,305, Processing Time 0.031 seconds

Respiration Measurement System using Textile Capacitive Pressure Sensor (전기용량성 섬유 압력센서를 이용한 호흡측정 시스템)

  • Min, Se-Dong;Yun, Young-Hyun;Lee, Chung-Keun;Shin, Hang-Sik;Cho, Ha-Kyung;Hwang, Seon-Cheol;Lee, Myoung-Ho
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.1
    • /
    • pp.58-63
    • /
    • 2010
  • In this paper, we proposed a wearable respiration measurement system with textile capacitive pressure sensor. Belt typed textile capacitive pressure sensor approach of respiration measurement, from which respiration signatures and rates can be derived in real-time for long-term monitoring, are presented. Belt typed textile capacitive pressure sensor has been developed for this measurement system. the distance change of two plates by the pressure of motion has been used for the respiration measurement in chest area. Respiration rates measured with the textile capacitive pressure sensor was compared with standard techniques on 8 human subjects. Accurate measurement of respiration rate with developed sensor system is shown. The data from the method comparison study is used to confirm theoretical estimates of change in capacitance by the distance change. The current version of respiratory rate detection system using textile capacitive pressure sensor can successfully measure respiration rate. It showed upper limit agreement of $3.7997{\times}10^{-7}$ RPM, and lower limit of agreement of $-3.8428{\times}10^{-7}$ RPM in Bland-Altman plot. From all subject, high correlation were shown(p<0.0001). The proposed measurement method could be used to monitor unconscious persons, avoiding the need to apply electrodes to the directly skin or other sensors in the correct position and to wire the subject to the monitor. Monitoring respiration using textile capacitive pressure sensor offers a promising possibility of convenient measurement of respiration rates. Especially, this technology offers a potentially inexpensive implementation that could extend applications to consumer home-healthcare and mobile-healthcare products. Further advances in the sensor design, system design and signal processing can increase the range and quality of the rate-finding, broadening the potential application areas of this technology.

Development of Wind Farm AEP Prediction Program Considering Directional Wake Effect (방향별 후류를 고려한 풍력발전단지 연간 에너지 생산량 예측 프로그램 개발 및 적용)

  • Yang, Kyoungboo;Cho, Kyungho;Huh, Jongchul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.7
    • /
    • pp.469-480
    • /
    • 2017
  • For accurate AEP prediction in a wind farm, it is necessary to effectively calculate the wind speed reduction and the power loss due to the wake effect in each wind direction. In this study, a computer program for AEP prediction considering directional wake effect was developed. The results of the developed program were compared with the actual AEP of the wind farm and the calculation result of existing commercial software to confirm the accuracy of prediction. The applied equations are identical with those of commercial software based on existing theories, but there is a difference in the calculation process of the detection of the wake effect area in each wind direction. As a result, the developed program predicted to be less than 1% of difference to the actual capacity factor and showed more than 2% of better results compared with the existing commercial software.

Development of Steam-Generator UT System and Experimental Verification (증기발생기 전열관 확관부의 초음파 검사장치 및 적용기술개발)

  • Park, Jae-Seok;Hong, Soon-Sin;Park, Chi-Seung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.5
    • /
    • pp.442-448
    • /
    • 2007
  • The ultrasonic inspection system for the expansion/transition area of steam generator tube was successfully developed. Variety of artificial flaw and real track specimen was tested using the UT system to verify the performance of the system. All artificial flaws of which through-wall depth larger than 10% was clearly detected by UT system. Measurement results of through-wall depth of flaws larger than 20% had good linearity and reproducibility with 3.27 of standard deviation. Results of real crack specimen test suggested that the detection limit of real crack strongly depends on the track morphology. A potential for measurement of PRL(percentage of remaining ligament) was recognized by the real crack specimen test.

