• Title/Summary/Keyword: Architectural structure

Search Result 2,065, Processing Time 0.029 seconds

Heavy-impact sound insulation performance according to the changes of dry flooring structure in wall structure

  • Cho, Jongwoo;Lee, Hyun-Soo;Park, Moonseo;Lim, Hohwan;Kim, Jagon
    • International conference on construction engineering and project management
    • /
    • 2017.10a
    • /
    • pp.89-98
    • /
    • 2017
  • The floor heating method generally uses a wet construction method including the installation of resilient material, lightweight foam concrete, heating piping, and finishing mortar. Such a wet construction method not only delays other internal finishing processes during curing period for two mortar pouring process, but also has a disadvantage that it is difficult to replace the floor heating layer when it deteriorated because it is integrated with the frame. Dry floor heating construction method can be a good alternative in that it can solve these defects. Conversely, when it applied to the wall structure that is vulnerable to the interlayer noise compared with the column-beam structure, the question about the heavy-impact sound(HIS) insulation performance is raised. Therefore, conventional dry floor heating method is hard to apply to the wall structure apartments. Therefore, for the purpose to improve the applicability of dry floor heating method in wall structure apartments, this study investigated the change of floor impact sound, especially HIS insulation performance which is one of the required performance for the floor structure. This study tried to examine whether the change of heavy-impact sound pressure level(SPL) shows a tendency at the significant level according to the shape and mass of the floor structure. Through filed experiments on wall structure apartment, this study confirmed that the form of the raised floor shows better HIS insulation performance than the fully-supported form. In addition, it was also confirmed that the HIS insulation performance increases with the mass on the upper part. Moreover, this study found the fact that a mass of about 30 kg/m2 or more should be placed on the upper structure to reduce the heavy-impact SPL according to the bang machine measuring method. Although this study has a limit due to insufficient experiment samples, if the accuracy of this study is increased, it will contribute to the diffusion of dry floor heating by setting the HIS insulation performance target and designing the dry floor heating structure that meets the target.

  • PDF

A Comparative Study of Tensile Strength of Architectural Membrane using Basalt Fiber (현무암섬유 기반 건축용 막재의 강도 비교 연구)

  • Kim, Ji-Hyeon;Shin, Hyeon-Uk;Song, Hun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.149-150
    • /
    • 2016
  • The membrane structure is being applied in structures for various uses for its many advantages as permeableness, lightweightness, constructability, resource saving, and management cost reduction, and the usage is being expanded. However, despite the development of membrane structure, the standard for architectural membrane performance that considered fire safety is still inadequate. Therefore, this study applied basalt fiber with flame resistance on architectural membrane. Also, this study confirmed the membrane applicability of basalt fiber through comparison with existing architectural membrane.

  • PDF

A Comparative Study on the High-rise Building Designs by Frank Lloyd Wright and Mies van der Rohe (프랭크 로이드 라이트와 미즈 반 데르 로우의 고층건물 디자인 비교연구)

  • Kwon, Jong-Wook
    • Journal of architectural history
    • /
    • v.14 no.3 s.43
    • /
    • pp.89-102
    • /
    • 2005
  • Frank Lloyd Wright and Mies van der Rohe are two of the most influential architects in modern architecture. In spite of the different values in their architectural lives, the design of high-rise building had been a continuous matter of primary concern for them. The purpose of this study is to compare the architectural characteristics of the two master architects in terms of building form, structure, function, and envelop skin. glass. Both of them shared with the principle of organic architecture even in the design of high-rise buildings. However, the specific approaches to realize it in high-rise buildings are significantly different. Although they emphasized the integration of building form and structure, Wright regarded the reinforced concrete structure as an organic form-giver, while Mies introduced the steel skeleton structure only as an efficient and flexible building frame. As primary finishing materials for high-rise buildings, glass was used for functional purpose by Wright, but for visual purpose by Mies.

  • PDF

A Study on the Artificial Recognition System on Visual Environment of Architecture (건축의 시각적 환경에 대한 지능형 인지 시스템에 관한 연구)

  • Seo, Dong-Yeon;Lee, Hyun-Soo
    • KIEAE Journal
    • /
    • v.3 no.2
    • /
    • pp.25-32
    • /
    • 2003
  • This study deals with the investigation of recognition structure on architectural environment and reconstruction of it by artificial intelligence. To test the possibility of the reconstruction, recognition structure on architectural environment is analysed and each steps of the structure are matched with computational methods. Edge Detection and Neural Network were selected as matching methods to each steps of recognition process. Visual perception system established by selected methods is trained and tested, and the result of the system is compared with that of experiment of human. Assuming that the artificial system resembles the process of human recognition on architectural environment, does the system give similar response of human? The result shows that it is possible to establish artificial visual perception system giving similar response with that of human when it models after the recognition structure and process of human.

Seismic Characteristics Evaluation According to Construction and Configuration Types of Fortress Structure (성곽구조물의 축조 및 구성형식에 따른 내진특성평가)

  • Kim, Ho-Soo;Yoo, Jun;Kim, So-Yeon;Kim, Jin-Wan
    • Journal of Korean Association for Spatial Structures
    • /
    • v.17 no.2
    • /
    • pp.63-70
    • /
    • 2017
  • In Korea, the occurrence frequency of earthquakes has recently increased, compared with the past. So, the various damages for cultural properties due to earthquake can be expected, and especially fortress structure is vulnerable to earthquake. Therefore, the resonable seismic characteristics evaluation is required to secure the safety for fortress structure with the various construction and configuration types. Also, we should consider the various applied load conditions as design variables. To this end, this study classifies fortress structures according to the construction and configuration types, and then applies the discrete element method to model and analyze fortress structures. Finally, the seismic characteristics is evaluated through slip condition due to the analysis results considering the various design variables.

