• Title/Summary/Keyword: Area Density

Search Result 4,394, Processing Time 0.037 seconds

Performance Analysis of a Deep Vertical Closed-Loop Heat Exchanger through Thermal Response Test and Thermal Resistance Analysis (열응답 실험 및 열저항 해석을 통한 장심도 수직밀폐형 지중열교환기의 성능 분석)

  • Shim, Byoung Ohan;Park, Chan-Hee;Cho, Heuy-Nam;Lee, Byeong-Dae;Nam, Yujin
    • Economic and Environmental Geology
    • /
    • v.49 no.6
    • /
    • pp.459-467
    • /
    • 2016
  • Due to the limited areal space for installation, borehole heat exchangers (BHEs) at depths deeper than 300 m are considered for geothermal heating and cooling in the urban area. The deep vertical closed-loop BHEs are unconventional due to the depth and the range of the typical installation depth is between 100 and 200 m in Korea. The BHE in the study consists of 50A (outer diameter 50 mm, SDR 11) PE U-tube pipe in a 150 mm diameter borehole with the depth of 300 m. In order to compensate the buoyancy caused by the low density of PE pipe ($0.94{\sim}0.96g/cm^3$) in the borehole filled with ground water, 10 weight band sets (4.6 kg/set) were attached to the bottom of U-tube. A thermal response test (TRT) and fundamental basic surveys on the thermophysical characteristics of the ground were conducted. Ground temperature measures around $15^{\circ}C$ from the surface to 100 m, and the geothermal gradient represents $1.9^{\circ}C/100m$ below 100 m. The TRT was conducted for 48 hours with 17.5 kW heat injection, 28.65 l/min at a circulation fluid flow rate indicates an average temperature difference $8.9^{\circ}C$ between inlet and outlet circulation fluid. The estimated thermophysical parameters are 3.0 W/mk of ground thermal conductivity and 0.104 mk/W of borehole thermal resistance. In the stepwise evaluation of TRT, the ground thermal conductivity was calculated at the standard deviation of 0.16 after the initial 13 hours. The sensitivity analysis on the borehole thermal resistance was also conducted with respect to the PE pipe diameter and the thermal conductivity of backfill material. The borehole thermal resistivity slightly decreased with the increase of the two parameters.

Experimental Study for Confirmation of Relaxation Zone in the Underground Cavity Expansion (지중 내 공동 확장에 따른 이완영역 확인을 위한 실험적 연구)

  • Kim, Youngho;Kim, Hoyeon;Kim, Yeonsam;You, Seung-Kyong;Han, Jung-Geun
    • Journal of the Korean Geosynthetics Society
    • /
    • v.16 no.4
    • /
    • pp.231-240
    • /
    • 2017
  • Recently, there have been frequent occurrences of ground sink in the urban area, which have resulted in human and material damage and are accompanied by economic losses. This is caused by artificial factors such as soil loss, poor compaction, horizontal excavation due to the breakage of the aged sewage pipe, and lack of water proof at vertical excavation. The ground sink can be prevented by preliminary restoration and reinforcement through exploration, but it can be considered that it is not suitable for urgent restoration by the existing method. In this study, a model experiment was carried out to simulate the in-ground cavities caused by groundwater flow for developing non-excavation urgent restoration in underground cavity and the range of the relaxation zone was estimated by detecting the around the cavity using a relaxation zone detector. In addition, disturbance region and relaxation region were separated by injecting gypsum into cavity formed in simulated ground. The shape of the underground cavity due to the groundwater flow was similar to that of the failure mode III formed in the dense relative density ground due to water pipe breakage in the previous study. It was confirmed that the relaxed region detected using the relaxation zone detector is formed in an arch shape in the cavity top. The length ratio of the relaxation region to the disturbance region in the upper part of the cavity center is 2: 1, and it can be distinguished by the difference in the decrease of the shear resistance against the external force. In other words, it was confirmed that the secondary damage should not occur in consideration of the expandability of the material used as the injecting material in the pre-repair and reinforcement, and various ground deformation states will be additionally performed through additional experiments.