Heterogeneous Porous WO3@SnO2 Nanofibers as Gas Sensing Layers for Chemiresistive Sensory Devices

  • Bulemo, Peresi Majura;Lee, Jiyoung;Kim, Il-Doo
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.5
    • /
    • pp.345-351
    • /
    • 2018
  • We employed an unprecedented technique to synthesize porous $WO_3@SnO_2$ nanofibers exhibiting core-shell and fiber-in-tube configurations. Firstly, 2-methylimidazole was uniformly incorporated in as-spun nanofibers containing ammonium metatungstate hydrate and the sacrificial polymer (polyacrylonitrile). Secondly, the 2-methylimidazole on the surfaces of nanofibers was complexed with tin(II) chloride ($SnCl_2$) via simple impregnation of the as-spun nanofibers in ethanol containing tin(II) chloride dihydrate ($SnCl_2{\cdot}2H_2O$). The presence of vacant p-orbitals in tin (Sn) and the nucleophilic nitrogen on the imidazole ring allowed for the reaction between $SnCl_2$ and 2-methylimidazole, forming adducts on the surfaces of the as-spun nanofibers. The calcination of these nanofibers resulted in porous $WO_3@SnO_2$ nanofibers with a higher surface area ($55.3m^2{\cdot}g^{-1}$) and a better response to 1-5 ppm of acetone than pristine $SnO_2$ NFs synthesized using a similar method. An improved response to acetone was achieved upon functionalization of the $WO_3@SnO_2$ nanofibers with catalytic palladium nanoparticles. This work demonstrates the potential application of $WO_3@SnO_2$ nanofibers as sensing layers for chemiresistive sensory devices for the detection of acetone in exhaled breath.

Kinetic behavior of sophoricoside by gas chromatography/mass spectrometry in rats

  • Jeon, Hee-Kyung;Park, Hae-Yeon;Kim, Youn-Jung;Kim, Youngsoo;Kim, Mi-Kyung;Lee, Seung-Ho;Jung, Sang-Hun;Ryu, Jae-Chun
    • Proceedings of the Korea Society of Environmental Toocicology Conference
    • /
    • 2003.05a
    • /
    • pp.189-189
    • /
    • 2003
  • Sophoricoside was isolated as the inhibitor of IL-5 bioactivity from Sophora japonica (Leguminosae). To develope as novel anti-allergic drug, kinetic study was performed in rats. Serum concentration of sophoricoside was measured by gas chromatography-mass spectrometry (GC/MS) in male Sprague-Dawley rat (250${\pm}$10g, n=5) after oral administration of sophoricoside (100mg/kg). The recovery of sophoricoside after extraction and concentration was above 95 % from rat serum. Between-day precision(relative standard deviation 2.2-2.8%) and within-day precision(2.0-12.1%) were determined from replicate analysis of a spiked control and incurred serum sample. The detection limits of sophoricoside in this serum was approximately 0.1 ng/mL. The Pharmacokinetic parameters were derived from the noncompartmental analysis. The C$\_$max/(3.56${\pm}$0.34 $\mu\textrm{g}$/mL) value for sophoricoside in male rat was observed at 7.6 h. The elimination half-life(t$\_$1/2/) of sophoricoside was approximately 4.47 h, the mean residence time (MRT) averaged 10.75 h, the total body clearance (Cl) averaged 0.0042 mL/min/kg. and the area under the serum concentration-time curve (AUC$\_$0-$\infty$/) was 24.93 $\mu\textrm{g}$$.$hr/mL.

