• 제목/요약/키워드: Architectural lighting

검색결과 197건 처리시간 0.032초

소규모 사무실 공간에서 간접조명에 대한 조광제어 시스템효율 (Control Efficiency of a Daylight Dimming System for Indirect Lighting in a Small Office)

  • 김수영;정용호;손장열
    • 한국태양에너지학회 논문집
    • /
    • 제26권3호
    • /
    • pp.33-43
    • /
    • 2006
  • Daylight dimming control system was analyzed for an indirect lighting system in a small office space with a double skin envelope system. Computer simulations were performed for photosensors with three shielding conditions. The photosensors were placed on the center of ceiling, and backwall. Three sky conditions defined by CIE were considered. Overall, control performance was not very excellent for all conditions. Fully-shielded photosensor achieved good control performance for some cases, but partially-shielded and unshielded photosensors failed to achieve target illuminance. The variation in desktop illuminance due to daylight was examined for a variety of daylight conditions. Linear correlation between desktop illuminance and photosensor illuminance was analyzed using ANOVA.

LED를 적용한 야간경관조명 설계 프로세스에 관한 연구 (A Study on the Design Process of Night-Scape Lighting Application of LED)

  • 박주영;오민석;김회서;강태경
    • 조명전기설비학회논문지
    • /
    • 제25권6호
    • /
    • pp.1-8
    • /
    • 2011
  • Night-Scape Lighting with the use of LED lighting has become very popular recently by the merits of energy saving, environmental friendlyness, sensitivity and conversion trends. LED lighting designs are being used diversly as outer elements for screen media stage production as well as buildings with fusioning of information technology. However, methods for analyzing the cases effectively are far from completion. This research evaluates the recent trends of Night-Scape Lighting with LED and processes it through database and aims to propose LED Night-Scape Design process for the various architectural night-scape lighting designs.

중규모 사무공간에서 조명에너지 성능평가를 위한 노모그래프 개발에 관한 연구 (Development of Nomographs for the Evaluation of Lighting Energy Performance in a Semi-infinite Office Space)

  • 김한성;고동환;김강수
    • 한국태양에너지학회 논문집
    • /
    • 제23권3호
    • /
    • pp.73-80
    • /
    • 2003
  • The purpose of this study was to analyze daylighting performance in a semi-infinite size office space for lighting energy conservation. DOE2.1E was used for simulations for the model space of $12\times12\times2.6m$. Nomographs were developed which could simulate work plane illuminance, glare index, energy consumption rate and energy reduction rate for daylighting design. Major results of simulations are as follows ; 1) When blinds facing south were installed, 43% of workplane illuminance diminished, but the flare index didn't exceed the recommended max-glare value. 2) In a semi-infinite office space facing south. energy consumption rate in the case space of 500 lux workplane illuminance is larger then case space of 300 lux workplane illuminance. Therefore, energy reduction rate is increased when the semi-infinite office faces south and naintains 300 lux workplane illuminance level.

실내 주광조도 분포 예측식의 제안 및 검증 (Proposal of the Prediction Equation for Interior Daylight Illuminance)

  • 박웅규;박태주;강규민;이상엽;송두삼
    • 한국태양에너지학회 논문집
    • /
    • 제33권3호
    • /
    • pp.114-123
    • /
    • 2013
  • In these days, most of the office buildings are being required to save energy for maintenance. lighting system constitutes 20% to 30% of the total annual electrical energy consumption in office buildings. As an energy saving strategy for lighting system, dimming control system based on illuminance sensors came into use. But the system is accompanied with many illuminance sensors to control lighting and needs a lot of initial investment. In this study, the prediction equation for indoor daylighting illuminance distribution is proposed through the review for conventional research results and field measurements. The proposed equation was verified by the comparison between predicted results and field measurement results. The developed prediction equation for daylighting can be used to control the indoor illuminance level with the limited sensor when dimming control system is operated.

The Evaluation of Ceiling Depth Impact on Lighting and Overall Energy Consumption of a Building with Top-lighting System

  • Amina, Irakoze;Kee, Han Ki;Lee, Young-A
    • Architectural research
    • /
    • 제22권1호
    • /
    • pp.13-21
    • /
    • 2020
  • The purpose of this study was to evaluate the variation in building energy predictions caused by simulation settings related to building envelop thickness. The study assessed the ceiling depth impact on skylight energy performance through OpenStudio integrated Radiance and EnergyPlus simulation programs. A ceiling as deep as 1.5 to 3m was analyzed for skylight to roof ratios from 1% to 25%. The results indicated that the building ceiling depth negatively affected the capability of skylights to significantly reduce building energy consumption. Through a parametric analysis, the study concluded that 8%, 9%, 10% and 11% skylight to roof ratio were optimal in terms of total building energy consumption for a ceiling depth of 1.5m, 2m, 2.5m and 3m, respectively. In addition, the results showed that the usually recommended 5% skylight to roof ratio was only efficient when no ceiling depth was included in the simulation model. Furthermore, the study indicated that the building energy saved by the optimal skylight of each ceiling depth decreased as the ceiling depth deepened. The highest total building energy reduction was 9%, 7%, 5% and 3% for a ceiling depth of 1.5m, 2m, 2.5m and 3m, respectively. This study induced that the solar heat gains and daylight visible transmittance by ceiling depth were crucial in the predictions of skylight energy performance and should not be neglected through building simulation simplifications as it is commonly done in most simulation programs' settings.