Elimination of Lily Symptomless Virus by In Vitro Scaling and Reinfection Rates under Various Culture Conditions in Korean Native Lilies (한국 자생나리의 기내 인편삽에 의한 Lily Symptomless Virus 제거 및 구근 재배조건에 따른 재감염 분석)

  • Kim, Min Hui;Park, In Sook;Park, Kyeung Il;Oh, Wook;Kim, Kiu Weon
    • Horticultural Science & Technology
    • /
    • v.33 no.6
    • /
    • pp.891-899
    • /
    • 2015
  • The lily symptomless virus (LSV) is the most common virus in Korean native lilies and causes various types of damage to overall plant growth. This study was carried out to investigate the elimination rate of the LSV by the in vitro scale culture (scaling) method in Korean native lilies and to test reinfection rates of the LSV under several field culture conditions of bulb production. Four Korean native lilies (Lilium dauricum, L. distichum, L. lancifolium, and L. maximowitzii) were used and their scales were cultured in vitro for micro-scale formation. The micro-scales were subcultured repeatedly using MS culture medium supplemented with 30 or $90g{\cdot}L^{-1}$ sucrose. The culture conditions were $24{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ PPFD with 16 hour daylength using fluorescent lamps and maintained at $22{\pm}2^{\circ}C$. The virus-free bulblets were grown for one to three years in the greenhouse and transplanted to the field in October or March. Virus infection rates were investigated by direct tissue blotting immunobinding assays and measurement of chlorophyll and protein contents. Virus-free plants could be obtained from the 5th subculture of micro-scales in L. lancifolium and L. maximowitzii or from primary culture in L. dauricum and L. distichum. LSV-free plants were reinfected during bulb production in the field. Reinfection rates were higher at older bulb ages and under higher planting density. The plants planted in October and at inland Gyeongsan had higher infection rates than those planted in March and at coastal area Pohang. The reinfection rate of L. maximowitzii was higher than those of L. dauricum and L. lancifolium. The LSV-infected plants had lower chlorophyll contents and unchanged protein contents compared to virus-free plants.

Comparison of using CBCT with CT Simulator for Radiation dose of Treatment Planning (CBCT와 Simulation CT를 이용한 치료계획의 선량비교)

  • Kim, Dae-Young;Choi, Ji-Won;Cho, Jung-Keun
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.742-749
    • /
    • 2009
  • The use of cone-beam computed tomography(CBCT) has been proposed for guiding the delivery of radiation therapy. A kilovoltage imaging system capable of radiography, fluoroscopy, and cone-beam computed tomography(CT) has been integrated with a medical linear accelerator. A standard clinical linear accelerator, operating in arc therapy mode, and an amorphous-silicon (a-Si) with an on-board electronic portal imager can be used to treat palliative patient and verify the patient's position prior to treatment. On-board CBCT images are used to generate patient geometric models to assist patient setup. The image data can also, potentially, be used for dose reconstruction in combination with the fluence maps from treatment plan. In this study, the accuracy of Hounsfield Units of CBCT images as well as the accuracy of dose calculations based on CBCT images of a phantom and compared the results with those of using CT simulator images. Phantom and patient studies were carried out to evaluate the achievable accuracy in using CBCT and CT stimulator for dose calculation. Relative electron density as a function of HU was obtained for both planning CT stimulator and CBCT using a Catphan-600 (The Phantom Laboratory, USA) calibration phantom. A clinical treatment planning system was employed for CT stimulator and CBCT based dose calculations and subsequent comparisons. The dosimetric consequence as the result of HU variation in CBCT was evaluated by comparing MU/cCy. The differences were about 2.7% (3-4MU/100cGy) in phantom and 2.5% (1-3MU/100cGy) in patients. The difference in HU values in Catphan was small. However, the magnitude of scatter and artifacts in CBCT images are affected by limitation of detector's FOV and patient's involuntary motions. CBCT images included scatters and artifacts due to In addition to guide the patient setup process, CBCT data acquired prior to the treatment be used to recalculate or verify the treatment plan based on the patient anatomy of the treatment area. And the CBCT has potential to become a very useful tool for on-line ART.)

Geographic Distribution of Periphyton Diatom Species: A Case Study of Achnanthes convergens in Nakdong River Basin (낙동강 수계 청수성 부착조류의 공간분포 특성에 관한 연구: Achnanthes convergens 를 사례로)

  • Jo, Myung-Hee;Byun, Myeung-Sub;Sim, Jun-Seok;Jang, Sung-Hyun
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.17 no.3
    • /
    • pp.175-194
    • /
    • 2014
  • This study attempts to identify the spatial distributions of Achnanthes convergens, and elucidate the environmental factors that affect the Periphyton diatom habitat. Data in 250 points of Nakdong river basin are collected between April(primary) and September(secondary) 2012, with the National Institute of Environmental Research's support. We define "clean area" over 10% of Achnanthes convergens appearance, and the others as "non-clean areas". Spatial statistics of Kriging, Hotspot, LISA are used in this study. Results show that 1) 56 points are identified as clean areas in the primary survey, while 41 points are discovered in the following survey; 2) using water quality variables, density of turbidity(clean $101.83{\mu}s/cm$; non-clean $598.48{\mu}s/cm$) and conductivity(clean 1.95 NTU; nonclear 5.58 NTU) are five-fold lower in clean-areas; 3) Habitat and Riparian Factors in Nakdong basin illustrate that natural sand bar, diversity of velocity, sediment condition, levee material, riverside land affect Achnanthes convergens; 4) Hotspots of Achnanthes convergens are located in watersheds, including upper Andong Dam, upper Imha dam, Wi-cheon, Miryang river, Nam river and Hwang river whereas mainstream/downstream of Nakdong river and Keumho river watershed are shown as coldspots.