  • PDF

Accumulation of Tributyltin (TBT) in Blood, Liver and Muscle of Olive Flounder (넙치의 혈청, 간 및 근육 중 Tributyltin 축적 경향)

  • Kim, Nam-Sook;Hong, Sang-Hee;Shim, Won-Joon;Jeon, Joong-Kyun
    • Environmental Analysis Health and Toxicology
    • /
    • v.22 no.1 s.56
    • /
    • pp.19-26
    • /
    • 2007
  • Accumulation of tributyltin (TBT) in serum, liver and muscle of olive flounder (Paralichtys olivaceus) was investigated in a 60-d static renewal exposure at $0.1{\mu}g$ TBT/L. Tributyltin accumulated rapidly from 83 ng Sn/g to 2,227 ng Sn/g on a wet weight basis in the serum of the olive flounder and to a greater extent than in the other tissues. The accumulated TBT concentrations in tissues were in the order of serum>liver>muscle on wet or dry-weight basis. High concentrations of dibutyltin (DBT: 990 ng Sn/g dry wt) and monobutyltin (MBT: 141 ng Sn/g dry wt), degradation products of TBT were found in liver of olive flounder at the end of exposure. On the other hand, DBT and MBT was below the detection limits in muscle during the exposure, and only low concentration of DBT (56 ng Sn/g) were detectefd in serum. Butyltin compounds were also quantitatively determined in feral fine-spotted flounder (Pleuronichthys cornutus) collected from Gwangyang Bay as one of polluted area and Sori Island as a reference site. All three butyltin compounds were detected from the fine-spotted flounder from Gwangyang Bay up to 3,107 ng Sn/g of total butyltins in liver, while 120 ng Sn/g of total butyltin concentration was found in the liver of fish from Sori Island.

The Accuracy Analysis and Applied Field Research of a Newly Developed Automatic Heat Detector in Dairy Cow (젖소에 있어서 신개발 무인 발정탐색기의 정확도 분석 및 현장 적용 연구)

  • Back, Kwang-Soo;Lee, Wang-Shik;Park, Seong-Jai;Lim, Hyun-Joo;Son, Jun-Kyu;Kim, Sang-Bum;Kwon, Eung-Gi;Jung, Yeon-Sub;Kim, Kwang-Hyun
    • Reproductive and Developmental Biology
    • /
    • v.35 no.3
    • /
    • pp.395-398
    • /
    • 2011
  • The objective of this study was to compare the accuracy analysis and the effect of field application of a newly developed automatic heat detector in dairy cows. From 2009 to 2010, we used 48 Holstein cows (mounting cows : 38 heads, standing cows : 10 heads) raised in experimental barn of National Livestock Research Institute (RDA) for the accuracy analysis of automatic heat detector, and 14 Holstein cows raised in three commercial dairy farms of Cheonan and Pochun area for comparison of the effect of field application. The accuracy of response in cows attached with automatic heat detector was 86.8% (33/38) displayed on board when mounting activity observed, and 100% (10/10) when standing activity observed, and on average, 90.0% (43/48) displayed on board. The accuracy of automatic heat detector in on-farm test was 85.7% (12/14), and conception rate was 75.0% (9/12).

Reproductive Disorders that Limits the Reproductive Performances in Dairy Cows of Bangladesh

  • Al Maruf, Abdulla;Paul, Ashit Kumar;Bonaparte, Napolean;Bhuyian, Mosharrof Hossain;Shamsuddin, Mohammed
    • Journal of Embryo Transfer
    • /
    • v.29 no.2
    • /
    • pp.189-194
    • /
    • 2014
  • The reproductive disorders are the major causes of reproductive infertility in cows that affect the total annual calf crop, resulting in great economic loss in Bangladesh. The aim of the study was to find out the reproductive disorders (RD) in dairy cows that markedly influences the reproductive performances in aspect of Bangladesh. A total number of 1658 dairy cows were selected according to their body condition score (BCS) in different farms at the southern part of Bangladesh during the period of 2011 to 2012. The preliminary data (basic information) were collected directly from the dairy farmer's record books and asking questions according to a prescribed questionnaires as well as the diagnosis of RD was presumptively confirmed on the basis of history, clinical signs and examination of animals by ultrasonography and others necessary tools. There are thirteen major reproductive disorders were identified. Overall prevalence of reproductive disorders at that area were 23%, among of these anoestrus 5.1%, repeat breeder 3.7%, metritis 4.4%, poor heat detection 1.6%, ovarian cyst 0.36%, retain placenta 4.6%, dystocia 0.97% and pyometra 0.24%. It is indicated that anoestrus and retention of placenta after calving was most hazardous cause of infertility whereas the metritis and repeat breeder were the second line of consequence. RD had shown significantly higher incidence in low BCS (${\leq}2$) than that of fair (2.5) and very good (${\geq}3{\sim}3.5$). In conclusion, the highest RD especially anoestrus and retention of placenta is very alarming for reproductive loss which might be needed further research to identify the specific cause of these disorders for establishment a profitable dairying and dairy population.