업무공간의 조명환경 평가 연구 (A Study on evaluation of lighting environment of people who works in the office spaces)

  • 홍천기;윤아람;하미경
    • 한국실내디자인학회:학술대회논문집
    • /
    • 한국실내디자인학회 2006년도 춘계학술발표대회 논문집
    • /
    • pp.278-283
    • /
    • 2006
  • For the company, the office space is the expensive resource next to human resource. Employees are under the influence of physical characters of the office space. Among them lighting is the most effective factor in physical, biological and psychological for employees. Although there are lots of investments in architectural aspect of the office space, there is almost no investment and consideration about the lighting environment. Therefore this study was trying to find out these things as follow. First, evaluate lighting environment of people who works in the office spaces. Second, find out which factors are more affective in evaluation of lighting environment. And then with these findings this study found what should be considered as important in lighting planning of the office space. As the result of this study, however the majority of the employees are satisfied with current lighting conditions, they are not satisfied with individual operation of lighting. And in office space work type and position changes by age can affect in a large degree more than other factors. Therefore when planning lighting of the office space, it is necessary to figure out work features of Individual and group exactly and accept the difference by positions appropriately.

  • PDF

광기여 필름 LED 팬던트 작업조명시스템 주관평가와 성능검증 (Study of Efficiency Test and Subjective Responses about Pendent Task Lighting System Using Phosphor Luminescent Film LED)

  • 차광석;김회서
    • 설비공학논문집
    • /
    • 제23권3호
    • /
    • pp.188-193
    • /
    • 2011
  • For a long time work or study, pendent task lighting system prepared with phosphor luminescent film LED was developed for eye protection and working efficiency improvement. Developed lighting system was used together with pendent and ambient lighting. Such as, we made comfortable lighting environment system. Evaluation for developed lighting system, that had proceeded to Mock-up test and subjective evaluation. Also It had proceeded that lighting environment analyzed and compatibility valuation of installation. In subjective evaluation, the students have expressed themselves satisfied to phosphor luminescent film LED lighting system. In Mock-up test, It is not problem to intensity of illumination, luminance and color temperature. Therefore, developed LED lighting system was installed at the Daegu apartment. It is having a P.O.E study progress to phosphor luminescent film LED lighting system.

중세 주택의 개구부 형식에 관한 연구 - 통일신라 및 고려시대 주택을 중심으로 - (A Study on the Form of Window and Door of the Medieval Times House - Focused on the House of Unified Silla and Goryo Period -)

  • 이정미
    • 한국주거학회논문집
    • /
    • 제24권6호
    • /
    • pp.133-140
    • /
    • 2013
  • This study is to clarify the form of window and door of medieval times house which are no longer in existence, by comparative analysis between literature materials and architectural remains of united Silla and Goryo period. Particularly the window and door form change process of was analyzed, in connection with the change of term which are recorded in literature material. The form and the composition of window and door are the elements which determine the elevation design of architecture and concerned with interior environment. Therefore this study is significant in the sense that it could be used as base data for the study on the reconstruction and interior space of medieval times house. There were ho (戶) and moon (門) as door, and chang (窓) for lighting and ventilation as window. Among these, the window can be divided into fixed and openable. There were two kind of fixed window. One is called chang (窓), and it was covered by silk or paper for lighting. The other is called ham (檻), it was the form of vertical bar window and lighting and ventilation was available. And there were two kind of openable window. One is called ho (戶), which had wooden plate window leaves. And the other is called changho (窓戶), lighting was available in the condition of closing.

제어가능한 부엌공간 LED조명에서의 색온도, 조도, 제어속도 추출에 관한 연구 (A Study on the Extraction of Correlated Color Temperature, Illuminance, Control Speed under Controllable LED Lighting in the Kitchen Space)

  • 이진숙;정찬웅;박지영
    • 조명전기설비학회논문지
    • /
    • 제28권5호
    • /
    • pp.1-14
    • /
    • 2014
  • This study has found out appropriate scopes of correlated color temperature and illuminance value with regard to general diffused lighting and work in the kitchen. It also has presented appropriate photometric quantity control speed for behavioral change with the following results. 1)For general diffused lighting, the appropriate photometric quantity has turned out to be 4,000 to 4,500K in color temperature and illuminance value of 300 to 400lx. And 300lx at 4,500K has proven to be the most comfortable, behavior-appropriate, and preferred pair. 2)As far as appropriate photometric quantity for work is concerned, color temperature of 4,000 to 5,000K and illuminance value of 600 to 800lx are appropriate, while 700lx at 4,500 to 5,000K are the most comfortable, behavior-appropriate, and preferred set. 3)As for appropriate photometric quantity control speed in behavioral change, 3 to 5 seconds has proven the most comfortable, appropriate, and preferred for behavioral change from entry to general areas and 1 to 3 seconds for change from general to work.

건축물의 조명디자인 프로세스 및 평가방법에 관한 연구 (A Study on the Evaluation Method and Process of Lighting Design in Building)

  • 최영준;서동연
    • 한국실내디자인학회논문집
    • /
    • 제13권2호
    • /
    • pp.176-183
    • /
    • 2004
  • This research is aimed at being a cornerstone to elicit the evaluation methodology of systematic and objective lighting design process on the basis of investigation of documentation and interviews on lighting design of architecture which is drawing more and more attention in an architectural field. In evaluating lighting design in architecture, such factors as appropriate illumination, quality of light, completion degree, reflection of use, visual amenity, understanding, amiability, artistic value, recognition, regional conditions, and extent of glare are to be more considered than anything else. In so far as general sectors of society show ever-increasing interest in lighting design, developments in both its quality and its quantity are also expected; thus, evaluation items shown in this research will be useful in appraisal of interior and exterior lighting of architecture.