Investigation on Characteristics of Swine Manure of Optimum Volume for Escalator Reversing Composting Facility (돼지분뇨 특성에 따른 기계교반 퇴비화시설의 적정용적 산정 연구)

  • Kwag, J.H.;Choi, D.Y.;Park, C.H.;Jeong, K.H.;Kim, J.H.;Yoo, Y.H.;Youn, C.K.;Ra, C.S.
    • Journal of Animal Environmental Science
    • /
    • v.14 no.2
    • /
    • pp.105-112
    • /
    • 2008
  • This study was carried out to investigate evaporation rate of moisture per surface area and degradation rate of organic matter in full scale escalator reversing composting facility were analyzed to develope a computer program for the computation of an optimum volume of composting facility according to handling methods of swine farm, moisture levels of manure, degradation rate of organics and evaporation rate of moisture during composting. The obtained results can be followed as bellow; The temperature in full scale escalator reversing composting facility during composting reached $70^{\circ}C$ in 4 days and maintained until 11 days. Reduction rate of moisture and density was average 1.20% and 29.7%, respectively. Annual degradation rate of organic matter was 3.53%, showing lowest rate in winter as 3.23%. These seasonal degradation rate could be a factor to be considered for proper management and installation of composting facility. When computed with the amount of feces, urine, slurry and manure plus wastewater produced, the optimum volumes of composting facility for slurry and manure plus wastewater including each 95% moisture was $229m^3$ and $277m^3$, respectively, showing 21% ($48m^3$) difference.

  • PDF

The Selection of Appropriate Sampler for the Assessment of Macrobenthos Community in Saemangeum, the West Coast of Korea (새만금 외해역에서 대형 저서동물 군집 조사를 위한 적정 채집기의 선택)

  • 유재원;김창수;박미라;이형곤;이재학;홍재상
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.8 no.3
    • /
    • pp.285-294
    • /
    • 2003
  • To select an appropriate sampler for the environmental monitoring survey in coastal waters of Saemangeum, Jeollabuk-do, a macrobenthic sampling was conducted in April 2002. Employed samplers were dredge (type Charcot), a semi-quantitative sampler and Smith-McIntyre (SM) and van Veen grab (VV) as quantitative ones. One haul was tried for dredge and 3 replicates (0.1 ㎡${\times}$3) for SM and W at each of 11 stations. Comparisons of sediment volume in sampler bucket and of precision of biological parameters (i.e., density, biomass, species number and diversity index, H') were made between SM and VV. Sediment volume was significantly different (SM > VV) at p-value of 0.0050 (paired t-test) and, in average, 3 replicate samples of SM and VV satisfied a precision level of 0.2 by applying 4th root transformation. Patterns of observed and expected species numbers and H' were compared. Dredge-VV samples showed higher affinity than any other pair. Several dominant species in the area were underestimated in dredge samples (e.g., polychaete Heteromastus filiformis. Aricidea assimilis etc.). Quantifying the agreement pattern of multi-species responses was accomplished by estimating correlations between similarity matrices. Correlation between dredge and VV was slightly higher, but near-per-fect matches were found in general. Different ranks and composition among principal species lists were presumably linked to the effect of penetration depth that differs among samplers. Lower level of some species' abundance in VV samples (ca. 50% compared with those of SM) was explained in this context. It seem appropriate to regard the effect as a probable cause of relatively higher correlations in dredge-VV, Overall bio-logica1 features indicated that a better choice could be SM in situations of requiring high data quality. The others work well, however, on observing and defining faunal characteristics and their capability cannot be questionted if we do not expect a first-order quality.

Clinical Characteristics and Renal Outcomes of Acute Focal Bacterial Nephritis in Children (소아 급성 세균성 신엽염의 임상상 및 신장 예후)