Correlations between Expression of Tumor-Related Proteins and COX-2 in Gastric Cancer (위암에서 종양관련 단백질들과 COX-2 발현의 상관성)

  • Yu, Suk;Noh, Jeong-Hwan;Kim, Jong-Yull
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.39 no.3
    • /
    • pp.231-240
    • /
    • 2007
  • It has been reported the higher incidence rate of gastric cancer in our country. Helicobacter pylori (H. pylori), that exhibited a higher infection rate among Korean people, has been known as a cofactor to cause cancer. Therefore, the aim of this study was to identify correlations among overexpressions of COX-2 (Cyclooxygenase-2) gene, p53 mutation and cell proliferation index related to H. pylori. Taking 28 cases of gastric cancer with H. pylori detection, immunohistochemical staining for COX-2, p53 and Ki-67 were performed. In the H. pylori positive group, the well differentiated type and diffuse type of gastric cancer were distributed in larger area and the expression rate of COX-2 was revealed high. The H. pylori negative group showed higher p53 expression than that of the positive group. However, the statistical correlation between H. pylori and histopathological factors was not observed. The significantly higher expression of COX-2 had were observed in both well differentiated type and the intestinal type of gastric cancer. Although there were no statistical significances, this showed a higher inclination of manifest in the early gastric cancer. p53 exhibited a higher tendency of expression in the well differentiated, moderately differentiated and the intestinal type of gastric cancers including the early gastric cancer. Ki-67 was expressed in a significantly higher fashion along with the increase of age. In addition, it was significantly expressed in well differentiated type and intestinal type of gastric cancer. Therefore, these results suggest that H. pylori, COX-2, p53, and Ki-67 influences on the new occurrence of gastric cancer and its development procedures. In the future, the more researches would be required to focus on a larger category relative to gene expressions in gastric cancer.

  • PDF

BEF Detection Algorithm to Improve Reliability of Three-Wire-Unigrounded Distribution Line (3선-단접지배전선로의 신뢰도개선을 위한 BEF 검출 알고리즘)

  • Wan-Ki Min;Myeong-Ho Yoo;Seong-Hwa Kang
    • Journal of the Korean Society of Safety
    • /
    • v.12 no.3
    • /
    • pp.166-172
    • /
    • 1997
  • The BEF on the radial distribution line refers to a class of ground faults in which the load-side power line only is grounded, with the distribution line broken into two parts, the source-side and the load-side. Because its mechanism is remarkably different from that of other earth faults, the fault current is very low, and then difficult to detect the BEF. Thus, it is necessary to analyze its properties and to find an appropriate method that can economically protect the BEF of nonautomation area in the substation. As a result of analyzing the BEF data obtained by the RTDS, EMTP simulation, and the field test data of ETSA, we believe that it is the dominant factor in distinguishing the BEF from normal conditions by a criterion value that is appropriately handled from the zero-sequence current. Thus, with this criterion value, a BEF detecting algorithm is constructed which measures the variations of the zero-sequence current and processes then properly so as to make the fault decision. To prove the accuracy of this algorithm, it is compared with the field test data of ETSA under various conditions. The results show that the proposed algorithm is accurate.

  • PDF