Technical Limit Analysis of the Construction Method of Free-curved Architectural Structure using 3D Printer (3D 프린터를 이용한 비정형 건축 구조물 시공법의 기술적 한계 분석)

  • Kim, Kyoon-Tai;Jun, Young-Hun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.201-202
    • /
    • 2017
  • In this paper, we classify 3D printer technologies which are becoming a recent issue, and analyzed the features and limitations of the technology. As a result, we can see that there is no 3D printer technology that can produce a completely free-curved architectural structure. In order to construct a completely free-curved architectural structure with a 3D printer, it is necessary to draw up a new concept technique that complements the drawbacks of the two methods.

  • PDF

The Construction Period and the Structure of Seongjeonggak Hall, in Changdeokgung Palace (창덕궁 성정각의 건축 시기와 건축 구조)

  • Lee, Jong-Seo
    • Journal of architectural history
    • /
    • v.28 no.2
    • /
    • pp.41-52
    • /
    • 2019
  • Seongjeonggak Hall in Changdeokgung Palace, although built after the Japanese Invasion in 1592, displays the architectural style and structure of Early Joseon period. It did not include ondol (Korean floor heating system) and contained Early Joseon style window frames. Later, King Jeongjo installed ondol as he repaired the building into a more convenient office. The initial construction of Seongjeonggak Hall was based on the architectural ideology of the Early Joseon Period, which divided up the space according to the season. Thus, the initial structure of the building consisted of a joint of a one-story building and a two-story building with the top floor of the latter specialized for hot and humid season. The two-story building was called 'chimnu(寢樓)', and its top floor was called 'nu-chimsil(樓寢室)'.

Formulation for Shape Change Procedure of Single Prism Tensegrity Structure (단일 프리즘 텐세그리티 구조의 형상 변화 과정 해석을 위한 정식화)

  • Kim, Mi-Hee;Yang, Dae-Hyeon;Kang, Joo-Won;Kim, Jae-Yeol
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.5
    • /
    • pp.3-11
    • /
    • 2018
  • Since the tensegrity structure is flexible and variable, the study on the mobility to the tensegrity has been conducted. However, it is difficult to apply the tensegrity to the architecture field due to several limits. This paper describes the methodology for the analysis of the shape change process of single prism tensegrity structure as an initial study. To apply the tensegrity structure to the architectural field, the assemblage and mathematical formulation procedures of the single prism tensegrity structures are carried out. And single prism tensegrity are presented to the computational strategies for simulate the shape change of those structures. Next, the investigation of structural behaviors through various cases of target displacements is described. Also, the summary of these methods in algorithms is illustrated. As a result it is confirmed that the single prism tensegrity structure model converges 99% on average to a given target node by using the proposed algorithm. Therefore, it is confirmed that the proposed algorithm and program are suitable for shape change analysis of single prism tensegrity structure model.

A Study on the Structural System of Space Configuration in Architectural Plane - Focusing on the Coalesce scheme development for part-whole Process - (건축 평면에서 공간 형상의 구조 체계에 관한 연구 - 부분이 전체를 이루는 합체 도식 개발을 중심으로 -)

  • Piao, Shun-Mei;Yoon, Chae-Shin
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.9
    • /
    • pp.9-20
    • /
    • 2018
  • There are many large and small spaces in the interior of the building, and these spaces are arranged and connected to form a systematic spatial structure. A structure is a collection of several parts to form a whole. In other words, the spatial structure in architecture can be seen as a whole organized and organized as individual unit spaces are gathered together. Therefore, in order to understand the spatial structure, we first need to define the unit spaces that form part, how they are interconnected and arranged, and then understand how and how these unit spaces are organized to form a whole. The main purpose of this study is to study the structural system of space based on the shape information of space on architectural plane. This means interpreting the process and method of how the unit spaces defined as a certain shape on the architectural plane are organized step by step, integrated into a higher level, and eventually integrated into one whole. In this paper, the shape and layout of the unit space are identified in the architectural plan, the connection relation is defined, and expressed in the network form. And suggests a new methodology for interpreting the organizational process in which the following spaces are integrated as a whole. This new methodology is based on human perceptual characteristics. When people recognize an object, they recognize the object partly and completely. We want to explain the relationship between parts of space and the whole according to their characteristics.

An Empirical Analysis of the Financing Behavior of Listed Construction Firms in Korea Stock Market - focused on Testing Two Capital Structure Theories -

  • Seung-Kyu Yoo;Jin-Sik Lim;Ha-Jung Yun;Jae-Kyu Choi;Ju-Hyung Kim;Jae-Jun Kim
    • International conference on construction engineering and project management
    • /
    • 2013.01a
    • /
    • pp.133-140
    • /
    • 2013
  • The purpose of this study is identifying the relationship among the business strategy, order receiving capability and leverage variables of a construction company using industry characteristic variables, in addition to the explanation variables used in the previous studies. The samples of this study were limited to the construction companies listed in Korean stock market. This study built multiple regression analysis models, which have been frequently used in traditional previous studies, in the explanation of company capital structure. Empirical analysis on Static Trade-off Theory and Pecking Order Theory was done by the built model. The study results suggested that the capital structure determination behavior of a construction company generally follows Static Trade-off Theory; however, profitability was found to follow Pecking Order Theory. The explanation variables used in the previous capital structure studies mostly produced significant results; however, the variables, which this study experimentally used, did not produce significant results. It is believed that it implies that additional studies are required in the selection of variables and study methodology. Consequently, a case that unconditionally supports a particular theory is scarce. It has been also found that a case can support both theories at the same time. Therefore, it is believed that development study methodology or introduction of new study methodology that can identify the dynamic characteristic of construction company capital structure formation is required.

  • PDF