  • Lee Dong-Ki;Kwon Duck-Geun;Lim Yun-Ju;Shin Yun-Hye;Yun Suk-Nam;Pai Ki-Soo
    • Childhood Kidney Diseases
    • /
    • v.8 no.2
    • /
    • pp.229-238
    • /
    • 2004
  • Purpose: This study was perfonned to elucidate the clinical pictures of acute focal bacterial nephritis(nephronia) in children. Methods: We reviewed 9 children with nephronia diagnosed by ultrasonography or computed tomography of kidneys from September 1994 to August 2004. Results: The overall male to female ratio was 2:1, and the age distribution ranged from 0.1 to 6 years(mean $2.8{\pm}2.2$). The cardinal symptoms were fever, chills, abdominal pain and dysuria/frequency. The initial leukocyte count was $21,000{\pm}5,600/uL$, ESR $60{\pm}23mm/hr$, CRP $17{\pm}10\;mg/dl$. Pyuria was noted in every patient and persisted for $10.5{\pm}7.8$ days after antimicrobial treatment. Abdominal sonography demonstrated focal lesion of ill-defined margin and low echogenicity in 5 of 9 patients(55.6%), while computed tomography revealed nonenhancing low density area in all patients(100%). Three of 9 patients(33.3%) had vesicoureteral reflux, greater than grade III. The initial $^{99m}Tc-DMSA$ scan showed one or multiple cortical defects in every patient, and improvements were noted in 2(33.3%) of 6 patients who received follow up scan after 4 months. Intravenous antibiotics was given in every patient under admission. Total febrile period was $11.8{\pm}6.3$ days(pre-admission, $4.0{\pm}3.0;$ post-admission, $7.8{\pm}5.5$ days) and the patients needed hospitalization for $17.2{\pm}8.1$ days. Conclusion: For the early diagnosis of 'acute focal bacterial nephritis' we should perform renal computed tomography first rather than ultrasonography, when the child has toxic symptoms and severe inflammatory responses in blood and urine.

  • PDF

Changes in Soil Properties and Some Problems Induced by Leveling of Paddy Land in Yeongnam Area (경지정리(耕地整理) 답토양의 특성변화 조사(調査))

  • No, Young-Pal;Jung, Yeun-Tae;Park, Chang-Young;Park, Rae-Kyung
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.16 no.2
    • /
    • pp.119-125
    • /
    • 1983
  • To find out problems and changing soil properties induced by leveling of paddy, a field survey was carried out with questionares to farmers of 68 project areas (990 farmers). The soil characteristics between natural soils and cut out sites was compared with soil samples taken from 37 project areas. More than 70 percents of farmers answered to the questionares expressed satisfaction on the paddy land leveling project; however, some farmers replied dissatisfaction that the arable land was decreased the soil productivity due to loss of surface soil or insufficient surface leveling, that the government support was insufficient and that transplanting of rice might be delayed due to retardation of the project. 1. The rate of cut out soils during the land leveling on plain terrain was about 15.3%, but the rates on gently sloped terrain (2-7% slopes) and sloped terrain (7-15% slopes) were relatively high showing 25.9% and 45%, respectively. 2. The deterioration of physical properties was clear in cut out site where the hardness and bulk density increased and the porosity and the rate of water stable aggregate decreased. 3. The degree of deterioration of physical properties on the Diluvial terrace was more severe than on plains or sloped alluvial fans and valleys. The decrease of available phosphorous and the content of organic matter in the cut out place due to land leveling were prominent. 4. The rice yield from cut site was decreased by 28% comparing with that from natural soils.

  • PDF

Studies on the Indigenous Vesicular-Arbuscular Mycorrhizal Fungi(VAMF) in Horticultural Crops Grown Under Greenhouse -I. Spore Density and Root Colonization of the Indigenous VAMF in Soil of Some Horticultural Crops (시설원예(施設園藝) 작물(作物)에서 토착(土着) VA균근균(菌根菌)에 관한 연구(硏究) -I. 감염양상(感染樣相)과 밀도(密度))

  • Sohn, Bo-Kyoon;Huh, Sang-Man;Kim, Kwang-Sik
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.24 no.3
    • /
    • pp.225-233
    • /
    • 1991
  • This study was conducted to evaluate the potential of indigenous vesicular-arbuscular mycorrhizal fungi(VAMF) in the rhizosphere soil of horticultural crops grown under greenhouse and open-field condition, in the southern area of Kores. Soil samples collected from the rhizosphere of some sellected horticultural crops, such as cucumber, hot pepper, lettuca, tomato and eggplant grown under greenhouse or open-field condition. All tested crops are considered as mycorrhizal plants. The infection rate of horticultural crops investigated ranged from 38% to 70%, hot pepper and eggplant grown under greenhouse condition showed the highest infection being 66.0% and 70.0%, respectively. Spore densities were from 4.8 to 20.0g-1 on dried soil basis. Spore densities of VAMF in the rhizosphere soils under greenhouse condition were higher than that of open-field conditions. The highest distribution of spores in diameter ranged from $75{\mu}m$ to $106{\mu}m$ in the rhizosphere soil of lettuce, cucumber and tomato while those in hot pepper and eggplant ranged from $75{\mu}m$ to $250{\mu}m$. Glomus sp.-type spores predominated in the slightly acid soil(pH 6.3), while Acaulospora sp.-type spores greatly predominated in the very strongly acid field(pH 4.9).

  • PDF